Pyroelectric Infrared Sensor - nicera.co.jp · È · 8 ) e k z & * Ø Ã - } 4 l * â % = I =...

10
Pyroelectric infrared sensor sharply detects infrared emitted by human body etc., using pyroelectric effect of ferroelectric ceramics. - 1 - Pyroelectric Infrared Sensor Pyroelectric Infrared Sensor developed and supplied to the market by NiCeRa is being used worldwide for many applications. For example, light switch control, visitor acknowledgement, security systems and burglar alarm. Utilizing our expertise gained by years of experience, we satisfy marketing needs for high quality and low cost. This is called Pyroelectric Effect. When ferroelectrics receive infrared and absorbs the thermal energy, a change occurs in its spontaneous polarization, and electrical charge will be excited on its surface in proportion to the amount of change. Principle of Operation

Transcript of Pyroelectric Infrared Sensor - nicera.co.jp · È · 8 ) e k z & * Ø Ã - } 4 l * â % = I =...

Pyroelectric infrared sensor sharply detects infrared emitted by human body etc., using pyroelectric effect offerroelectric ceramics.

- 1 -

Pyroelectric Infrared Sensor

Pyroelectric Infrared Sensor developed and supplied to the market by NiCeRa is being used worldwide for manyapplications. For example, light switch control, visitor acknowledgement, security systems and burglar alarm.Utilizing our expertise gained by years of experience, we satisfy marketing needs for high quality and low cost.

This is called Pyroelectric Effect.

When ferroelectrics receive infrared and absorbs the thermal energy, a change occurs in its spontaneouspolarization, and electrical charge will be excited on its surface in proportion to the amount of change.

Principle of Operation

Element Type Recommended Model Features Application

SBAC10-11-GCompensated Single

Detect intrusion from any angle. Human Body DetectorOutputs by rapid change in ambient temperature are also Flame Detectorcancelled by compensating element.

RE200GGeneral-Purpose Dual

This model is designed for low cost solution while keeping Automatic Lighting Switchdetection performance at reasonable level. Security Alarm

Toys

SFG323-671High-Grade Dual

Best choice for human body detector. Security AlarmHighly sensitive to human body while remaining insensitive Air-Conditionerto ambient temperature change, vibration, RFI, white lightnoise etc.

SBG446-671Omni-Directional Quad

Omni directional detection is archieved by unique quad Security Alarmelement configration. Highly sensitive to small movements (For Ceiling Mount Application)

of hands, heads etc. Automatic Lighting Switch

SQG413-612Dual-Output Quad

With two independent dual element signals, cancellation of Security Alarmsignals by small animal is possible. (Without false alarm by small animals)

- 2 -

Specifications

Compensated Single General-Purpose Dual High-Grade Dual Omni-Directional Quad Dual-Output Quad

SBAC10-11-G RE200G SFG323-671 SBG446-671 SQG413-612

138 134 132 145

X-axis X-axis X, Y-axis X-axis

125 120 146 145

Y-axis Y-axis 45 Y-axis

1: Source(1)

1: Drain 1: Drain 1: Drain 1: Drain 2: Drain

2: Source 2: Source 2: Source 2: Source 3: Source(2)

3: Ground 3: Ground 3: Ground 3: Ground 4: Ground

- 3 -

Equivalent Circuit

Element Type

FOV

Outline Dimensions [mm]

FOV, Outline Dimensions, Equivalent Circuit

Element Type

Parameters SBAC10-11-G RE200G SFG323-671 SBG446-671 SQG413-612

[mm]Sensitive Area

Spectral Response

[mVp-p]Signal Output

[mVp-p]Noise

[V]Source Voltage

[V]Supply Voltage

[ ]Operating Temperature

[ ]Storage Temperature

Compensated Single General-Purpose Dual High-Grade Dual Omni-Directional Quad Dual-Output Quad

-40 +80-40 +80-40 +80-30 +80-30 +80

-40 +70-40 +70-40 +70-20 +70-20 +70

3 103 103 103 103 10

0.650.750.750.750.75

1201007070100

- 4 -

1.3 x 11 x 12.3 x 0.752.3 x 1

8 138 138 138 138 13

4,0005,5003,5003,3003,200

Ratings (at 25 degC)

Test Item Conditions Criteria

High-Temperature High-Humidity Storage Test JIS C7021: B-11 Condition B Temperature : 60 degC Relative Humidity : 95% Store for 1,000 hours

High-Temperature Storage Test Nicera Conditions based on JIS C7021: B-10 Temperature : 100 degC Store for 1,000 hours

Low-Temperature Storage Test NiCeRa Conditions based on JIS C7021: B-12 Temperature : -40 degC Store for 1,000 hours

Temperature Program of Thermostat Bath

Hermetic Seal Immerse in water, 160mmHg, for 1 minute

No visible bubble.

JIS C7201: A-4

200 cycles with the conditions below :

Heat Shock Test

After test, leave sensors at normal temperature for 2 hours, then measure sensitivity and noise. Sensors of which change rate is within +/- 20% from initial measured values are judged as Pass. No significant damage in appearance.

- 5 -

Measuring Method

(RE200G)

- 6 -

Measuring Method

Frequency Response of Amplifier

Frequency Characteristics

Typical Signal of Dual Element Detector

[Hz]

Frequency

[dB]

Gain

- 7 -

Typical Configuration

Typical Application Circuit

Optical Filter

Spectral Response of Window Materials

- 8 -

Related Products

Fresnel Lens

Sensor : Dual Element Sensor : Quad ElementSensor Tab : A Sensor Tab : A

Sensor : Quad ElementSensor Tab : B

NCL-9(26)

- 9 -

Sensor : Dual Element Sensor : Quad Element

Sensor : Dual Element Sensor : Quad ElementSensor Tab : 90° Sensor Tab : 45°