Report of Micro- Controle measurements Visit (two MB type 0 Girders manufactured)

7
Report of Micro-Controle measurements Visit (two MB type 0 Girders manufactured) 29 November 2010 1 Nick Gazis, CERN-BE/RF & NTU- Athens Input from : Germana Riddone, Alexandre Samochkine, Helene Mainaud-Durand, Sylvain Griffet, Monique Dupont

description

Report of Micro- Controle measurements Visit (two MB type 0 Girders manufactured). Input from : Germana Riddone, Alexandre Samochkine , Helene Mainaud-Durand, Sylvain Griffet, Monique Dupont. Micro- Controle Supporting System (MB type 0). Micro- Controle Supporting System (MB type 0). - PowerPoint PPT Presentation

Transcript of Report of Micro- Controle measurements Visit (two MB type 0 Girders manufactured)

Page 1: Report of Micro- Controle  measurements Visit (two  MB  type  0 Girders  manufactured)

Nick Gazis, CERN-BE/RF & NTU-Athens 1

Report of Micro-Controle measurements Visit (two MB type 0 Girders manufactured)

29 November 2010

Input from: Germana Riddone, Alexandre Samochkine, Helene Mainaud-Durand, Sylvain Griffet, Monique Dupont

Page 2: Report of Micro- Controle  measurements Visit (two  MB  type  0 Girders  manufactured)

Nick Gazis, CERN-BE/RF & NTU-Athens 229 November 2010

Micro-Controle concept

Main Beam Type 0 Girders with

integrated (glued) V-shaped supports

(SiC) [complete CLIC Two-Beam Module Supporting System (CLIATLSS0006)]

Micro-Controle Supporting System (MB type 0)

Page 3: Report of Micro- Controle  measurements Visit (two  MB  type  0 Girders  manufactured)

Nick Gazis, CERN-BE/RF & NTU-Athens 329 November 2010

Micro-Controle Supporting System (MB type 0)

Station 1

Station 2 Station 3

Girder 1

Girder 2

Measurements layout

V-supports alignment measurements with reference cylinder under loaded (realistic) condition

Dimensional control of the interface plate for the alignment sensors plate

V-supports alignment tolerance (for each girder) ≤ 10 μm (in respect with fabrication drawings tolerances)

Page 4: Report of Micro- Controle  measurements Visit (two  MB  type  0 Girders  manufactured)

Nick Gazis, CERN-BE/RF & NTU-Athens 429 November 2010

Micro-Controle Girders

Risk assessment details for handling and loading of (ceramic) SiC girders and V-supports: EDMS 1103518 v.1

V-supports can sustain statically 80 kg each V-supports can sustain 200 N of horizontal force

V-supports have a Safety factor of 10 (considering fabrication errors)

× Dynamic loading or shock (over going the elastic limit of SiC) can cause rupture

× Dynamic and Active loading should be avoided on Girders

V-supports

If not..

Device of dynamic absorption should be predicted and installed

Transportation protocol for CLIC girders (ceramic): EDMS 1106041 v.1

Page 5: Report of Micro- Controle  measurements Visit (two  MB  type  0 Girders  manufactured)

Nick Gazis, CERN-BE/RF & NTU-Athens 529 November 2010

Micro-Controle Girders

Risk assessment details for handling and loading of (ceramic) SiC girders and V-supports: EDMS 1103518 v.1

V-supports can sustain statically 80 kg each V-supports can sustain 200 N of horizontal force

V-supports have a Safety factor of 10 (considering fabrication errors)

× Dynamic loading or shock (over going the elastic limit of SiC) can cause rupture

× Dynamic and Active loading should be avoided on Girders

V-supports

If not..

Device of dynamic absorption should be predicted and installed

Transportation protocol for CLIC girders (ceramic): EDMS 1106041 v.1

Not our Girder !!! but result of mishandling of SiC components

Page 6: Report of Micro- Controle  measurements Visit (two  MB  type  0 Girders  manufactured)

Nick Gazis, CERN-BE/RF & NTU-Athens 6

Thank you!

6Nick Gazis, CERN-BE/RF & NTU-Athens29 November 2010

Page 7: Report of Micro- Controle  measurements Visit (two  MB  type  0 Girders  manufactured)

Nick Gazis, CERN-BE/RF & NTU-Athens 729 November 2010

Type 0 Type 0 Type 1 Type 4

DB

MB

fabricated

fabricated fabricated

delivered deliveredfabricated

Boostec

Micro-Controle

Epucret

Supplementary Slide

Two-Beam Test Stand Girder Index