Case Studies of RVRS design; Use of Light Weight Panelized Construction in
Multiple Projects OBEC
March 2016 Blair Davies, P.Eng
VP GM Engineered Assemblies
- March 9, 2016 page 1
![Page 2: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/2.jpg)
Engineered Assemblies “Unite the House of Design with The Field of Construction”
– Thermally Broken RVRS Facades – Daylighting
– High performance Metal Roofs Partners
» Etex - Imetco » Composites Gurea - SRP Canada » Formica - AWF » Gentas - CPI Daylighting
>1000 projects; no warranty claims, no non payment for non performance
Sister company Praxy installation Ontario
- March 9, 2016 page 2
![Page 3: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/3.jpg)
Speaker Blair Davies, P.Eng
– BaSc University of Waterloo – Civil Engineering – MBA Schulich School of Business – Building envelope business since 2008 – Buildings across Canada
- March 9, 2016 page 3
![Page 4: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/4.jpg)
Agen
da
• Introduction – does all this matter? • What matters • Definition and history
– DIN 18516 – British Standards
• Pressure Equalization – the debate • Case Study #1
– Parliament St Data Centre – ceramic • Case Study #2
– McLean Park Towers – fibre cement • Case Study #3
– 88 Sheppard, Minto – fibre cement • Case Study #4
– 2 Virtue Street – fibre cement recladding • Case Study # 5
– Addington Residence – ceramic recladding • Unanswered questions • Conclusion • Ontario Building Code • Discussion
- March 9, 2016 page 4
![Page 5: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/5.jpg)
Is all this necessary?
- March 9, 2016 page 5
![Page 6: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/6.jpg)
What matters • Ventilation • Drainage • Thermal Bridging • Secure • Impact • Weight • Durable • Constructible • Climate and weather • Acoustics
- March 9, 2016 page 6
![Page 7: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/7.jpg)
Light weight matter?
• Fibre cement 15 kg/m2 • Ceramic 35 – 50 kg/m2 • Metal 4.5-7.3 kg/m2
• Steel stud wall; insulation; thermally broken substructure 20kg/m2 (GUESS)
• Brick 174 kg/m2
• Precast (300mm) 718 kg/m2 • EIFS (100mm) 8 kg/m2 • Curtain wall 49 kg/m2
- March 9, 2016 page 7
![Page 8: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/8.jpg)
Define RVRS
• Cladding stands off the moisture resistant surface to create a drainage plane and ventilation cavity.
• Vertical cavity for stack effect and capillary break. • The wall open top and bottom to allow ventilation, • Intermediate gaps open or closed; aesthetic decision. • Insulated or non-insulated.
- March 9, 2016 page 8
Source: Wikipedia
![Page 9: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/9.jpg)
- March 9, 2016 page 9
• Framing – stud, concrete, brick, etc
• Sheathing, AVB • Insulation • Weather barrier • Cavity • Panels
• Thermally Broken substructure
![Page 10: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/10.jpg)
- March 9, 2016 page 10
Detail in practice
![Page 11: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/11.jpg)
11
Key Attributes of RVRS Facades?
• Remove water and vapour in active, natural manner from assembly • Exterior takes abuse of the weather - full heat, the sun, the wind… • Ventilation helps the building AND the façade product • Accommodates any amount of insulation • Insulation is always drying - better effective R • Simpler, more easily built and inspected - no caulking • Lighter thinner systems than concrete and brick • Unlimited choice in panel selection. • Better energy efficiency than most curtain wall • Less expensive than many other systems
![Page 12: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/12.jpg)
History and Standards • Ventilated façade in Europe
– DIN 18516 – German Construction Standard • Specifies all key attributes • Spacing behind panel minimum 20mm
– CWCT H92 – NBS British Construction Standard
• Canadian Construction Technology Update – 1963 NRC – 1999 CTU – Cladding leakage area to Ventilation area suggested 10:1
• USA NIBS
- March 9, 2016 page 12
![Page 13: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/13.jpg)
DIN 18516
• Covers – Scope and field of application – Concepts – Requirements – Design loads, thermal effects and structural movements – Structural analysis – Protection of materials – Testing of connectors, fixing and ties – Documentation – Inspection
- March 9, 2016 page 13
![Page 14: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/14.jpg)
NBS Section H92
• Vertical building envelope; Outer skin • Airtight insulated backing wall, separate by ventilated cavity • Key distinction is that curtain walling is usually the whole
envelope, while rainscreen cladding is the outer protective layer of the envelope.
- March 9, 2016 page 14
![Page 15: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/15.jpg)
Business Opportunity • Materials developed to leverage RVRS mostly from Europe
– High density fibre cement – Glass reinforced concrete – Phenolic – Ceramic – Porcelain – Metals – Stone laminates – Wood panels – Hybrids
• Subsystems • Design • Labour
- March 9, 2016 page 15
![Page 16: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/16.jpg)
RVRS suitable for all building types
House Condo Hotel University School Hospital
![Page 17: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/17.jpg)
Alcoa building pittsburgh 1950 1st modern use
![Page 18: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/18.jpg)
Walter Gropius, gropiusstadt, Berlin, b1960-1975
Eternit panels in high rise ventilated facade application
![Page 19: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/19.jpg)
Pressure Equalization • Ideal
• Ambiguous
• Planning ≠ Actual
• Structural considerations
• Not part of European standards
- March 9, 2016 page 19
Sources include: National Building Service UK 1-Jan-2010 “Rainscreen cladding; letting air in to keep rain out”
![Page 20: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/20.jpg)
P.E. - compartmentalization • Horizontal closures so air can get in, but can’t get out • Seeing specifications with compartmentalization • Some study that at façade corners and parapets this helps PE.* • Europeans products do not recognize this practice
- March 9, 2016 page 20
Source: MCA Whitepaper 11/2014 v2 NRC CTU no 17 1998 Graphic by Nichiha
![Page 21: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/21.jpg)
Rain Screen Membrane • Water resistant, water vapour permeable membrane • Secondary drainage plane • Aesthetic black reveal with long term UV resistance
for open joint systems • Can be the deemed air barrier if sealed • Installed directly behind cladding
- March 9, 2016 page 21
![Page 22: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/22.jpg)
Weather Membrane § For Closed Joint Systems (with no long term UV)
• High WVT 150 perms • 120 g/m2 • Drainage Plane • CCMC listed • Air Barrier
Courtesy
![Page 23: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/23.jpg)
Drying Rate MVTR (perms)Comparison
0 20 40 60 80
100 120 140 160
Prod 1 Prod 2 Prod 3 Prod 4
Perms
Perms
Courtesy
![Page 24: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/24.jpg)
![Page 25: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/25.jpg)
Weather membrane UV
§ For Open Joint Wall Systems (long term UV) • Long Term UV Resistance
l DIN EN 13859 (5,000 hours exposure <5% loss) • Drainage Plane • Air Barrier
courtesy
![Page 26: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/26.jpg)
26
![Page 27: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/27.jpg)
27
Installation
Ø Attachment l Over insulation, behind cladding l Clips or system support, screws with plates
Ø Overlapping
l Shingle style with 6 inch overlap
Ø Seams l Tape vertical seams and details l Tape all seams in Air Barrier installations
![Page 28: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/28.jpg)
• Robust • Breathable • Water Resistant • UV Resistant
Why Weather Membrane?
![Page 29: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/29.jpg)
Panels
page 29
Zinc
ACP FRC & GFRC
Phenolic
Porcelain Ceramic
ACP
Stone veneer
Unlimited choice
![Page 30: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/30.jpg)
All conditions have been done
- March 9, 2016 page 30
![Page 31: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/31.jpg)
Case Study 1 Data Centre • Parliament St Data Centre • Cladding, cavity, WB, Insulation, Thermally broken substructure,
AVB, framing. • Effective R Value Goal 21 • Extruded Ceramic (35kg/m2) + Ceramic Baguettes • Cavity dimension = 40mm vertical + 63mm. • Insulation type = Roxul Cavity Rock 4” (100mm) • WB type = SRP Airoutshield • AVB type = Soprema • Special conditions: designed for disaster conditions, so extreme
slab deflections expected • Why: “Relate local masonry in modern way to reflect use of
building” WZMH • Architect WZMH, GC Urbacon, Installer Flynn Canada
- March 9, 2016 page 31
![Page 32: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/32.jpg)
- March 9, 2016 page 32
![Page 33: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/33.jpg)
- March 9, 2016 page 33
![Page 34: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/34.jpg)
- March 9, 2016 page 34
![Page 35: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/35.jpg)
Case Study 2 - McLean Park Towers – Tower Renewal • Social housing, Vancouver • High Density Fibre Cement, vertical girts, WB, thermally
broken substructure, AVB, Concrete • HDFC 14.9 kg/m2 faced fastened with colour matched rivets
• 25mm cavity with vertical galvanized steel girts • Roxul Cavity Rock 4” (100mm) • Thermally broken facade • Vaproshield WB • Soprema AVB • Special conditions:
• JRS Engineering; Installer Marine Cladding
- March 9, 2016 page 35
![Page 36: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/36.jpg)
- March 9, 2016 page 36
![Page 37: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/37.jpg)
Case Study 3 88 Sheppard E, Minto
• HDFC, Vertical girts, cavity, WB, insulation and girts, AVB, Framing or Concrete
• Effective R value not a goal • HDFC 14.9 kg/m2 adhered with Dynamic Bond Adhesive • Cavity dimension 25mm • Roxul semi-rigid rockboard 40 2” and 3” • Roxul curtain rock 5”SRP AirOutShield UV • AVB type TBD
• Rafael + Bigauskas Architects; GC and Owner Minto; Installer Praxy Cladding
- March 9, 2016 page 37
![Page 38: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/38.jpg)
- March 9, 2016 page 38
Details – need direction
![Page 39: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/39.jpg)
- March 9, 2016 page 39
![Page 40: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/40.jpg)
- March 9, 2016 page 40
AVB
WB
![Page 41: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/41.jpg)
Case Study 4
• 2 Virtue Street • HDFC, girts, cavity, breather
membrane over brick • Un-insulated • HDFC 14.9 kg/m2 • Cavity dimension 25mm • SRP AOS UV • AVB poly inside studs
- March 9, 2016 page 41
![Page 42: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/42.jpg)
- March 9, 2016 page 42
Renovation adds new vigour to a sagging Toronto home Aug 2013
![Page 43: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/43.jpg)
Case Study 5 Addington Residence U Guelph • Ceramic panels, system rails, weather
membrane, horizontal girts, sprayfoam insulation on top of brick façade
• Ceramic 35 kg/m2 • Cavity dimension 20mm • Spray foam 4” (100mm) • SRP AOS non UV WB • Blueskin SA behind girts, Spray foam is AVB • Unique: Brick fastened back to block, and cavity
filled. Insulated rainscreen fastened to brick façade
- March 9, 2016 page 43
Larkin Architects; GC Harbridge and Cross; Installer AMNA
![Page 44: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/44.jpg)
- March 9, 2016 page 44
![Page 45: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/45.jpg)
What would it take to make a real case study – anyone? • Instrumentation • Long term study of RH in insulation • Measurement during weather incident
- March 9, 2016 page 45
![Page 46: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/46.jpg)
Construction Best Practices
• 5 things need to be done right to have RVRS success with panelized products eg high density fibre cement. 1. Ventilation top and bottom. 2. Vertical substructure for ventilation. 3. Panels allowed to move for thermal and for building
movement, typically with fixed and floating points. 4. Substructure spacing set by live and dead loads. 5. Reasonably true wall or adjustable substructure
- March 9, 2016 page 46
![Page 47: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/47.jpg)
Unanswered questions
• What happens to wet insulation over long term?
• Why isn’t metal panel / ACP installed as RVRS?
• Why does OBC not cover topic completely?
• Why are product choices in Canada limited?
- March 9, 2016 page 47
![Page 48: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/48.jpg)
Conclusion
• RVRS Façade a significant design choice for aesthetic and envelope performance reasons
• Engineered extensively, mostly in Europe • Business opportunity for Canadians • A few things need to be done right, but reasonable for most
cladding trade companies to learn
• Thankyou.
- March 9, 2016 page 48
![Page 49: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/49.jpg)
OBC Review
• Part 4 Structural – All systems can be designed for all Canadian loads by changing
spacing, gauge and material of substructure. – Seismic testing available for heavier facades eg ceramic. No
call yet for testing of phenolics, fibre cement, metal panel – Panels themselves designed to pass live loads back to
substructure, not provide any structural role to the building. • Part 5
– 5.1.4.2 Resistance to Deterioration – CSA S478 Durability of Buildings – 5.2.2.1 Determination of Structural loads – comply – 5.3.1 Thermal resistance – not the panels, just the insulation
layer. Expectation is cavity has higher or lower temp than outside, improving energy usage – needs proving.
• Important to design due point in right place between AVB and Weather membrane
• Penetration detailing essential – thermal bridging and air transfer to be eliminated
– 5.4.1 Air Barrier – at least two layers of protection, insulation may offer another or replace a barrier.
- March 9, 2016 page 49
![Page 50: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/50.jpg)
OBC • 5.4.1.2 Air Barriers CAN/ULCS741 • 5.5.1.1 (1) assemblies shall be such that they control vapour
diffusion or permit venting to the exterior so as to minimize accumulation of condensation in the building component or assembly.
• 5.6.1 Protection from Precipitation – Except as provided in Sentence (2), where a building
component or assembly is exposed to precipitation, the component or assembly shall,
• (a) minimize ingress of precipitation into the component or assembly, and
• (b) prevent ingress of precipitation into interior space. – (2) Protection from ingress of precipitation is not required
where it can be shown that such ingress will not adversely affect any of ….
• 5.6.2 Sealing and drainage – reads like sealing is good. May have misguided intentions.
- March 9, 2016 page 50
![Page 51: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/51.jpg)
OBC • Part 9 is different – 9.20.13. Control of Rain Water Penetration – 9.25.3. Air Barrier Systems – 9.25.4. Vapour Barriers – 9.25.5. Properties and Position of Materials in Building
Envelope – 9.27. Cladding TBD
- March 9, 2016 page 51
![Page 52: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/52.jpg)
Rear Ventilated Rain Screen (Moisture Management)
Drainage and ventilation
Some water gets in, and then
drains out. Condensation
and water vapour vented to
exterior.
![Page 53: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/53.jpg)
Alternatively – Single Skin Construction. Water always gets in causing deterioration
Crack
![Page 54: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/54.jpg)
Drained cavity Rainscreen eg Masonry
• Masonry uses Rainscreen term – different than RVRS
• Drainage of water that penetrates the brick is allowed to drain out
• Limited to no ventilation; closed top and bottom of wall.
• Less active plenum; reducing benefit of ventilation
• Constructability issues with ensuring drainage is working
• Heavier, more steps to build
- March 9, 2016 page 54
![Page 55: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/55.jpg)
RVRS (Insulation)
NATURAL INSULATION – 0.5 R Value from RVRS Energy Efficiency Consumption of AC/Heating Acoustic Insulation
![Page 56: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/56.jpg)
RVRS (Temperature Regulation)
When the outside temperature is HOT, the ventilated rain screen cladding has a cooling effect on the building
• Most of the sun’s rays are reflected • Ventilating effect of the air gap
![Page 57: Rear Ventilated Rain Screen OBEC Mar 2016](https://reader031.fdocuments.in/reader031/viewer/2022021918/589a9bcd1a28abfc1a8b488b/html5/thumbnails/57.jpg)
RVRS (Temperature Regulation)
When the temperature is COLD outside the same process occurs: • Most of the cold air is
reflected by the exterior architectural panel • The remaining cool air will
partially dissipate by the ventilating effect of the air gap between the architectural panel and the structural wall
• Insulation is protected, so will remain effective