FALSE CEILING “PLAN” Supply of a metal false ceiling for interiors, made with modular panels of the “Atena Plan” type, with size 600x600 mm and right edge, laid on T-grid type Atena EASY Base 24mm. The system will consist of panels obtained from the processing of coils of: ALUMINUM (3105 alloy), corrosion resistance class C5. thickness: 5/10 | 6/10 mm finishing: White | Silver with primer on hidden side and matt (about 25 gloss) pre-painted visible side. RAL_____________ | NCS____________ Smooth surface: Glossy | Semi-glossy | Matt Matt wrinkled appearance Electrostatic post-painting with a special mixture of polyester resins, which ensure color stability over time; declared thickness not less than 80µm, nanotechnological pre-treatment for greater resistance to corrosion. STEEL thickness: 5/10 mm finishing: White | Silver with primer on hidden side and matt (about 25 gloss) pre-painted visible side. Corrosion resistance class C3. RAL_____________ | NCS____________ Smooth surface: Glossy | Semi-glossy | Matt Matt wrinkled appearance Electrostatic post-painting with a special mixture of polyester resins, which ensure color stability over time; declared thickness not less than

Transcript of Atena · Web viewFALSE CEILING “PLAN” Supply of a metal false ceiling for interiors, made with...

Page 1: Atena · Web viewFALSE CEILING “PLAN” Supply of a metal false ceiling for interiors, made with modular panels of the “ Atena Plan ” type, with size 600x600 mm and right edge,

FALSE CEILING“PLAN”

Supply of a metal false ceiling for interiors, made with modular panels of the “Atena Plan” type, with size 600x600 mm and right edge, laid on T-grid type Atena EASY Base 24mm.

The system will consist of panels obtained from the processing of coils of: ALUMINUM (3105 alloy), corrosion resistance class C5.

thickness: 5/10 | 6/10 mm

finishing: White | Silver with primer on hidden side and matt (about 25 gloss) pre-painted visible side.

RAL_____________ | NCS____________ Smooth surface: Glossy | Semi-glossy | Matt Matt wrinkled appearanceElectrostatic post-painting with a special mixture of polyester resins, which ensure color stability over time; declared thickness not less than 80µm, nanotechnological pre-treatment for greater resistance to corrosion.

STEEL thickness: 5/10 mm

finishing: White | Silver with primer on hidden side and matt (about 25 gloss) pre-painted visible side.Corrosion resistance class C3.

RAL_____________ | NCS____________ Smooth surface: Glossy | Semi-glossy | Matt Matt wrinkled appearanceElectrostatic post-painting with a special mixture of polyester resins, which ensure color stability over time; declared thickness not less than 80µm, nanotechnological pre-treatment for greater resistance to corrosion.Corrosion resistance class C4.

Page 2: Atena · Web viewFALSE CEILING “PLAN” Supply of a metal false ceiling for interiors, made with modular panels of the “ Atena Plan ” type, with size 600x600 mm and right edge,

STRETCHED METAL

rhomboid meshes: Q6 | Q8 | Q10square meshes: R6 | R8 | R10

RAL_____________ | NCS____________ Smooth surface: Glossy | Semi-glossy | MattElectrostatic post-painting with a special mixture of polyester resins, which ensure color stability over time; declared thickness not less than 80µm, nanotechnological pre-treatment for greater resistance to corrosion.Corrosion resistance class C4.

Panels will have the following characteristics: plain surface | perforated surface

Available perforations:

Parallel AP 0,75/2% AP 1/5% P AP 1,5/11% P AP 1,8/9,5% P AP 2/12,5% P AP 2,5/15% P AP 3/7,5% P AP Q4/20% P AP Q10/25% P AP Q10/34 % P

Diagonal AD 1/10% D(*) AD 1,5/22% D AD 1,8/19% D AD 2/25% D AD 2,5/30% D AD 3/15% D AD 3/51% D (**) AD 5/53% D (**) QUASAR (*) = only for 0,5mm thickness | (**) = not for 0,5mm thickness

Tissue Tweed Tweed Large Tweed Fine Tweed Unique Strip Piquet

Mesh R16x8/A2,5 R25x12,5/A2

Perforated area: Standard with plain frame | 400x400mm Other - specify____________

with thermoadhesive black acoustic tissue applied; fire reaction class: A1 A2s1d0

The false ceiling will have the following values: ɑw* __________e NCR* _________ * The acoustic characteristics of Atena products have been tested in accordance with ISO 10534, by an independent certified laboratory, the results on the acoustic absorption of the individual models have therefore been calculated using the ALPHACELLR software that uses the TIMM method for forecasting acoustic performance of pore-elastic multilayer materials. This is a system that takes into account the air resistivity, the porosity, the tortuosity and viscosity, the thermal characteristics and the permeability of the materials, which constitute the panel under test. The sound-absorbance and sound-impedance values of the panels depend on a series of factors such as the percentage of perforated area, the type of absorber / acoustic insulation coupled to the panel and the plenum value. Please therefore request Atena the values of ɑw and NCR or db to be reported in the specifications.

“Atena Metal Sound” AP1,8/19%D ɑw0,70 “Atena Metal Soft” AP1,8/19%D ɑw0,85“Atena Metal Sound” AP1,8/9,5%P ɑw0,75 “Atena Metal Soft” AP1,8/9,5%P ɑw0,85“Atena Metal Sound” AP1,5/22%D ɑw0,60“Atena Metal Sound” AP2/12,5%P ɑw0,65“Atena Metal Sound” AP2,5/30%D ɑw0,60

Page 3: Atena · Web viewFALSE CEILING “PLAN” Supply of a metal false ceiling for interiors, made with modular panels of the “ Atena Plan ” type, with size 600x600 mm and right edge,

STANDARD STRUCTUREPanels will be placed on Atena EASY Base 24 t-grid, made in galvanized steel and composed by 3700 mm T-shaped load-bearing profiles and 1200 and 600mm cross-pieces,

Structure Easy Base 24 with visible covering in pre-painted steel 0,30 mm thick, color: White | Black | Silver in C2 corrosion resistance class.

Structure Easy Base 24 TOTALLY WHITE, color: Whitein C3 corrosion resistance class.

Structure Easy Base 24 post-painted, color: RAL__________ | NCS__________in C4 corrosion resistance class.

Suspension of the false ceiling will be done with: Standard Ø4m hangers with double adjustment spring Standard hangers with Twister hook, patented by Atena S.p.A., made in tempered steel 10/10 mm with a breaking strength higher than 60Kg, (in seismic area maximumallowable load 45 Kg).

Perimeter profiles of the same material and finish of the panels with section shaped like: “L” 25x25mm | “L” 30x30mm | “C” 18x42x25mm

ANTISEISMIC STRUCTURE with ATENA KIT for PLENUM SPACE < 1,2 mPanels will be placed on Atena EASY Anti-seismic Base 24 t-grid, made in galvanized steel and composed by 3700 mm T-shaped load-bearing profiles and 1200 and 600mm cross-pieces,

Structure Easy Anti-seismic Base 24 with white visible covering in pre-painted steel in C2 corrosion resistance class. Structure Easy Anti-seismic Base 24 post-painted, RAL________ | NCS________in C4 corrosion resistance class.

Atena Bracing kit for plenum spaces lower than 1,2m consisting of a specific cross connection, holed bracing profiles to be fixed to the slab (4000mm length, to be cut on site), and fixing brackets. As an alternative, instead of using the fixing brackets, the holed bars can be bended on site with “FLEXA”, Atena’s specific bending tool, to be fixed directly to the slab.

Suspension of the false ceiling will be done with: Standard Ø4m hangers with double adjustment spring Standard hangers with Twister hook, patented by Atena S.p.A., made in temperedsteel 10/10 mm with a breaking strength higher than 60Kg, (in seismic area maximumallowable load 45 Kg).

Perimeter profiles of the same material and finish of the panels with section shaped like: “L” 25x25mm | “L” 30x30mm | “C” 18x42x25mm

Complete with Easy anti-seismic clamps to connect load-bearing profiles and cross-pieces to the perimeter. M4,1x13 screws to fix Easy Antiseismic clamp to “C” perimeter. Anti-seismic kits must be sized according to the building structural characteristics, its intended use and geographical location of the installation site. Anti-seismic Atena report is preparatory for commissioning. ANTISEISMIC STRUCTURE with ATENA KIT “BIG HEIGHTS” for PLENUM SPACE > 1,2 mPanels will be placed on Atena EASY Anti-seismic Base 24 t-grid, made in galvanized steel and composed

Page 4: Atena · Web viewFALSE CEILING “PLAN” Supply of a metal false ceiling for interiors, made with modular panels of the “ Atena Plan ” type, with size 600x600 mm and right edge,

by 3700 mm T-shaped load-bearing profiles and 1200 and 600mm cross-pieces,

Structure Easy Anti-seismic Base 24 with white visible covering in pre-painted steel in C2 corrosion resistance class. Structure Easy Anti-seismic Base 24 post-painted, RAL_______ | NCS _______in C4 corrosion resistance class.

Atena Bracing kit “Big Heights” for plenum spaces larger than 1,2m consisting of tubular with pitch holes and bracing connecting brackets, universal joints for fixing to the slab, a specific cross-joint to connect the kit to the Easy Anti-seismic structure and related screws (M8x70 and M4,2x13).

Suspension of the false ceiling will be done with: “Nonius” adjustable hangers

Perimeter profiles of the same material and finish of the panels with section shaped like: “L” 25x25mm | “L” 30x30mm | “C” 18x42x25mmComplete with Easy anti-seismic clamps to connect load-bearing profiles and cross-pieces to the perimeter. M4,1x13 screws to fix Easy Antiseismic clamp to “C” perimeter. Anti-seismic kits must be sized according to the building structural characteristics, its intended use and geographical location of the installation site. Anti-seismic Atena report is preparatory for commissioning.

The system complies with the Minimum Environmental Criteria DM 11 October 2017, the specific applicable standards UNI EN 13964 and 14195; does not release hazardous substances into the environment including formaldehyde. Painting and / or sublimation will be performed with substances free from Volatile Organic Compounds (VOCs). All products and components supplied will be accompanied by D.O.P. EC Declaration of Performance in accordance with the European regulation of construction products 305/2011. The artifacts will be recyclable and in their entirety derived from the use of materials from recycling processes, with content of recycled material, calculated for each type of product, compliant with CAM requirements and declared as required by the ISO 14021 standard. The false ceiling system contributes to obtaining credits for the design, construction and sustainable and efficient management of buildings according to the LEED protocol and according to the BREEAM and ITACA protocols for cross-cutting aspects.

NOTES: Atena Spa has adopted a quality management system in compliance with the UNI EN ISO 9001 standard.All Atena false ceilings are produced for indoor applications in compliance with the specific applicable technical standards and with the requirements of the “Norme Tecniche per le Costruzioni” NTC 2018 DM January 17, 2018 and relative circular; the performance properties declared in the relative D.O.P. are insured by Atena S.p.A. provided that the false ceilings are installed in the environmental conditions, for which they have been designed and have been subjected to the normal recommended maintenance activities. Specifically, false ceilings as non-structural construction elements must be appropriately sized in order to withstand with adequate security all those actions that can induce states of solicitation to the building; thermal, humidity, etc., in relation to the installation site, the intended use of the building and the technical characteristics of the project. It is therefore recommended to check with the Atena technical office the specific environmental conditions to which the product will be subjected in order to choose the most suitable materials for the installation site. In the case of outdoor installation, false ceilings are not within the scope of a harmonized technical standard and therefore are not subject to regulation 305/2011. They are in any case subjected to the NTC 2018 and to the safety checks of civil constructions and therefore they must be specifically sized according to the environmental conditions of the installation site, to the structural characteristics of the building and to the project specifications.