Post on 07-Aug-2015
DET NORSKE VERITAS
SURVEY REPORT
DNV Id. No.: 09757
Ref.: KYUZRI Ord.Nr.: 10990302
Name of Ship
WAWASAN MURNI
Owner
WAWASAN BULK SERVICES SDN. BHD.
Original to DTP
Copy to owner
Copy to Ship
Stamp Place: Date: SINGAOPRE 1999-05-15 ..............................................................................................................................................................................................................................................................
KYUZRI ......................................................................................................................................................................................................................................................... Surveyor’s name (Capital Letters) Surveyor’s signature
If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision “Det
Norske Veritas” shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas.
DET NORSKE VERITAS AS, VERITASVEIEN 1, N-1322 HØVIK, NORWAY TEL.INT: +47 67 57 99 00, TELEFAX: +47 67 57 99 11 Form No.: 40.9a Issue: January 98 Page 1 of 2
Survey requested by : Owners Representative
Place of Survey : Singapore
Date of survey : 1999-05-15
POSPONEMENT OF RCH, BOTTOM & STATUTORY SURVEYS
AND CONTINOUS MACHINERY SURVEY
Scope
This is to confirm that, Undersigned Surveyor attended onboard the above vessel and had carried out the
following surveys:
Postponement of RCH,sighting survey
Postponement of Bottom Survey, in water survey
Postponement of Load Line Cert., renewal ,sigthing survey
Postponement of Safety Contruction Cert., renewal, sighting survey
Postponement of IOPP Cert.,complete ,sighting survey
Postponement of NLS Cert.,renewal , sighting survey
Safety Equipment Cert., annual survey
Continuos Machinery Survey
Deletion of CC 138
Postponement of CC 100, CC 114, CC 123 and CC139
Findings
Following items were found not in order:
Main Class/Tanker for Oil:
1. Poop deck platings found thinning down. 2. P,C,S Generator and Main Engine covered with lube oil at various locations. An indication that both
machinery had experienced leaking of lube oil while running.
3. Self closing weight of F.O. tank short sounding pipe at lower platform was missing.
4. Insulation of F.O. pipe from service tank to main engine was partly damaged.
5. Port engine room ventilator mushroom found thinned and holed.
6. All pipe supports and U-bolt clamps on main deck were badly thinned/wasted.
7. Several steps of external ladders at poop decks found badly thinned.
8. Air pipe on main deck was leaking and some sections were badly corrode
SURVEY REPORT (ctd.) DNV Id. No.: 09757
Ref.: KYUZRI
Order No.: 10990302
Name of Ship WAWASAN MURNI
Owner WAWASAN BULK SERVICES SDN. BHD.
DET NORSKE VERITAS AS, VERITASVEIEN 1, N-1322 HØVIK, NORWAY TEL.INT: +47 67 57 99 00, TELEFAX: +47 67 57 99 11
Form No.: 40.9a Issue: January 98 Page 2 of 2
9. Hydraulic pipes at emergency generator room bulkhead and at main deck found badly thinned. Some
sections had been repaired and still in progress.
10. Pillar and brackets for securing the aft crane’s boom/block were found badly thinned.
11. Tranverse walkway at fwd main deck was completely deteriorated. Handrails, floor grating, ladder
steps,brackets etc. were badly corroded and thinned.
12. Inner plating of P&S chain locker found holed/thinned. As the above deficiencies have not been rectified, a condition of class given (see form CSE.001)
Safet Eqpt. Certificate
1. While testing of main and emergency fire pump, fire line at main deck found leaking due to hole/wasted.
2. Stbd. fire hose at main deck that was using for testing found leaking due to hole.
As the above deficiencies have not been rectified, a condition of class given (see form CSE.001)
IOPP Cert.
1. Side plate of stbd manifolds drip tray found thinned/holed.
2. Aft drip tray for stern loading/unloading arrangement found thinned/wasted.
As the above deficiencies have not been rectified, a condition of class given (see form CSE.001)
Load Line Cert.
1. P&S air vent heads at funnel bulkhead were badly damaged due to corrosion.
2. P&S air vent heads at cargo pump room bulkhead found thinned/wasted.
3. Air vent pipe at port forecastle deck was temporary repaired by cement.
4. Vent flap at emergency generator room was missing. Flap coaming was badly wasted.
5. Bulwark face plates and bracket flanges at forecastle and fwd P&S bulwarks found wasted/thinned.
As the above deficiencies have not been rectified, a condition of class given (see form CSE.001)
Continuos machinery survey:
1. CW pipe connector of stbd. generator found leaking.
2. CW pump of port generator found leaking. 3. Generator L.O. Cooler SW cooling pipe found leaking.
As the above deficiencies have not been rectified, a condition of class given (see form CSE.001)
Bottom in water survey:
- Bottom in water survey satisfactory carried by diver.
- Fishing rope entangled at tailshaft iwo rope guard had been removed.
Deletion of CC 138
Fixed installation CO2 bottles were hydraulic tested in 1994/04/07. All bottles found marked with test
date and pressure. Test certificate sighted onboard. Accordingly condition of class is now deleted. (see
form CSE.001)
Posponement of CC 100, CC 114, CC 123 and CC 139.
Above CCs are now postponed until 1999-07-15 upon satisfactory results of verification.
Conclusion
Upon satisfactory completion of examination, relevant renewal/complete surveys were extended. Interim
Certificate of Class and Short term certificates issued and valid until 1999-07-15. Safety Equipment
Certificate was endorsed.
SURVEY REPORT (ctd.) DNV Id. No.: 09757
Ref.: KYUZRI
Order No.: 10990302
Name of Ship WAWASAN MURNI
Owner WAWASAN BULK SERVICES SDN. BHD.
DET NORSKE VERITAS AS, VERITASVEIEN 1, N-1322 HØVIK, NORWAY TEL.INT: +47 67 57 99 00, TELEFAX: +47 67 57 99 11
Form No.: 40.9a Issue: January 98 Page 3 of 2