Asgard Centurion Shed Instructions

4
It is always recommended to anchor the unit to the ground. Drill through the four holes in the base of the unit using 6mm dia masonry drill to a depth of 70mm. Screw in the anchor fixings. (These have a self cutting thread). If not anchoring the unit, fit the self seal plugs BEFORE BUILDING to seal the fixing holes from underneath. Please note product must be bolted down to comply with LPS1175. TOOLS REQUIRED Power driver POSI-DRIV screwdriver, 6mm dia. masonry drill and a 13mm socket or spanner. CENTURION LH F. SIDE PANEL 32941 x1 LH R. SIDE PANEL 32874 x1 F. BASE PANEL 32940 x1 R. BASE PANEL 32871 x1 LH DOOR 32943 x1 RH DOOR 32944 x1 FRONT FASCIA 32948 x1 ZSCREW32 x8 ZSILCO1 x1 ZSCREW04 x4 ZSCREW100 x184 ZSCREW340 x24 32670 x16 13mm Spanner 18V ZCOMPPLZS02 x8 ZCOMPPLAS22-23-24 x12 4x 2mm, 4x 3mm, 4x 5mm BASE COVER CHANNEL 37364 x1 SIDE COVER CHANNEL 32916 x2 ROOF COVER CHANNEL 32918 x2 F. TOP PANEL 32986 x1 TOP SHROUD 32945 x2 R. TOP PANEL 32987 x1 RH F. SIDE PANEL 32942 x1 RH R. SIDE PANEL 32875 x1 BASE INSTRUCTIONS Flat and firm base. Recommended: concrete, tarmac or paving flags. Min. distance from walls/ shrubbery: 1000mm. Min. base size (WxDxH) 2640mm x 1730mm x 50mm. LEVELING THE UNIT Correctly level the constructed unit using the shims (ZCOMPPLAS) provided prior to fixing the unit to the ground. Slide the packing pieces under the corners of the unit base as required until an equal gap has been achieved around the door allowing for its smooth operation and alignment. LH BACK PANEL 32867 x1 RH BACK PANEL 32876 x1 For maintenance instructions of this product visit www.asgardsss.co.uk Warning: some panels may weigh over 20Kg Beware of manual handling Warning: Please keep this key card safe! Refer to if replacement key is required. x2 SEALANT 00001 YOUR UNIQUE KEY CODE ROOF JOINT STRIP 40446 x2 6mm Dia. Posi-Driv Screwdriver

description

For more information please visit www.asgardsss.co.uk/metal-sheds-large/large-metal-shed-the-centurion

Transcript of Asgard Centurion Shed Instructions

Page 1: Asgard Centurion Shed Instructions

It is always recommended to anchor the unit to the ground. Drill through the four holes in the base of the unit using 6mm dia masonry drill to a depth of 70mm. Screw in the anchor fixings. (These have a self cutting thread). If not anchoring the unit, fit the self seal plugs BEFORE BUILDING to seal the fixing holes from underneath. Please note product must be bolted down to comply with LPS1175.

TOOLS REQUIREDPower driver POSI-DRIV screwdriver, 6mm dia. masonry drill and a13mm socket or spanner.

CENTURION

LH F. SIDE PANEL

32941 x1

LH R. SIDE PANEL

32874 x1

F. BASE PANEL

32940 x1

R. BASE PANEL

32871 x1

LH

DO

OR

3294

3 x1

RH

DO

OR

3294

4 x1

FRONT FASCIA32948 x1

ZSC

REW

32 x

8

ZSIL

CO

1 x

1

ZSC

REW

04 x

4

ZSC

REW

100

x18

4

ZSC

REW

340

x24

3267

0 x

16

13mm Spanner

18V

ZCO

MPP

LZS0

2 x

8

ZCO

MPP

LAS2

2-23

-24

x12

4x 2

mm

, 4x

3mm

, 4x

5mm

BASE

CO

VER

CH

ANN

EL 3

7364

x1

SID

E C

OVE

R C

HAN

NEL

329

16 x

2

RO

OF

CO

VER

CH

ANN

EL 3

2918

x2

F. TOP PANEL

32986 x1

TOP SHROUD

32945 x2

R. TOP PANEL

32987 x1

RH F. SIDE PANEL

32942 x1

RH R. SIDE PANEL

32875 x1

BASE INSTRUCTIONSFlat and firm base. Recommended: concrete, tarmac or paving flags. Min. distance from walls/ shrubbery: 1000mm.Min. base size (WxDxH) 2640mm x 1730mm x 50mm.

LEVELING THE UNITCorrectly level the constructed unit using the shims (ZCOMPPLAS) provided prior to fixing the unit to the ground. Slide the packing pieces under the corners of the unit base as required until an equal gap has been achieved around the door allowing for its smooth operation and alignment.

LH

BAC

K PA

NEL

3286

7 x1

RH

BAC

K PA

NEL

3287

6 x1

For maintenance instructions of this product visit www.asgardsss.co.uk

Warning: some panels may weigh over 20KgBeware of manual handling

Warning: Please keepthis key card safe! Referto if replacement key is required.

x2

SEAL

ANT

00001

YOUR UNIQUEKEY CODE

ROOF JOINT

STRIP 40446 x2

6mm Dia.

Posi-DrivScrewdriver

Page 2: Asgard Centurion Shed Instructions

RH

BAC

K PA

NEL

3287

6

RH

R. S

IDE

PAN

EL32

875

REAR BASE PANEL

32871

x15

1

3

5 6

4

2

x19 x22

x10

PLEASE NOTE ALL SCREWS ARE FIXED FROM THE INSIDE

LH R

. SID

E PA

NEL

3287

4

x16 x13

R. T

OP

PAN

EL32

987

F. BASE PANEL

32940 x1

LH B

ACK

PAN

EL32

867

x15

x3

x7

x3

x16

x7

x15

x13

x4

x4

x4x4

Page 3: Asgard Centurion Shed Instructions

7 8

9 10

11 12

x34 x6

x30 x24

x4 x4

LH F

. SID

E PA

NEL

3294

1

RH F. SIDE PANEL

32942

FRO

NT

FASC

IA32

948

F. TOP PANEL

32986

LH D

OO

R32

943

RH

DO

OR

32

944

1ST TOP SHROUD

32945

2ND TOP SHROUD

32945

SHROUDS 32945

x15

x3

x3

x15

x7

x7

x4x4

x4

x4 x7

x7

x2

x2

x4

x3

x3

x3

x3

x3

x3

x3

x3

SHROUDS

ROOF STRIP

ROOF JOINT STRIP 40446

APPLY TO BOTH

ROOF JOINT STRIP 40446

ROOF JOINT STRIP END40446

Page 4: Asgard Centurion Shed Instructions

13 14

15 16

www.asgardsss.co.uk

x16

x8

REMOVE SCREWS WHICH ALIGNWITH THE COVER CHANNELS. ALIGN AND PLACE SCREWS BACK!

REMOVE SCREWS WHICH ALIGNWITH THE COVER CHANNELS. ALIGN AND PLACE SCREWS BACK!

SID

E C

OVE

R C

HAN

NEL

329

16

BASE

CO

VER

CH

ANN

EL 3

7364

033015/03.08.15/KW/REV4

RO

OF

CO

VER

CH

ANN

EL 3

2918

3267

0