QRC Substrate Technology Characterization Manual.pdf

download QRC Substrate Technology Characterization Manual.pdf

of 118

Transcript of QRC Substrate Technology Characterization Manual.pdf

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    1/118

    QRC Substrate Technology

    Characterization ManualProduct Version 10.1.2 HF1

    July 2011

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    2/118

    20072011 Cadence Design Systems, Inc. All rights reserved.

    Cadence Design Systems, Inc. (Cadence), 2655 Seely Ave., San Jose, CA 95134, USA.

    Trademarks: Trademarks and service marks of Cadence Design Systems, Inc. contained in this documentare attributed to Cadence with the appropriate symbol. For queries regarding Cadences trademarks,

    contact the corporate legal department at the address shown above or call 800.862.4522.

    Restricted Permission:This publication is protected by copyright law and international treaties andcontains trade secrets and proprietary information owned by Cadence. Unauthorized reproduction ordistribution of this publication, or any portion of it, may result in civil and criminal penalties. Except as

    specified in this permission statement, this publication may not be copied, reproduced, modified, published,uploaded, posted, transmitted, or distributed in any way, without prior written permission from Cadence.Unless otherwise agreed to by Cadence in writing, this statement grants Cadence customers permission to

    print one (1) hard copy of this publication subject to the following conditions:

    1. The publication may be used only in accordance with a written agreement between Cadence and its

    customer.

    2. The publication may not be modified in any way.

    3. Any authorized copy of the publication or portion thereof must include all original copyright,trademark, and other proprietary notices and this permission statement.

    4. The information contained in this document cannot be used in the development of like products orsoftware, whether for internal or external use, and shall not be used for the benefit of any other party,

    whether or not for consideration.

    Disclaimer: Information in this publication is subject to change without notice and does not represent a

    commitment on the part of Cadence. Except as may be explicitly set forth in such agreement, Cadence doesnot make, and expressly disclaims, any representations or warranties as to the completeness, accuracy or

    usefulness of the information contained in this document. Cadence does not warrant that use of suchinformation will not infringe any third par ty rights, nor does Cadence assume any liability for damages orcosts of any kind that may result from use of such information.

    Restricted Rights:Use, duplication, or disclosure by the Government is subject to restrictions as set forthin FAR52.227-14 and DFAR252.227-7013 et seq. or its successor

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    3/118

    QRC Substrate Technology Characterization Manual

    July 2011 3 Product Version 10.1.2 HF1

    Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9About This Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    Operating System Versions and Patches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    Syntactical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    1

    Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    Substrate Characterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    Substrate Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    Technology Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Three-Dimensional Modeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Vertical Mesh Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    Regions and Cross-Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    Design Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    Graphical User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    2

    Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Starting QRC TCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    QRC TCT Main Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    File Selection Dialog Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    Exiting QRC TCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    3

    How to Use QRC TCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Starting a Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    Contents

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    4/118

    QRC Substrate Technology Characterization Manual

    July 2011 4 Product Version 10.1.2 HF1

    Creating a New Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    Loading an Existing Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    Reverting to a Saved Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    Controlling the Screen Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Zooming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    Panning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    Controlling Grid Visibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    Loading the Doping Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Specifying the Profile Default Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Changing the Scale of the Ordinate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Controlling Doping Concentration Profile Visibility . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    Controlling Legend Visibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    Specifying Regions, Cross-Sections, and Interface Layers . . . . . . . . . . . . . . . . . . . . . . . 31Specifying Region Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Specifying Cross-Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    Specifying Interconnect Layer Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    Specifying the Gate Layer Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    Attaching Doping Profiles to Regions/Cross-Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    Attaching Doping Profiles to the Default/Default Combination . . . . . . . . . . . . . . . . . . 39

    Changing the Doping Profile Display Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

    Discretizing the Substrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

    Changing the Discretization Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Starting a Discretization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

    Changing a Discretization Manually . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

    Changing Region Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

    Changing the Junction Parameters of a Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

    Calculating Junction Capacitance for Two-Dimensional Doping Profiles . . . . . . . . . . 49

    Setting Interface Parameters for Interconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

    Setting Interface Parameters for Gates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

    Setting Interface Parameters for Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

    Creating the Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Saving a Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

    Exporting a Template File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

    Saving the Technology Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    5/118

    QRC Substrate Technology Characterization Manual

    July 2011 5 Product Version 10.1.2 HF1

    4

    Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

    Session Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57New Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

    Load Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

    Save Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

    Revert to Saved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

    Export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

    Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

    Options Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

    Default Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

    Discretization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60View Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

    Y-Axis Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

    Zoom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

    Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

    Subdivisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

    Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

    Regions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

    Edit Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

    Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Regions Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

    Interface Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

    Subdivision Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

    Discretization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

    Move . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

    Add . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

    Delete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

    Undo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

    Redo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Help Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

    Icon Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    6/118

    QRC Substrate Technology Characterization Manual

    July 2011 6 Product Version 10.1.2 HF1

    A

    Input and Output Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

    Input Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Session Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

    Template Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

    Doping Concentration Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

    Output Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

    Technology Description Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

    B

    Preparing Doping Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Regions and Cross-Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

    Regions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

    Cross-Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

    Information Provided by the Process Engineer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

    Doping Profiles Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

    CMOS Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

    BiCMOS Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

    Information Relevant to QRC AoT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

    Beginning of the Doping Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

    Substrate Depth Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

    End of the Doping Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

    Doping Profile File Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

    Electrons and Holes Concentration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

    Net Carrier Concentration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

    Acceptor and Donor Concentration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

    Resistivity Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

    Recommendations for Creating Doping Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

    Substrate Depths for N-P and P-N Transitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

    Doping Profile Representations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

    Junction Representations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

    Doping Profile Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

    Start of the Doping Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

    Transition Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    7/118

    QRC Substrate Technology Characterization Manual

    July 2011 7 Product Version 10.1.2 HF1

    Final Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

    Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    8/118

    QRC Substrate Technology Characterization Manual

    July 2011 8 Product Version 10.1.2 HF1

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    9/118

    QRC Substrate Technology Characterization Manual

    July 2011 9 Product Version 10.1.2 HF1

    Preface

    About This Book

    This manual describes how to use QRC Technology Characterization Tool (TCT) tocharacterize your technology and generate a technology description file to use with QRC AoT.

    This manual covers the following topics:

    Chapter 1, Introduction,describes QRC TCTs function, design flow, inputs, outputs,and graphical user interface. It also provides some background information on substratecharacterization, substrate modeling, and the technology description that QRC TCTgenerates.

    Chapter 2, Getting Started,describes how to start and exit QRC TCT, how to use thefeatures of its main window, and how to use its file selection dialog boxes.

    Chapter 3, How to Use QRC TCT,explains how to perform QRC TCTs main functions.

    Chapter 4, Commands,describes the commands that are available in QRC TCTsgraphical user interface menus.

    Appendix A, Input and Output Files,describes QRC TCTs input and output files.

    Glossarydefines the terms and concepts that you should understand to use QRC TCTeffectively.

    Platforms

    This product is supported as a 32-bit executable on all currently supported platforms. It is notavailable as a 64-bit executable. Refer to the Whats New for the specific release you areusing for details of the supported platforms for that release.

    Operating System Versions and Patches

    For information about supported operating system versions and current patches, see therelease notes for the current release.

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    10/118

    QRC Substrate Technology Characterization ManualPreface

    July 2011 10 Product Version 10.1.2 HF1

    Syntactical Conventions

    This document uses the following syntactical conventions:

    Commands and parameters used on the command line are given in Courierfont:

    command_name

    Menu commands and the fields in dialog boxes in the graphical user interface are givenin Helveticaitalicfont:

    File Save

    An en dash () separates the menu name and the command name.

    Variables for which you are to substitute a value are given in Courieritalicfont:

    filename, cellname, layer_name

    File names are given in Courierfont:

    library.lib

    Angle brackets enclose optional parameters:

    Vertical bars (|) in commands indicate choices.

    Square brackets indicate that you must select one of the choices:

    [a|b|c]

    Square brackets followed by a plus sign mean that you can choose more than one of thechoices, but you must select at least one:

    [a|b|c]+

    Use white space (tabs or spaces) to separate a command and its arguments.

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    11/118

    QRC Substrate Technology Characterization Manual

    July 2011 11 Product Version 10.1.2 HF1

    1

    Introduction

    This chapter describes QRC TCTs function, design flow, inputs, outputs, and graphical userinterface. It also provides some background information on substrate characterization,substrate modeling, and the technology description that QRC TCT generates.

    Function

    QRC TCT, the technology characterization tool, prepares the technology description thatQRC AoT uses to generate the substrate macromodel.

    QRC TCT performs the following functions:

    Defines the available doping concentration profiles, drawn layers, and interfacelayers

    Loads the doping profiles

    Defines regions and cross-sectionsto identify available combinations of drawn layers

    Uses doping profiles to determine the depths of the vertical discretizationof thesubstrate

    Defines interface connection parameters for each interface layer to differentregion/cross-section combinations

    Defines interface connection types between the interface layers and the differentregion/cross-section combinations

    Computes vertical and horizontal impedance values for each subdivision of each dopingprofile

    Computes capacitance parameters for the p-n junctions between wells and the substrate

    Saves the technology file in an encrypted format

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    12/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 12 Product Version 10.1.2 HF1

    Substrate Characterization

    Substrate characteristics throughout silicon depend directly on carrier concentration. In aplanar technology, the concentration of electrons and holes is controlled by the fabricationprocess and set of mask layers:

    Drawn layers, which are used to create the circuit layout, define a set of masks used inthe circuit fabrication process. Figure 1-1 on page 12shows the top view of the layout forNMOS and PMOS transistors in a CMOStechnology, with their corresponding drawnlayer.

    Figure 1-1 NMOS and PMOS Layout

    Profile layersare masks that directly influence the lateral variation of the carrierconcentration across the substrate.

    Interface layers are mask layers above the substrate surface that can couple to thesubstrate surface resistively or capacitively. Normally, interface layers are interconnectlayers. The resistance and capacitance values between the substrate and the interfacelayer are known as the layers electrical connection parameters.

    Figure 1-2 on page 13shows a cross-section of the layout through the a-a axis for a p-substrate process, illustrating the different mask layers and identifying the interface andprofile layers.

    aa

    NMOS PMOS metal

    contact

    poly

    ndiff

    pdiff

    pwell

    nwell

    http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://-/?-http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    13/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 13 Product Version 10.1.2 HF1

    Figure 1-2 Cross-Section of a Standard CMOS Process

    Each combination of drawn layers produces a particular vertical carrier concentrationvariation known as the vertical doping profile. For any specific process, substratecharacteristics are fully described by a number of these profiles. Refer to Appendix B,Preparing Doping Profiles,for more information on defining these profiles.

    The following process steps are those most likely to influence substrate characteristics:

    Well implantation and diffusion

    Field and channel stop implants

    n+ and p+ implants used to contact the substrate

    QRC TCT defines available profile layers, interface layers, layer combinations, and theirassociated vertical doping profiles. It also divides the substrate into vertical subdivisions

    computed from vertical doping profiles. QRC uses this information and the layout of the circuitunder analysis to build an RC network that models the substrate. You can connect this RCnetwork to the ideal circuit netlist, as Figure 1-3 on page 14illustrates.

    Doping

    layers

    Interfacelayers

    http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    14/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 14 Product Version 10.1.2 HF1

    Figure 1-3 QRC AoT Substrate Model

    Substrate Model

    To generate a macromodel of the substrate, theQRC AoT extractor uses a simplifiedrepresentation of the layout with a specific technology description. This flow is pictured inFigure 1-4 on page 14.

    Figure 1-4 QRC AoT Simplified Flow

    The layout representation is called the substrate abstract view, which includes informationrelated to the generation of a surface mesh.

    Layout Abstract view Technology

    Partitioning

    Model construction

    Mesh

    http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    15/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 15 Product Version 10.1.2 HF1

    Technology Description

    The doping profiles for each combination of drawn layers are constant for a particularprocess. The technology description characterizes the substrate for each doping profile anddefines the vertical mesh of the initial substrate model, as illustrated in Figure 1-5 on page 15.

    Figure 1-5 Three-Dimensional Substrate Model

    QRC TCT saves the description in a technology descriptionfile, which includes informationsuch as mask layer combinations, vertical- and horizontal-specific resistances for eachvertical subdivision of the doping profiles, interface layers, interface parameters, andinterface connections. QRC TCT loads all these technology parameters to define a substratemodel and to link the access ports to external nodes.

    Three-Dimensional Modeling

    QRC TCTgenerates a three-dimensional mesh comprising a set of cells modeled as shownin Figure 1-6 on page 16.

    http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://-/?-http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    16/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 16 Product Version 10.1.2 HF1

    Figure 1-6 Electrical Model for a Single Cell

    For two such cells next to each other, the two impedances in series are joined by connection

    nodes. This arrangement simplifies to a single impedance, eliminating the connection nodes.As a result, the complete three-dimensional mesh model is a set of main nodes linked byimpedances.

    Impedance is determined by the following attributes:

    The doping profile

    Vertical subdivision within the profile

    Vertical Mesh Generation

    The process of generating a discrete mesh from the continuous vertical doping profilesinvolves a loss of accuracy. On one hand, the goal of vertical mesh generation is to preserveaccuracy by minimizing the total deviation from the vertical concentration profiles. On theother hand, the mesh must be coarse enough to ensure acceptable performance.

    QRC TCT produces vertical division intervals by placing boundaries at coordinates at whichthe profiles greatly change, such as junctions or n+ or p+ implant depth. More subdivisionsresult in a more accurate model but also increase processing time for model extraction.

    After mesh generation, QRC TCT computes the specific substrate resistance within eachinterval by using a piecewise constant approximation, explained in Figure 1-7 on page 17.

    Connection node

    Main node

    Impedance

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    17/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 17 Product Version 10.1.2 HF1

    Figure 1-7 Vertical and Horizontal Impedance Definition

    Carrier concentration variation is more pronounced near the substrate surface. Beyond acritical depth, the net carrier doping concentration can safely be assumed to be constant.

    Regions and Cross-Sections

    For better ease of use, QRC TCT uses regions and cross-sections.

    A region is identified by vertical p-n junctions with the same vertical position. All layout areashaving the same number of transitions at the same vertical position can be characterized asone region. Here are some examples:

    A default region, which is always present and does not contain any p-n junction

    A well region, such as an nwell in a p-doped substrate, which has one p-n junctionbetween the nwell and the substrate

    A triple well region, which may contain two p-n junctions, such as a pwell placed in ann pocket on top of the p substrate

    A deep well region, which is another nwell in a p-doped substrate but resides at a vertical

    depth different from the previous well region

    A cross-section is a name for a generic function shared by several regions. It defines theinterface between the substrate and devices and interconnects. Examples are the following.

    Default, which is always present and should be chosen to be the default cross-section

    Resistance

    Substrate

    Subdivision

    Wafer surfaceDoping profile

    Backside z (depth)

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    18/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 18 Product Version 10.1.2 HF1

    Contact, which defines a cross-section for a substrate contact, a well contact, a triple wellcontact, and so forth

    Source/drain, which defines all source and drain areas in all possible regions

    Combinations of regions and cross-sections are attached to resistivity profiles to enable aone-to-one mapping.

    Refer to the QRC Substrate Technology Characterization Tutorialfor illustratedexamples.

    Design Flow

    The QRC TCT design flow is illustrated in Figure 1-8.

    Figure 1-8 QRC TCT Program Flow

    Technology file

    Generate technology file

    Discretize profiles

    Load dopingprofiles Assign regions

    and cross-

    sections

    Enter interfaceparameters

    Enter interface

    connection types

    Enter profile layers,interface layers

    http://localhost/var/www/apps/conversion/tmp/substormtcttut/titlecopy.html#firstpagehttp://-/?-http://-/?-http://localhost/var/www/apps/conversion/tmp/substormtcttut/titlecopy.html#firstpage
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    19/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 19 Product Version 10.1.2 HF1

    Inputs

    QRC TCT accepts three inputs:

    A template file, which contains all the important values that define regions, cross-sections, and interface layers. Cadence provides the template files. Some examplesreside in $ASSURAHOME/share/sna/TCTtemplates. They are prepared for the mostcommon technologies and can be used as a basis for your technology. Template files areoptional. See Appendix A, Template Files,.

    Note: The TCT Template files are available in the Assura installation. They are notincluded with the EXT7.1 release.

    Doping concentration profiles, which contain information about electron and holeconcentration, net carrier concentration, acceptor and donator concentration, andresistivity. You can also submit doping profiles for junction capacitance calculation.These profiles must be obtained from the fabrication process department at your site.These files are required. See Appendix B, Preparing Doping Profiles,for moreinformation.

    Session files, which contain the values of all variables that you set in QRC TCT to allowyou to save the configuration of the tool and any work. QRC TCT reads and writes theseoptional session files. See Appendix A, Session Files,.

    Outputs

    QRC TCT creates the following outputs:

    A technology description file in an encrypted format. See Appendix A, TechnologyDescription Files,for more information.

    Session files, which contain the values of all variables that you set in QRC TCT.

    A template file, which contains all the important values that define regions, cross-sections, and interface layers.

    Graphical User Interface

    QRC TCTs graphical user interface enables you to set parameters while preparing atechnology description file. It gives you a maximum of control on all calculated or usedparameters. It controls the automatically generated subdivisions but allows you to add, move,or delete some of those manually.

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    20/118

    QRC Substrate Technology Characterization ManualIntroduction

    July 2011 20 Product Version 10.1.2 HF1

    The graphical user interface displays doping concentration profiles in several scales.

    After discretization, QRC TCT displays each subdivision as well as all the doping profiles, as

    shown in Figure 2-1 on page 22.

    http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    21/118

    QRC Substrate Technology Characterization Manual

    July 2011 21 Product Version 10.1.2 HF1

    2

    Getting Started

    This chapter describes how to start and exit QRC TCT, how to use the features of its mainwindow, and how to use its file selection dialog boxes.

    Starting QRC TCTYou can start QRC TCT from the UNIX command line prompt as follows:

    snatct [&]

    Note: The optional & starts the program in background mode.

    The main window now appears.

    QRC TCT Main Window

    QRC TCTs main window, shown in Figure 2-1 on page 22, is designed to show the dopingconcentration profiles as well as other important parameters.

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    22/118

    QRC Substrate Technology Characterization ManualGetting Started

    July 2011 22 Product Version 10.1.2 HF1

    Figure 2-1 QRC TCT Main Window

    The QRC TCT main window is resizable. It is divided into the following areas:

    The title banner shows the current session name and enables you to move the window.System buttons minimize (iconize), maximize, or restore the window size.

    The menu bar contains a set of pulldown menus.

    The icon bar displays shortcut icons that execute the most important commands in themenu bar. See Icon Toolbar on page 82for a description of each individual icon.

    The display panel displays doping profiles and subdivisions. You can view the results ofthe discretization and manually add or remove subdivisions.

    The scrollable log panel contains a log of the activities, warnings, and error messages.

    Title banner

    Menu bar

    Icon bar

    Display panel

    Discretization

    Log panel

    Status bar

    http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    23/118

    QRC Substrate Technology Characterization ManualGetting Started

    July 2011 23 Product Version 10.1.2 HF1

    The status bar provides contextual information, such as the currently activatedcommand.

    File Selection Dialog Boxes

    Many QRC TCT commands activate a file selection dialog box similar to that shown inFigure 2-2 on page 23.

    Figure 2-2 File Selection Dialog Box

    This dialog box contains the following fields:

    Filter

    Specifies a file path and matching pattern from which the contents of the Directoriesand Filesfields are determined. For example, if the last parameter in the path name is*.cmd, only files ending with .cmd are displayed in the Filesfield. If the last parameter inthe path name is an asterisk (*), all files in the specified path are listed.

    Directories

    Lists the subdirectories of the path that you selected in the Filterfield.

    Files

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    24/118

    QRC Substrate Technology Characterization ManualGetting Started

    July 2011 24 Product Version 10.1.2 HF1

    Lists the files that match the pattern specified in the Filterfield.

    Selection

    Displays the status of your selection process.

    To use this dialog box, follow these steps:

    1. To move to a directory, enter the path name of the directory in the Filterfield. To list thefiles that reside in that directory, specify /*after the path name.

    2. To select a subdirectory, double-click on the name of the subdirectory in the Directoriesfield.

    The Filterfield now shows the new path. The Directoriesand Filesfields are alsoupdated to reflect the contents of the new path.

    3. To select a file, double-click on the name of the file in the Filesfield. Alternatively, youcan single-click to update the Selectionbox.

    4. When you are finished with the selection process, click on OKto select what is shown inthe Selectionbox.

    Exiting QRC TCT

    To exit QRC TCT, do the following.

    1. Select Session Exit.

    A confirmation dialog box appears, as shown in Figure 2-3 on page 24.

    Figure 2-3 Exit QRC TCT Confirmation Box

    2. Click on OKto exit the tool.

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    25/118

    QRC Substrate Technology Characterization Manual

    July 2011 25 Product Version 10.1.2 HF1

    3

    How to Use QRC TCT

    This chapter explains how to perform QRC TCTs major functions.

    Starting a Session

    This section shows you how to create a new session or load an existing session. It also tellsyou how to revert to a previously saved session.

    Creating a New Session

    To clear the current database and start a new session, select Session New Session, orclick on the icon on the icon bar. Alternatively, you can press Ctrl Nwhen the QRC TCTmain window is active. All previous operations are lost, and the QRC TCT environment isreset. If you want to keep your current session, save it beforehand.

    If the $ASSURAHOME/share/sna/TCTtemplatesdirectory contains template files, thetemplate file selection window appears, as shown in Figure 3-1 on page 26. You can now loadone of the prepared sessions and adapt it to your needs.

    If no template files are available, only the database is cleared, and all variables are reset.

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    26/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 26 Product Version 10.1.2 HF1

    Figure 3-1 Template File Selection Window

    Loading an Existing Session

    To load an existing QRC TCT session, follow this procedure:

    1. Select Session Load Session, or click on the icon on the icon bar. Alternatively,you can press Ctrl Lwhen the QRC TCT main window is active.

    A file selection dialog box opens, as shown in Figure 3-2 on page 27.

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    27/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 27 Product Version 10.1.2 HF1

    Figure 3-2 Select a Session File Dialog Box

    2. Select an appropriate file, following the instructions in File Selection Dialog Boxes onpage 23.

    3. Click on OK.

    Reverting to a Saved Session

    If you want to revert to a session that has already been savedfor example, to undo all thechanges you made in the meantimechoose Session Revert to Saved. This commandrestarts the session from the point that you previously saved or loaded it.

    Alternatively, you can press CtrlRwhen the QRC TCT main window is active.

    Controlling the Screen DisplayBefore you begin creating the technology file with QRC TCT, it is helpful to understand howto zoom and pan the views that you see on-screen.

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    28/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 28 Product Version 10.1.2 HF1

    Zooming

    Zoomingis the process of magnifying or shrinking the view of a selected area of the chip. To

    zoom, you can use the commands on the Zoom submenu activated by the View Zoomcommand or the corresponding buttons on the icon bar.

    To zoom in on, or enlarge, a selected area, select View Zoom. Press and hold the leftmouse button around the area to enlarge. When you release the button, the view isreplaced by the enlarged view. You can also use the icon.

    To zoom in by a factor of 2, select View Zoom Zoom In. You can also use the ShiftZkeyboard command or the icon.

    To zoom out, or shrink the view, by a factor of 2, select View Zoom Zoom Out. Youcan also use the Ctrl zkeyboard command or the icon.

    Other zoom commands, such as zooming along the X axis, are also available. See Zoomon page 65for detailed information on these commands.

    Panning

    Panning is the process of obtaining a panoramic view of the design by selecting one pointas the center of the view without changing the scale of the design. You can pan the view tothe left, right, up, or down by half a screen.

    To pan left, select View Zoom Pan Left.You can also use the left arrow key.

    To pan right, select View Zoom Pan Right.

    You can also use the right arrow key.

    To pan up, select View Zoom Pan Up.

    You can also use the up arrow key.

    To pan down, select View Zoom Pan Down.

    You can also use the down arrow key.

    Controlling Grid Visibility

    To display or hide the grid, select View Grid. Alternatively, you can select the buttonon the icon bar.

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    29/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 29 Product Version 10.1.2 HF1

    Loading the Doping Profiles

    The first step in preparing the technology file is to load the doping concentration profiles thatwill be attached to the combination of regions and cross-sections.

    Specifying the Profile Default Directory

    To specify the directory where QRC TCT searches for the doping profiles, follow these steps:

    1. Choose Options Default Directory.

    The Select a Default Directory dialog box appears, as shown in Figure 3-3 on page 29,so you can specify the directory.

    Figure 3-3 Select a Default Directory Dialog Box

    2. Fill in the fields of the dialog box according to the instructions given in File SelectionDialog Boxes on page 23.

    3. Click on OK.

    Changing the Scale of the Ordinate

    You can change the scale of the doping concentration profiles.

    To display the concentration profiles of electrons and holes on a linear scale, select View Y-axis Scale Electrons And Holes (lin).

    http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    30/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 30 Product Version 10.1.2 HF1

    To display the concentration profiles of electrons and holes on a logarithmic scale, selectView Y-axis Scale Electrons And Holes (log).

    To display the net concentration profiles on a linear scale, select View Y-axis Scale Net Carriers (lin). Use a plus (+) sign to indicate that electrons are the majoritycarriers; use a minus (-) sign to indicate that holes are the majority carriers.

    To display the net concentration profiles on a logarithmic scale, select View Y-axisScale Net Carriers (log). Use a plus (+) sign to indicate that electrons are themajority carriers; use a minus (-) sign to indicate that holes are the majority carriers.

    To display the resistivity profiles on a linear scale, select View Y-axis Scale Resistivity (lin).

    To display the resistivity profiles on a logarithmic scale, select View Y-axis Scale

    Resistivity (log).

    Alternatively, use the following two icons to change the scale:

    Increases the scale and unit of the doping concentration profiles.

    Decreases the scale and unit of the doping concentration profiles.

    Controlling Doping Concentration Profile Visibility

    By selecting View Regions, you can display or hide doping concentration profiles in

    different ways. You can view all of them, you can view them by combinations of regions andcross-sections, or you can view none of them.

    Controlling Legend Visibility

    You can display the legend for the doping concentration profiles either by combinations ofregion and cross-section or by profile.

    1. Click on View Legendto display or hide the legend. Alternatively, you can click on theicon on the icon bar.

    The Legend dialog box appears, as shown in Figure 3-4 on page 31.

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    31/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 31 Product Version 10.1.2 HF1

    Figure 3-4 Legend Dialog Box

    2. Select Region/Cross-sectionor Profile.

    Specifying Regions, Cross-Sections, and Interface

    Layers

    The next step in generating a technology description is to specify the regions, cross-sections,and interface layers of the design.

    Specifying Region Names

    To specify region names, follow these steps:

    1. Select Edit Setup Region Names, or click on the icon.

    The Define Regions dialog box appears, as shown in Figure 3-5 on page 32.

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    32/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 32 Product Version 10.1.2 HF1

    Figure 3-5 Define Regions Dialog Box

    2. Use the Add, Modify, and Removebuttons to change the list of regions.

    To add a region to the list, do the following:

    a. Click on Add.

    The Create New Region dialog box appears, as shown in Figure 3-6 on page 32, soyou can specify the name of the region to add.

    Figure 3-6 Create New Region Dialog Box

    b. Type in the name of the region.

    c. Click on OK.

    To modify the name of a region in the list, do the following:

    a. Highlight the name of the region that you want to change.

    b. Click on Modify.

    c. The Add Region Name dialog box appears, as shown in Figure 3-7 on page 33.

    http://-/?-http://-/?-http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    33/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 33 Product Version 10.1.2 HF1

    Figure 3-7 Add Region Name Dialog Box

    d. Backspace over the existing name and type the name of the region that you wish toadd.

    e. Click on OK.

    To remove the name of a region from the list, do the following:

    a. Highlight the name of the region that you want to remove.

    b. Click on Remove.

    3. Click on Donein the Define Regions dialog box.

    You can use the Revertbutton to revert to the last saved list or the Cancelbutton toclose the window without saving.

    Specifying Cross-Sections

    You can use a cross-section in several regions. It has two purposes:

    It serves as a unique identification of the doping concentration profile to be used underan access port with the unique combination of region name and cross-section name.

    It specifies how interconnects are connected to the substrate model: resistively,capacitively, or not at all.

    Refer to Chapter 1, Introduction,for more information about regions and cross-sections.

    To specify cross-sections, do the following:

    1. Select Edit Setup Cross-Sections, or select the icon.

    The Cross-Sections dialog box appears, as shown in Figure 3-8 on page 34.

    http://qrctctman.pdf/http://-/?-http://qrctctman.pdf/http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    34/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 34 Product Version 10.1.2 HF1

    Figure 3-8 Cross-Sections Dialog Box

    2. Use the Add, Modify, and Removebuttons to modify the list of cross-sections and theirproperties.

    To add a cross-section to the list, do the following:

    a. Click on Add.

    The Add Cross-Section dialog box appears, as shown in Figure 3-9 on page 34, soyou can specify the name of the cross-section to add.

    Figure 3-9 Add Cross-Section Dialog Box

    b. Type in the name of the cross-section.

    c. In the Interface Connectionsfield, select Resistiveor Capacitive.

    d. Click on OK.

    To modify the name of a cross-section in the list, do the following:

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    35/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 35 Product Version 10.1.2 HF1

    a. Highlight the name of the cross-section that you want to change.

    b. Click on Modify.

    c. The Modify Cross-Section dialog box appears, as shown in Figure 3-10 on page 35.

    Figure 3-10 Modify Cross-Section Dialog Box

    d. Backspace over the existing name and type the name of the cross-section that youwish to add.

    e. In the Interface Connectionsfield, select Resistiveor Capacitive.

    f. Click on OK.

    To remove the name of a cross-section from the list, do the following:

    a. Highlight the name of the cross-section that you want to remove.

    b. Click on Remove.

    3. Click on Donein the Cross-Section dialog box.

    4. Define the interface connections by selecting one of the following options.

    Nothing selected

    If you neither select Resistivenor Capacitive, a connection between an access

    port and the substrate model will not be allowed for this type of cross-section.

    Resistive

    Enables a resistive connection between an access port and the substrate model.

    Capacitive

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    36/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 36 Product Version 10.1.2 HF1

    Enables a capacitive connection between an access port and the substrate model.Choose the type of capacitive connection appropriate for this cross-section:

    interConnectOnFieldSelects the interconnects that connect to the substrate but that do not resideabove a region where a device is located.

    interConnectOnActive

    Selects the interconnects that connect to the substrate and that reside above aregion where a device is located.

    gate

    Selects the interconnects that connect to the substrate through the gate of MOS

    transistors.

    Specifying Interconnect Layer Names

    Now you will specify the layer names of the interconnects in your design:

    1. Select Edit Setup Interface Interconnects, or click on the icon.

    The Interconnects dialog box opens, as shown in Figure 3-11 on page 36.

    Figure 3-11 Interconnects Dialog Box

    2. Use the Add, Modify, and Removebuttons to change the list of interconnect layers.

    To add a layer name to the list, do the following:

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    37/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 37 Product Version 10.1.2 HF1

    a. Click on Add.

    The Create New Interconnect dialog box appears, as shown in Figure 3-12 on

    page 37, so you can specify the name of the layer to add.

    Figure 3-12 Create New Interconnect Dialog Box

    b. Type in the name of the layer.

    c. Click on OK.

    To modify the name of a layer in the list, do the following:

    a. Highlight the name of the layer that you want to change.

    b. Click on Modify.

    c. The Add Interconnect Name dialog box appears, as shown in Figure 3-13 onpage 37.

    Figure 3-13 Add Interconnect Name Dialog Box

    d. Backspace over the existing name and type the name of the layer that you wish toadd.

    e. Click on OK.

    http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    38/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 38 Product Version 10.1.2 HF1

    To remove the name of a layer from the list, do the following:

    a. Highlight the name of the layer that you want to remove.

    b. Click on Remove.

    3. Click on Doneto effect the changes.

    Specifying the Gate Layer Names

    Finally, specify the layer names of the interconnects in your design serving as the gate layer:

    1. Select Edit Setup Interface Gates, or click on the icon.

    The Gates dialog box appears, as shown in Figure 3-14 on page 38.

    Figure 3-14 Gates Dialog Box

    2. Use Add, Modify, and Removebuttons to change the list of interconnect layers thatconnect to gates of MOS transistors. Follow the procedure in step 2in SpecifyingInterconnect Layer Names on page 36.

    3. Click on Donein the Gates dialog box to implement the changes.

    Attaching Doping Profiles to Regions/Cross-Sections

    The next step is to attach the doping concentration profiles given in ASCII files to thecombinations of regions and cross-sections. If you started without using one of the templates,the first combination of region and cross-section is always composed of the default region andthe default cross-section.

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    39/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 39 Product Version 10.1.2 HF1

    Attaching Doping Profiles to the Default/Default Combination

    First, attach doping concentration profiles to the default combination of regions and cross-

    sections.

    1. Select Edit Region Parameters, or click on the icon.

    The Regions Parameters dialog box opens, as shown in Figure 3-15 on page 39.

    Figure 3-15 Regions Parameters Dialog Box

    2. In the Region Namefield, choose the name of the defaultregion.

    3. Click on Cross-Sections.

    The Select a Doping Profile dialog box, shown in Figure 3-16 on page 39, appears soyou can select the appropriate doping concentration profile.

    Figure 3-16 Select a Doping Profile Dialog Box

    http://-/?-http://-/?-http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    40/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 40 Product Version 10.1.2 HF1

    4. Select a doping profile, using the instructions given in File Selection Dialog Boxes onpage 23.

    5. Click on OKin the Select a Doping Profile dialog box.The doping profile attachment window now appears, as shown in Figure 3-17 onpage 40.

    Figure 3-17 Doping Profile Attachment Window

    6. You can change the parameters in this window by following the instructions in Changingthe Doping Profile Display Parameters on page 42.

    7. Click on OKin the doping profile attachment window.

    Now the cross-section selection dialog box appears, as shown in Figure 3-18 onpage 41.

    http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    41/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 41 Product Version 10.1.2 HF1

    Figure 3-18 Cross-Section Selection Dialog Box

    In the title of the cross-section selection dialog box, the name of the actual region isdisplayed; for example, in Figure 3-18 on page 41the default region is shown. The dialogbox contains two sections: the Selected Cross-Sectionsbox contains the alreadyselected cross-sections, and the Available Cross-Sectionsbox contains the availablecross-sections.

    8. Attach other profiles to other cross-sections for the default region:

    a. In the cross-section selection dialog box, select an available cross-section in the listat the right, and click on the left arrow.

    The Select a Doping Profile dialog box shown in Figure 3-16 on page 39opens.

    b. Select a profile, and click on OK.

    The Select a Doping Profile dialog box now closes, and the doping profileattachment window shown in Figure 3-17 on page 40opens.

    c. You can change the parameters in this window by following the instructions given inChanging the Doping Profile Display Parameters on page 42and clicking on OKin the doping profile attachment window.

    The cross-section selection dialog box opens.

    9. Repeat step 8until all necessary cross-sections for the default region are attached todoping profiles.

    10. In the cross-section selection dialog box, click on Done.

    The cross-section selection dialog box now closes but the Regions Parameters dialogbox remains open.

    http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    42/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 42 Product Version 10.1.2 HF1

    11. Attach profiles to other regions:

    a. Choose a second region, for example, nwell.

    b. Click on Cross-Section.

    The Select a Doping Profile dialog box appears.

    c. Select a profile, and click on OK.

    The Select a Doping Profile dialog box closes, and the doping profile attachmentwindow opens.

    d. You can change the parameters in this window by following the instructions given inChanging the Doping Profile Display Parameters on page 42and clicking on OKin the doping profile attachment window.

    The doping profile attachment window closes. The cross-section selection dialogbox opens.

    12. Repeat step 11until all necessary cross-sections for the second region are attached todoping profiles.

    13. In the cross-section selection dialog box, click on Done.

    The cross-section selection dialog box now closes. The Regions Parameters dialog boxremains open.

    14. Repeat steps step 11through step 13until all necessary region/cross-sectioncombinations are attached to doping profiles.

    15. In the Regions Parameters dialog box, click on Done.

    Changing the Doping Profile Display Parameters

    Figure 3-17 on page 40shows the doping profile attachment window. At the top, this windowcontains the path to and the name of the file with the doping concentration. The displayedgraphs vary according to the format of this file; for example, in Figure 3-17 on page 40thedoping concentration profile for the default region and the contact cross-section is given in

    electrons and holes.

    1. You can change the way of displaying these profiles by clicking on the following fields onthe doping profile attachment window:

    Set Color

    Opens a color definition window, enabling you to change the default color.

    http://-/?-http://-/?-http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    43/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 43 Product Version 10.1.2 HF1

    Line Style

    Sets the line style. You can choose from solid, dot, long dashed, short dashed, or

    dot dashed. Horizontal Axis

    Displays the maximum and minimum value of the depth for this doping profile.

    Default

    Re-enters the default values for the axis.

    Redraw

    Updates the screen.

    Vertical Axis

    Displays the profiles in linear scale or in logarithmic scale.

    2. Click on OK.

    Discretizing the Substrate

    You can specify how the substrate will be vertically discretized. The discretization dependson the following:

    The doping concentration profiles and their slopes

    The parameters set in the Options menu

    The critical depth and the backside depthare important values. From surface to criticaldepth, profiles exhibit much variation in carrier concentration. QRC TCT discretizes thisregion in small subdivisions to achieve an accurate model. From critical depth to the backsideof the substrate, the subdivisions are coarser because the carrier concentration is assumedto be constant in this region. QRC TCT takes the last value found in each doping profile.Figure 3-19 on page 44illustrates critical depth and backside depth.

    http://qrctctman.pdf/http://-/?-http://-/?-http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    44/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 44 Product Version 10.1.2 HF1

    Figure 3-19 Definition of Critical Depth and Backside Depth

    Changing the Discretization Parameters

    QRC TCT automatically calculates the critical depth, but you can change it manually in thedialog box activated by the Options Discretizationcommand. You can also use thiscommand to enter values for the backside depth.

    1. Select Options Discretization.

    The Discretization dialog box appears, as shown in Figure 3-20 on page 45.

    Min depth

    Critical

    depth

    Backside

    depth

    Doping profiles

    0

    z z

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    45/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 45 Product Version 10.1.2 HF1

    Figure 3-20 Discretization Dialog Box

    See Discretization on page 60for an explanation of these fields.

    2. Click on Doneto set the discretization parameters.

    If you have already performed a discretization or if you have changed a session containingdiscretizations, QRC TCT issues a warning message to inform you that it is overwriting thediscretization parameters and therefore the discretization.

    http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    46/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 46 Product Version 10.1.2 HF1

    Starting a Discretization

    To start a discretization, select Subdivision Discretization.

    If all parameters are set correctly and if the doping profiles pass several verifications, theproposed discretization is displayed in QRC TCTs display panel.

    Changing a Discretization Manually

    You may want to change the discretization manually. Use the commands on the Subdivisionmenu.

    Remember that you must weigh speed versus accuracy when deciding on the number of

    subdivisions. A high number of subdivisions results in a higher level of accuracy, but QRCTCT takes longer to extract the substrate model. A low number of subdivisions results in alower level of accuracy but increases the extraction speed.

    Controlling Subdivision Visibility

    You can display or hide the subdivisions by selecting View Subdivisions. You can onlydisplay them if you have previously performed a discretization. Alternatively, you can click onthe icon on the icon bar.

    Moving a Subdivision

    To move a subdivision, follow these steps:

    1. Select Subdivision Move. Alternatively, you can select Ctrl M, or click on theicon.

    2. Place the cursor on the dedicated subdivision. The cursor style changes.

    3. Left-click on the subdivision, and drag it to the left or to the right. A subdivision can onlybe moved between its neighbor subdivisions.

    4. Exit move mode by clicking on Subdivision Move.

    Adding a Subdivision

    To add a subdivision, follow these steps:

    1. Select Subdivision Add. Alternatively, you can select Ctrl A, or click on theicon.

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    47/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 47 Product Version 10.1.2 HF1

    2. Type in the X coordinate of the new subdivision.

    3. Click on OK.

    The subdivision is added in QRC TCTs display panel.

    Note: In cases where sufficient number of subdivisions have not been selected near the topsurface, then QRC TCT asks the user whether it should automatically insert additional sub-divisions. This feature is designed to help ensure sufficient accuracy near the critical surfaceinterface.

    Deleting a Subdivision

    To delete a subdivision, follow these steps:

    1. Select Subdivision Delete. Alternatively, you can select Ctrl D, or click on theicon.

    2. Place the cursor on the dedicated subdivision.

    The cursor style changes.

    3. Left-click on the subdivision to be deleted.

    4. Exit delete mode by clicking on Subdivision Delete.

    Some of the discretizations cannot be removed because they are necessary to maintain

    accuracy.

    Undoing and Redoing Changes to a Subdivision

    To reverse the last changes to a subdivision, select Subdivision Undo. Alternatively, youcan select u, or click on the icon.

    To re-execute the last changes to a subdivision, select Subdivision Redo. Alternatively,you can select r, or click on the icon.

    Changing Region Parameters

    You can change the region parameters.

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    48/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 48 Product Version 10.1.2 HF1

    Changing the Junction Parameters of a Region

    If a region contains p-n junctions, for example, between the n-doped well and the p-doped

    substrate, QRC adds capacitors to model the junction capacitance between both sides of thep-n junction. To change the junction parameters for a region, follow these steps. To calculatethe junction capacitance for two-dimensional doping profiles, see the next section.

    1. To change a regions junction parameters, click on Edit Regions Parameters, or clickon the icon.

    The Regions Parameters dialog box appears, as shown in Figure 3-21 on page 48.

    Figure 3-21 Regions Parameters Dialog Box

    2. In the Region Namelist, select a region containing p-n junctions.

    3. Click on Junction Parameters.

    The Junction Parameters dialog box appears, as shown in Figure 3-22. This exampleshows the Junction Parameters dialog box for an nwell with one p-n junction.

    Figure 3-22 Junction Parameters Dialog Box

    4. You can determine the area and perimeter capacitance values used for these capacitorsin different ways:

    Calculated

    http://-/?-http://-/?-http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    49/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 49 Product Version 10.1.2 HF1

    Automatically determines the capacitance values.

    User-Defined

    Enables you to define the perimeter and area capacitance values. If your regioncontains several p-n junctions, several fields appear for you to enter the perimeterand area values.

    2-D Geometry

    Accepts a file that is generated from a process simulator and that contains two-dimensional doping concentration information. QRC accepts MEDICI, SUPREM,and ISEfile syntax.

    5. Click on OKto change the parameters.

    Calculating Junction Capacitance for Two-Dimensional Doping Profiles

    The capacitance values required to model junction capacitors for the p-n junctions in thedifferent regions can be calculated by QRC TCT, user-defined with fixed values, or derivedfrom two-dimensional geometry. If you want to use two-dimensional geometry, Cadencerecommends that you read this section.

    1. Click on Edit Regions Parameters.

    The Regions Parameters dialog box appears, as shown in Figure 3-21 on page 48.

    2. Select a region with p-n junctions in the Regions Parameters dialog box.

    3. Click on Junction Parameters.

    The Junction Parameters dialog box appears, as shown in Figure 3-22 on page 48.

    4. Choose 2-D Geometry, and click on OK.

    You are asked to provide a file with two-dimensional geometry and doping profileinformation. You can generate this file with process simulators. QRC TCT supportsSUPREM and MEDICI.

    5. Define a cut through the regions under consideration containing the p-n junctions. Thiscut must be two-dimensional. For more details on this issue, contact Cadence CustomerSupport.

    Setting Interface Parameters for Interconnects

    Follow this procedure to set the interface parameters for the interconnects:

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://-/?-http://-/?-http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    50/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 50 Product Version 10.1.2 HF1

    1. Select Edit Interface Parameters Interconnect, or click on the icon.

    The Interconnect Parameters dialog box appears, as shown in Figure 3-23 on page 50.

    Figure 3-23 Interconnect Parameters Dialog Box

    2. Select one layer after the other from the Interconnectfield, and set the appropriatevalues for resistance [ohm*m2] and capacitance for area [fF/m2] and perimeter [fF/m].

    3. Click on OK.

    Here are some examples from a simple CMOS technology:

    A metal_2 layer is never connected to contacts, so the resistance values are -1. Incontrast, there may be a capacitive connection between a metal_2 layer and thesubstrate, so at least the area capacitance values should be entered. For additionalaccuracy, you can use the perimeter capacitance values.

    A polysilicon layer is never connected to contacts, so the resistance values are -1. Incontrast, there may be a capacitive connection between a polysilicon layer and thesubstrate, so at least the area capacitance values should be entered. For additionalaccuracy, you can use the perimeter capacitance values. In contrast to the metal_2 layer,the area value for a capacitive interface on field oxide is higher, since the distancebetween the polysilicon layer and the substrate is smaller than the distance between themetal_2 layer and the substrate.

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    51/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 51 Product Version 10.1.2 HF1

    A metal_1 layer is the interface layer for the contacts. A 10-ohm*m2resistance value isgiven to model the resistivity of the contact metallization. The values may be different forn-contacts and p-contacts. There may also be a capacitive connection between a

    metal_1 layer and the substrate, so at least the area capacitance values should beentered. For additional accuracy, you can use the perimeter capacitance values.

    Setting Interface Parameters for Gates

    To set the interface parameters for gates, perform these steps:

    1. Select Edit Interface Parameters Gate, or click on .

    The Gate Parameters dialog box appears, as shown in Figure 3-24.

    Figure 3-24 Gate Parameters Dialog Box

    2. Select one layer after the other from the Gatesfield, and set appropriate values for

    capacitance for area [fF/m2

    ] and perimeter [fF/m].3. Click on OK.

    Setting Interface Parameters for Devices

    To set the interface parameters for devices, do the following:

    http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    52/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 52 Product Version 10.1.2 HF1

    1. Select Edit Interface Parameters Device, or click on the icon.

    The Device Parameters dialog box appears, as shown in Figure 3-25 on page 52.

    Figure 3-25 Device Parameters Dialog Box

    By default, all devices are connected resistively to the substrate. You can change to acapacitive connection by setting capacitance values for area [fF/m2] for the differentcross-sections available.

    2. Select one region after the other from the Regionsfield, and set appropriate values forthe different cross-sections.

    3. Click on OK.

    Creating the Output

    This section describes how to save a session, a template, and a technology description.

    Saving a Session

    Save your current QRC TCT session by following these steps:

    1. Select Session Save Session, or click on the icon on the icon bar. Alternatively,you can press Ctrl Swhen the QRC TCT main window is active.

    The file selection dialog box shown in Figure 3-26 on page 53appears so you can enterthe name of the session to save.

    http://-/?-http://-/?-http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    53/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 53 Product Version 10.1.2 HF1

    Figure 3-26 Save Session File Selection Dialog Box

    The current database, including profiles path and settings, is stored in a file. You canchoose any file name and suffix, but since the default filters expect a .tct suffix, it isrecommended that you use a .tct suffix.

    2. Select an appropriate file, following the instructions in File Selection Dialog Boxes onpage 23.

    3. Click on OK.

    Before saving a session, QRC TCT performs several tests. It may issue warningmessages, asking you to add or change something before saving. If you want to save thesetup in a template file, use the Session Exportcommand, as described in theExporting a Template File on page 53.

    When you save a session, QRC TCT preserves all current information, including the paths tothe doping profiles, interface parameters, options, and environment settings.

    Exporting a Template File

    A template file contains only the basic information about a session that can be applied tosimilar sessions. For example, in the $ASSURAHOME/share/sna/TCTtemplatesdirectory, you will find two templates, one for a CMOS technology and the other for BiCMOStechnology. They contain the predefined regions, cross-sections, and interconnect layers thatyou can use as a starting point to adapt the technology.

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    54/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 54 Product Version 10.1.2 HF1

    1. Select Export Setup.

    The Export Setup file selection dialog box appears, as shown in Figure 3-27.

    Figure 3-27 Export Setup File Selection Dialog Box

    2. Follow the instructions given in File Selection Dialog Boxes on page 23to select a filename.

    The default file name is default.tct.

    3. Click on OKto save the file.

    Saving the Technology Description

    The final step in using QRC TCT is to generate a technology description that can be used byQRC. The technology description file is called SCtechnology.XXX, where XXXis a user-defined extension. You can save the technology file in an Encrypted format.

    If you choose this format, you can see the global parameters such as regions and cross-sections with a text editor, but all technological parameters are in encrypted format, which isunreadable. You can use one of two ways to save the technology description in encryptedformat:

    Select Session Export Description Encrypted.

    http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    55/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 55 Product Version 10.1.2 HF1

    Click on the button on the icon bar.

    1. Using the method just described, select the output format.

    A file selection dialog box opens, asking you to specify the location and the file name ofthe technology description file. Usually technology description files are namedSCtechnology.XXXX, where the XXXXextension gives additional information on thetechnology.

    2. Select an appropriate file, following the instructions in File Selection Dialog Boxes onpage 23.

    3. Move to an appropriate directory, and type in a file name, for example,SCtechnology.bicmos.crypt.

    4. Click on OKto start the export routine.

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    56/118

    QRC Substrate Technology Characterization ManualHow to Use QRC TCT

    July 2011 56 Product Version 10.1.2 HF1

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    57/118

    QRC Substrate Technology Characterization Manual

    July 2011 57 Product Version 10.1.2 HF1

    4

    Commands

    This chapter describes the commands that are available in QRC TCTs graphical userinterface menus.

    Session MenuThe Session menu is shown in Figure 4-1 on page 57.

    Figure 4-1 Session Menu

    New Session

    The Session New Sessioncommand clears the current database and starts a newsession. If the $ASSURAHOME/share/sna/TCTtemplates directory contains template files,the template file selection window shown in Figure 4-2 on page 58appears. If no templatefiles are available, only the database is cleared, and all variables are reset.

    http://-/?-http://-/?-http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    58/118

    QRC Substrate Technology Characterization ManualCommands

    July 2011 58 Product Version 10.1.2 HF1

    Figure 4-2 Template File Selection Window

    Load Session

    The Session LoadSessioncommand loads an existing QRC TCT session. It activatesa file selection dialog box that enables you to select the session to load. See File SelectionDialog Boxes on page 23for instructions on using this dialog box.

    Save Session

    The Session Save Sessioncommand saves the current QRC TCT session. It activatesa file selection dialog box that enables you to select the session to save. See File SelectionDialog Boxes on page 23for instructions on using this dialog box.

    Revert to Saved

    The Session Revert to Savedcommand restarts a session from the point at which youpreviously saved it, discarding any changes you may have made subsequently.

    Export

    The Session Exportcommand saves the technology description. It activates the Exportmenu, shown in Figure 4-3 on page 59.

    http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    59/118

    QRC Substrate Technology Characterization ManualCommands

    July 2011 59 Product Version 10.1.2 HF1

    Figure 4-3 Export Menu

    Setup

    The Session Export Setupcommand allows you save a session as a template file. It

    activates a file selection dialog box so that you can select a file name for it. See File SelectionDialog Boxes on page 23for instructions on using this dialog box.

    Description

    The Session Export Descriptioncommand saves the technology file in an encryptedformat.

    Encrypted

    The Session Export Description Encryptedcommand saves the technology file ina format that enables you to see the global parameters like regions and cross-sections witha text editor, but all technological parameters are in encrypted format, which is unreadable.

    Exit

    The Session Exitcommand exits QRC TCT. It brings up the confirmation box shown inFigure 4-4 on page 59.

    Figure 4-4 Exit QRC TCT Confirmation Box

    http://qrctctman.pdf/http://qrctctman.pdf/http://-/?-http://-/?-http://qrctctman.pdf/http://qrctctman.pdf/
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    60/118

    QRC Substrate Technology Characterization ManualCommands

    July 2011 60 Product Version 10.1.2 HF1

    Options Menu

    Figure 4-5 on page 60shows the Options menu.

    Figure 4-5 Options Menu

    Default Directory

    The Options Default Directorycommand specifies the default directory for storing doping

    profiles. It activates a file selection dialog box so you can select the name of the directory. SeeFile Selection Dialog Boxes on page 23for instructions on using file selection dialog boxesin QRC TCT.

    Discretization

    The Options Discretizationcommand enables you to change the discretizationparameters. It activates the Discretization dialog box, shown in Figure 4-6 on page 61.

    http://-/?-http://qrctctman.pdf/http://-/?-http://qrctctman.pdf/http://-/?-http://-/?-
  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    61/118

    QRC Substrate Technology Characterization ManualCommands

    July 2011 61 Product Version 10.1.2 HF1

    Figure 4-6 Discretization Dialog Box

    The Discretization dialog box contains the following fields:

    Backside Depth

    Changes the depth of the backside, that is, the thickness of the die. It is given in microns.

    Temperature

    Specifies the operation temperature, in degrees Celsius or Kelvin.

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    62/118

    QRC Substrate Technology Characterization ManualCommands

    July 2011 62 Product Version 10.1.2 HF1

    Mobility tuning

    The mobility tuning factor takes into consideration any changes in mobility in the process

    to ensure that the doping information is translated into accurate resistivity information.There are separate tuning commands for electrons and holes

    Mobility tuning for holes

    This command specifies a tuning factor for holes to allow you to tune the internalcalculation of resistivity of the Substrate technology file.

    Mobility tuning for electrons

    This command specifies a separate tuning factor for electrons to allow you to tunethe internal calculation of resistivity of the Substrate technology file.

    Tuning for junction capacitors

    Specify a positive value which acts as a linear scaling factor, or tuning factor, for junctioncapacitors extracted during substrate extraction in the QRC AoT flow. The default valueis 1.0.

    Number of Subdivisions

    Defines the number of subdivisions above and below the critical depth. The critical depthis the distance from the surface of the substrate to the border of the homogenous dopingconcentration.

    SamplingSamples the doping concentration profiles to define several substrate layers. You candefine the sampling in either of two ways:

    Step

    Samples the doping profiles with a constant step width. The units are given inmicrons.

    Sample

    Samples the doping profiles with a certain number of samples.

    Transition Tolerance

    Specifies the tolerance to use for p-n transitions in the doping profiles. The dopingprofiles must show the transition between areas dominated by electrons and areasdominated by holes at the same vertical depth. Sometimes doping concentration profilesderived from measurements do not lead to a sufficient overlap of the transitions because

  • 8/11/2019 QRC Substrate Technology Characterization Manual.pdf

    63/118

    QRC Substrate Technology Characterization ManualCommands

    July 2011 63 Product Version 10.1.2 HF1

    of measurement deviations. This parameter allows you to set some tolerance in thetransition, in microns.

    CompressSpecifies where the subdivisions are concentrated. This compression factor influencesthe calculation of the subdivisions. A value less than 1 concentrates the subdivisions inthe vicinity of the p-n transition. A value greater than 1 concentrates the subdivisions atthe surface of the substrate.

    Maximum Junction Potential Drop

    Sets the maximum allowable potential dro