PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and...

28
22 16 Allen-Bradley Electronic Operator Interface >> PANEL VIEW P LUS AND VERSA VIEW ® CE Operator Interface Terminals 22 Operator interface terminals designed to optimize system development, performance, and efficiency – featuring modular components, multiple communication options, advanced graphic features, and reusable development tools Optimizing system design and development PanelView Plus and VersaView CE are ideal for applications that need to display information graphically and log data so operators can quickly understand the status of their equipment. On the plant floor, this means information delivery for optimal system efficiency. Part of the ViewAnyWare strategy, PanelView Plus and VersaView CE terminals are configured with RSView Studio and provide RSView Machine Edition functionality, enabling the scalability of applications on a variety of platforms: operator interfaces, standalone Windows systems, and distributed servers. BENEFITS • Six display sizes in keypad, touch screen, and keypad/touch screen combination options • No hard drive, no fans, and no moving parts deliver superior ruggedness • Modular design with separate display, logic, and communication modules • Immediate startup with RSView Machine Edition pre-loaded and activated • Easy to maintain through field-replaceable bezels and backlights • Unit level immediate exchange for quick and easy replacement • High-bright 12" touch screen display (over 1000 nits) provides an ideal solution for outdoor environments • Windows CE operating system No registration required Shorter startup times Instant power shutdown 16 Allen-Bradley Electronic Operator Interface >> PanelView Plus and VersaView CE

Transcript of PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and...

Page 1: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

2216

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

PANELVIEW™ PLUS AND

VERSAVIEW® CEOperator Interface Terminals

22

Operator interface terminals designed to optimize systemdevelopment, performance, and efficiency – featuring modular components, multiple communication options,advanced graphic features, and reusable development tools

Optimizing system design and development

PanelView Plus and VersaView CE are ideal for applications that need to display information graphically and log data sooperators can quickly understand the status of their equipment.On the plant floor, this means information delivery for optimalsystem efficiency.

Part of the ViewAnyWare strategy, PanelView Plus andVersaView CE terminals are configured with RSView Studio and provide RSView Machine Edition functionality, enabling the scalability of applications on a variety of platforms: operator interfaces, standalone Windows systems, anddistributed servers.

BENEFITS • Six display sizes in keypad, touch screen, and keypad/touch screen combination options

• No hard drive, no fans, and no moving parts deliver superior ruggedness

• Modular design with separate display, logic, and communication modules

• Immediate startup with RSView Machine Edition pre-loaded and activated

• Easy to maintain through field-replaceable bezels and backlights

• Unit level immediate exchange for quick and easy replacement

• High-bright 12" touch screen display (over 1000 nits) provides an ideal solution for outdoor environments

• Windows CE operating system• No registration required• Shorter startup times• Instant power shutdown16

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew P

lus

and

Vers

aVie

w C

E

Page 2: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

17

Allen-Bradley Electronic Operator Interface >> PanelView Plus and VersaView

CE

ModularComponentsPanelView Plus and VersaView CEoffer component modularity so that design andmaintenance teams can choose the platforms that best fit their budgets, space requirements, and environmental conditions.

■ display/input modules for PanelView Plus and VersaView CE 7" to 15" terminals

■ common logic modules for PanelView Plus and VersaView CE 7" to 15" terminals

■ communication modules for PanelView Plus and VersaView CE 7" to 15" terminals

■ memory modules, RAM, and Flash for PanelView Plus and VersaView CE 7" to 15" terminals

PanelView Plus and VersaView CEcommunicate to all RockwellAutomation devices over the following networks:■ EtherNet/IP■ ControlNet■ DeviceNet■ Remote I/O■ DH-485■ DH+■ RS-232 (DF1, DH-485, and 25 multi-vendor drivers)

They also offer connectivity to many different controllers,including GE, Mitsubishi, Modbus, AutomationDirect, Omron,Siemens, and Square D.

Advanced GraphicFeaturesFor maximum systemoptimization and diagnostics,the PanelView Plus andVersaView CE let youcustomize your system view tospecific application needs:

■ 18-bit color graphics – to incorporate graphic pictures■ Trending – plot time based on x-y data, plot up to 8 pens

per trend■ Expressions – modify data based on conditions using

logic or mathematical function■ Data logging – record up to 300,000 values locally

or remotely■ Animation – easily create system simulation movements

Shorten Development TimeWith PanelView Plus and VersaView CE, designers can reusedevelopment efforts and share data across a wide variety ofplatforms and applications.

■ One common development software package – RSView Studio

■ FactoryTalk Diagnostics■ Direct referencing of controller tags eliminates duplicate

HMI and controller tag database

RSView StudioThe development software RSView Studio is available in two versions. RSViewStudio for Machine Edition is for developing Machine Edition projects only. RSViewStudio for RSView Enterprise configures both Machine Edition and SupervisoryEdition for distributed multi-server/multi-client applications. Both softwarepackages support PanelView Plus and VersaView CE application development.

9701-VWSTMENERSView Studio for Machine Edition Development Software

9701-VWSTENERSView Studio for RSView Enterprise Development Software

For complete HMI software information, see the Rockwell Software sectionof this publication or visit www.software.rockwell.com.

Page 3: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew P

lus

2218

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew P

lus

and

Vers

aVie

w C

E

JUST ENOUGH

For applications with limited budgets and requiring only basic PLC communications, PanelView Plus 400 and 600 offer RS-232 only terminals supporting DF1 and DH-485 protocols as well as 25 other multi-vendor PLC protocols.

AFFORDABLE BUT FLEXIBLEFor more distributed or complex applications requiring networked PLC communications, PanelView Plus 400 and 600 offerterminals with RS-232, on board Ethernet, and a network communications interface for adding optional communicationmodules. This means simultaneous communications with multiple networks. Product labeling options are also available.

OPTIMAL SERVICEABILITYPanelView Plus and VersaView CE 700 to 1500 terminals provide a variety of modular display sizes, memory, communication,and labeling options, giving OEMs and end users a standard base of common components and customized features to useacross multiple applications. Common components help reduce maintenance procedures and inventory costs.

Modularity – Choosing One That Fits Your Application Needs

Flexible USB peripheral support –keyboard, mouse, printer, and barcode scanners

Flexible peripheral support

Network communication modularity – DH+/RemoteI/O/DH-485, isolated RS-232

Product identification and keypadlegends for replacement andcustomization

RS-232 driver modularity fittingmany PLC configurations – DF1,DH-485, over 25 other multivendorPLC drivers available

RS-232 driver modularity fittingmany PLC configurations

Built-in Ethernet for PLC communications or data transfer

Driver modularity fittingmany PLC configurations

Flexible peripheral support

Display module for ease of replacement and interchangeability

Logic modules come standardwith built-in Ethernet, RS-232,two USB ports, and one compact flash Type I port

Available in different flash andmemory sizes

Optional communications modulesfor DH+, Remote I/O, DH485,ControlNet, and DeviceNet

Bezel module offers easy replacement

Product identification and keypadlegends for replacement and customization

Page 4: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

VersaView CE terminals offer the durability and reliability ofdedicated operator interface terminals plus the flexibility of an open computer. The result is a rugged terminalwith an open Windows CE operating system,RSView Machine Edition, and a suite of additionalapplications and ActiveX controls that allow you tomaximize your investment!

The following applications are pre-loaded oneach VersaView CE terminal:■ RSView Machine Edition

■ Microsoft® Internet Explorer

■ Terminal Services for running another computer's applications on the VersaView CE

■ Microsoft Windows Explorer

■ Adobe® PDF viewer

■ ActiveSync

■ Soft keyboard input panel

■ Command prompt (DOS-like)

The following applications are provided on anaccessory CD that ships with each terminal:■ Microsoft Word, Excel, and PowerPoint viewers for viewing training,

setup, or troubleshooting documents right on the terminal

■ WordPad text editor for editing documents on the terminal

■ JPEG and MPEG viewers for viewing machine support pictures and videos

■ FTP server for easy uploading and downloading of files between yourcomputer and the terminal

■ Virtual Network Computing (VNC) provides remote access from your computerto the terminal for viewing active screens or controlling the terminal

■ Backup/restore utility for duplicating and backing up terminals

■ Web server for viewing the current terminal screen, OS and ME versions,terminal temperature, memory usage, and event logs

■ Lockdown utility for keeping the user in RSView ME and away from OS desktop features

■ ActiveX controls for additional functionality in RSView ME:

• Program Launcher for running viewers, Internet Explorer, or any other executable

• Data Access Control for modifying timer, counter, integer, and other data tablevariables in PLCs, SLCs, and MicroLogix controllers

• Data Store for logging data in .csv format

• Web Browser for restricting users to certain websites19

Allen-Bradley Electronic Operator Interface >> VersaView CE

VERSAVIEW CE Operator Interface Terminals

Thin Client Technology

Thin client technology or server-basedcomputing enables any computer to accessMicrosoft Windows-based applications andUnix-based applications, such as wordprocessors, spreadsheets, or accountingprograms, from any web browser over theInternet or a corporate intranet without having toinstall the application on every desktop system.

The applications actually live and run onMicrosoft Terminal Services servers, not ondesktop systems. Applications are installed onMS Terminal Services servers in a centralcomputer room. All application processing isperformed on the Terminal Services server,not the desktop system. This means that only thescreen, keyboard, and mouse information arepassed to the client desktop system, as if youwere remotely controlling a Windowssession on the Microsoft Terminal Services Server.

Page 5: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

D I S P L A Y

Type Monochrome Passive Matrix, Film Compensated Super-Twist Nematic (FSTN) Color Active Matrix Thin Film Transistor (TFT)

Size 78 x 59 mm (3.7 in) 111 x 84 mm (5.5 in) 111 x 84 mm (5.5 in)

Resolution 320 x 240, 32 level grayscale 320 x 240, 18 bit color graphics

Brightness 50 cd/m2 Keypad 140 cd/m2; Touch 120 cd/m2 Keypad 140 cd/m2; Touch 110 cd/m2

Replaceable Backlight No

Operator Input Keypad Keypad, Analog Touch Screen, or Combination

Function Keys 8 Function Keys, F1-F8 10 Function Keys, F1-F10 10 Function Keys, F1-F10

Real time Clock Battery-backed time clock timestamps critical data. Accuracy +/-2 minutes per month

Memory Options Standard 64 MB/64 MB, Not ExpandableAvailable Flash/RAM Approximately 5 MB of available application memory.

E L E C T R I C A L

Communication Port RS-232 and (1) USB Only or Ethernet, RS-232, (1) USB, plus optional ControlNet, DeviceNet, DH-485, DH+ or Remote I/O modules

Power Requirements 18-30V DC or 85-264V AC @ 47-63 Hz

Power Consumption DC Power: 25 Watts max. (1.0A @ 24V DC) AC Power: 60 VA max.

Programming RSView Studio for Machine Edition or RSView Studio Enterprise Series

E N V I R O N M E N T A L

Operating Temperature 0 - 55°C (32 - 131°F)

Storage Temperature -25 – 70°C (-13 – 158°F)

Humidity 5 - 95%, noncondensing @ 0 - 55°C

Ratings NEMA 12, 13, 4X , IP54, IP65

Certifications cUL certified; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 2, Div 2, Groups F, G; Class 3, Div 1; CE marked; C-Tick

M E C H A N I C A L

Weight Keypad or .562kg(1.24 lb) .930kg (2.05 lb) .930kg (2.05 lb)Keypad/Touch

Weight Touch Only N/A .789kg (1.74 lb) .789kg (1.74 lb)

Dimensions Overall Keypad: Keypad or Keypad/Touch: (H x W x D) 152x185x90 mm 167x266x98 mm

(6.0x7.28x3.54 in) (6.58x10.47x3.86 in)Touch Only: 152x185x98 mm

(6.0x7.28x3.86 in)

Cutout Dimensions Keypad: Keypad or Keypad/Touch: 123x156 mm (4.86x6.15 in) 142x241 mm (5.61x9.50 in)

Touch Only: 123x156 mm(4.86x6.15 in)

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew P

lus

2220

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew P

lus

PanelView Plus Specifications – For catalog number selection, refer to page 68.

PanelView Plus 400 PanelView Plus 600 Grayscale PanelView Plus 600 Color

1 check for availability of outdoor rating

Page 6: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

Color Active Matrix Thin Film Transistor (TFT)

132 x 99 mm (6.5 in) 211 x 158 mm (10.4 in) 246 x 184 mm (12.1 in) 304 x 228 mm (15.1 in)

640 x 480, 18-bit color graphics 800 x 600, 18-bit color graphics 1024 x 768, 18-bit color graphics

300 cd/m2 300 cd/m2 300 cd/m2 or >1000 cd/m2 (high-bright display) 300 cd/m2

Field Replaceable Backlight No

Keypad, Analog Touch Screen, or Combination

22 Function Keys, 32 Function Keys, 40 Function Keys, 40 Function Keys, F1-F10 & K1-K12 F1-F16 & K1-K16 F1-F20 & K1-K20 F1-F20 & K1-K20

Battery-backed clock timestamps critical data

Standard 64 MB/64 MB; Extended: 128 MB/128 MB (for full color bitmaps or recording data);Standard: Approx. 13 MB flash; Extended: 115 MB flash available for application storage

Ethernet, RS-232, 2 USB plus optional communication modules

18-32V DC or 85-264V AC @ 47-63 Hz

70 Watts max, 2.9 amps at 24V DC (40 Watts nominal)

RSView Studio for Machine Edition or RSView Studio Enterprise Series

0 – 55°C (32 – 131°F)

-25 - 70°C (-13 - 158°F)

5 – 95%, noncondensing @ 0 – 55°C

NEMA 12, 13, 4X Indoor, (4X Outdoor with 1250 High-Bright) IP54, IP65

cUL certified; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 1, Zone 2, Group IIC; Class 2, Div 2, Groups F, G; Class 3, Div 1; CE marked; C-Tick

1.9 kg (4.2 lb.) 2.9 kg (6.3 lb.) 3.4 kg (7.6 lb.) 4.6 kg (10 lb.)

1.7kg (3.8 lb.) 2.6 kg (5.7 lb.) 3.2 kg (7.1 lb.) 4.2 kg (9.3 lb.)

Keypad or keypad/touch: Keypad or keypad/touch: Keypad or keypad/touch: Keypad or keypad/touch:193 x 290 x 55 mm 248 x 399 x 55 mm 282 x 416 x 55 mm 330 x 469 x 65 mm

(7.58 x 11.4 x 2.18 in) (9.77 x 15.72 x 2.18 in) (11.12 x 16.36 x 2.18 in) (12.97 x 18.46 x 2.55 in)Touch only: 179 x 246 x 55 mm Touch only: 248 x 329 x 55 mm Touch only: 282 x 363 x 55 mm Touch only: 330 x 416 x 65 mm

(7.04 x 9.68 x 2.18 in) (9.77 x 12.97 x 2.18 in) (11.12 x 14.3 x 2.18 in) (12.97 x 16.37 x 2.55 in)High-Bright Touch: 282 x 363 x 101.6 mm

(11.12 x 14.3 x 4 in)

Keypad or keypad/touch: Keypad or keypad/touch: Keypad or keypad/touch: Keypad or keypad/touch:167 x 264 mm (6.57 x 10.39 in) 224 x 375 mm (8.8 x 14.75 in) 257 x 390 mm (10.11 x 15.35 in) 305 x 419 mm (12 x 16.5 in)

Touch only: 154 x 220 mm Touch only: Touch and High-Bright Touch: Touch only: 305 x 391 mm(6.08 x 8.67 in) 224 x 305 mm (8.8 x 12 in) 257 x 338 mm (10.11 x 13.29 in) (12 x 15.4 in)

PanelView Plus 700 PanelView Plus 1000 PanelView Plus 1500

For most up-to-date specification information, visit www.ab.com/eoi/graphicterminals/panelview_plus

Allen-Bradley Electronic Operator Interface >> PanelView Plus

21

PanelView Plus 1250 andPanelView Plus 1250 High-Bright Touch

Page 7: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

2222

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Ver

saVi

ew C

E

D I S P L A Y

Size 6.5 in (165.1 mm) 10.4 in (264.16 mm) 12.1 in (307.34 mm) 15 in (381 mm)

Type Color active matrix thin film transistor (TFT)

Resolution 640 x 480, 24 bit color 800 x 600, 24 bit color 1024 x 768, 24 bit color

Brightness 300 cd/m2 300 cd/m2 300 cd/m2 or >1000 cd/m2 300 cd/m2

(high-bright display)

S Y S T E M C O M P O N E N T S

Expansion Slots 1 Compact Flash; ControlNet, DH+/DH-485/Remote I/O communication module option

Processor Type Intel Celeron 650 MHz

Flash Memory Standard: 128 MB; extended: 256 MB (20 MB required for OS and ME)

RAM Standard: 128 MB; extended: 256 MB

I/O 1 serial port, 2 USB ports, 1 10/100 Mbps Ethernet port

E L E C T R I C A L

Communication Ports RS-232, Ethernet and (2) USB, plus optional communication modules

Power Requirements 18-32V DC or 85-264V AC @ 47-63 Hz

Power Consumption 70 Watts max, 2.9 amps at 24V DC (40 Watts nominal)

Programming RSView Studio for Machine Edition or RSView Studio Enterprise Series

E N V I R O N M E N T A L

Operating Temperature 0 – 55˚C (32 – 131˚F)

Storage Temperature -25 – 70˚C (-13 – 158˚F)

Humidity 5 – 95%, non-condensing @ 0 – 55˚C

Vibration 0.012 in p-p, 10…57 Hz, 2g peak, 57…500Hz: operating and non-operating

Shock 15g operating, 30g non-operating

Ratings NEMA Type 12, 13, 4X 1, IP54, IP65

Certifications cUL; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 1, Zone 2, Group IIC;Class 2, Div 2, Groups F, G; Class 3, Div 1; CE marked; C-Tick

M E C H A N I C A L

Weight Keypad or 1.9 kg (4.2 lb.) 2.9 kg (6.3 lb.) 3.4 kg (7.6 lb.) 4.6 kg (10 lb.)Keypad/Touch

Weight Touch Only 1.7kg (3.8 lb.) 2.6 kg (5.7 lb.) 3.2 kg (7.1 lb.) 4.2 kg (9.3 lb.)

Dimensions Overall Keypad or keypad/touch: Keypad or keypad/touch: Keypad or keypad/touch: Keypad or keypad/touch:(H x W x D) 193 x 290 x 55 mm 248 x 399 x 55 mm 282 x 416 x 55 mm 330 x 469 x 65 mm

(7.58 x 11.4 x 2.17 in) (9.77 x 15.72 x 2.17 in) (11.12 x 16.36 x 2.17 in) (12.97 x 18.46 x 2.55 in)Touch only: Touch only: Touch only: Touch only:

179 x 246 x 55 mm 248 x 329 x 55 mm 282 x 363 x 55 mm 330 x 416 x 65 mm(7.04 x 9.68 x 2.17 in) (9.77 x 12.97 x 2.17 in) (11.12 x 14.3 x 2.17 in) (12.97 x 16.37 x 2.55 in)

High-Bright Touch282 x 363 x 101.6 mm

(11.12 x 14.3 x 4 in)

Cutout Dimensions Keypad or keypad/touch: Keypad or keypad/touch: Keypad or keypad/touch: Keypad or keypad/touch:(H x W) 167 x 264 mm 224 x 375 mm 257 x 390 mm 305 x 419 mm

(6.57 x 10.39 in) (8.8 x 14.75 in) (10.11 x 15.35 in) (12 x 16.5 in)Touch only: Touch only: Touch and High-Bright Touch: Touch only:

154 x 220 mm 224 x 305 mm 257 x 338 mm 305 x 391 mm(6.08 x 8.67 in) (8.8 x 12 in) (10.11 x 13.29 in) (12 x 15.4 in)

VersaView CE Specifications – For catalog number selection, refer to page 68.

1 Check for availability of outdoor rating

VersaView CE 700H VersaView CE 1000H VersaView CE 1250H VersaView CE 1500Hand 1250H

High-Bright Touch

For most up-to-date specification information, visit www.ab.com/versaview/6182h.html

Page 8: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

23

Allen-Bradley Electronic Operator Interface >> PanelView Plus and VersaView

CE

Typi

cal P

anel

View

Plu

s 70

0-15

00an

d Ve

rsaV

iew

CE

700H

-150

0H

Width Height Depth A Depth B Cutout width Cutout height

400 Keypad 185 mm 152 mm 60 mm 90 mm 156 mm 123 mm(7.28 in) (6.00 in) (2.35 in) (3.53 in) (6.15 in) (4.86 in)

600 Keypad or Keypad/Touch 266 mm 167 mm 68 mm 98 mm 241 mm 142 mm(10.47 in) (6.58 in) (2.68 in) (3.86 in) (9.50 in) (5.61 in)

600 Touch 185 mm 152 mm 68 mm 98 mm 156 mm 123 mm(7.28 in) (6.00 in) (2.68 in) (3.86 in) (6.15 in) (4.86 in)

700 Keypad or Keypad/Touch 290 mm 193 mm 55 mm (2.17 in) 83 mm (3.27 in) 264 mm 167 mm(11.40 in) (7.58 in) display to display to (10.39 in) (6.59 in)

logic module comm modules

700 Touch 246 mm 179 mm 55 mm (2.17 in) 83 mm (3.27 in) 220 mm 154 mm (9.68 in) (7.04 in) display to display to (8.67 in) (6.08 in)

logic module comm modules

1000 Keypad or Keypad/Touch 399 mm 248 mm 55 mm (2.17 in) 83 mm (3.27 in) 375 mm 224 mm(15.72 in) (9.77 in) display to display to (14.75 in) (8.8 in)

logic module comm modules

1000 Touch 329 mm 248 mm 55 mm (2.17 in) 83 mm (3.27 in) 305 mm 224 mm(12.97 in) (9.77 in) display to display to (12.00 in) (8.8 in)

logic module comm modules

1250 Keypad or Keypad/Touch 416 mm 282 mm 55 mm (2.17 in) 83 mm (3.27 in) 390 mm 257 mm(16.36 in) (11.12 in) display to display to (15.35 in) (10.11 in)

logic module comm modules

1250 Touch 363 mm 282 mm 55 mm (2.17 in) 83 mm (3.27 in) 338 mm 257 mm(14.30 in) (11.12 in) display to display to (13.29 in) (10.11 in)

logic module comm modules1250 High-Bright 1250 High-Bright

39 mm (1.519") 74 mm (2.903")

1500 Keypad or Keypad/Touch 469 mm 330 mm 65 mm (2.55 in) 93 mm (3.65 in) 419 mm 305 mm(18.46 in) (12.97 in) display to display to (16.50 in) (12.00 in)

logic module comm module

1500 Touch 416 mm 330 mm 65 mm (2.55 in) 93 mm (3.65 in) 391 mm 305 mm(16.37 in) (12.97 in) display to display to (15.40 in) (12.00 in)

logic module comm module

PanelView Plus and VersaView CE Dimensions

AB

AB

Typi

cal P

anel

View

Plu

s 40

0-60

0

Page 9: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

2224

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pane

lVie

w P

lus

and

Vers

aVie

w C

E

PanelView Plus and VersaView CENetwork ConnectionsPanelView Plus and VersaView CE terminals are designed with modularity in mind for

maximum flexibility. This means that as your control system needs change, so can

the communications.

Use RSView Studio to upload and download project files with direct serial connection –

over the network or through gateway connections. Compact flash cards provide an

alternative to connecting a PC to the PanelView Plus and VersaView CE.

PanelView Plus and VersaView CE Network Connections – Runtime Operation

Network MicroLogix SLC-500, SLC 5/03 SLC 5/04 SLC 5/05 PLC-5 ControlLogix FlexLogix CompactLogixConnection 5/01, 5/02

Remote I/O n/a with with with with yes with n/a n/a1747-SN 1747-SN 1747-SN 1747-SN 1756-DHRIO

DH+ n/a n/a n/a yes n/a yes with 1756-DHRIO 2 n/a n/a

DF1 Ch. 0 n/a Ch. 0 Ch. 0 Ch. 0 Ch. 0 Serial Port 2 Serial Port 2 Serial Port

DH-485 (RS-485 with AIC yes yes with AIC with AIC n/a with AIC to with AIC to with AIC tophysical connection) to AIC+5 to AIC+ to to AIC+ to AIC+ to AIC+ to AIC+ to

Ch. 0 1/5 Ch. 0 1/5 Ch. 0 1/2/5 Ch. 0 1/2/5 Ch. 0 1/2/5

DH-485 (RS-232 yes with AIC+ Ch. 0 Ch. 0 Ch. 0 n/a Serial Port 2 Serial Port 2 Serial Port 2

physical connection) to AIC 1/6

ControlNet 3 n/a n/a 1747-KFC15 Unscheduled PLC-5C with 1756-CNB 2 with n/aUnscheduled and 1747-SCNR Scheduled 1788-CNC or

Scheduled 1788-CNB 2

DeviceNet with 1761- 5/02 with with 1747- with 1747- with 1747- with 1771- with 1756-DNB with 1788- with 1769-NET DNI 1747-SDN SDN SDN SDN SDN DNBO SDN

EtherNet/IP yes 4 n/a yes 4 yes 4 yes PLC-5E, or with 1756-ENET with yes 2/ 4/ 7

1771-SN or 1756-ENBT 2 1788-ENBT 2

1. For isolation purposes if not used on the same power supply.2. Symbolic (CIP) addressing. Example: Address = TankLevel.3. PanelView Plus 700-1500 operator interface terminals.4. Ethernet is supported through the PanelView Plus serial port with

1761-ENI. Check availability of direct Ethernet controller with an ENI.5. RS-485 to AIC bridged to AIC+ to device.6. RS-232 to AIC bridged to a AIC+ to device.7. L35E

PanelView Plus and VersaView CE Application FileLoad/Download Supported Connections

PanelView Plus Network PanelView Plus Connector Cables and PC Hardware

Ethernet via EtherNet/IP Standard RJ45 Standard Ethernet cables

ControlNet1 BNC or NAP 1784-PCICS or 1784-PKTCS

Serial RS-232 via DF1 9-pin D-shell 2711-NC13 or equivalent

Data Highway Plus 3-pin terminal 1784-PKTX

DH-485 6-pin terminal 1784-PKTX2

(Serial RS-232 or RS-385)

1 PanelView Plus 700-1500 only

2 Serial DH-485 not supported on desktop by RSLinx Enterprise

Page 10: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

Allen-Bradley Electronic Operator Interface >> PanelView Plus

25

When You Choose MigrationWhen choosing to migrate your current products to new products, look at the best product for that migration and consider what you need. Do you want a simple drop-inreplacement? Do you want to take advantage of the latest HMI technology? Following is information that can help you when considering your migration choices:

RSView Machine Edition Import WizardBecause application development is a significant expense,Rockwell Automation has taken steps to minimize the impact ofmigrating applications to a new environment. RSView MachineEdition Import Wizard helps bring existing applications forward.

When a new RSView Machine Edition project is created, there is anoption to import PanelBuilder 1400e .pvc and PanelBuilder32 .pbaand .pva application files. The Machine Edition Import Wizardsteps you through a few options such as scaling to a new screenresolution size, then converts objects, text, tags, and communicationconfigurations to ones that are available in Machine Edition. The conversion gives you a head start in laying out screens andcreating tag addresses for new systems.

For more information on RSView Machine Edition, see theRockwell Software product section of this publicationor visit www.software.rockwell.com.

Migrating to a PanelView Plus using an existing Remote I/Onetwork involves additional engineering development time. The controller’s ladder logic and the HMI application must bemodified to support the new Remote I/O functionality of thePanelView Plus and RSView ME. The extra engineering time is worth the effort, as the advanced graphic capabilities, animationeffects, and data logging features of RSView ME will help increasemachine and system productivity.

PanelView 1200 and PanelView 1400e MigrationThe PanelView 1000e is the most cost-effective long-termsolution when migration from a PanelView 1200 or PanelView1400e. Use PanelBuilder 1400e software to directly convertPanelView 1200 applications and use available adapter plates to physically replace the terminal in the existing cutout. Thismigration can be accomplished in a short amount of time and provides the same functionality found in PanelView 1200 orPanelView 1400e.

The PanelView Plus 1500 or 1250 is an alternate way to migrate a PanelView 1200 or PanelView 1400e. Use an availableadapter plate to physically replace the terminal in the existingcutout. Use PanelBuilder 1400e software and RSView Studio to import the displays of the PanelView 1200 or PanelView 1400e application, which can be used as a starting point when recreating the application file. Not all PanelBuilder 1400e objects directly convert; however, most functionality can beachieved using other RSView Machine Edition (ME) objects andfunctions. Some engineering time will be needed to incorporate the advanced graphic capabilities, animation effects, and datalogging features of RSView ME. This strategy works well whenmigrating systems that communicate on Ethernet, DH+, DH-485,and DF1. When the entire control system, including the controllerand network, is being replaced, this is the preferred strategy.

Page 11: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

2226

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew P

lus

Existing Terminal Drop-in Replacement Adapter Plate Needed

PanelView 550 or 600 Touch PanelView Plus 600 Touch, PanelView Plus 400 —

PanelView 550 Keypad or Keypad/Touch PanelView Plus 600 Keypad or Keypad/Touch PanelView Plus 400 and 600 Touch

PanelView 600 Keypad or Keypad/Touch PanelView Plus 700 Keypad or Keypad/Touch PanelView Plus 600 Keypad or

Keypad/Touch

PanelView 900 PanelView Plus 1000 PanelView Plus 700

PanelView 1000, 1000e PanelView Plus 1250 PanelView Plus 1000

PanelView 1200, 1200e CRT Touch Not Available PanelView Plus 1000 1

PanelView Plus 1250 2

PanelView 1200, 1200e CRT Keypad PanelView Plus 1500 3 PanelView Plus 1250

PanelView 1400, 1400e CRT PanelView Plus 1500 3 PanelView Plus 1250

RAC6182: 7.7" color Not Available Not Available

RAC6182: 12.1" color PanelView Plus or VersaView CE 1250 PanelView Plus or VersaView CE 1000H

1 Check for adapter plate availability 2 Requires modification of cutout 3 Adapter plate required for a stud-mounted PanelView

Cutout MigrationConsider both the display size and the unit size when migrating to a new operator interface. PanelView Plus uses the same cutoutsas existing PanelView product cutouts, yet offers a larger display area. When maintaining the same screen size, adapter plates areavailable to accommodate new PanelView Plus cutout.

When You Choose Migration (cont.)

Page 12: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

27

Allen-Bradley Electronic Operator Interface >> PanelView Standard

Allen-Bradley PanelView Standard operator interfaceterminals are extraordinary performers in the real world ofcontrol system automation. You’ll find them working hardaround the world, supporting the automotive, food andbeverage, pulp and paper, water and wastewater, andpetrochemical industries. Each terminal carries UL, C-UL/CSA, and CE certifications. They are rated for NEMA4X (indoor) (IP54, IP65) and approved for Class 1, 2, and 3Division 2 operation. These terminals are engineered forscalability, reliability, and compatibility for lower cost ofownership and improved productivity.

PanelView terminals exemplify Rockwell Automation’scommitment to the highest standards of productdependability, technological innovation, and performance, and are backed with the highest levels of customer serviceand support in the industry.

For a complete operator interface solution designed forrugged performance in a standalone or network environment,PanelView Standard is an extraordinary choice.

Proven Performance. Legendary Reliability.

PANELVIEW STANDARDOperator Interface Terminals

Page 13: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

2228

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew S

tand

ard

PanelView terminals support ATA memory card usage.

PanelView Standard Terminal Features■ Over 140 terminal combinations to fit any operator interface application ■ 12 display combinations, from 3-inch to 10-inch, in color, grayscale, or

monochrome, each designed for minimal installation depth with maximumviewing angles

■ Keypad, touch screen, or keypad/touch screen combinations for convenient andflexible operator input

■ RS-232 printer port to print alarms, alarm lists, triggered messages, and triggeredstates of a multi-state indicator

■ ATA PC Flash memory cards for fast application downloads, convenient storageof Universal Language Support fonts, and simplified firmware upgrades

■ Field-replaceable backlights to extend screen life of PanelView 600 and 1000(color) terminals

■ 100,000 hour LED backlight for PanelView 300, 300 Micro, and 550

PanelView Standard Communications■ EtherNet /IP

■ ControlNet

■ DeviceNet

■ Data Highway Plus

■ Remote I/O

■ DH-485

■ RS-232 (DH-485 protocol)

■ RS-232 (DF1 protocol)

Page 14: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

Allen-Bradley Electronic Operator Interface >> PanelView Standard

29

PanelBuilder32 applications easily migrate between terminals

• Local Language Support

Now you can develop your PanelBuilder32 applications inChinese! New in version 3.82.01, PanelBuilder32 supportsChinese and over 45 other languages.

Alarm lists record and display important alarm data

High Performance Functions

PanelBuilder32 software supports the entire family of PanelView Standard terminals, allowing easy conversion and reuse of existing applications.

• Full library of operator devices

• Alarm messages for instant notification

• Multiple application files open at same time

• Extensive ControlLogix support

• Support of up to five languages in a single application

• Remote device configuration for application fileupload/download over networks using RSLinx andControlLogix Gateway

• Import/export capability for the RSLogix softwarefamily of programming software for RockwellAutomation logic controllers

• Use Microsoft tools to create, sort, and organize your control tags

• Open, reuse, and save legacy PanelView Standard applications, maintainingthe value in your PanelView investment

PanelBuilder32 Software For quick and easy screen configuration

Alarm banner alerts operators tofault conditions

• Advanced Alarm Capabilities

• Screen Security

Page 15: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

550300

2230

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew S

tand

ard

Designed for low-end graphical or text only operator interface applications,the PanelView 300 and 300 Micro terminals' LCD monochrome graphicdisplay and feature-rich design allow for high performance in applicationsthat demand a compact, less expensive interface.

Keypad, touch screen, or keypad/touch screen combination

The PanelView 550 pixel graphic display terminals are cost-effectiveways for end users and OEMs to incorporate high performance operatorinterface devices into applications or machines where panel space islimited. These terminals offer a flat panel blue-mode display with long-life backlight to lower the cost of ownership without losing PanelViewfamily functionality.

PanelView 550

PanelView 300 and 300 Micro

PanelView Standard Product Offering

Page 16: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

600

1000

Allen-Bradley Electronic Operator Interface >> PanelView Standard

31

Keypad, touch screen, or keypad/touch screen combination

The PanelView 600 keypad, keypad/touch, andtouch only terminals are high performance colorterminals for applications where color graphicdisplays are required and panel space is limited.

• 6.0” (152.4 mm) diagonal TFTactive matrix color display

• 320x234 pixel resolution

• 10 relegendable function keys, numeric keypad, cursor controlkeys

• Power 85-264V AC or 18-32V DC• 128 touch cells (touch and

combo terminal only)

Keypad, touch screen, or keypad/touch screen combination

The PanelView 1000’s flat panel color or grayscale display, modest installed depth, operator input capabilities, alarmfunctions, and communication options have made it a popular workhorse in the operator interface market.

Choose between keypad or touch screen input with either color or grayscale display and seven different communicationoptions. All configurations network with the Allen-Bradley family of controllers as well as other PLC brands.

PanelView 600

PanelView 1000

Page 17: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

Pane

lVie

w 3

00

Pane

lVie

w 5

50

2232

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew S

tand

ard

PanelView 550

266 mm(10.47 in)

106 mm(4.17 in)

86 mm(3.39 in)

167 mm(6.57 in)

Top View

PanelView 550

185 mm(7.28 in)

152 mm(6.00 in)

64 mm(2.54 in)

82 mm(3.20 in)

Top View

197 mm(7.76 in.) 69 mm

(2.73 in.)82 mm(3.21 in.)

140 mm(5.53 in.)

Pane

lVie

w 3

00 M

icro

PanelView Standard Dimension Drawings

Page 18: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

Pane

lVie

w 6

00

Allen-Bradley Electronic Operator Interface >> PanelView Standard

33

Pane

lVie

w 1

000

PanelView 1000

Top View

167 mm(6.57 in)

90 mm(3.54 in)

6.9 mm(0.27 in)

370 mm(14.58 in)

282 mm(11.11 in)

PanelView 1000

423 mm(16.64 in)

282 mm(11.11 in)

Top View

167 mm(6.57 in)

90 mm(3.54 in)

6.9 mm(0.27 in)

Page 19: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

D I S P L A Y

Type Monochrome transflective LCD with integral LED backlight Monochrome LCD Blue Mode Display

Size: 2.87" x1.67" (73 mm x 42 mm) 4.75" x 2.38" (120 mm x 60 mm)

Replaceable Backlight N/A – 100,000 hour LED backlight life

Operator Input Keypad Keypad Keypad or Combination Keypad Touchscreen Onlyand Touchscreen

Touch Cells N/A N/A 128 128

Function Keys 4 (F1 - F4) 8 (F1 - F8) 10 (F1 - F10) N/A4 Nav/Function Keys

Real time Clock Battery-backed clock timestamps critical data

Application Memory 170K application runtime; 240K Flash (application objects + text + bitmaps)

ATA Memory Card N/A Supported

E L E C T R I C A L

Communication Port RS-232 (DH-485 protocol), DeviceNet, DH-485, RS-232 EtherNet/IP, DeviceNet, ControlNet, DH+, Remote I/O, DF1, 8-pin Mini (DH-485 protocol), DF1 DH-485, RS-232 (DH-485 protocol), DF1DIN connector

RS-232 Printer Port N/A 1200, 2400, 9600, 19200 baud rate 1

Power Requirements AC: N/A DC: 11-30V DC AC: N/A DC: 18-32V DC AC: 85-264V AC DC: 18-30V DC AC: N/A DC: 18-32V DC47-63 Hz

Power Consumption AC: N/A DC: 2.5 Watts AC: N/A DC: 10 Watts AC: 45 VA max. DC: 18 Watts max. AC: N/A DC: 18 Watts max. max. (0.105A@24V DC) max. (0.42A@24V DC) (0.75A@24V DC) (0.75A@24V DC)

Programming PanelBuilder32 (Windows based)

E N V I R O N M E N T A L

Operating Temperature 0 – 55°C (32 – 131°F)

Storage Temperature -20 – 85°C (-4 – 188°F) -25 – 70°C (-13 – 158°F) -20 – 70°C (-4 – 158°F)

Humidity 5 – 95%, noncondensing 5 – 95%, noncondensing @ 0 – 30°C@ 0 – 55°C

Ratings NEMA Type 12, 13, 4x (indoor only), IP54, IP65

Certifications cUL certified; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 1 Zone 2; Class 2, Div 2, Groups F, G; Class 3, Div 1; CE marked; C-Tick

W E I G H T

Keypad 10 oz. (284 g) 1.484 lbs. (673 g) 2.7 lbs (1.2 kg) N/A

Touch Screen N/A N/A N/A 2.1 lbs. (0.93kg)

D I M E N S I O N S

Keypad (H x W x D) 5.23" x 4.38" x 1.87" 7.76" x 5.51" x 3.21" 6.6" x 10.5" x 4.2" N/A(133 x 111 x 48 mm) (197 x 140 x 82 mm) (167.6 x 266.7 x 106.7 mm)

Touch Screen N/A N/A 6.6" x 10.5" x 4.2" 5.92" x 7.21" x 3.8"(H x W x D) (167.6 x 266.7 x 106.7 mm) (152 x 185 x 96 mm)

2234

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew S

tand

ard

PanelView Standard Specifications – For catalog number selection, refer to page 68.

PanelView 550 PanelView 300 PanelView 550T PanelView 300 Micro

1 PanelView 300 Printer Port or DeviceNet option only.

Page 20: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

For most up-to-date specification information, visit www.ab.com/eoi/graphicterminals/panelview_standard/index.html

Allen-Bradley Electronic Operator Interface >> PanelView Standard

35

Color Active Matrix Color Active Matrix Black/WhiteThin Film Transistor (TFT) Thin Film Transistor (TFT) Monochrome

4.54" x 3.4" (115 mm x 86 mm) 4.54" x3.43" (115 mm x 87 mm) 8.3" x 6.2" (211 mm x 158 mm)

Field Replaceable N/A Field replaceable backlight Field replaceable backlight for Series C and later

Keypad or Combination Keypad Touchscreen Only Keypad or Touchscreenand Touchscreen

128 384

10 (F1 - F10) N/A 16 (F1 - F16)

Battery-backed clock timestamps critical data

190K application runtime; 240K Flash 190K application runtime; 240K Flash 310K application runtime; 1008K Flash (application objects + text + bitmaps)(application objects + text + bitmaps)

Supported

EtherNet/IP, DeviceNet, ControlNet, DH+, Remote I/O, DH-485, RS-232 (DH-485 protocol), DF1

1200, 2400, 9600, 19200 baud rate

AC: 85-264V AC DC: 18-32V DC AC: N/A DC: 18-32V DC AC: 85-264V AC DC: 18-32V DC AC: 85-264V AC DC: 18-32V DC47-63 Hz 47-63 Hz 47-63 Hz

AC: 60 VA max. DC: 34 Watts max. AC: N/A DC: 24 Watts max. AC: 70 VA max. DC: 27 Watts max. AC: 100 VA max. DC: 40 Watts max.(1.9A@24V DC) (1.0A@24V DC) (2A@24V DC) (1.74A@24V DC)

PanelBuilder32 (Windows based)

0 – 55°C (32 – 131°F) 0 – 50°C (32 – 122°F) 0 – 55°C (32 – 131°F)

-25 – 70°C (-13 – 158°F)

5 – 95%, noncondensing @ 0 – 55°C 5 – 95%, non-condensing @ 0 – 40°C 5 – 95%, noncondensing @ 0 – 55°C

NEMA Type 12, 13, 4x (indoor only), IP54, IP65

cUL certified; UL listed; Class 1, Div 2, Groups A, B, C, D; Class 1 Zone 2; Class 2, Div 2; Class 3, Div 1; CE marked; C-Tick

4.4 lbs (2 kg) N/A 8.2 lbs (3.7 kg) 7.2 lbs (3.3 kg)

N/A 2.3 lbs. (1 kg) 7.9 lbs (3.6 kg) 7.0 lbs (3.2 kg)

7.55" x 11.40" x 4.57" N/A 11.1" x 16.6" x 4.4"(192 x 290 x 116 mm) (282 x 423 x 112 mm)

7.55" x 11.40" x 4.57" 6.00" x 7.28" x 3.80" 11.1" x 14.6" x 4.4"(192 x 290 x 116 mm) (152 x 185 x 96 mm) (282 x 370 x 112 mm)

PanelView 1000 ColorPanelView 600T PanelView 1000Grayscale

PanelView 600

Page 21: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

2236

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Pan

elVi

ew S

tand

ard

PanelViewStandardNetworkConnectionsBecause PanelView

Standard terminals offer

such flexible communication

options, you can optimize

your operator interface

needs to your control or

process architecture. Or, as

your control system needs

change, so can your operator

interface system.

Along with flexible network

connections for runtime

operation, you have multiple

options for uploading and

downloading application

files with PanelBuilder32 –

direct, over the network,

or via a ‘Pass Through’ or

‘Gateway’ connection. And

don’t forget ATA memory

cards for easy file transfers.

Standard Network Connections – Runtime OperationNetwork Connection MicroLogix SLC-500, 5/01, 5/02 5/03 5/04 5/05 PLC-5 ControlLogix

Remote I/O n/a 5/02 with 1747-SN with 1747-SN with 1747-SN yes with 1756-DHRIO**with 1747-SN

DH+ n/a n/a n/a yes n/a yes with 1756-DHRIO**

DF1 with AIC+* n/a Ch. 0 Ch. 0 Ch. 0 Ch. 0 yes

DH-485 (RS485 with AIC+ yes yes with AIC+ with AIC+ n/a n/aphysical connection) to Ch. 0 to Ch. 0

DH-485 (RS-232 with AIC+* with AIC+ Ch. 0 Ch. 0 Ch. 0 n/a n/aphysical connection)

DeviceNet with 1761- NET DNI 5/02 with 1747-SDN with 1747-SDN with 1747-SDN with 1747-SDN with 1771-SDN with 1756-DNB

ControlNet n/a n/a no no no PLC-5C with 1756-CNB***

EtherNet/IP with n/a n/a n/a yes PLC-5E, with 1756-ENET***1761-NET-ENI 1785-ENET

* For isolation purposes if not on the same power supply** Legacy mode. Example: address = N7:0*** Symbolic (CIP) addressing. Example: address = tank level

PanelView Standard Application File Upload/Download Direct and Network Connections PanelView Type Direct Connection PC (with PanelBuilder32) Network Connection PC (with PanelBuilder32)

to PanelView over NetworkEtherNet/IP 2711-NC13 (via RS-232 printer port) Yes – via Ethernet Port

DeviceNet 2711-NC13 (via RS-232 printer port) Yes – via PV DeviceNet port

ControlNet 2711-NC13 (via RS-232 printer port) Yes – via PV ControlNet port

Data Highway Plus 2711-NC13 (via RS-232 printer port) Yes – via PV DH+ port

Remote I/O 2711-NC13 (via RS-232 printer port) N/A – use a Pass-Through connectionDH-485 (RS-485 port) 1747-PIC* or AIC+ module Yes – via PV DH-485 port

DH-485 (RS-232 port) 2711-NC13 (via RS-232/DH-485 port) or Yes – via PV RS-232 (DH-485) portPV 300 Micro: 2711-CBL-PM05 or -PM10 (select terminals only)

DF1 2711-NC13 (via RS-232 port) or 2711-NC13 N/A – use a Pass-Through connection

(via RS-232 printer port – select terminals only)PV300 Micro: 2711-CBL-PM05 or -PM10

* When connecting a personal computer to a PanelView Standard terminal, using a PIC without a controller connected, you need a power supply (1747-NP1)

PanelView Standard Application File Upload/DownloadPass-Through & Gateway Connections

PC Network (PC to Controller) Controller*/Gateway PanelView Network (Controller to PanelView)Ethernet ControlLogix/Gateway ControlNet, DeviceNet, Remote I/O, DH+

PLC-5 DeviceNet, Remote I/OSLC 5/05 DeviceNet, Remote I/O, DH-485, DF1

ControlNet ControlLogix/Gateway DeviceNet, Remote I/O, DH+PLC-5 DeviceNet, Remote I/O

DH+ PLC-5 DeviceNet, Remote I/OSLC 5/04 DeviceNet, Remote I/O, DH-485, DF1

DH-485 SLC 5/03, 5/04 , 5/05 DeviceNet, Remote I/OSLC 5/04 DH+

DF1 ControlLogix/Gateway ControlNet, DeviceNet, Remote I/OSLC 5/03, 5/04, 5/05 DeviceNet, Remote I/OSLC 5/04 DH+

* The controller must support PC network as well as PanelView network. Consult controller manual for details

Page 22: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

Allen-Bradley Electronic Operator Interface >> PanelView ‘e’

37

PANELVIEW ‘E’Operator Interface Terminals

Using PanelView 1200?

We can help you leverage your PanelView 1200investment by moving your current application to a PanelView 1000e.

Migrate your older PanelView (2711-TA1, -TC1, -KA1, -KC1) to a PanelView ‘e’ graphic terminal.

Why migrate? It's easy!

Yes, you can reuse your application files – no need to reprogram.

Yes, you can use existing panel cutouts. Adapterplates are available.

Yes, your PLC program and Remote I/O networkfunctionality are maintained, with no PLC or RemoteI/O network changes necessary.

What’s the advantage?

You’ll have a new terminal with full factorywarranty, minimizing repair cycle costs anddowntime concerns.

You’ll be prepared to take advantage of theflexibility and scalability available in RockwellAutomation’s ViewAnyWare strategy – a fullenterprise visualization strategy with a suite ofmonitoring and control solutions.

Plus you receive more functionality and features to enhance your application.

Designed with high performance HMI functionality forcomplex process and large-scale control applications,these operator interface terminal workhorses providepowerful data processing capabilities, enhancedgraphics and functions, flexible operator interfaceoptions, and powerful configuration software.

24mm(0.94")

18mm(0.69")

18mm(0.7") 13mm

(0.5")

23mm(0.9")

14mm(0.55")

30mm(1.2")

Clip Slot

27mm(1.06")

3.81mm(0.15") 35mm

(1.37")

114mm(4.48")

114mm(4.48")

22mm(0.85")

92mm(3.64")

106mm(4.17")

282mm(11.12")

30mm(1.2")

24mm(0.96")

18mm(0.69")

113mm(4.45")

255mm(10.03")

174mm(6.83")

224mm(8.43")

157mm(6.18")

17mm(.65")

282mm(11.11")

95mm(3.75")

Allow 3.75" at this sideinternally so that the unitcan be opened for replacingbacklight module.

PanelView 1000e Touch Screen Terminals

35mm(1.37")

37mm(1.46")

92mm(3.64")

81mm(3.2")

138mm(5.43")

24mm(0.94")

18mm(0.69")

282mm(11.12")

24mm(0.96")

18mm(0.69")

113mm(4.45") 173mm

(6.8")

423mm(16.64")

18mm(0.7")

23mm(0.9")

13mm(0.53")

14mm(0.55")

30.4mm(1.2")

Clip Slot

27mm(1.06")

3.81mm(0.15")

114mm(4.48")

114mm(4.48")

255mm(10.03")

224mm(8.43")

156mm(6.15")

156mm(6.15")

17mm(.65")

282mm(11.11")

PanelView 1000e Keypad Terminals

Page 23: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

For most up-to-date specification information, visit www.ab.com/eoi/graphicterminals/panelview_e/index.html2238

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

Al

len-

Brad

ley

Elec

troni

c Op

erat

or In

terfa

ce >

> P

anel

View

‘e’

PanelView ‘e’ Specifications – For catalog number selection, refer to page 68.

PanelView 1000e PanelView 1400e*

D I S P L A Y

Type Color, Active Matrix, Thin Film Transistor (TFT) Color CRT Display, Configurable VGA or SVGA

Size 10.4 inch (26.4 cm) diagonal 14 inch (35.5 cm) diagonal (nominal display size approx. 12" (30 cm))

Replaceable Backlight Field Replaceable Backlight N/A

Operator Input Keypad or Touchscreen

Touch Cells Up to 192 (analog resistive)

Function Keys 21 (F1 – F21)

Real Time Clock Battery-backed clock timestamps critical data

Application Memory 2.25 MB On-Board Flash; expandable to 15.75 MB with external PC memory card

Programming PanelBuilder 1400e (Windows-based)

E L E C T R I C A L

Communication Port ControlNet, DH+, Remote I/O

RS-232 Printer Port 1200, 2400, 9600, 19200 baud rate

Power Requirements AC: 90-132 or 180-264V AC, DC: N/A

Power Consumption 90VA max 240VA maximum70W max 100W maximum

CRT degauss on powerup5.5 Amps @ 115V for 400 ms11 Amps @ 240V for 400 ms

E N V I R O N M E N T A L

Operating Temperature 0 – 50°C (32 – 122°F)

Storage Temperature -25 – 60°C (-13 – 140°F) -40 – 85°C (-40 – 185°F)

Humidity Rating 95% Humidity (noncondensing) @ 50°C (122°F) 95% Humidity (noncondensing) @ 30°C (86°F)

Ratings NEMA Type 12 (Indoor Use Only), 4X, IP66 (Indoor Use Only) NEMA Type 12 (Indoor Use Only), 4X, IP65 (Indoor Use Only)

Certifications UL 50, 1992, ENCL 4X,12 (Indoor Use Only)CSA C22-2 No. 94-M91, ENCL 4X, 12 (Indoor Use Only)

W E I G H T

Keypad 11.6 lbs (5.3 kg) 40.1 lbs (18.2 kg)

Touch Screen 11.3 lbs (5.1 kg) 38.7 lbs (17.6 kg)

D I M E N S I O N S

Keypad (H x W x D) 11.1" x 16.6" x 6.8" 14" x 19" x 16.7"(282 x 423 x 174 mm) (355 x 483 x 424 mm)

Touch Screen 11.1" x 14.6" x 6.8" 14"x 17.4" x 16.7"(H x W x D) (282 x 370 x 174 mm) (355 x 442 x 424 mm)

* PanelView 1400e is available through Rockwell Automation’s Custom Classics program. For more information, visit www.rockwellautomation.com/products/cust_classics.html.

Page 24: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

PanelView 'e' Application File Upload/Download Direct and Network Connections

PanelView ‘e’ Type Direct Connection PC Network Connection PC(with PanelBuilder 1400e) (with PanelBuilder 1400e)

to PanelView 'e' over Network

ControlNet 2711-NC13 Yes – via PVe ControlNet port(via RS-232 printer port)

Data Highway Plus 2711-NC13 Yes – via PVe DH+ port(via RS-232 printer port)

Remote I/O 2711-NC13 N/A – Use a pass-through(via RS-232 printer port) connection

PanelView 'e' Application File Upload/Download Pass-Through & Gateway Connections

PC Network Controller*/Gateway PanelView 'e' Network(PC to Controller) (Controller to PanelView 'e')

Ethernet ControlLogix/Gateway ControlNet, Remote I/O

PLC-5 Remote I/O

SLC 5/05 Remote I/O

ControlNet ControlLogix/Gateway Remote I/O

PLC-5 Remote I/O

DH+ PLC-5 Remote I/O

SLC 5/04 Remote I/O

DF1 SLC 5/03, 5/04, 5/05 Remote I/O

SLC 5/04 DH+

*The controller must support PC network as well as PanelView 'e' network. Consult controller manual for details

Allen-Bradley Electronic Operator Interface >> PanelView ‘e’

39

Page 25: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

40

If you use white boards or paper to circulate production data, you are relying on outdated information.

InView message displays can access real time data through your controller or computer, then broadcast that information to multiple areas and people.

Use InView if

• you want your production data to be timely, visible, accessible to staff, and used frequently

• employees at your facility support or oversee multiple lines

• workers rely on in-person communication for workinstructions or notification of problems

For more information or to download the full"Why do you need InView?" video, visit

www.ab.com/

Page 26: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

41eoi/inview/

IMPROVED

Benefits of using InView

• Communicate real timealarms or production statusplant-wide

• Send instructions to multiplestaff members simultaneously

• Reduce time spent gathering data

• Improve reaction time

response timeutilization of

work forcecommunication

informationawareness

product efficiencies

Page 27: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

Serial RS-485

PLC

PC

Industrial Networks

Ethernet TCP/IP

2242

Alle

n-Br

adle

y El

ectro

nic

Oper

ator

Inte

rface

>>

InVi

ew

InView Network CommunicationsPreferred compatibility to Rockwell Automation logic controllersWith the ability to connect to open industrial protocols like EtherNet /IP, ControlNet, and DeviceNet, plus Remote I/O and DH+,InView™ displays offer Rockwell Automation logic controller users the best interface in the market for message display products.

■ NetLinx Open Network Architecture

• EtherNet/IP• ControlNet• DeviceNet

■ Legacy networks

• DH+• Remote I/O• DH-485

■ Serial

• Serial ASCII Protocol• ActiveX

■ Ethernet TCP/IP

• ActiveX

Reduce start up time by downloading applications over your network.

INVIEW MESSAGE DISPLAYSDelivering the Right Information to the

Right Place at the Right Time

Page 28: PANELVIEW PLUS AND VERSAVIEW CE - … Drive/1250AC-1275AC Top Drive... · PanelView Plus and VersaView CE communicate to all Rockwell ... FactoryTalk Diagnostics ... PanelView Plus

For most up-to-date specification information, visit www.ab.com/eoi/inview/index.html

Allen-Bradley Electronic Operator Interface >> InView

43

InView Message Display Specifications – For catalog number selection, refer to page 68.

2706-P42R, 2706-P42C1

2706-P44R, 2706-P44C2

CatalogNumber

2706-P72CN21

2706-P74CN22

2706-P22R 2706-P92C1

2706-P94C2

Migrate Your Dataliner Panel Mount Displays to InView P22RIf you use panel mount Dataliner message displays, now is the perfect time to upgrade to InView! Not only do InView P22R displays offer modern and cost-effective LEDtechnology, they also provide all the functionality you came to expect from your

Dataliner displays, such as independent linecontrol of messages and the ability to insertalphanumeric variables. The P22R is a drop-inreplacement for 2-line Dataliners and offers a convenient adapter plate (catalog number 2706-PNR2) for 4-line Dataliners. Upgrade today to take advantage of these P22R benefits.

1 Available as 3 ft (91.44 cm) enclosure2 Available as 6 ft (182.88 cm) enclosure

D I S P L A Y

Display Type LED matrix: Red LED matrix: Red (R) or Tri-Color (C) LED matrix: Tri-Color (C) LED matrix: Tri-Color

Display Size (W x H) 12 x 2 in (30 x 5 cm) 36 x 4.8 in (81.4 x 12.2 cm) 1 36 x 7.2 in (91.4 x 18.3 cm) 1 36 x 9.6 in (91.4 x 24.4 cm)72 x 4.8 in (182 x 12.2 cm) 2 60 x 7.2 in (152.4 x 18.3 cm) 2 72 x 9.6 in (182.9 x 24.4 cm)

Display Array 120 x 7 pixels 120 x 16 or 240 x 16 pixels 120 x 24 or 200 x 24 pixels 120 x 32 or 240 x 32 pixels

Center to Center Pixel 0.1 in 0.3 in 0.3 in 0.3 inSpacing (Pitch) (2.54 mm) (7.62 mm) (7.62 mm) (7.62 mm)

Number of Lines 2 1 or 2 1 to 4 1 to 5

Lines of Text/Character 2 line/0.7 in (17.78 mm)/20 1 line/4.8 in (121.92 mm)/121 or 242 1 line/7.2 in (182.88 mm)/121 or 202 1 line/9.6 in (243.84 mm)/13 or 26 Height/Minimum 2 line/2.1 in (53.34 mm)/201 or 402 2 line/3.0 in (76.2 mm)/201 or 332 2 line/4.5 in(114.3 mm)/13 or 26Characters per Line 3 line/2.1 in (53.34 mm)/201 or 332 3 line/3.0 in (76.2 mm)/13 or 26

4 line/1.5 in (38.1 mm)/241 or 402 4 line/2.1 in (53.34 mm)/20 or 405 line/1.5 in (38.1 mm)/24 or 48

Character Set Standard and Extended ASCII Standard and Extended ASCII Standard and Extended ASCII Standard and Extended ASCII

Approximate Viewing 25 feet (7.6 m) 200 ft (60 m) 350 ft (100 m) 450 ft (137 m)Distance

E L E C T R I C A L & E N V I R O N M E N T A L

Input Voltage 24V dc 120-240V AC; 50/60 Hz 120-240V AC; 50/60 Hz 120-240V AC; 50/60 Hz

Operating Temperature 0 – 55°C (32 – 131°F) 0 – 50°C (32 – 122°F) 0 – 50°C (32 – 122°F) 0 – 50°C (32 – 120°F)

Humidity 5 – 95% noncondensing 5 – 95% noncondensing 5 – 95% noncondensing 5 – 95% noncondensing

Ratings NEMA 4 and 4X (Indoor Use Only) NEMA 12 NEMA 4, 4X NEMA 12/13 (Indoor Use Only)

Certifications UL, CE, C-Tick ETL, CE marked ETL, CE marked UL, CE, C-Tick

Enclosure Approximate 1.87 lbs (.85 kg) 28 lbs (12.7 kg) or 60 lbs (27.2 kg) or 70 lbs (32 kg) orWeight 50 lbs (22.7 kg) 80 lbs (36.3 kg) 140 lbs (64 kg)

Enclosure Dimensions 4.38 x 2.43 x 14.3 in 40.38 x 5.5 x 7.88 in1 42.25 x 6.0 x 13.75 in1 15.9 x 5.25 x 41.19 in 1

(W x D x H) (11 x 6 x 36 cm) (102.57 x 13.97 x 20.0 cm) (107.32 x 15.24 x 34.93 cm) (40 x 13x 105 cm)76.38 x 5.5 x 7.88 in2 66.25 x 6.0 x 13.75 in 2 15.9 x 5.25 x 77.2 2

(194.0 x 13.97 x 20.0 cm) (168.28 x 15.24 x 34.93 cm) (14 x 13 x 196 cm)

C O M M U N I C A T I O N S (S E E C ATA L O G N U M B E R S E C T I O N F O R C O M M U N I C AT I O N M O D U L E C ATA L O G N U M B E R S)

Networks Remote I/O, DH-485, DH Plus, DeviceNet, ControlNet, Ethernet

Mounting DIN rail Back-mounted Internal Internal

Power Source External 24 V From Display From Display From Display

Series A or later C or later C or later C or later