Page 1: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

VersaView 5100 Industrial MonitorsCatalog Numbers 6200M-12WBN 6200M-15WBN 6200M-19WBN 6200M-22WBN

User ManualOriginal Instructions

Important User Information

Read this document and the documents listed in the additional resources section about installation configuration and operation of this equipment before you install configure operate or maintain this product Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes laws and standards

Activities including installation adjustments putting into service use assembly disassembly and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice

If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired

In no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment

The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams

No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual

Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited

Throughout this manual when necessary we use notes to make you aware of safety considerations

Labels may also be on or inside the equipment to provide specific precautions

WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment which may lead to personal injury or death property damage or economic loss

ATTENTION Identifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss Attentions help you identify a hazard avoid a hazard and recognize the consequence

IMPORTANT Identifies information that is critical for successful application and understanding of the product

SHOCK HAZARD Labels may be on or inside the equipment for example a drive or motor to alert people that dangerous voltage may be present

BURN HAZARD Labels may be on or inside the equipment for example a drive or motor to alert people that surfaces may reach dangerous temperatures

ARC FLASH HAZARD Labels may be on or inside the equipment for example a motor control center to alert people to potential Arc Flash Arc Flash will cause severe injury or death Wear proper Personal Protective Equipment (PPE) Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE)

Table of Contents

PrefaceAbbreviations 7Additional Resources 8

Chapter 1Monitor Features Monitor Options 9

Hardware Features 10

Chapter 2Install the Monitor Before You Begin 11

Parts List 11Installation Precautions 12

Environment and Enclosure Information 12European Union Directive Compliance 12

Installation Guidelines 13Enclosure Guidelines 14

Mounting Clearance Requirements 14Monitor Dimensions 15Required Tools 15Install the Monitor 16

Panel Mounting Guidelines 16Panel Cutout Dimensions 16Mount the Monitor in a Panel 17VESA Mount a Monitor 19

Connect Peripherals 20Connect Power 20

Connect AC Power 21Connect DC Power 21

Chapter 3Configure the Display Set the Monitor Type 23

Check and Change the Display Resolution 23Touch Screen Precautions 24

Touch Screen Driver Software 24Adjust the Display Brightness 25

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 3

Table of Contents

Chapter 4Clean the Monitor Clean the Monitor 27

Clean the Integrated Display 27Clean the Air Openings and Cooling Fins 28Remove Paint and Grease from Bezel 28

Chapter 5Troubleshoot the Monitor Troubleshooting 29

Ship or Transport the Monitor 30Dispose of the Monitor 30

4 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Table of Contents

Notes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 5

Table of Contents

Notes

6 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Preface

This manual is a user guide for VersaViewreg 5100 industrial monitors It provides procedures to the following

bull Install the monitorbull Make monitor connectionsbull Operate the monitorbull Troubleshoot the monitor

Abbreviations This publication can use the following abbreviations

Abbr Meaning Abbr Meaning

BIOS Basic inputoutput system PCB Printed circuit board

CF CompactFlash PCDC Product Compatibility and Download Center

CMOS Complementary metal oxide semiconductor

PCI Peripheral component interconnect

COM Communication (serial port interface) PCIe Peripheral component interconnect express

DDR Double data rate (RAM) PELV Protective extra-low voltage

DIMM Dual in-line memory module POST Power on self-test

DP DisplayPort (digital display interface) RAM Random access memory

DVI Digital video interface RTC Real-time clock

EEA European Environment Agency SELV Safety extra low voltage

EMC Electromagnetic compatibility SSD Solid-state drive

ESD Electrostatic discharge TFT Thin film transistor

IEC International Engineering Consortium UEFI Universal extensible firmware interface

LAN Local area network USB Universal serial bus

NDM Non-display model UPS Uninterruptible power source

NEMA National Electrical Manufacturers Association

VGA Video graphics array

PCAP Protective capacitive (touch screen)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7

Preface

Additional Resources These documents contain additional information about related products from Rockwell Automation

You can view or download publications athttpwwwrockwellautomationcomgloballiterature-libraryoverviewpage To order paper copies of technical documentation contact your local Allen-Bradley distributor or Rockwell Automation sales representative

Resource Description

Industrial Computer and Monitor Specifications Technical Data publication IC-TD001

Provides technical specifications about the VersaView 5100 industrial monitors

Industrial Automation Wiring and Grounding Guidelines publication 1770-41

Provides general guidelines for installing a Rockwell Automation industrial system

Product Certifications websitehttpwwwrockwellautomationcomglobalcertificationoverviewpage

Provides declarations of conformity certificates and other certification details

8 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN ltFEFF004200720075006700200069006e0064007300740069006c006c0069006e006700650072006e0065002000740069006c0020006100740020006f007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e007400650072002000740069006c0020006b00760061006c00690074006500740073007500640073006b007200690076006e0069006e006700200065006c006c006500720020006b006f007200720065006b007400750072006c00e60073006e0069006e0067002e0020004400650020006f007000720065007400740065006400650020005000440046002d0064006f006b0075006d0065006e0074006500720020006b0061006e002000e50062006e00650073002000690020004100630072006f00620061007400200065006c006c006500720020004100630072006f006200610074002000520065006100640065007200200035002e00300020006f00670020006e0079006500720065002egt DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 2: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Important User Information

Read this document and the documents listed in the additional resources section about installation configuration and operation of this equipment before you install configure operate or maintain this product Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes laws and standards

Activities including installation adjustments putting into service use assembly disassembly and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice

If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired

In no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment

The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams

No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual

Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited

Throughout this manual when necessary we use notes to make you aware of safety considerations

Labels may also be on or inside the equipment to provide specific precautions

WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment which may lead to personal injury or death property damage or economic loss

ATTENTION Identifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss Attentions help you identify a hazard avoid a hazard and recognize the consequence

IMPORTANT Identifies information that is critical for successful application and understanding of the product

SHOCK HAZARD Labels may be on or inside the equipment for example a drive or motor to alert people that dangerous voltage may be present

BURN HAZARD Labels may be on or inside the equipment for example a drive or motor to alert people that surfaces may reach dangerous temperatures

ARC FLASH HAZARD Labels may be on or inside the equipment for example a motor control center to alert people to potential Arc Flash Arc Flash will cause severe injury or death Wear proper Personal Protective Equipment (PPE) Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE)

Table of Contents

PrefaceAbbreviations 7Additional Resources 8

Chapter 1Monitor Features Monitor Options 9

Hardware Features 10

Chapter 2Install the Monitor Before You Begin 11

Parts List 11Installation Precautions 12

Environment and Enclosure Information 12European Union Directive Compliance 12

Installation Guidelines 13Enclosure Guidelines 14

Mounting Clearance Requirements 14Monitor Dimensions 15Required Tools 15Install the Monitor 16

Panel Mounting Guidelines 16Panel Cutout Dimensions 16Mount the Monitor in a Panel 17VESA Mount a Monitor 19

Connect Peripherals 20Connect Power 20

Connect AC Power 21Connect DC Power 21

Chapter 3Configure the Display Set the Monitor Type 23

Check and Change the Display Resolution 23Touch Screen Precautions 24

Touch Screen Driver Software 24Adjust the Display Brightness 25

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 3

Table of Contents

Chapter 4Clean the Monitor Clean the Monitor 27

Clean the Integrated Display 27Clean the Air Openings and Cooling Fins 28Remove Paint and Grease from Bezel 28

Chapter 5Troubleshoot the Monitor Troubleshooting 29

Ship or Transport the Monitor 30Dispose of the Monitor 30

4 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Table of Contents

Notes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 5

Table of Contents

Notes

6 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Preface

This manual is a user guide for VersaViewreg 5100 industrial monitors It provides procedures to the following

bull Install the monitorbull Make monitor connectionsbull Operate the monitorbull Troubleshoot the monitor

Abbreviations This publication can use the following abbreviations

Abbr Meaning Abbr Meaning

BIOS Basic inputoutput system PCB Printed circuit board

CF CompactFlash PCDC Product Compatibility and Download Center

CMOS Complementary metal oxide semiconductor

PCI Peripheral component interconnect

COM Communication (serial port interface) PCIe Peripheral component interconnect express

DDR Double data rate (RAM) PELV Protective extra-low voltage

DIMM Dual in-line memory module POST Power on self-test

DP DisplayPort (digital display interface) RAM Random access memory

DVI Digital video interface RTC Real-time clock

EEA European Environment Agency SELV Safety extra low voltage

EMC Electromagnetic compatibility SSD Solid-state drive

ESD Electrostatic discharge TFT Thin film transistor

IEC International Engineering Consortium UEFI Universal extensible firmware interface

LAN Local area network USB Universal serial bus

NDM Non-display model UPS Uninterruptible power source

NEMA National Electrical Manufacturers Association

VGA Video graphics array

PCAP Protective capacitive (touch screen)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7

Preface

Additional Resources These documents contain additional information about related products from Rockwell Automation

You can view or download publications athttpwwwrockwellautomationcomgloballiterature-libraryoverviewpage To order paper copies of technical documentation contact your local Allen-Bradley distributor or Rockwell Automation sales representative

Resource Description

Industrial Computer and Monitor Specifications Technical Data publication IC-TD001

Provides technical specifications about the VersaView 5100 industrial monitors

Industrial Automation Wiring and Grounding Guidelines publication 1770-41

Provides general guidelines for installing a Rockwell Automation industrial system

Product Certifications websitehttpwwwrockwellautomationcomglobalcertificationoverviewpage

Provides declarations of conformity certificates and other certification details

8 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR ltFEFF004200720075006b00200064006900730073006500200069006e006e007300740069006c006c0069006e00670065006e0065002000740069006c002000e50020006f0070007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740065007200200066006f00720020007500740073006b00720069006600740020006100760020006800f800790020006b00760061006c00690074006500740020007000e500200062006f007200640073006b0072006900760065007200200065006c006c00650072002000700072006f006f006600650072002e0020005000440046002d0064006f006b0075006d0065006e00740065006e00650020006b0061006e002000e50070006e00650073002000690020004100630072006f00620061007400200065006c006c00650072002000410064006f00620065002000520065006100640065007200200035002e003000200065006c006c00650072002000730065006e006500720065002egt PTB ltFEFF005500740069006c0069007a006500200065007300730061007300200063006f006e00660069006700750072006100e700f50065007300200064006500200066006f0072006d00610020006100200063007200690061007200200064006f00630075006d0065006e0074006f0073002000410064006f0062006500200050004400460020007000610072006100200069006d0070007200650073007300f5006500730020006400650020007100750061006c0069006400610064006500200065006d00200069006d00700072006500730073006f0072006100730020006400650073006b0074006f00700020006500200064006900730070006f00730069007400690076006f0073002000640065002000700072006f00760061002e0020004f007300200064006f00630075006d0065006e0074006f00730020005000440046002000630072006900610064006f007300200070006f00640065006d0020007300650072002000610062006500720074006f007300200063006f006d0020006f0020004100630072006f006200610074002000650020006f002000410064006f00620065002000520065006100640065007200200035002e0030002000650020007600650072007300f50065007300200070006f00730074006500720069006f007200650073002egt SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 3: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Table of Contents

PrefaceAbbreviations 7Additional Resources 8

Chapter 1Monitor Features Monitor Options 9

Hardware Features 10

Chapter 2Install the Monitor Before You Begin 11

Parts List 11Installation Precautions 12

Environment and Enclosure Information 12European Union Directive Compliance 12

Installation Guidelines 13Enclosure Guidelines 14

Mounting Clearance Requirements 14Monitor Dimensions 15Required Tools 15Install the Monitor 16

Panel Mounting Guidelines 16Panel Cutout Dimensions 16Mount the Monitor in a Panel 17VESA Mount a Monitor 19

Connect Peripherals 20Connect Power 20

Connect AC Power 21Connect DC Power 21

Chapter 3Configure the Display Set the Monitor Type 23

Check and Change the Display Resolution 23Touch Screen Precautions 24

Touch Screen Driver Software 24Adjust the Display Brightness 25

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 3

Table of Contents

Chapter 4Clean the Monitor Clean the Monitor 27

Clean the Integrated Display 27Clean the Air Openings and Cooling Fins 28Remove Paint and Grease from Bezel 28

Chapter 5Troubleshoot the Monitor Troubleshooting 29

Ship or Transport the Monitor 30Dispose of the Monitor 30

4 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Table of Contents

Notes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 5

Table of Contents

Notes

6 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Preface

This manual is a user guide for VersaViewreg 5100 industrial monitors It provides procedures to the following

bull Install the monitorbull Make monitor connectionsbull Operate the monitorbull Troubleshoot the monitor

Abbreviations This publication can use the following abbreviations

Abbr Meaning Abbr Meaning

BIOS Basic inputoutput system PCB Printed circuit board

CF CompactFlash PCDC Product Compatibility and Download Center

CMOS Complementary metal oxide semiconductor

PCI Peripheral component interconnect

COM Communication (serial port interface) PCIe Peripheral component interconnect express

DDR Double data rate (RAM) PELV Protective extra-low voltage

DIMM Dual in-line memory module POST Power on self-test

DP DisplayPort (digital display interface) RAM Random access memory

DVI Digital video interface RTC Real-time clock

EEA European Environment Agency SELV Safety extra low voltage

EMC Electromagnetic compatibility SSD Solid-state drive

ESD Electrostatic discharge TFT Thin film transistor

IEC International Engineering Consortium UEFI Universal extensible firmware interface

LAN Local area network USB Universal serial bus

NDM Non-display model UPS Uninterruptible power source

NEMA National Electrical Manufacturers Association

VGA Video graphics array

PCAP Protective capacitive (touch screen)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7

Preface

Additional Resources These documents contain additional information about related products from Rockwell Automation

You can view or download publications athttpwwwrockwellautomationcomgloballiterature-libraryoverviewpage To order paper copies of technical documentation contact your local Allen-Bradley distributor or Rockwell Automation sales representative

Resource Description

Industrial Computer and Monitor Specifications Technical Data publication IC-TD001

Provides technical specifications about the VersaView 5100 industrial monitors

Industrial Automation Wiring and Grounding Guidelines publication 1770-41

Provides general guidelines for installing a Rockwell Automation industrial system

Product Certifications websitehttpwwwrockwellautomationcomglobalcertificationoverviewpage

Provides declarations of conformity certificates and other certification details

8 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP 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 FRA ltFEFF005500740069006c006900730065007a00200063006500730020006f007000740069006f006e00730020006100660069006e00200064006500200063007200e900650072002000640065007300200064006f00630075006d0065006e00740073002000410064006f00620065002000500044004600200070006f007500720020006400650073002000e90070007200650075007600650073002000650074002000640065007300200069006d007000720065007300730069006f006e00730020006400650020006800610075007400650020007100750061006c0069007400e90020007300750072002000640065007300200069006d007000720069006d0061006e0074006500730020006400650020006200750072006500610075002e0020004c0065007300200064006f00630075006d0065006e00740073002000500044004600200063007200e900e90073002000700065007500760065006e0074002000ea0074007200650020006f007500760065007200740073002000640061006e00730020004100630072006f006200610074002c002000610069006e00730069002000710075002700410064006f00620065002000520065006100640065007200200035002e0030002000650074002000760065007200730069006f006e007300200075006c007400e90072006900650075007200650073002egt ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 4: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Table of Contents

Chapter 4Clean the Monitor Clean the Monitor 27

Clean the Integrated Display 27Clean the Air Openings and Cooling Fins 28Remove Paint and Grease from Bezel 28

Chapter 5Troubleshoot the Monitor Troubleshooting 29

Ship or Transport the Monitor 30Dispose of the Monitor 30

4 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Table of Contents

Notes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 5

Table of Contents

Notes

6 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Preface

This manual is a user guide for VersaViewreg 5100 industrial monitors It provides procedures to the following

bull Install the monitorbull Make monitor connectionsbull Operate the monitorbull Troubleshoot the monitor

Abbreviations This publication can use the following abbreviations

Abbr Meaning Abbr Meaning

BIOS Basic inputoutput system PCB Printed circuit board

CF CompactFlash PCDC Product Compatibility and Download Center

CMOS Complementary metal oxide semiconductor

PCI Peripheral component interconnect

COM Communication (serial port interface) PCIe Peripheral component interconnect express

DDR Double data rate (RAM) PELV Protective extra-low voltage

DIMM Dual in-line memory module POST Power on self-test

DP DisplayPort (digital display interface) RAM Random access memory

DVI Digital video interface RTC Real-time clock

EEA European Environment Agency SELV Safety extra low voltage

EMC Electromagnetic compatibility SSD Solid-state drive

ESD Electrostatic discharge TFT Thin film transistor

IEC International Engineering Consortium UEFI Universal extensible firmware interface

LAN Local area network USB Universal serial bus

NDM Non-display model UPS Uninterruptible power source

NEMA National Electrical Manufacturers Association

VGA Video graphics array

PCAP Protective capacitive (touch screen)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7

Preface

Additional Resources These documents contain additional information about related products from Rockwell Automation

You can view or download publications athttpwwwrockwellautomationcomgloballiterature-libraryoverviewpage To order paper copies of technical documentation contact your local Allen-Bradley distributor or Rockwell Automation sales representative

Resource Description

Industrial Computer and Monitor Specifications Technical Data publication IC-TD001

Provides technical specifications about the VersaView 5100 industrial monitors

Industrial Automation Wiring and Grounding Guidelines publication 1770-41

Provides general guidelines for installing a Rockwell Automation industrial system

Product Certifications websitehttpwwwrockwellautomationcomglobalcertificationoverviewpage

Provides declarations of conformity certificates and other certification details

8 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 5: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Table of Contents

Notes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 5

Table of Contents

Notes

6 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Preface

This manual is a user guide for VersaViewreg 5100 industrial monitors It provides procedures to the following

bull Install the monitorbull Make monitor connectionsbull Operate the monitorbull Troubleshoot the monitor

Abbreviations This publication can use the following abbreviations

Abbr Meaning Abbr Meaning

BIOS Basic inputoutput system PCB Printed circuit board

CF CompactFlash PCDC Product Compatibility and Download Center

CMOS Complementary metal oxide semiconductor

PCI Peripheral component interconnect

COM Communication (serial port interface) PCIe Peripheral component interconnect express

DDR Double data rate (RAM) PELV Protective extra-low voltage

DIMM Dual in-line memory module POST Power on self-test

DP DisplayPort (digital display interface) RAM Random access memory

DVI Digital video interface RTC Real-time clock

EEA European Environment Agency SELV Safety extra low voltage

EMC Electromagnetic compatibility SSD Solid-state drive

ESD Electrostatic discharge TFT Thin film transistor

IEC International Engineering Consortium UEFI Universal extensible firmware interface

LAN Local area network USB Universal serial bus

NDM Non-display model UPS Uninterruptible power source

NEMA National Electrical Manufacturers Association

VGA Video graphics array

PCAP Protective capacitive (touch screen)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7

Preface

Additional Resources These documents contain additional information about related products from Rockwell Automation

You can view or download publications athttpwwwrockwellautomationcomgloballiterature-libraryoverviewpage To order paper copies of technical documentation contact your local Allen-Bradley distributor or Rockwell Automation sales representative

Resource Description

Industrial Computer and Monitor Specifications Technical Data publication IC-TD001

Provides technical specifications about the VersaView 5100 industrial monitors

Industrial Automation Wiring and Grounding Guidelines publication 1770-41

Provides general guidelines for installing a Rockwell Automation industrial system

Product Certifications websitehttpwwwrockwellautomationcomglobalcertificationoverviewpage

Provides declarations of conformity certificates and other certification details

8 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 6: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Table of Contents

Notes

6 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Preface

This manual is a user guide for VersaViewreg 5100 industrial monitors It provides procedures to the following

bull Install the monitorbull Make monitor connectionsbull Operate the monitorbull Troubleshoot the monitor

Abbreviations This publication can use the following abbreviations

Abbr Meaning Abbr Meaning

BIOS Basic inputoutput system PCB Printed circuit board

CF CompactFlash PCDC Product Compatibility and Download Center

CMOS Complementary metal oxide semiconductor

PCI Peripheral component interconnect

COM Communication (serial port interface) PCIe Peripheral component interconnect express

DDR Double data rate (RAM) PELV Protective extra-low voltage

DIMM Dual in-line memory module POST Power on self-test

DP DisplayPort (digital display interface) RAM Random access memory

DVI Digital video interface RTC Real-time clock

EEA European Environment Agency SELV Safety extra low voltage

EMC Electromagnetic compatibility SSD Solid-state drive

ESD Electrostatic discharge TFT Thin film transistor

IEC International Engineering Consortium UEFI Universal extensible firmware interface

LAN Local area network USB Universal serial bus

NDM Non-display model UPS Uninterruptible power source

NEMA National Electrical Manufacturers Association

VGA Video graphics array

PCAP Protective capacitive (touch screen)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7

Preface

Additional Resources These documents contain additional information about related products from Rockwell Automation

You can view or download publications athttpwwwrockwellautomationcomgloballiterature-libraryoverviewpage To order paper copies of technical documentation contact your local Allen-Bradley distributor or Rockwell Automation sales representative

Resource Description

Industrial Computer and Monitor Specifications Technical Data publication IC-TD001

Provides technical specifications about the VersaView 5100 industrial monitors

Industrial Automation Wiring and Grounding Guidelines publication 1770-41

Provides general guidelines for installing a Rockwell Automation industrial system

Product Certifications websitehttpwwwrockwellautomationcomglobalcertificationoverviewpage

Provides declarations of conformity certificates and other certification details

8 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 7: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Preface

This manual is a user guide for VersaViewreg 5100 industrial monitors It provides procedures to the following

bull Install the monitorbull Make monitor connectionsbull Operate the monitorbull Troubleshoot the monitor

Abbreviations This publication can use the following abbreviations

Abbr Meaning Abbr Meaning

BIOS Basic inputoutput system PCB Printed circuit board

CF CompactFlash PCDC Product Compatibility and Download Center

CMOS Complementary metal oxide semiconductor

PCI Peripheral component interconnect

COM Communication (serial port interface) PCIe Peripheral component interconnect express

DDR Double data rate (RAM) PELV Protective extra-low voltage

DIMM Dual in-line memory module POST Power on self-test

DP DisplayPort (digital display interface) RAM Random access memory

DVI Digital video interface RTC Real-time clock

EEA European Environment Agency SELV Safety extra low voltage

EMC Electromagnetic compatibility SSD Solid-state drive

ESD Electrostatic discharge TFT Thin film transistor

IEC International Engineering Consortium UEFI Universal extensible firmware interface

LAN Local area network USB Universal serial bus

NDM Non-display model UPS Uninterruptible power source

NEMA National Electrical Manufacturers Association

VGA Video graphics array

PCAP Protective capacitive (touch screen)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7

Preface

Additional Resources These documents contain additional information about related products from Rockwell Automation

You can view or download publications athttpwwwrockwellautomationcomgloballiterature-libraryoverviewpage To order paper copies of technical documentation contact your local Allen-Bradley distributor or Rockwell Automation sales representative

Resource Description

Industrial Computer and Monitor Specifications Technical Data publication IC-TD001

Provides technical specifications about the VersaView 5100 industrial monitors

Industrial Automation Wiring and Grounding Guidelines publication 1770-41

Provides general guidelines for installing a Rockwell Automation industrial system

Product Certifications websitehttpwwwrockwellautomationcomglobalcertificationoverviewpage

Provides declarations of conformity certificates and other certification details

8 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN ltFEFF004200720075006700200069006e0064007300740069006c006c0069006e006700650072006e0065002000740069006c0020006100740020006f007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e007400650072002000740069006c0020006b00760061006c00690074006500740073007500640073006b007200690076006e0069006e006700200065006c006c006500720020006b006f007200720065006b007400750072006c00e60073006e0069006e0067002e0020004400650020006f007000720065007400740065006400650020005000440046002d0064006f006b0075006d0065006e0074006500720020006b0061006e002000e50062006e00650073002000690020004100630072006f00620061007400200065006c006c006500720020004100630072006f006200610074002000520065006100640065007200200035002e00300020006f00670020006e0079006500720065002egt DEU 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 ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 8: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Preface

Additional Resources These documents contain additional information about related products from Rockwell Automation

You can view or download publications athttpwwwrockwellautomationcomgloballiterature-libraryoverviewpage To order paper copies of technical documentation contact your local Allen-Bradley distributor or Rockwell Automation sales representative

Resource Description

Industrial Computer and Monitor Specifications Technical Data publication IC-TD001

Provides technical specifications about the VersaView 5100 industrial monitors

Industrial Automation Wiring and Grounding Guidelines publication 1770-41

Provides general guidelines for installing a Rockwell Automation industrial system

Product Certifications websitehttpwwwrockwellautomationcomglobalcertificationoverviewpage

Provides declarations of conformity certificates and other certification details

8 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 9: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 1

Monitor Features

The VersaViewreg 5100 monitors have an edge-to-edge all glass ten-point multi-touch screen that can also be operated with gloves The touch screens are precalibrated so that recalibration is not necessary These monitors are optimized to work with the VersaView 5000 computer and thin client portfolio to create a visualization maintenance control or information computing solution

The monitors offer the following featuresbull 121 156 185 or 215-inch active matrix displaybull Native video resolutions from 1280 x 800 to 1920 x 1080 (full HD)bull Wide viewing angle with antiglare coatingbull Windows and Linux compatiblebull DC input power

Monitor Options Table 1 describes what options ship currently with VersaView 5100 industrial monitors To identify your monitorrsquos configuration compare the nameplate label on your monitor to Table 1

A comparative summary of monitor features is in publication IC-TD001 Industrial Computer and Monitors Specifications Technical Data

Table 1 - VersaView 5100 Monitor Catalog Numbers and Display Sizes

Topic Page

Monitor Options 9

Hardware Features 10

Cat NoDisplay Size

(in)Resolution

(W x H pixels)Brightness

(cdm2) BezelTouch Screen

6200M-12WBN 121 1280 x 800 400 Tempered Glass and Stainless

Steel

PCAP

6200M-15WBN 156 1366 x 768

6200M-19WBN 185 450

6200M-22WBN 215 1920 x 1080 300

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 9

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN ltFEFF004200720075006700200069006e0064007300740069006c006c0069006e006700650072006e0065002000740069006c0020006100740020006f007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e007400650072002000740069006c0020006b00760061006c00690074006500740073007500640073006b007200690076006e0069006e006700200065006c006c006500720020006b006f007200720065006b007400750072006c00e60073006e0069006e0067002e0020004400650020006f007000720065007400740065006400650020005000440046002d0064006f006b0075006d0065006e0074006500720020006b0061006e002000e50062006e00650073002000690020004100630072006f00620061007400200065006c006c006500720020004100630072006f006200610074002000520065006100640065007200200035002e00300020006f00670020006e0079006500720065002egt DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 10: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 1 Monitor Features

Hardware Features Figure 1 shows the hardware features of VersaView 5100 monitors

Figure 1 - VersaView 5100 Hardware Features

Item Component Item Component

1 Mounting clip slot(1)

(1) Depending on the monitor model slots accommodate 8 to 14 mounting clips

4 USB port

2 DisplayPort 5 24V DC power input connection

3 DVI-I port(2)

(2) Can be used for VGA with DVI-to-VGA adapter cat no 6189V-DVIVGA which is sold separately

6 Ground screw

2

1

3 4 5 6

10 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 11: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 2

Install the Monitor

Before You Begin Before you unpack the monitor inspect the shipping carton for damage If damage is visible immediately contact the shipper and request assistance Otherwise proceed with unpacking

Keep the original packing material in case you need to return the monitor for repair or transport it to another location

Parts List The monitors ship with the following items

Topic Page

Before You Begin 11

Parts List 11

Installation Precautions 12

Installation Guidelines 13

Mounting Clearance Requirements 14

Monitor Dimensions 15

Required Tools 15

Install the Monitor 16

Connect Peripherals 20

Connect Power 20

Item Description

Hardware bull Mounting clipsbull DC terminal block

Documents bull VersaViewreg 5100 Industrial Monitors and VersaView 5000 Thin Clients Industrial Computers and Accessories Product Information publication 6200-PC001

bull VersaView 5000 Thin Client and Integrated Display Industrial Computers Cutout Template publication 6200-DS001

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 11

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP 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 FRA ltFEFF005500740069006c006900730065007a00200063006500730020006f007000740069006f006e00730020006100660069006e00200064006500200063007200e900650072002000640065007300200064006f00630075006d0065006e00740073002000410064006f00620065002000500044004600200070006f007500720020006400650073002000e90070007200650075007600650073002000650074002000640065007300200069006d007000720065007300730069006f006e00730020006400650020006800610075007400650020007100750061006c0069007400e90020007300750072002000640065007300200069006d007000720069006d0061006e0074006500730020006400650020006200750072006500610075002e0020004c0065007300200064006f00630075006d0065006e00740073002000500044004600200063007200e900e90073002000700065007500760065006e0074002000ea0074007200650020006f007500760065007200740073002000640061006e00730020004100630072006f006200610074002c002000610069006e00730069002000710075002700410064006f00620065002000520065006100640065007200200035002e0030002000650074002000760065007200730069006f006e007300200075006c007400e90072006900650075007200650073002egt ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB ltFEFF005500740069006c0069007a006500200065007300730061007300200063006f006e00660069006700750072006100e700f50065007300200064006500200066006f0072006d00610020006100200063007200690061007200200064006f00630075006d0065006e0074006f0073002000410064006f0062006500200050004400460020007000610072006100200069006d0070007200650073007300f5006500730020006400650020007100750061006c0069006400610064006500200065006d00200069006d00700072006500730073006f0072006100730020006400650073006b0074006f00700020006500200064006900730070006f00730069007400690076006f0073002000640065002000700072006f00760061002e0020004f007300200064006f00630075006d0065006e0074006f00730020005000440046002000630072006900610064006f007300200070006f00640065006d0020007300650072002000610062006500720074006f007300200063006f006d0020006f0020004100630072006f006200610074002000650020006f002000410064006f00620065002000520065006100640065007200200035002e0030002000650020007600650072007300f50065007300200070006f00730074006500720069006f007200650073002egt SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 12: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 2 Install the Monitor

Installation Precautions Read and follow these precautions before you install the monitor

Environment and Enclosure Information

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking A copy of the declaration of the conformity is available at httpswwwrockwellautomationcomglobalcertificationoverviewpage

ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications (as defined in IEC 60664-1) at altitudes up to 2000 m (6561 ft) without deratingThis equipment is considered Group 1 Class A industrial equipment according to IECCISPR 22 Without appropriate precautions there can be potential difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbanceThis equipment is UL Listed However to meet some regulatory requirements the monitor must be mounted in an enclosure that is suitably designed for environmental conditions that can be presentAll VersaView industrial monitors are shipped with a gasketed bezel to meet specified NEMA UL Type and IEC IP ratings only when mounted in a panel or enclosure with an equivalent ratingIn addition to this publication see the followingbull Industrial Automation Wiring and Grounding Guidelines publication

1770-41 for more installation requirementsbull NEMA 250 and IEC 60529 as applicable for explanations of the degrees of

protection provided by enclosures

ATTENTION This monitor is intended to operate in an industrial or control room environment which uses some form of power isolation from the public lowndashvoltage mains Some monitor configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union Obtain permission from the local power authority before you connect any monitor configuration that draws more than 75 W of AC power directly from the public mainsTo comply with EN 55024 the Ethernet port LAN cable must be used only indoors All other IO cables must be less than 3 m (984 ft) and used only indoors

12 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 13: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Install the Monitor Chapter 2

Installation Guidelines Follow these guidelines to make sure your monitor provides service with excellent reliability

bull The installation site must have sufficient power

bull In dry environments static charges can build up easily Proper grounding of the monitor helps to reduce static discharges which can cause shock and damage electronic components

bull The ambient air temperature must not exceed the maximum operating temperature of 0hellip50 degC (32hellip122 degF)

bull The humidity of the ambient air must not exceed 90 40 degC (104 degF) noncondensing

bull The monitor cover must always remain in place during operation The cover provides protection against high voltages inside the monitor and inhibits radio frequency emissions that can interfere with other equipment

bull You can only mount and operate VersaView monitors in a horizontal orientation (with the interfaces at the bottom) and the vertical (upright) position Vertical orientation (with the interfaces to the left or to the right) is only possible when supported by the operating system that is used

ATTENTION For applications with an AC power source the AC-to-DC power adapter (ordered separately) must be plugged into a grounded outlet to maintain an electrically safe installation

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

IMPORTANT The monitor can operate at a range of extremes However the life span of any electronic device is shortened if you continuously operate the monitor at its highest rated temperature which includes the touch screen and LCD panel

Horizontal OrientationVertical Position

In both views interfaces are at the bottom of the monitor

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 13

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 14: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 2 Install the Monitor

Enclosure Guidelinesbull The enclosure must allow sufficient space around air inlets and outlets to

provide the circulation necessary for cooling See Mounting Clearance Requirements for further information Never allow air passages to become obstructed

bull Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circulating

Consider a user-supplied fan heat exchanger or air conditioner for heat generated by other devices in the enclosure See Installation Guidelines on page 13 for the acceptable temperature ranges for these monitors

Mounting Clearance Requirements

To help prevent overheating and to provide access to the monitor IO ports for cable connections leave at least 5 cm (2 in) of free space around the monitor

Do not obstruct the air intake exhaust openings or cooling fins of the monitor cover

IMPORTANT Monitors generate heat Therefore do not operate the monitor in an enclosure with the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure

Air Flow Direction

14 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 15: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Install the Monitor Chapter 2

Monitor Dimensions Review the monitor dimensions to make sure that you allow adequate clearance on the sides and rear of the monitor for ventilation and cable connections

Figure 2 shows the monitor dimensions in mm (in)

Figure 2 - VersaView 5100 Industrial Monitor Dimensions

Required Tools These tools are required for monitor installation bull 2 cross-head screwdriverbull Panel cutout tools (for wall and panel mounting)bull 2 mm Allen wrench (for mounting clips)bull Anti-static wriststrap

315 (1240)266 (105)291 (1146)

340 (1339)55 (022)

12 (0

47)

235 (

925)

605 (238)

260 (

1024

)

197 (

776)

AB

CE

D

F

G

H

I

J

K

Monitor Model

Dimensions mm (in)

A B C D E F G H I J K

6200M-12WBN

240(945)

310(122)

129(508)

248(976)

266(1047)

328(1291)

605(238)

27(106)

56(022)

15(06)

661(26)

6200M-15WBN 396(156)

280(1102)

298(1173)

414(163)

6200M-19WBN 462(1819)

319(1256)

337(1327)

480(189)

6200M-22WBN 527(2074)

355(1397)

373(1469)

545(2146)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 15

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB ltFEFF005500740069006c0069007a006500200065007300730061007300200063006f006e00660069006700750072006100e700f50065007300200064006500200066006f0072006d00610020006100200063007200690061007200200064006f00630075006d0065006e0074006f0073002000410064006f0062006500200050004400460020007000610072006100200069006d0070007200650073007300f5006500730020006400650020007100750061006c0069006400610064006500200065006d00200069006d00700072006500730073006f0072006100730020006400650073006b0074006f00700020006500200064006900730070006f00730069007400690076006f0073002000640065002000700072006f00760061002e0020004f007300200064006f00630075006d0065006e0074006f00730020005000440046002000630072006900610064006f007300200070006f00640065006d0020007300650072002000610062006500720074006f007300200063006f006d0020006f0020004100630072006f006200610074002000650020006f002000410064006f00620065002000520065006100640065007200200035002e0030002000650020007600650072007300f50065007300200070006f00730074006500720069006f007200650073002egt SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 16: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 2 Install the Monitor

Install the Monitor The monitors support panel mounting

Panel Mounting Guidelines

Observe these guidelines when installing a monitor in a panel

bull Remove all electrical power from the panel before you make the cutoutbull Confirm that there is adequate space behind the panel For specific

information refer to Mounting Clearance Requirements on page 14bull Cut supporting panels to specifications before installation Take

precautions so metal cuttings do not enter components already installed in panel

The supplied mounting hardware accommodates panel thickness between 15hellip6 mm (006hellip024 in)

bull Make sure the area around the panel cutout is clearbull The only acceptable mounting position is in the horizontal position

with the IO ports at the bottom For further information see the last bullet point in Installation Guidelines on page 13

Panel Cutout Dimensions

The VersaView 5000 Cutout Template publication 6200-DS001 is shipped with all VersaView 5100 industrial monitors

The monitors must be mounted to meet these panel cutout dimensions

ATTENTION Failure to follow these guidelines can result in personal injury or damage to the panel components

Display Size (in) Cutout Dimensions (H x W) approx

121 250 x 312 mm (984 x 1228 in)

156 282 x 398 mm (111 x 1567 in)

185 321 x 464 mm (1264 x 1827 in)

215 357 x 529 mm (1406 x 2083 in)

16 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 17: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Install the Monitor Chapter 2

Mount the Monitor in a Panel

Mounting clips secure the monitor to the panel The number of clips varies by model

Follow these steps to mount the monitor in a panel

1 Remove power from the panel

2 Verify that the panel surface around the area to be cut is clean and free of be debris

3 Cut an opening in the panel by using the appropriate panel cutout dimensions found in Panel Cutout Dimensions on page 16

4 Attach cables to the monitor before installation if rear access to the monitor is limited after installation

For where to attach cables see Connect Peripherals on page 20

5 Make sure the sealing gasket is properly positioned on the monitor

6 Place the monitor in the panel cutout

7 Slide the mounting clips into the holes on the top bottom and sides of the monitor

8 Hand-tighten the mounting clips around the bezel by following the tighten sequence in Figure 3 on page 18

9 Repeat this process at least three times until the clips are hand-tight and the gasket is compressed uniformly against the panel

10 With a 2 mm Allen wrench tighten the mounting clips to a torque of 04 Nbullm (35 lbbullin) by following the torque sequence in Figure 3 on page 18 Do not overtighten

Display Size (in) Clips (qty) Cat No Description

121 8 6200V-MCLPS4 Replacement mounting clips (14)

156 12

185 14

215

ATTENTION Take precautions so metal fragments do not enter components already installed in the panel to avoid personal injury or damage to the panel components

IMPORTANT The gasket provided with the monitor forms a compression-type seal Therefore do not use sealing compounds

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 17

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 18: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 2 Install the Monitor

11 Repeat this process at least three times until the clips are properly torqued to 07 Nbullm (62 lbbullin) Verify that the gasket is compressed uniformly against the panel

Figure 3 - Tightening and Torquing Sequence for Mounting Clips

ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and to prevent product damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation

4

3

6

1 8

27

121 in Monitor Models

185 in and 215 in Monitor Models

8

3

4

7

10 1 5

11 6 2

13

8

7

14

3 4

10 1 5

11 6 2 9

12

12

9

156 in Monitor Models

5

IO PortsIO Ports

IO Ports

18 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 19: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Install the Monitor Chapter 2

VESA Mount a Monitor

You can use an optional benchtabletop adapter to mount VersaView monitors on a bench or tabletop

Observe these guidelines when you install a VersaView monitor on a mounting arm

bull The mounting surface and the mounting arm must be strong enough to support the monitor and the mounting hardware

bull The interface between the mounting arm and the monitor must meet VESA FPMPMI 100 mm (394 in) standards

bull The mounting location must provide adequate clearance to position and move the adjustable unit and to route cables

Follow these steps to mount the VESA monitor to a bench or tabletop

1 Mount the arm to the bench or tabletop by using screws bolts or clamps so the monitor cannot tip

2 Align the VESA mounting holes in the back of the monitor with the holes in the arm bracket

The illustration shows the mounting holes for VESA 100 mm interface pad

3 Insert the four supplied VESA mounting screws through the arm bracket and into the monitor

4 Tighten the screws to secure the monitor to the arm

IMPORTANT If you choose to VESA mount a monitor its IP rating is reduced from IP66 to IP20

Install Arm Install Monitor to Arm

VESA Mounting Holes (4)

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 19

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 20: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 2 Install the Monitor

Connect Peripherals See Hardware Features on page 10 for what ports are available to connect peripherals Use the table below for accessories to connect peripherals to VersaView monitors

Connect Power All VersaView 5100 monitors are factory shipped to be connected to a 24V DC power source

For applications with AC power sources an AC-to-DC power adapter (cat no 6200V-MPS4) can be ordered separately

Operate the monitor in an industrial or control room environment which uses some form of power isolation from the public low-voltage mains

IMPORTANT For optimal performance use only Rockwell Automation-approved active DisplayPort adaptersbull For the DisplayPort you need a DisplayPort cable or DisplayPort adapterbull For VGA you need 6189V-DVIVGA adapter and a VGA cablebull For DVI you need a DVI cablebull For the touch screen you need the USB Type A to USB Type B touch

screen cable

Cat No Description

6189V-DVIVGA DVI-I to VGA adapter

6200V-DPVGA2 DisplayPort to VGA active adapter

6200V-DPDVI2 DisplayPort to DVI-D active adapter

6200V-DPCBL2M DisplayPort to DisplayPort cable two meters (65 ft) long

6200V-DVICBL2M DVI-D to DVI-D cable two meters (65 ft) long

6200V-VGACBL2M VGA to VGA cable two meters (65 ft) long

6200V-USBCBL2M USB touch screen cable two meters (65 ft) long

6200V-MPS4 AC-to-DC power adapter

6200V-DCCONN DC power mating connector housing

ATTENTION Supply the monitor circuit with its own disconnect Use an uninterruptible power source (UPS) to help protect against unexpected power failure or power surges

20 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP 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 FRA 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 ITA ltFEFF005500740069006c0069007a007a006100720065002000710075006500730074006500200069006d0070006f007300740061007a0069006f006e00690020007000650072002000630072006500610072006500200064006f00630075006d0065006e00740069002000410064006f006200650020005000440046002000700065007200200075006e00610020007300740061006d007000610020006400690020007100750061006c0069007400e00020007300750020007300740061006d00700061006e0074006900200065002000700072006f006f0066006500720020006400650073006b0074006f0070002e0020004900200064006f00630075006d0065006e007400690020005000440046002000630072006500610074006900200070006f00730073006f006e006f0020006500730073006500720065002000610070006500720074006900200063006f006e0020004100630072006f00620061007400200065002000410064006f00620065002000520065006100640065007200200035002e003000200065002000760065007200730069006f006e006900200073007500630063006500730073006900760065002egt JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 21: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Install the Monitor Chapter 2

Connect AC Power

The AC-to-DC power adapter available from Rockwell Automation (cat no 6200V-MPS4) is a grounded IEC 60320 3-prong power cord with a power supply input that accepts 100hellip240V AC and is autoranging

Follow these steps to connect the monitor to an AC power source

1 Connect the AC-to-DC power adapter to the DC power input on the monitor See Hardware Features on page 10 for the DC power input location

2 Connect the power cord of the AC-to-DC power adapter to an AC power source

3 Apply 100hellip240V AC power to the monitor

Connect DC Power

DC power models support operation from a SELV(1) power source The DC common (DC-) can be connected together to the functional ground screw to support some SELV cases where grounding at the monitor is required by the end user

The power supply is internally protected against reverse polarity

SHOCK HAZARD Connect the power cord to an AC power source with an earth ground Failure to follow this warning can result in electrical shock

(1) Where safety extra low voltage (SELV) is as defined in IEC 61010-2-201

ATTENTION Use a SELV isolated and ungrounded power supply as input power to the monitor This power source provides protection so that under normal and single fault conditions the voltage between the conductors and Functional EarthProtective Earth does not exceed a safe value

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 21

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP 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 FRA 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 ITA ltFEFF005500740069006c0069007a007a006100720065002000710075006500730074006500200069006d0070006f007300740061007a0069006f006e00690020007000650072002000630072006500610072006500200064006f00630075006d0065006e00740069002000410064006f006200650020005000440046002000700065007200200075006e00610020007300740061006d007000610020006400690020007100750061006c0069007400e00020007300750020007300740061006d00700061006e0074006900200065002000700072006f006f0066006500720020006400650073006b0074006f0070002e0020004900200064006f00630075006d0065006e007400690020005000440046002000630072006500610074006900200070006f00730073006f006e006f0020006500730073006500720065002000610070006500720074006900200063006f006e0020004100630072006f00620061007400200065002000410064006f00620065002000520065006100640065007200200035002e003000200065002000760065007200730069006f006e006900200073007500630063006500730073006900760065002egt JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR ltFEFF004200720075006b00200064006900730073006500200069006e006e007300740069006c006c0069006e00670065006e0065002000740069006c002000e50020006f0070007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740065007200200066006f00720020007500740073006b00720069006600740020006100760020006800f800790020006b00760061006c00690074006500740020007000e500200062006f007200640073006b0072006900760065007200200065006c006c00650072002000700072006f006f006600650072002e0020005000440046002d0064006f006b0075006d0065006e00740065006e00650020006b0061006e002000e50070006e00650073002000690020004100630072006f00620061007400200065006c006c00650072002000410064006f00620065002000520065006100640065007200200035002e003000200065006c006c00650072002000730065006e006500720065002egt PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 22: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 2 Install the Monitor

Follow these steps to connect the monitor to a DC power source

1 Turn off the main power switch or breaker

2 Verify that the DC power wires meet these requirementsbull Material Stranded copperbull Wire gauge 0326hellip331 mm (22hellip12 AWG)

3 Insert each DC power wire into the correct terminal on the DC terminal block

Refer to the DC power input connector on the bottom of the monitor for which wires to connect to the DC terminal block

4 Connect the DC terminal block to the DC power input

5 Connect the monitor to earth ground by using a 15 mm2 (16 AWG) or larger external wire

Use a ground wire with an insulation color that is approved by local inspection authority

6 Apply 24V DC power to the monitor

TIP The following steps are to wire and attach the DC terminal block that is supplied with the monitorThe optional DC connector shown at right cat no 6200V-DCCONN can be used instead of the DC terminal block

DC power input connector on the bottom of the monitorUse the symbols for correct DC power wiring

DC terminal block that is supplied with monitor DC terminal block installed in DC power input connector (shown without wires connected)

Ground Stud

TIP VersaView 5100 monitors have a ground stud on the bottom of the monitor Use this ground stud to connect the monitor to earth ground

22 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 23: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 3

Configure the Display

Set the Monitor Type If you are using a Windows plug and play operating system your computer automatically detects the monitor type during the start-up process

If your video card does not support plug and play you must set the monitor type manually (for example the screen image may be too small too large or distorted) Some older video cards must also be enabled to detect the monitor type

Check and Change the Display Resolution

Flat panel monitors are fixed-resolution devices The image looks best when the monitors are operated at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible while running in non-native modes

Native resolutions differ depending on the monitor For native resolutions see Table 1 on page 9

If you switch the resolution of your monitor from its native resolution the display may look slightly distorted due to the replication techniques used to fill the full screen with an image

To check or change the display resolution access the Display settings in the Control Panel on your computer

Topic Page

Set the Monitor Type 23

Check and Change the Display Resolution 23

Touch Screen Precautions 24

Adjust the Display Brightness 25

IMPORTANT The monitors use a (digital) flat panel display When they are driven by a computerrsquos analog VGA interface they are connected as an analog device Therefore some setup screens can indicate that the monitor is operating as an analog device rather than a digital or flat-panel device

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 23

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 24: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 3 Configure the Display

Touch Screen Precautions

Touch Screen Driver Software

The Microsoft touch screen driver is typically loaded on a computer as part of the operating system which recognizes the touch screen

For optimized functionality with FactoryTalkreg View software an alternate touch screen driver is recommended which is available for download at the Rockwell Automationreg Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

WARNING If the LCD screen darkens or if the backlight is not functioning properly the screen may be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstancesThe design of the system must take into account the possibility of the LCD screen or LCD touch screen losing functionality and unable to be used to maintain or change control of the system The touch screen shall not be the single point of control of critical functions and is not intended to replace an E-stopDesign of the system should follow all applicable code and good engineering practice Factors to consider include the followingbull The possibility of an unreadable LCD screenbull The possibility of an inoperable touch screenbull Unexpected communication errors or delaysbull Operator error in the control of the systembull Proper use of E-stops and other safety practicesThe user shall provide means to achieve a safe state during anomalies and to help ensure the system has adequate redundancy for critical functionsFailure to follow these instructions can result in death serious injury or equipment damage

24 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA ltFEFF005500740069006c006900730065007a00200063006500730020006f007000740069006f006e00730020006100660069006e00200064006500200063007200e900650072002000640065007300200064006f00630075006d0065006e00740073002000410064006f00620065002000500044004600200070006f007500720020006400650073002000e90070007200650075007600650073002000650074002000640065007300200069006d007000720065007300730069006f006e00730020006400650020006800610075007400650020007100750061006c0069007400e90020007300750072002000640065007300200069006d007000720069006d0061006e0074006500730020006400650020006200750072006500610075002e0020004c0065007300200064006f00630075006d0065006e00740073002000500044004600200063007200e900e90073002000700065007500760065006e0074002000ea0074007200650020006f007500760065007200740073002000640061006e00730020004100630072006f006200610074002c002000610069006e00730069002000710075002700410064006f00620065002000520065006100640065007200200035002e0030002000650074002000760065007200730069006f006e007300200075006c007400e90072006900650075007200650073002egt ITA ltFEFF005500740069006c0069007a007a006100720065002000710075006500730074006500200069006d0070006f007300740061007a0069006f006e00690020007000650072002000630072006500610072006500200064006f00630075006d0065006e00740069002000410064006f006200650020005000440046002000700065007200200075006e00610020007300740061006d007000610020006400690020007100750061006c0069007400e00020007300750020007300740061006d00700061006e0074006900200065002000700072006f006f0066006500720020006400650073006b0074006f0070002e0020004900200064006f00630075006d0065006e007400690020005000440046002000630072006500610074006900200070006f00730073006f006e006f0020006500730073006500720065002000610070006500720074006900200063006f006e0020004100630072006f00620061007400200065002000410064006f00620065002000520065006100640065007200200035002e003000200065002000760065007200730069006f006e006900200073007500630063006500730073006900760065002egt JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 25: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Configure the Display Chapter 3

Adjust the Display Brightness You can adjust the brightness of the display through a utility that is available for download at the Rockwell Automation Product Compatibility and Download Center (PCDC) at httpscompatibilityrockwellautomationcomPageshomeaspx

IMPORTANT If you adjust the monitor brightness higher than the factory default setting it can reduce the life of the LCD displayIf you adjust the monitor brightness too low it can turn off the displayThe default setting may vary by display size and LCD model used

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 25

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO ltFEFF004b00e40079007400e40020006e00e40069007400e4002000610073006500740075006b007300690061002c0020006b0075006e0020006c0075006f0074002000410064006f0062006500200050004400460020002d0064006f006b0075006d0065006e007400740065006a00610020006c0061006100640075006b006100730074006100200074007900f6007000f60079007400e400740075006c006f0073007400750073007400610020006a00610020007600650064006f007300740075007300740061002000760061007200740065006e002e00200020004c0075006f0064007500740020005000440046002d0064006f006b0075006d0065006e00740069007400200076006f0069006400610061006e0020006100760061007400610020004100630072006f0062006100740069006c006c00610020006a0061002000410064006f00620065002000520065006100640065007200200035002e0030003a006c006c00610020006a006100200075007500640065006d006d0069006c006c0061002egt SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 26: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 3 Configure the Display

Notes

26 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN ltFEFF9ad854c18cea51fa529b7528002000410064006f0062006500200050004400460020658766f8306e4f5c6210306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e3059300230c730b930af30c830c330d730d730ea30f330bf3067306e53705237307e305f306f30d730eb30fc30d57528306b9069305730663044307e305930023053306e8a2d5b9a30674f5c62103055308c305f0020005000440046002030d530a130a430eb306f3001004100630072006f0062006100740020304a30883073002000410064006f00620065002000520065006100640065007200200035002e003000204ee5964d3067958b304f30533068304c3067304d307e30593002gt KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE ltFEFF0041006e007600e4006e00640020006400650020006800e4007200200069006e0073007400e4006c006c006e0069006e006700610072006e00610020006f006d002000640075002000760069006c006c00200073006b006100700061002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740020006600f600720020006b00760061006c00690074006500740073007500740073006b0072006900660074006500720020007000e5002000760061006e006c00690067006100200073006b0072006900760061007200650020006f006300680020006600f600720020006b006f007200720065006b007400750072002e002000200053006b006100700061006400650020005000440046002d0064006f006b0075006d0065006e00740020006b0061006e002000f600700070006e00610073002000690020004100630072006f0062006100740020006f00630068002000410064006f00620065002000520065006100640065007200200035002e00300020006f00630068002000730065006e006100720065002egt ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 27: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 4

Clean the Monitor

Clean the Monitor To maintain your monitor it is important to clean the display cooling fins and vent holes and to remove grease or paint

Clean the Integrated Display

Perform the following steps to clean the display

1 Disconnect power from the monitor at the power source

2 Clean the display with a mild soap with a clean sponge or a soft cloth

3 Dry the display with a chamois or moist cellulose sponge to avoid water spots

Topic Page

Clean the Monitor 27

IMPORTANT VersaViewreg 5100 monitors resist the following chemicalsbull Alcohol (methyl ethyl or isopropyl)bull Ammonia (10 dilute solution)bull Automatic transmission fluidbull Bleachbull Commercial glass cleanersbull Diesel fuelbull Gasoline (unleaded)bull Oil (hydraulic or motor)bull Silicone-based lubricant

ATTENTION Since the display is a touch screen it is possible for screen objects to activate during equipment washdowns if the monitor is turned on

ATTENTION Use of abrasive cleansers solvents and high-pressure washes can damage the display window Do not scrub or use brushes

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 27

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA ltFEFF005500740069006c0069007a007a006100720065002000710075006500730074006500200069006d0070006f007300740061007a0069006f006e00690020007000650072002000630072006500610072006500200064006f00630075006d0065006e00740069002000410064006f006200650020005000440046002000700065007200200075006e00610020007300740061006d007000610020006400690020007100750061006c0069007400e00020007300750020007300740061006d00700061006e0074006900200065002000700072006f006f0066006500720020006400650073006b0074006f0070002e0020004900200064006f00630075006d0065006e007400690020005000440046002000630072006500610074006900200070006f00730073006f006e006f0020006500730073006500720065002000610070006500720074006900200063006f006e0020004100630072006f00620061007400200065002000410064006f00620065002000520065006100640065007200200035002e003000200065002000760065007200730069006f006e006900200073007500630063006500730073006900760065002egt JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR ltFEFF004200720075006b00200064006900730073006500200069006e006e007300740069006c006c0069006e00670065006e0065002000740069006c002000e50020006f0070007000720065007400740065002000410064006f006200650020005000440046002d0064006f006b0075006d0065006e00740065007200200066006f00720020007500740073006b00720069006600740020006100760020006800f800790020006b00760061006c00690074006500740020007000e500200062006f007200640073006b0072006900760065007200200065006c006c00650072002000700072006f006f006600650072002e0020005000440046002d0064006f006b0075006d0065006e00740065006e00650020006b0061006e002000e50070006e00650073002000690020004100630072006f00620061007400200065006c006c00650072002000410064006f00620065002000520065006100640065007200200035002e003000200065006c006c00650072002000730065006e006500720065002egt PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 28: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 4 Clean the Monitor

Clean the Air Openings and Cooling Fins

Perform the following steps to clean all VersaView 5100 industrial monitors

1 Disconnect power from the monitor at the power source

2 Disconnect all peripheral devices from the monitor

3 Vacuum dust and debris from the vent holes on the sides of the monitor and from the cooling fins on the chassis

Remove stubborn dirt on the cooling fins with a mild detergent and soft cloth

Remove Paint and Grease from Bezel

Perform the following steps to remove paint and grease from the bezel of monitors properly mounted in IP66 enclosures

1 Remove paint splashes and grease by rubbing lightly with isopropyl alcohol

2 Use a mild soap or detergent solution to remove residue

3 Rinse with clean water

ATTENTION Make sure the isopropyl alcohol does not come in contact with the equipment labels Alcohol can cause the label printing to smear

28 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 29: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 5

Troubleshoot the Monitor

Troubleshooting The troubleshooting table lists typical problems you may encounter when you use your VersaViewreg monitor It contains symptoms and possible actions to correct a problem

Topic Page

Troubleshooting 29

Ship or Transport the Monitor 30

Dispose of the Monitor 30

Table 2 - Troubleshooting

Symptom Action

No signal message Check the video cable connection between the computer and monitor

Screen is blank The video mode may be out of range Change to the native resolution

Disable the screen saver on the computer

Verify that the power cord is connected

Test the outlet by plugging in a properly functioning device

Replace the suspected faulty cable or power cord

Have the monitor serviced

Out of range message Check the maximum resolution and the frequency on the video port of your computer

Picture is scrambled The video mode may be out of range Change to the native resolution

Check the video cable connection between the computer and monitor

Check the maximum resolution and the frequency of the video port of your computer

Picture is not clear Verify the screen refresh frequency rate1 Click the Control PanelgtDisplaysgtSettings2 Select the Monitors tab and then click Advanced3 Try refresh frequencies of 60 Hz 70 Hz or 75 Hz Note Settings higher than 75 Hz do not display

Check the video cable connection between the computer and monitor

Perform a monitor power reset

Minimize unnecessary accessories such as video extension cables

Perform the automatic video adjustment function

Image is not stable The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Screen jitter or noisy video The video mode may be out of range Change to the native resolution

Check for proper video cable installation Replace the suspected faulty cable

Reroute the cables or replace suspected faulty cables

Check the host computer and monitor grounding

Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 29

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO ltFEFF004b00e40079007400e40020006e00e40069007400e4002000610073006500740075006b007300690061002c0020006b0075006e0020006c0075006f0074002000410064006f0062006500200050004400460020002d0064006f006b0075006d0065006e007400740065006a00610020006c0061006100640075006b006100730074006100200074007900f6007000f60079007400e400740075006c006f0073007400750073007400610020006a00610020007600650064006f007300740075007300740061002000760061007200740065006e002e00200020004c0075006f0064007500740020005000440046002d0064006f006b0075006d0065006e00740069007400200076006f0069006400610061006e0020006100760061007400610020004100630072006f0062006100740069006c006c00610020006a0061002000410064006f00620065002000520065006100640065007200200035002e0030003a006c006c00610020006a006100200075007500640065006d006d0069006c006c0061002egt SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 30: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Chapter 5 Troubleshoot the Monitor

Ship or Transport the Monitor

If you must ship the monitor via common carrier or otherwise transport it to another location for service or any other reason you must first uninstall the monitor and place it in its original packing material

Dispose of the Monitor

You cannot dispose of monitor equipment like other waste material Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to safely dispose of monitor equipment

ATTENTION Do not ship or transport the monitor when it is installed in a machine panel or rack To avoid damage to the monitor you must uninstall the monitor and place it in its original packing material before you ship it Rockwell Automation is not responsible for damage to a monitor that is shipped or transported while installed in a machine panel or rack

At the end of its life collect the monitor separately from any unsorted municipal waste

30 Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU 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 ESP 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 FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 31: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Publication 6200M-UM001A-EN-P - December 2017 PN-XXXXXX-XXSupersedes Publication 6186M-UM002B-EN-P - March 2012 Copyright copy 2017 Rockwell Automation Inc All rights reserved Printed in the USA

Rockwell Automation SupportUse the following resources to access support information

Documentation FeedbackYour comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at httpliteraturerockwellautomationcomidcgroupsliteraturedocumentsdura-du002_-en-epdf

Technical Support Center Knowledgebase Articles How-to Videos FAQs Chat User Forums and Product Notification Updates httpsrockwellautomationcusthelpcom

Local Technical Support Phone Numbers Locate the phone number for your country httpwwwrockwellautomationcomglobalsupportget-support-nowpage

Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer httpwwwrockwellautomationcomglobalsupportdirect-dialpage

Literature Library Installation Instructions Manuals Brochures and Technical Data httpwwwrockwellautomationcomgloballiterature-libraryoverviewpage

Product Compatibility and Download Center (PCDC)

Get help determining how products interact check features and capabilities and find associated firmware httpwwwrockwellautomationcomglobalsupportpcdcpage

Rockwell Otomasyon Ticaret AŞ Kar Plaza İş Merkezi E Blok Kat6 34752 İccedilerenkoumly İstanbul Tel +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at httpwwwrockwellautomationcomrockwellautomationabout-ussustainability-ethicsproduct-environmental-compliancepage

Allen-Bradley FactoryTalk Rockwell Automation Rockwell Software and VersaView are trademarks of Rockwell Automation Inc

Trademarks not belonging to Rockwell Automation are property of their respective companies

  • VersaView 5100 Industrial Monitors User Manual
  • Important User Information
  • Table of Contents
  • Preface
    • Abbreviations
    • Additional Resources
      • 1- Monitor Features
        • Monitor Options
        • Hardware Features
          • 2 - Install the Monitor
            • Before You Begin
            • Parts List
            • Installation Precautions
              • Environment and Enclosure Information
              • European Union Directive Compliance
                • Installation Guidelines
                  • Enclosure Guidelines
                    • Mounting Clearance Requirements
                    • Monitor Dimensions
                    • Required Tools
                    • Install the Monitor
                      • Panel Mounting Guidelines
                      • Panel Cutout Dimensions
                      • Mount the Monitor in a Panel
                      • VESA Mount a Monitor
                        • Connect Peripherals
                        • Connect Power
                          • Connect AC Power
                          • Connect DC Power
                              • 3 - Configure the Display
                                • Set the Monitor Type
                                • Check and Change the Display Resolution
                                • Touch Screen Precautions
                                  • Touch Screen Driver Software
                                    • Adjust the Display Brightness
                                      • 4 - Clean the Monitor
                                        • Clean the Monitor
                                          • Clean the Integrated Display
                                          • Clean the Air Openings and Cooling Fins
                                          • Remove Paint and Grease from Bezel
                                              • 5 - Troubleshoot the Monitor
                                                • Troubleshooting
                                                • Ship or Transport the Monitor
                                                • Dispose of the Monitor
                                                  • Back Page
                                                    • Rockwell Automation Support
                                                    • Documentation Feedback
                                                    • Contact Information
                                                        • ltlt ASCII85EncodePages false AllowTransparency false AutoPositionEPSFiles true AutoRotatePages All Binding Left CalGrayProfile (Dot Gain 20) CalRGBProfile (sRGB IEC61966-21) CalCMYKProfile (US Web Coated 050SWOP051 v2) sRGBProfile (sRGB IEC61966-21) CannotEmbedFontPolicy Error CompatibilityLevel 16 CompressObjects Tags CompressPages true ConvertImagesToIndexed true PassThroughJPEGImages true CreateJobTicket false DefaultRenderingIntent Default DetectBlends true DetectCurves 00000 ColorConversionStrategy LeaveColorUnchanged DoThumbnails false EmbedAllFonts true EmbedOpenType false ParseICCProfilesInComments true EmbedJobOptions true DSCReportingLevel 0 EmitDSCWarnings false EndPage -1 ImageMemory 1048576 LockDistillerParams true MaxSubsetPct 1 Optimize true OPM 1 ParseDSCComments false ParseDSCCommentsForDocInfo true PreserveCopyPage true PreserveDICMYKValues true PreserveEPSInfo true PreserveFlatness true PreserveHalftoneInfo false PreserveOPIComments false PreserveOverprintSettings true StartPage 1 SubsetFonts false TransferFunctionInfo Apply UCRandBGInfo Remove UsePrologue false ColorSettingsFile () AlwaysEmbed [ true ] NeverEmbed [ true ] AntiAliasColorImages false CropColorImages true ColorImageMinResolution 300 ColorImageMinResolutionPolicy OK DownsampleColorImages true ColorImageDownsampleType Average ColorImageResolution 300 ColorImageDepth -1 ColorImageMinDownsampleDepth 1 ColorImageDownsampleThreshold 200000 EncodeColorImages true ColorImageFilter DCTEncode AutoFilterColorImages false ColorImageAutoFilterStrategy JPEG ColorACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt ColorImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000ColorACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000ColorImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasGrayImages false CropGrayImages true GrayImageMinResolution 300 GrayImageMinResolutionPolicy OK DownsampleGrayImages true GrayImageDownsampleType Average GrayImageResolution 300 GrayImageDepth -1 GrayImageMinDownsampleDepth 2 GrayImageDownsampleThreshold 200000 EncodeGrayImages true GrayImageFilter DCTEncode AutoFilterGrayImages false GrayImageAutoFilterStrategy JPEG GrayACSImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt GrayImageDict ltlt QFactor 015 HSamples [1 1 1 1] VSamples [1 1 1 1] gtgt JPEG2000GrayACSImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt JPEG2000GrayImageDict ltlt TileWidth 256 TileHeight 256 Quality 30 gtgt AntiAliasMonoImages false CropMonoImages true MonoImageMinResolution 1200 MonoImageMinResolutionPolicy OK DownsampleMonoImages true MonoImageDownsampleType Average MonoImageResolution 1200 MonoImageDepth -1 MonoImageDownsampleThreshold 150000 EncodeMonoImages true MonoImageFilter CCITTFaxEncode MonoImageDict ltlt K -1 gtgt AllowPSXObjects false CheckCompliance [ None ] PDFX1aCheck false PDFX3Check false PDFXCompliantPDFOnly false PDFXNoTrimBoxError true PDFXTrimBoxToMediaBoxOffset [ 000000 000000 000000 000000 ] PDFXSetBleedBoxToMediaBox true PDFXBleedBoxToTrimBoxOffset [ 000000 000000 000000 000000 ] PDFXOutputIntentProfile (None) PDFXOutputConditionIdentifier () PDFXOutputCondition () PDFXRegistryName () PDFXTrapped False CreateJDFFile false Description ltlt CHS ltFEFF4f7f75288fd94e9b8bbe5b9a521b5efa7684002000500044004600206587686353ef901a8fc7684c976262535370673a548c002000700072006f006f00660065007200208fdb884c9ad88d2891cf62535370300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c676562535f00521b5efa768400200050004400460020658768633002gt CHT ltFEFF4f7f752890194e9b8a2d7f6e5efa7acb7684002000410064006f006200650020005000440046002065874ef653ef5728684c9762537088686a5f548c002000700072006f006f00660065007200204e0a73725f979ad854c18cea7684521753706548679c300260a853ef4ee54f7f75280020004100630072006f0062006100740020548c002000410064006f00620065002000520065006100640065007200200035002e003000204ee553ca66f49ad87248672c4f86958b555f5df25efa7acb76840020005000440046002065874ef63002gt DAN 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 DEU ltFEFF00560065007200770065006e00640065006e0020005300690065002000640069006500730065002000450069006e007300740065006c006c0075006e00670065006e0020007a0075006d002000450072007300740065006c006c0065006e00200076006f006e002000410064006f006200650020005000440046002d0044006f006b0075006d0065006e00740065006e002c00200076006f006e002000640065006e0065006e002000530069006500200068006f00630068007700650072007400690067006500200044007200750063006b006500200061007500660020004400650073006b0074006f0070002d0044007200750063006b00650072006e00200075006e0064002000500072006f006f0066002d00470065007200e400740065006e002000650072007a0065007500670065006e0020006d00f60063006800740065006e002e002000450072007300740065006c006c007400650020005000440046002d0044006f006b0075006d0065006e007400650020006b00f6006e006e0065006e0020006d006900740020004100630072006f00620061007400200075006e0064002000410064006f00620065002000520065006100640065007200200035002e00300020006f0064006500720020006800f600680065007200200067006500f600660066006e00650074002000770065007200640065006e002egt ESP ltFEFF005500740069006c0069006300650020006500730074006100200063006f006e0066006900670075007200610063006900f3006e0020007000610072006100200063007200650061007200200064006f00630075006d0065006e0074006f0073002000640065002000410064006f0062006500200050004400460020007000610072006100200063006f006e00730065006700750069007200200069006d0070007200650073006900f3006e002000640065002000630061006c006900640061006400200065006e00200069006d0070007200650073006f0072006100730020006400650020006500730063007200690074006f00720069006f00200079002000680065007200720061006d00690065006e00740061007300200064006500200063006f00720072006500630063006900f3006e002e002000530065002000700075006500640065006e00200061006200720069007200200064006f00630075006d0065006e0074006f00730020005000440046002000630072006500610064006f007300200063006f006e0020004100630072006f006200610074002c002000410064006f00620065002000520065006100640065007200200035002e003000200079002000760065007200730069006f006e0065007300200070006f00730074006500720069006f007200650073002egt FRA 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 ITA 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 JPN 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 KOR ltFEFFc7740020c124c815c7440020c0acc6a9d558c5ec0020b370c2a4d06cd0d10020d504b9b0d1300020bc0f0020ad50c815ae30c5d0c11c0020ace0d488c9c8b85c0020c778c1c4d560002000410064006f0062006500200050004400460020bb38c11cb97c0020c791c131d569b2c8b2e4002e0020c774b807ac8c0020c791c131b41c00200050004400460020bb38c11cb2940020004100630072006f0062006100740020bc0f002000410064006f00620065002000520065006100640065007200200035002e00300020c774c0c1c5d0c11c0020c5f40020c2180020c788c2b5b2c8b2e4002egt NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken voor kwaliteitsafdrukken op desktopprinters en proofers De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 50 en hoger) NOR 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 PTB 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 SUO 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 SVE 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 ENU (Use these settings to create Adobe PDF documents for quality printing on desktop printers and proofers Created PDF documents can be opened with Acrobat and Adobe Reader 50 and later) gtgt Namespace [ (Adobe) (Common) (10) ] OtherNamespaces [ ltlt AsReaderSpreads false CropImagesToFrames true ErrorControl WarnAndContinue FlattenerIgnoreSpreadOverrides false IncludeGuidesGrids false IncludeNonPrinting false IncludeSlug false Namespace [ (Adobe) (InDesign) (40) ] OmitPlacedBitmaps false OmitPlacedEPS false OmitPlacedPDF false SimulateOverprint Legacy gtgt ltlt AddBleedMarks false AddColorBars false AddCropMarks false AddPageInfo false AddRegMarks false ConvertColors NoConversion DestinationProfileName () DestinationProfileSelector NA Downsample16BitImages true FlattenerPreset ltlt PresetSelector MediumResolution gtgt FormElements false GenerateStructure true IncludeBookmarks false IncludeHyperlinks false IncludeInteractive false IncludeLayers false IncludeProfiles true MultimediaHandling UseObjectSettings Namespace [ (Adobe) (CreativeSuite) (20) ] PDFXOutputIntentProfileSelector NA PreserveEditing true UntaggedCMYKHandling LeaveUntagged UntaggedRGBHandling LeaveUntagged UseDocumentBleed false gtgt ]gtgt setdistillerparamsltlt HWResolution [2400 2400] PageSize [612000 792000]gtgt setpagedevice

                                                          Introduction_Category Types

                                                          Print Spec Sheet

                                                          MBD000B0209bin

                                                          MBD000B020Bbin

                                                          MBD000B020Cbin

                                                          MBD000B020Abin

                                                          MBD000B0205bin

                                                          MBD000B0207bin

                                                          MBD000B0208bin

                                                          MBD000B0206bin

                                                          MBD000B0203bin

                                                          MBD000B0204bin

                                                          JIT Printing Specifications RA-QR005J-EN-P - 6142013
                                                          Printing Specification YOUR DATA HERE Instructions NO
                                                          (required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
                                                          Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
                                                          Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
                                                          Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
                                                          Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
                                                          Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
                                                          (required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
                                                          Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
                                                          Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
                                                          (required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
                                                          (required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
                                                          Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
                                                          Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
                                                          BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
                                                          Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
                                                          Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
                                                          Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
                                                          Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
                                                          Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
                                                          (required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
                                                          (required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
                                                          Comments D2 Double Gate
                                                          FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
                                                          D4
                                                          D5
                                                          D6
                                                          D7
                                                          D8
                                                          D9
                                                          This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
                                                          Publication Type and Print Category
                                                          Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
                                                          AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
                                                          AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
                                                          AR NA NA ArticleEditorialByline NA NA Presale Internal
                                                          (press releases should not be checked into DocMan or printed)
                                                          AT B3 B4 D5 Application techniques 5 100 Presale External
                                                          BR A2 Primary A1 NA Brochures 5 100 Presale External
                                                          CA C2 Primary C1 NA Catalogue 1 50 Presale External
                                                          CG NA NA Catalogue Guide 1 50 Presale External
                                                          CL NA NA Collection 5 50 Presale External
                                                          CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
                                                          CP E-only E-only D5 Competitive Information 5 50 NA Confidential
                                                          DC E-only E-only Discount Schedules NA NA Presale Internal
                                                          DI A1 A3 NA Direct Mail 5 100 Presale Internal
                                                          DM NA NA Product Demo 5 50 Presale Internal
                                                          DS B3 D5 Dimensions Sheet 1 5 Post External
                                                          DU B3 D5 Document Update 1 5 Post External
                                                          GR B2 D6 Getting Results 1 5 Post External
                                                          IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
                                                          LM NA NA Launch Materials 5 50 Presale Internal
                                                          PC B3 D5 Packaging Contents
                                                          PL E-only primary B3 E-only Price List 5 50 Presale Internal
                                                          PM B2 D6 Programming Manual 1 5 Post External
                                                          PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
                                                          QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
                                                          QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
                                                          RM B2 D5 D6 Reference Manual 1 5 Post External
                                                          RN B3 D5 Release Notes 1 5 Post External
                                                          SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
                                                          SG B2 D5 D6 Selection Guide BW 5 50 Presale External
                                                          SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
                                                          SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
                                                          TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
                                                          TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
                                                          UM B2 Primary B4 D6 User Manual BW 1 5 Post External
                                                          WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
                                                          WP B3 Primary B5 D5 White Paper 5 50 Presale External
                                                          Minimum order quantities on all JIT items are based on the publication length
                                                          Publication length Minimum Order Quantity
                                                          77 or more pages 1 (no shrink wrap required)
                                                          33 to 76 pages 25
                                                          3 to 32 pages 50
                                                          1 or 2 pages 100
                                                          Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
                                                          A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
                                                          A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
                                                          A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
                                                          A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
                                                          A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
                                                          A8 4 color cover Category being deleted 50 matte sheet text self cover
                                                          2 color text
                                                          Selection Guide
                                                          A9 2 color 100gsm bond 50 matte sheet text self cover
                                                          Selection Guide
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Post Sale Technical Communication
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
                                                          2 color text 50 matte sheet text
                                                          B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B3 1 color 100gsm bond 50 matte sheet text self cover
                                                          B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
                                                          B5 2 color 100gsm bond 50 matte sheet text self cover
                                                          Catalogs
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
                                                          4 color text 45 Coated Sheet
                                                          C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
                                                          2 color text 32-33 Coated Sheet
                                                          JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
                                                          Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
                                                          D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
                                                          D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
                                                          D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
                                                          D4 1 color 160gsm tab 90 index
                                                          D5 1 color 80gsm bond 20 bond self cover
                                                          D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D7 2 color 160gsm tab 90 index
                                                          D8 2 color 80gsm bond 20 bond self cover
                                                          D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
                                                          D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
                                                          Gray shading indicates Obsolete Print Catagories
                                                          Just In Time (JIT) or Off Set (OS)
                                                          Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
                                                          Black amp White Printing
                                                          Color Printing
                                                          Color Printing
Page 32: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Introduction_Category Types

Print Spec Sheet

MBD000B0209bin

MBD000B020Bbin

MBD000B020Cbin

MBD000B020Abin

MBD000B0205bin

MBD000B0207bin

MBD000B0208bin

MBD000B0206bin

MBD000B0203bin

MBD000B0204bin

JIT Printing Specifications RA-QR005J-EN-P - 6142013
Printing Specification YOUR DATA HERE Instructions NO
(required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
(required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
(required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
(required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
(required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
(required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
Comments D2 Double Gate
FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
D4
D5
D6
D7
D8
D9
This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printingFind your publication type in the first section below Use the assigned Printing Category information to determine the standard print specifications for that document type The Printing Categories are defined below the Publication Type section Note there may be slightly different print specifications for the categories depending on the region (EMEA or Americas)For more information on Global Sales and Marketing Printing Standards see publication RA-CO004 in DocMan
Publication Type and Print Category
Publication Type Off Set Print Category Spec (See table below) JIT Spec (See table below) Description Order Min Order Max Life Cycle Usage Release Option
AD NA - Puttman NA Advertisement Reprint Colour NA NA Presale Internal
AP A3 D2 Application Solution or Customer Success Story 5 100 Presale External
AR NA NA ArticleEditorialByline NA NA Presale Internal
(press releases should not be checked into DocMan or printed)
AT B3 B4 D5 Application techniques 5 100 Presale External
BR A2 Primary A1 NA Brochures 5 100 Presale External
CA C2 Primary C1 NA Catalogue 1 50 Presale External
CG NA NA Catalogue Guide 1 50 Presale External
CL NA NA Collection 5 50 Presale External
CO A5 A6 A9 D5 Company Confidential Information NA NA NA Confidential
CP E-only E-only D5 Competitive Information 5 50 NA Confidential
DC E-only E-only Discount Schedules NA NA Presale Internal
DI A1 A3 NA Direct Mail 5 100 Presale Internal
DM NA NA Product Demo 5 50 Presale Internal
DS B3 D5 Dimensions Sheet 1 5 Post External
DU B3 D5 Document Update 1 5 Post External
GR B2 D6 Getting Results 1 5 Post External
IN B3 Primary B2 D5 D6 Installation instructions 1 5 Post External
LM NA NA Launch Materials 5 50 Presale Internal
PC B3 D5 Packaging Contents
PL E-only primary B3 E-only Price List 5 50 Presale Internal
PM B2 D6 Programming Manual 1 5 Post External
PP A3 D1 Profile (Single Product or Service) NOTE Application Solutions are to be assigned the AP pub type 5 100 Presale External
QR B2 primary B3 B5 D5 D6 Quick Reference 1 5 Post External
QS B2 primary B3 B5 D5 D6 Quick Start 1 5 Post External
RM B2 D5 D6 Reference Manual 1 5 Post External
RN B3 D5 Release Notes 1 5 Post External
SG B1 Primary B4 D5 D6 Selection Guide Colour 5 50 Presale External
SG B2 D5 D6 Selection Guide BW 5 50 Presale External
SP A1 A2 A3 A4 NA Sales Promotion NOTE Service profiles are to be assigned the PP pub type 5 100 Presale Internal
SR B2 B3 D5 D6 Specification Rating Sheet 5 100 Presale External
TD B2 Primary B3 B4 B5 D5 D6 Technical Data 5 50 Presale External
TG B2 B3 D6 Troubleshooting Guide 1 5 Post External
UM B2 Primary B4 D6 User Manual BW 1 5 Post External
WD B3 D5 Wiring Diagrams Dwgs 1 5 Post Internal
WP B3 Primary B5 D5 White Paper 5 50 Presale External
Minimum order quantities on all JIT items are based on the publication length
Publication length Minimum Order Quantity
77 or more pages 1 (no shrink wrap required)
33 to 76 pages 25
3 to 32 pages 50
1 or 2 pages 100
Pre-sale Marketing All paper in this category is White Brightness 90 or better Opacity 90 or better
Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
A1 4 color 170 gsm 2pp 100 gloss cover 100 gloss text
A2 4 color 170 gsm folded 4pp 100 gloss cover 80 gloss text
A3 4 color Cover 170 gsm with Body 120 gsm gt 4pp 80 gloss cover 80 gloss text
A4 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 gloss text
A5 2 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
A6 1 color 170gsm Silk ndash 120gsm Silk 80 gloss cover 80 matt sheet text
A7 4 color cover2 color textSelection Guide Category being deleted 10 Point Cover C2S50 matte sheet text
A8 4 color cover Category being deleted 50 matte sheet text self cover
2 color text
Selection Guide
A9 2 color 100gsm bond 50 matte sheet text self cover
Selection Guide
Gray shading indicates Obsolete Print Catagories
Post Sale Technical Communication
Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
B1 4 color cover 270gsm Gloss 100gsm bond 10 Point Cover C2S
2 color text 50 matte sheet text
B2 1 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
B3 1 color 100gsm bond 50 matte sheet text self cover
B4 2 color 160gsm Colortech amp 100gsm Bond 90 Cover50 matte sheet text
B5 2 color 100gsm bond 50 matte sheet text self cover
Catalogs
Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
C1 4 color cover 270gsm Gloss 90gsm silk 10 Point Cover C2S
4 color text 45 Coated Sheet
C2 4 color cover 270gsm Gloss 80gsm silk 10 Point Cover C2S
2 color text 32-33 Coated Sheet
JIT POD All paper in this category is White Brightness 82 or better Opacity 88 or better
Category Color Options AP EMEA Paper Requirements Canada LA US Paper Requirements
D1 4 color 170gsm white silk 80 gloss cover coated 2 sides
D2 4 color 120gsm white silk 80 gloss text coated 2 sides self cover
D3 4 color Cover 170gsm with Body 120gsm 80 gloss cover 80 gloss text coated 2 sides
D4 1 color 160gsm tab 90 index
D5 1 color 80gsm bond 20 bond self cover
D6 1 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
D7 2 color 160gsm tab 90 index
D8 2 color 80gsm bond 20 bond self cover
D9 2 color Cover 160gsm tab with Body 80gsm bond 90 index 20 bond
D10 Combination 4 color cover with 2 color body Cover 160gsm with Body 80gsm 90 index 20 bond
Gray shading indicates Obsolete Print Catagories
Just In Time (JIT) or Off Set (OS)
Use these guidelines to determine if your publication should be JIT (just in timeprint on demand) or if it would be more economical to print OS (offseton a press) OS print jobs require an RFQ (Request For Quote) in US If your job fits into the ldquoEitherrdquo category an RFQ is recommended but not required In the US RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category Guidelines differ for black amp white and color printing so be sure to check the correct tables
Black amp White Printing
Color Printing
Color Printing
Page 33: VersaView 5100 Industrial Monitors User Manual · Rockwell Automation Publication 6200M-UM001A-EN-P - December 2017 7 Preface This manual is a user guide for VersaView® 5100 industrial

Print Spec Sheet

MBD000B0209bin

MBD000B020Bbin

MBD000B020Cbin

MBD000B020Abin

MBD000B0205bin

MBD000B0207bin

MBD000B0208bin

MBD000B0206bin

MBD000B0203bin

MBD000B0204bin

JIT Printing Specifications RA-QR005J-EN-P - 6142013
Printing Specification YOUR DATA HERE Instructions NO
(required) Publication Number 6200M-UM001A-EN-P Sample 2030-SP001B-EN-P 11rdquo x 17rdquo LOOSE -Loose Leaf YES Pre-sale Marketing TOP
Use Legacy Number YES or NO 85rdquo x 11rdquo PERFECT - Perfect Bound A1 LEFT
Legacy Number if applicable Sample Legacy Number 0160-533 8375rdquo x 10875 SADDLE - Saddle Stitch A2 RIGHT CORNER
Publication Title VersaView 5100 Industrial Monitors User Manual Sample ElectroGuard Selling Brief80 character limit - must match DocMan Title 825rdquo x 11rdquo (RA product profile std) PLASTCOIL - Plastic Coil (Coil Bound) A4 BOTTOM SIDE
Used in Manufacturing NO YES or NO - If Yes must have Part No listed below 825rdquo x 10875rdquo STAPLED1 -1 position A3
Part Number If SAP Part Number be sure to enter PN- before the number 7385rdquo x 9rdquo (RSI Std) STAPLED1B - bottom 1 position A5
(required) Category D6 Select Print Category ABC or D from category list on Introduction_Category Types tab 6rdquo x 4rdquo STAPLED2 - 2 positions A6
Paper Stock Color White White is assumed For color options contact your vendor 55rdquo x 85rdquo (half-size) THERMAL - Thermal bound (Tape bound) A7
Ink Color Black One color assumes BLACK 4 color assume CMYK Indicate PMS number here 475rdquo x 775rdquo THERMALO - Thermal Bound (Tape bound - offline) A8
(required) Page Count ofPublication 32 Total page count including cover Enter PAGE count not SHEET count 475rdquo x 7rdquo (slightly smaller half-size) A9
(required) Finished Trim Size Width 11 x 17 This is sheet size before folding 425 x 550 Post Sale Technical Communication
Fold Half or V or Single Fold Review key below Leave blank if folded for saddle stitching 4rdquo x 6rdquo B1
Finished Fold Size 85 x 11 This is size after folding is completed 3rdquo x 5rdquo B2
BindingStitching STAPLED2 - 2 positions Review key below 9rdquo x 12rdquo (Folder) B3 None
Stitching Location SIDE Blank Corner or Side A4 (8 frac14rdquo x 11 frac34rdquo) (210 x 297 mm) B4 Half or V or Single Fold
Drill Hole (YesNo) NO All drilled publications use the 5-hole standard 516 inch-size hole and a minimum of frac14 inch from the inner page border A5 (583rdquo x 826rdquo) (148 x 210 mm) B5 C or Tri-Fold
Number of Tabs Needed 5 tab in stock at RR Donnelley 36rdquo x 24rdquo Poster Catalogs DbleParll
Number of Pages per Pad Average sheets of paper 25 50 75100 Max 24rdquo x 36rdquo Poster C1 Sample
Glue Location on Pad Glue location on pads 18rdquo x 24rdquo Poster C2 Short (must specify dimensions between folds in Comments)
(required) Business Group Marketing Commercial As entered in DocMan JITPOD Z or Accordian Fold
(required) Cost Center 19134-IA If your Business Unit is Marketing Commercial add the appropriate division name after 19134 using the chart on the right All other Business Units Enter only the number as in DocMan no description Example - 19021 19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US Marke D1 Microfold or French Fold - designate no of folds in Comments - intended for single sheet only to be put in box for manufacturing
Comments D2 Double Gate
FoldsHalf V Single C or TriDble ParllZ or Accordian Microfold or FrenchDouble Gate Short Fold Saddle-Stitch Items All page quantities must be divisible by 4Note Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location80 pgs max on 20 (text and cover)76 pgs max on 20 (text) and 24 (cover)72 pgs max on 24 (text and cover)Perfect Bound Items940 pgs max wcover (90 index unless indicated otherwise)70 pgs min for spine without words200 pgs min for spine with words Plastcoil Bound Items530 pgs max of 20 (if adding cover deduct equivalent number of pages to equal cover thickness) (90 index unless indicated otherwise)Tape Bound Items250 pgs max on 20 no cover240 pgs max wcover (90 index unless indicated otherwise) D3
D4
D5
D6
D7
D8
D9