    Standardised Data centres

    Sales presentation

  • Sales presentation

    Motivation

    Change of paradigm

    Rittals Data centre concept

    ll

    lll

    l

    Standardised Data Centres

    Benefits lV

    Summary V

  • Sales presentation

    Does every data centre really have to be unique?

    3

    Standardised Data Centre Motivation

  • Sales presentation

    Data Centre EC1020

    Humboldt University 1965

    Data Centre Google

    Douglas County

    Data Centre TR440

    University Wrzburg 1979

    Data Centre 1&1

    Lenexa/Kansas (40.000 Server)

    4

    Standardised Data Centre Motivation

    50 years of customised, client-specific Data centres

  • Sales presentation

    5

    Standardised Data Centre Motivation

    Data Center usually have a homogeneous, modular structure

  • Sales presentation

    Motivation

    Change of paradigm

    Rittals Data centre concept

    ll

    lll

    l

    Standardised Data Centre

    Benefits lV

    Summary V

  • Sales presentation

    Data centre construction

    Component-based Data Center module-based

    Customised Data Centre Tailored Data Center solutions

    Standardised Data Centre Pre-defined Data Centre modules

    Individual Data centre

    construction

    Standardized Data centre

    construction

    9

    Standardised Data Centre Change of paradigm

  • Sales presentation

    Motivation

    Change of paradigm

    Rittals Data centre concept

    ll

    lll

    l

    Standardised Data Centre

    Benefits lV

    Summary V

  • Sales presentation Sales presentation 11

    RiMatrix S Paradigmenwechsel

    The new RiMatrix S. The revolutionary alternative to customised Data Centre construction.

    Standardised products available off the shelf.

    11 Sales presentation

    Standardised Data Centre Rittals Data centre concept

  • Sales presentation

    Individual products: LCP, UPS Tailored data centre planning

    Every Data Center is unique

    Pay as you grow Client-specific solutions Custom configurations Product-specific service

    Latest technology

    Pre-defined Data Centre modules Standardised Data Centre

    planning

    All Data centres have the same

    structure

    ROI can be calculated Simplified administration Simplified service Short delivery and launchtime

    The Data Centre is a standardised product

    12

    Standardised Data Centre Rittals Data centre concept

    RiMatrix RiMatrix S

  • 13

    RiMatrix S Technology Mechanics What does this involve: using the Single6 as an example?

    Dimensions: L x W x H 7,000 x 2,750 x 2,710 mm = 19.25 m

    Electrical performance: 60 kW redundant

    Three shells:

    Standard room

    Standard security room

    Standard container

    Usable U: 294

    Cooling output: 60 kW redundant

    Separate climate areas:

    IT area

    Technical area

    Ready-for-connection

    Integrated partitions

    Pre-configured

    19" rack system

    Climate control

    technology

    Power

    technology/UPS Power distribution

    Monitoring

    Fire

    detection/fire

    extinguishing

    Cold aisle

    containment Base system Cable duct

    system

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Double versions

    Single versions

    14

    RiMatrix S Technology Mechanics Base configuration and most important variants

    Single 6, 60 kW n+1

    Double 9, 180 kW n+1

    Single 9, 90 kW n+1

    Double 6, 120 kW n+1

    Internal dimensions L x W x H

    7,000 x 2,750 x 2,710 mm

    Internal dimensions L x W x H

    7,000 x 4,776 x 2,710 mm

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Sales presentation

    RiMatrix S (Module Single 6)

    Space-saving climatization in the raised-floor

    Two separate microclimate zones for IT and technology

    Consistent separation of cold air intake and warmer exhaust air

    Cable routes at the top

    6 server racks, 1 network rack

    UPS, battery rack and distribution enclosure

    At double 6, the second module is a mirror image

    15

    Standardised Data Centre Rittals Data centre concept

  • Sales presentation

    RiMatrix S (Module Single 9)

    When using a central UPS

    One microclimate zone for the server area

    Aisle containment

    Raised floor

    Climate control in the raised floor

    Cable routes at the top

    8 server racks, 1 server-/ network rack

    Distribution enclosure

    At Double 9, the second module is a mirror image

    16

    Standardised Data Centre Rittals Data centre concept

  • Sales presentation

    Consistent arrangement of all cooling components in the Zero-U-

    Space of the Data centre the raised floor

    Optimum air routing with minimum deflections

    All components are arranged uncompromisingly according to

    physical principles at the optimum

    position in the cooling circuit of the

    data centre around the heart the server

    17

    Standardised Data Centre Rittals Data centre concept

    RiMatrix S

  • 18

    RiMatrix S Technology Mechanics

    Standard raised floor system

    Base system

    Height: 510 mm Modular dimensions: 600 x 600 mm Supporting load: 6 kN

    ZUCS in raised floor Half rack assembly

    Same raised floor in Standard Room, Standard Security Room and Container

    Raised floor layout Side view

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • 19

    RiMatrix S Technology Mechanics

    Raised floor

    Base system

    Normal raised floor plates

    Grating

    cold aisle

    with fan

    Warm aisle

    grating

    Ventilation duct for

    air/water heat

    exchanger

    (ZUCS)

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • ZUCS in RiMatrix S

    Pipework

    20

    RiMatrix S Technology Climate control Internal/external principle

    Cold water supply

    Exterior:

    cooling container

    or

    provided on site

    (existing or supplied)

    Climate control

    technology

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • 21

    Air-cooled

    chiller 70 kW

    Free cooler 70kW Hydraulic

    station

    RiMatrix S Technology Climate control Cooling container (70 kW, 100 kW) Climate control

    technology

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Integrated switchgear /

    pump station

    Switchgear

    and

    control

    RiMatrix S service

    commitment

    22

    RiMatrix S Technology Climate control Cooling container (70 kW, 100 kW) Climate control

    technology

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Main components

    Prototype pictures

    Free cooler Chiller Switchgear Pump station

    23

    RiMatrix S Technology Climate control Cooling container (70 kW, 100 kW) Climate control

    technology

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • 24

    Network enclosure,

    1 x PDU phase A +

    1 x PDU phase B

    Server enclosures, each 1 x PDU

    phase A + 1 x PDU phase B

    UPS + battery

    enclosure

    Power distribution

    enclosure

    Main power supply

    provided by the customer

    RiMatrix S Technology Power distribution principle

    Power

    distribution

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • PDU 7955.132: 24x C13 + 6x C19, 3-phased, 16 A

    25

    RiMatrix S Technology Power distribution principle

    Power

    distribution

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Additional monitoring and measurement option

    26

    RiMatrix S Technology Option: Efficiency package Monitoring

    The efficiency package extends the monitoring and management functions of the RiMatrix S

    More components with measuring functions:

    Metered PDU

    Universal power measurement system

    DCIM Software RiZone

    The connection of third-party components is carried out via RiZone

    The characteristics for automation are defined:

    Workflow-editor, alarm management, reports

    Connection to IT or building service management /

    industrial management systems

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Measurement points

    27

    RiMatrix S Technology Option: Efficiency package Monitoring

    Server out

    temperatures

    [C]

    Infrastructure

    load [kW]

    Total load [kW]

    IT load [kW]

    Server in

    temperatures

    [C]

    Fan speed [%]

    Flow rate

    [l/min]

    Water in

    temperature

    [C]

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • RiMatrix S Technology Security Shells

    28

    Protection

    classes Standard room

    Standard security

    room Standard container

    Fire protection - EI 90 / F90 EI 30

    Shock test - 3.000 Nm energy after

    30 minutes inflame -

    Water and dust-

    tightness - IP 56 IP 55

    Acrid gas-tightness - Yes, based on EN

    1634-3 -

    Vandalism /

    resistance class - WK II RC II

    EMC - Basic EMC protection Basic EMC protection

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Sales presentation

    RiMatrix S

    The Data Centre modules have a complete, measured and TUV-confirmed data sheet

    Guaranteed partial PUE when using the Rittal cooling and control Partial PUE 1.09.. 1.2 achieved with aid of:

    Water inlet: 20 C

    Server intake air: 26 C

    Fan speed: < 61 %

    Delta T (air side):

  • Additional monitoring and measurement option

    30

    RiMatrix S Technology Option: Efficiency package Monitoring

    The efficiency package extends the monitoring and management functions of the RiMatrix S

    More components with measuring functions:

    Metered PDU

    Universal power measurement system

    DCIM Software RiZone

    The connection of third-party components is carried out via RiZone

    The characteristics for automation are defined:

    Workflow-editor, alarm management, reports

    Connection to IT or building service management /

    industrial management systems

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Measurement points

    31

    RiMatrix S Technology Option: Efficiency package Monitoring

    Server out

    temperatures

    [C]

    Infrastructure

    load [kW]

    Total load [kW]

    IT load [kW]

    Server in

    temperatures

    [C]

    Fan speed [%]

    Flow rate

    [l/min]

    Water in

    temperature

    [C]

    PM-IT / RiMatrix S Expert Training - Technology / 06-

    2014

  • Sales presentation

    RiMatrix S

    All RiMatrix S modules may be scaled to almost any output

    between 20 and 450 kW

    The Container solution is limited to scaling with the Single 6 and Single

    9 modules, due to the spacial

    conditions inside the containers.

    32

    Standardised Data Centre Rittals Data centre concept

  • Sales presentation

    RiMatrix S

    One solution for existing property, security room and container

    33

    Standardised Data Centre Rittals Data centre concept

  • Sales presentation

    One item number for RiMatrix S in existing

    properties.

    Single 6

    Double 6

    Single 9

    Double 9

    34

    Standardised Data Centre Rittals Data centre concept

    RiMatrix S

  • Sales presentation

    RiMatrix S

    One item number for RiMatrix S in security rooms

    and containers.

    Single 6

    Double 6

    Single 9

    Double 9

    35

    Standardised Data Centre Rittals Data centre concept

  • Sales presentation

    RiMatrix S

    Flexibility with optional packages

    A few intelligent optional packages ensure the flexibilty at customer projects:

    Efficiency package RiZone (Data Centre Infrastructure Management Software), PDU (Power Distribution Unit), UMG (universal measuring

    device) in ISV (distribution enclosure)

    Redundant infeed for extend to TIER III for TV-certification

    VESDA extinguishing system

    Humidification and dehumidification for container-based version using in critical climate zones

    36

    Standardised Data Centre Rittals Data centre concept

  • Sales presentation

    Motivation

    Change of paradigm

    Rittals Data centre concept

    ll

    lll

    l

    Standardised Data Center

    Benefits lV

    Summary V

  • Sales presentation

    What are the buying factors?

    Costs Time

    Quality Service

    Client

    38

    Standardised Data Center Benefits

  • Sales presentation

    Cost benefits

    Significantly simplified, shortened planning phase

    Lower planning and implementation phase investments

    Lower operating costs

    Lower personnel costs

    Simplified service- and administration processes

    39

    Standardised Data Center Benefits

  • Sales presentation

    Time benefits

    Shortened planning time

    Very short delivery time

    Quick to go-live

    Hotline

    Service response time

    40

    Standardised Data Center Benefits

  • Sales presentation

    Quality benefits

    Solution based on proven standard products

    Fully documented

    Certificates and approvals

    Testing and acceptance tests

    System tests

    41

    Standardised Data Center Benefits

  • Sales presentation

    Service benefits

    Professional advice in quotation phase

    Support during configuration, design and integration

    Project manager/build manger during installation/going live

    Service/fast response times/quick build times/availability of replacement parts

    42

    Standardised Data Center Benefits

  • Sales presentation

    RiMatrix S service commitment

    Product Process

    With a turnkey solution, the client also expects turnkey processes throughout the

    project!

    43

    Standardised Data Center Benefits

  • Sales presentation

    Motivation

    Change of paradigm

    Rittals Data centre concept

    ll

    lll

    l

    Standardised Data Center

    Benefits lV

    Summary V

  • Sales presentation

    The facts at a glance

    Data centres can be built from standardised modules

    This applies for container and security rooms, but also for existing property (buildings)

    The Data centre is a product with one item number

    The Data centre has a data sheet, The PUE and power consumption are predictable

    Complete ROI calculation can be made in the planning

    All processes are simplified, so that the data centre is delivered and commissioned in next to no time

    45

    Standardised Data Center Summary

  • Sales presentation

    IT goes IE

    RiMatrix S reference

    RiMatrix S Wollschlger Group buys off-the-peg data centre

    The Wollschlger Group, one of Germany's leading commercial enterprises

    in the precision tools business.

    Customer-Feedback :

    To avoid long planning phases, we rely on the new concept for the standardised Rittal data centre construction, says Stefan Wrder, Head of IT and Project Management at Wollschlger. We were impressed by the functions of RiMatrix S and found that it was exactly the right solution for Wollschlger. It completely fulfilled our requirements for both energy efficiency and high availability, as well as for our future expansion opportunities.

    46