Asgard Access Plus Instructions

Post on 25-Jul-2016

256 views 3 download

description

For more information please visit www.asgardsss.co.uk

Transcript of Asgard Access Plus Instructions

It is always recommended to anchor the unit in to the ground. Drill through the four holes in the base of the unit using 6mm dia masonry drill to a depth of 70mm. Screw in the anchor fixings. (These have a self cutting thread). If not anchoring the unit, fit the self seal plugs BEFORE BUILDING to block the fixing holes from underneath.

TOOLS REQUIREDPower driver POSI-DRIV screwdriver, 6mm dia. masonry drill and a13mm socket or spanner.

ACCESS PLUS

ZSC

REW

32 x

4

ZSC

REW

381

x12

ZSC

REW

100

x62

ZSC

REW

340

x12

4184

3 x

1 /4

1844

x1

ZHW

MIS

C89

x2

ZHW

HAN

DLE

32 x

1

ZSC

REW

42 x

4

4145

9 x

4

4182

4 x

2

4145

9 x

4

6mm Dia.

Posi-DrivScrewdriver

13mm Spanner

18V

ZCO

MPP

LZS0

2 x

4

ZCO

MPP

LAS2

2-23

-24

x12

4x 2

mm

, 4x

3mm

, 4x

5mm

BASE PANEL 51838 x1

LH B

ACK

PAN

EL 5

1842

x1

RH

BAC

K PA

NEL

518

41 x

1

RH

SID

E PA

NEL

413

31 x

1

LH S

IDE

PAN

EL 4

1329

x1

LH F

RO

NT

PAN

EL 4

1452

x1

RH

FR

ON

T PA

NEL

414

53 x

1

RH

DO

OR

S/A

518

46 x

1

LH D

OO

R S

/A 5

1844

x1

LID S/A 51836 x1

BASE INSTRUCTIONSFlat and firm base. Recommended: concrete, tarmac or paving flags. Min. distance from walls/ shrubbery: 1000mm.Min. base size (WxDxH) 2450mm x 1150mm x 50mm.

LEVELING THE UNITCorrectly level the constructed unit using the shims (ZCOMPPLAS) provided prior to fixing the unit to the ground. Slide the packing pieces under the corners of the unit base as required until an equal gap has been achieved around the door allowing for its smooth operation and alignment.

For maintenance instructions of this product visit www.asgardsss.co.uk

x2

Warning: some panels may weigh over 20Kg. Beware of manual handling

ZHW

NU

T41

x12

ZSC

REW

43 x

10

2x 70mm disc padlocks required. Not supplied. Keys alike recommended.

1

3

5 6

4

2PLEASE NOTE ALL SCREWS ARE FIXED FROM THE INSIDE

x4 x11

x16 x18

x12

BASE PANEL 51838

RH

BAC

K PA

NEL

518

41

LH B

ACK

PAN

EL 5

1842

RH

SID

E PA

NEL

413

31

LH S

IDE

PAN

EL 4

1329

LH F

RO

NT

PAN

EL 4

1452

RH

FR

ON

T PA

NEL

414

53

CO

RN

ER B

RAC

ES:

4184

3 an

d 41

844

x4

x4

x3

x3

x3x3

x7

x5

x5

x5

x5

x2x2

x2x2

x3

x3

x12

RH

DO

OR

S/A

518

46

LH D

OO

R S

/A 5

1844

x3

x3

x3

x3

x3

x3

7 8

9 10

11 12

x2

x12 x12

LID S/A 51836

4145

9

ZHW

MIS

C89

ZSC

REW

381

4145

9

4145

9

x2

x2

ZHWHANDLE32

x2

13 14!

15!

ENSURE CORRECT ALIGNMENTBEFORE ATTACHING SHROUDS(41824)

FIT SHROUDS (41824)AS HIGH UP AS POSSIBLE

SHROUDS 41824

www.asgardsss.co.uk052216/22.01.16/KW/REV1

x4

x8