Techno Connect 2015 - Rittal
description
Transcript of Techno Connect 2015 - Rittal
-
1
Standardised Data centres
Sales presentation
-
Sales presentation
Motivation
Change of paradigm
Rittals Data centre concept
ll
lll
l
Standardised Data Centres
Benefits lV
Summary V
-
Sales presentation
Does every data centre really have to be unique?
3
Standardised Data Centre Motivation
-
Sales presentation
Data Centre EC1020
Humboldt University 1965
Data Centre Google
Douglas County
Data Centre TR440
University Wrzburg 1979
Data Centre 1&1
Lenexa/Kansas (40.000 Server)
4
Standardised Data Centre Motivation
50 years of customised, client-specific Data centres
-
Sales presentation
5
Standardised Data Centre Motivation
Data Center usually have a homogeneous, modular structure
-
Sales presentation
Motivation
Change of paradigm
Rittals Data centre concept
ll
lll
l
Standardised Data Centre
Benefits lV
Summary V
-
Sales presentation
Data centre construction
Component-based Data Center module-based
Customised Data Centre Tailored Data Center solutions
Standardised Data Centre Pre-defined Data Centre modules
Individual Data centre
construction
Standardized Data centre
construction
9
Standardised Data Centre Change of paradigm
-
Sales presentation
Motivation
Change of paradigm
Rittals Data centre concept
ll
lll
l
Standardised Data Centre
Benefits lV
Summary V
-
Sales presentation Sales presentation 11
RiMatrix S Paradigmenwechsel
The new RiMatrix S. The revolutionary alternative to customised Data Centre construction.
Standardised products available off the shelf.
11 Sales presentation
Standardised Data Centre Rittals Data centre concept
-
Sales presentation
Individual products: LCP, UPS Tailored data centre planning
Every Data Center is unique
Pay as you grow Client-specific solutions Custom configurations Product-specific service
Latest technology
Pre-defined Data Centre modules Standardised Data Centre
planning
All Data centres have the same
structure
ROI can be calculated Simplified administration Simplified service Short delivery and launchtime
The Data Centre is a standardised product
12
Standardised Data Centre Rittals Data centre concept
RiMatrix RiMatrix S
-
13
RiMatrix S Technology Mechanics What does this involve: using the Single6 as an example?
Dimensions: L x W x H 7,000 x 2,750 x 2,710 mm = 19.25 m
Electrical performance: 60 kW redundant
Three shells:
Standard room
Standard security room
Standard container
Usable U: 294
Cooling output: 60 kW redundant
Separate climate areas:
IT area
Technical area
Ready-for-connection
Integrated partitions
Pre-configured
19" rack system
Climate control
technology
Power
technology/UPS Power distribution
Monitoring
Fire
detection/fire
extinguishing
Cold aisle
containment Base system Cable duct
system
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Double versions
Single versions
14
RiMatrix S Technology Mechanics Base configuration and most important variants
Single 6, 60 kW n+1
Double 9, 180 kW n+1
Single 9, 90 kW n+1
Double 6, 120 kW n+1
Internal dimensions L x W x H
7,000 x 2,750 x 2,710 mm
Internal dimensions L x W x H
7,000 x 4,776 x 2,710 mm
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Sales presentation
RiMatrix S (Module Single 6)
Space-saving climatization in the raised-floor
Two separate microclimate zones for IT and technology
Consistent separation of cold air intake and warmer exhaust air
Cable routes at the top
6 server racks, 1 network rack
UPS, battery rack and distribution enclosure
At double 6, the second module is a mirror image
15
Standardised Data Centre Rittals Data centre concept
-
Sales presentation
RiMatrix S (Module Single 9)
When using a central UPS
One microclimate zone for the server area
Aisle containment
Raised floor
Climate control in the raised floor
Cable routes at the top
8 server racks, 1 server-/ network rack
Distribution enclosure
At Double 9, the second module is a mirror image
16
Standardised Data Centre Rittals Data centre concept
-
Sales presentation
Consistent arrangement of all cooling components in the Zero-U-
Space of the Data centre the raised floor
Optimum air routing with minimum deflections
All components are arranged uncompromisingly according to
physical principles at the optimum
position in the cooling circuit of the
data centre around the heart the server
17
Standardised Data Centre Rittals Data centre concept
RiMatrix S
-
18
RiMatrix S Technology Mechanics
Standard raised floor system
Base system
Height: 510 mm Modular dimensions: 600 x 600 mm Supporting load: 6 kN
ZUCS in raised floor Half rack assembly
Same raised floor in Standard Room, Standard Security Room and Container
Raised floor layout Side view
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
19
RiMatrix S Technology Mechanics
Raised floor
Base system
Normal raised floor plates
Grating
cold aisle
with fan
Warm aisle
grating
Ventilation duct for
air/water heat
exchanger
(ZUCS)
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
ZUCS in RiMatrix S
Pipework
20
RiMatrix S Technology Climate control Internal/external principle
Cold water supply
Exterior:
cooling container
or
provided on site
(existing or supplied)
Climate control
technology
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
21
Air-cooled
chiller 70 kW
Free cooler 70kW Hydraulic
station
RiMatrix S Technology Climate control Cooling container (70 kW, 100 kW) Climate control
technology
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Integrated switchgear /
pump station
Switchgear
and
control
RiMatrix S service
commitment
22
RiMatrix S Technology Climate control Cooling container (70 kW, 100 kW) Climate control
technology
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Main components
Prototype pictures
Free cooler Chiller Switchgear Pump station
23
RiMatrix S Technology Climate control Cooling container (70 kW, 100 kW) Climate control
technology
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
24
Network enclosure,
1 x PDU phase A +
1 x PDU phase B
Server enclosures, each 1 x PDU
phase A + 1 x PDU phase B
UPS + battery
enclosure
Power distribution
enclosure
Main power supply
provided by the customer
RiMatrix S Technology Power distribution principle
Power
distribution
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
PDU 7955.132: 24x C13 + 6x C19, 3-phased, 16 A
25
RiMatrix S Technology Power distribution principle
Power
distribution
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Additional monitoring and measurement option
26
RiMatrix S Technology Option: Efficiency package Monitoring
The efficiency package extends the monitoring and management functions of the RiMatrix S
More components with measuring functions:
Metered PDU
Universal power measurement system
DCIM Software RiZone
The connection of third-party components is carried out via RiZone
The characteristics for automation are defined:
Workflow-editor, alarm management, reports
Connection to IT or building service management /
industrial management systems
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Measurement points
27
RiMatrix S Technology Option: Efficiency package Monitoring
Server out
temperatures
[C]
Infrastructure
load [kW]
Total load [kW]
IT load [kW]
Server in
temperatures
[C]
Fan speed [%]
Flow rate
[l/min]
Water in
temperature
[C]
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
RiMatrix S Technology Security Shells
28
Protection
classes Standard room
Standard security
room Standard container
Fire protection - EI 90 / F90 EI 30
Shock test - 3.000 Nm energy after
30 minutes inflame -
Water and dust-
tightness - IP 56 IP 55
Acrid gas-tightness - Yes, based on EN
1634-3 -
Vandalism /
resistance class - WK II RC II
EMC - Basic EMC protection Basic EMC protection
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Sales presentation
RiMatrix S
The Data Centre modules have a complete, measured and TUV-confirmed data sheet
Guaranteed partial PUE when using the Rittal cooling and control Partial PUE 1.09.. 1.2 achieved with aid of:
Water inlet: 20 C
Server intake air: 26 C
Fan speed: < 61 %
Delta T (air side):
-
Additional monitoring and measurement option
30
RiMatrix S Technology Option: Efficiency package Monitoring
The efficiency package extends the monitoring and management functions of the RiMatrix S
More components with measuring functions:
Metered PDU
Universal power measurement system
DCIM Software RiZone
The connection of third-party components is carried out via RiZone
The characteristics for automation are defined:
Workflow-editor, alarm management, reports
Connection to IT or building service management /
industrial management systems
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Measurement points
31
RiMatrix S Technology Option: Efficiency package Monitoring
Server out
temperatures
[C]
Infrastructure
load [kW]
Total load [kW]
IT load [kW]
Server in
temperatures
[C]
Fan speed [%]
Flow rate
[l/min]
Water in
temperature
[C]
PM-IT / RiMatrix S Expert Training - Technology / 06-
2014
-
Sales presentation
RiMatrix S
All RiMatrix S modules may be scaled to almost any output
between 20 and 450 kW
The Container solution is limited to scaling with the Single 6 and Single
9 modules, due to the spacial
conditions inside the containers.
32
Standardised Data Centre Rittals Data centre concept
-
Sales presentation
RiMatrix S
One solution for existing property, security room and container
33
Standardised Data Centre Rittals Data centre concept
-
Sales presentation
One item number for RiMatrix S in existing
properties.
Single 6
Double 6
Single 9
Double 9
34
Standardised Data Centre Rittals Data centre concept
RiMatrix S
-
Sales presentation
RiMatrix S
One item number for RiMatrix S in security rooms
and containers.
Single 6
Double 6
Single 9
Double 9
35
Standardised Data Centre Rittals Data centre concept
-
Sales presentation
RiMatrix S
Flexibility with optional packages
A few intelligent optional packages ensure the flexibilty at customer projects:
Efficiency package RiZone (Data Centre Infrastructure Management Software), PDU (Power Distribution Unit), UMG (universal measuring
device) in ISV (distribution enclosure)
Redundant infeed for extend to TIER III for TV-certification
VESDA extinguishing system
Humidification and dehumidification for container-based version using in critical climate zones
36
Standardised Data Centre Rittals Data centre concept
-
Sales presentation
Motivation
Change of paradigm
Rittals Data centre concept
ll
lll
l
Standardised Data Center
Benefits lV
Summary V
-
Sales presentation
What are the buying factors?
Costs Time
Quality Service
Client
38
Standardised Data Center Benefits
-
Sales presentation
Cost benefits
Significantly simplified, shortened planning phase
Lower planning and implementation phase investments
Lower operating costs
Lower personnel costs
Simplified service- and administration processes
39
Standardised Data Center Benefits
-
Sales presentation
Time benefits
Shortened planning time
Very short delivery time
Quick to go-live
Hotline
Service response time
40
Standardised Data Center Benefits
-
Sales presentation
Quality benefits
Solution based on proven standard products
Fully documented
Certificates and approvals
Testing and acceptance tests
System tests
41
Standardised Data Center Benefits
-
Sales presentation
Service benefits
Professional advice in quotation phase
Support during configuration, design and integration
Project manager/build manger during installation/going live
Service/fast response times/quick build times/availability of replacement parts
42
Standardised Data Center Benefits
-
Sales presentation
RiMatrix S service commitment
Product Process
With a turnkey solution, the client also expects turnkey processes throughout the
project!
43
Standardised Data Center Benefits
-
Sales presentation
Motivation
Change of paradigm
Rittals Data centre concept
ll
lll
l
Standardised Data Center
Benefits lV
Summary V
-
Sales presentation
The facts at a glance
Data centres can be built from standardised modules
This applies for container and security rooms, but also for existing property (buildings)
The Data centre is a product with one item number
The Data centre has a data sheet, The PUE and power consumption are predictable
Complete ROI calculation can be made in the planning
All processes are simplified, so that the data centre is delivered and commissioned in next to no time
45
Standardised Data Center Summary
-
Sales presentation
IT goes IE
RiMatrix S reference
RiMatrix S Wollschlger Group buys off-the-peg data centre
The Wollschlger Group, one of Germany's leading commercial enterprises
in the precision tools business.
Customer-Feedback :
To avoid long planning phases, we rely on the new concept for the standardised Rittal data centre construction, says Stefan Wrder, Head of IT and Project Management at Wollschlger. We were impressed by the functions of RiMatrix S and found that it was exactly the right solution for Wollschlger. It completely fulfilled our requirements for both energy efficiency and high availability, as well as for our future expansion opportunities.
46
-