Hammamet meeting - SMART project Hammamet meeting Definition of the Water Quality Indicators With...

13
Hammamet meeting - SMART project Hammamet meeting Hammamet meeting Definition of the Water Quality Definition of the Water Quality Indicators Indicators With the TELEMAC chain Softwares With the TELEMAC chain Softwares

Transcript of Hammamet meeting - SMART project Hammamet meeting Definition of the Water Quality Indicators With...

Hammamet meeting - SMART project

Hammamet meetingHammamet meetingDefinition of the Water Quality Definition of the Water Quality

IndicatorsIndicatorsWith the TELEMAC chain SoftwaresWith the TELEMAC chain Softwares

Hammamet meeting - SMART project

Model construction

Definition of the scenarios

Hydrodynamic simulations

Water quality simulations

INDICATORS of water quality result

Choise of 2 hydrodymanic scenarios (common & worst conditions)

Choise of the pollutant ( location, concentration, …)Choise of the guide/mandatory values

Bathymetry data analysisMesh construction

TELEMAC-2D :Boundary conditions impositionCalibration – validation stepsAnalysis of hydrodynamical results

SUBIEF-2DTracor concentration and flow impositionCalibration – validation stepsAnalysis of the water quality results

Software INDICATOR.exe

Hammamet meeting - SMART project

Theorical case study :Aqaba Gulf mesh

Study area

4 pollution sourcesMesh refined at each sources

Hammamet meeting - SMART project

Theorical case study :Aqaba Gulf bathymetry

Hammamet meeting - SMART project

Imposed sea level

Hammamet meeting - SMART project

Theorical case study :Aqaba Gulf currents video

Hammamet meeting - SMART project

Theorical case study :Aqaba Gulf water quality simulation

Scenario of the water quality modelisation:

-Pollutant : Escherichia Coli (bacteriological pollution)

-4 different pollutant sources

-Flow of the sources imposed constant and equal to 1 m3/s

-Pollutant concentration in the outlet equal to 1E9 EC/100 ml

Hammamet meeting - SMART project

Theorical case study :Aqaba Gulf bathymetry

Indicators.exe

Hammamet meeting - SMART project

Mandatory value

Guide value

Parameter concentration

time

Mandatory value

Guide value

Parameter concentration

time

Selected period Selected period

0%

2%

7%

8%

Excellent Quality Poor Quality

Mandatory value

Guide value

Parameter concentration

time

Selected period

2%

80%

Good Quality

Methodology proposed to interpret TELEMAC results is based on the European Directive concerning the Quality of Bathing Water.

Hammamet meeting - SMART project

Hammamet meeting - SMART project

Hammamet meeting - SMART project

Mandatory Value = 2000 EC / 100 mlGuide Value = 500 EC / 100 ml