ProjectWise (SELECTseries 3) Whats · PDF file...

Click here to load reader

  • date post

    17-Jul-2020
  • Category

    Documents

  • view

    0
  • download

    0

Embed Size (px)

Transcript of ProjectWise (SELECTseries 3) Whats · PDF file...

  • Reasons to Upgrade ProjectWise Integration Server V8i (SELECTseries 3)

  • ProjectWise V8i (SELECTseries 3) Themes

    • AutoCAD and Revit 64-bit

    • Administration and Usability

    • Performance

    • Compatibility and Ease of Upgrade• Compatibility and Ease of Upgrade

    Not a complete list of changes in V8i (SELECTseries 3)

  • AutoCAD and Revit 64-bit Support

    • Now support 64-bit and 2011 products

    • Revit Version Support:

    – 2011 64 and 32 bit

    – 2010 64 and 32 bit

    • AutoCAD Version Support:

    – 2011 64 and 32 bit

    – 2010 64 and 32 bit

    – 2009 32 bit

    – 2008 32 bit

  • Granular Administration

    • Allow organizations to delegate responsibility for certain administrative functions to specific users without providing them full access to all administrative functions

    • Access to administrative functions set by node:• Access to administrative functions set by node: – Workflow

    – Environments

    – Workspace

    – Etc.

  • Granular Administration

  • Group/User List Membership Mgmt

    • Allow non-Administrator users to manage membership of Groups/User Lists

    • Available from PW Admin and PW Explorer

    • Must be a Group/UL owner (or in Administrator Group) to modify membershipmodify membership

    • Each Group/UL may have multiple owners

    • Requires a V8i (SELECTseries 3) datasource for full editing capabilities from ProjectWise Explorer

    – V8i (SELECTseries 3) Explorer connecting to previous version datasource will allow read-only access to this dialog

  • Group/User List Membership Management

  • Simplified Access Control Interface

    • Provide easier user experience for reviewing and setting access control for projects, folders and documents

    • Does not provide any additional editing rights beyond what is already available to user

    • Provides mechanism for applying access control templates

    • Apply settings to other folders

    • Export/Import access control settings

  • Access Control Editor User Interface

  • • SharePoint 2010, 2007 and stand-alone IIS integration

    • Interactive 3D model visualization

    • 2D plan set review

    ProjectWise Navigator Web Part

    • Simple analysis capabilities: content search, dimension measuring, business data review.

  • Integrated with ProjectWise

    Free text search &

    Simple search builderBusiness properties

    Supports viewing 2D plan sets

    Interactive 3D / 2D Viewing

    inside a browser

    ProjectWise workflow

    Simple search builder

    Dimension measuring

    Business properties to review and search by

  • Administration and Usability

    • Granular administration

    • Group/User list management

    • Simplified access control interface in preview pane

    • Audit trail improvements

    • Available storage area disk-space dialog

    • New datasource statistics

    • Removal of BRG file

    • Classless inter-domain routing

    • PDF file property indexing

  • High Latency Performance Optimizations

    • Optimize a number of ProjectWise operations when used in a high latency environment – Typically reduces the number of request/response roundtrips between ProjectWise Explorer and Integration Server

    • Enhanced operations include: – Document list display and folder navigation in ProjectWise Explorer and integrated dialogs in applications

    – Login

    – MicroStation file open

    – MicroStation reference file attachment

    – Titleblock update operations

  • High Latency Performance Examples

    Action (SELECTseries 2) 300 ms

    (SELECTseries 3) 300 ms

    Improvement

    Login last used folder enabled

    36 sec 22 sec 64%

    Select subfolder PW Explorer content list or in integrated dialog

    7 sec 3 sec 133%

    Display file list 7 sec 3 sec 133%

    File open from PW 59 sec 38 sec 55%File open from PW Explorer MicroStation with titleblocks enabled

    59 sec 38 sec 55%

    Update titleblocks from MicroStation

    44 sec 25 sec 76%

    Copy out multiple files

    114 sec 94 sec 21%

  • File Transfer Connection Sharing

    • Reduce overhead when transferring lots of files

    • Main benefit will be actions like managed workspaces with lots of workspaces with lots of smaller files

    • 60%+ performance improvements possible

  • File Transfer Connection Sharing

    • Time to launch MicroStation with managed workspace enabled – MicroStation V8i (SELECTseries 2)

    – Managed workspace with 14 CSBs and 1100 files totaling about 118 Mb

    – Local network(no latency)

    V8i (SELECTseries 2)

    V8i (SELECTseries 3)

    Improvement

    Initial Open (copy out all workspace files)

    6:33 2:30 65%

    Second Open (validate workspace is up to date)

    0:14 0:13 7%

  • “Install Over” Installation Capability

    • Allow 1-step upgrade of previous V8i releases

    • Supports ProjectWise Explorer, Administrator, Caching Server and Gateway Service

    • Avoids un-install/re-install

    • Works between SELECTseries releases, but not • Works between SELECTseries releases, but not between major releases

    • PW Explorer still supports side-by-side installation for major releases

    • Supports automated install mechanisms (SMS, msiexec scripts, etc)

  • ProjectWise Client/Server Compatibility

    Integration Server V8i (SELECTseries 3)

    Integration Server V8i (SELECTseries 2)

    Integration Server V8i (SELECTseries 1)

    Integration Server V8i

    Integration Server pre-V8i

    Explorer V8i (SELECTseries 3) X X X

    Explorer V8i (SELECTseries 2) X X X

    Explorer V8i (SELECTseries 1) X X X

    Explorer V8i X X X X

    Explorer pre-V8i X

    ProjectWise Admin Clients must match server version

  • V8i (SELECTseries 3) Compatibility

    Servers

    • Windows 2008 R2 64-bit

    • Windows 2008 SP2 64-bit

    Clients

    • Windows 7 32 and 64-bit

    • Windows Vista 32 and 64-bit

    Databases

    • Oracle 11g

    • Oracle 10g

    • SQL Server SP2 64-bit

    • Windows 2003 R2 64-bit

    • Windows 2003 R2 32-bit

    32 and 64-bit

    • Windows XP 32 and 64-bit

    • SQL Server 2008 R2

    • SQL Server 2008 SP2

    • SQL Server 2005

    Compatibility table published in the ProjectWise readme

  • V8i (SELECTseries 3) Compatibility

    • MicroStation 8.11.x, 8.9.x, V8.5.x, V8.1, V7.1.x

    • PowerDraft 8.11, 8.9.3, V8.5.x, V8.1, V7.1.x

    • Bentley View 8.11.7

    • Bentley Navigator 8.11.8, 8.11.7 (V8i SELECTseries 2)

    • Bentley i-model Composer 8.11.8, 8.11.7 (V8i SELECTseries 2)

    • AutoCAD 32-bit 2011, 2010, 2009, 2008• AutoCAD 32-bit 2011, 2010, 2009, 2008

    • AutoCAD 64-bit 2011, 2010

    • Revit 2011, 2010 (64 and 32-bit)

    • Microsoft Office 2007, 2003

    • Project 2007, 2003

    • Visio 2007, 2003

    Application integration compatibility table published on Be Communities at http://communities.bentley.com/products/projectwise/m/projectwise_gallery /146108.aspx and in the ProjectWise readme

  • V8i SELECTseries 3 Themes

    • AutoCAD and Revit 64-bit

    • Administration and Usability

    • Performance

    • Compatibility and Ease of Upgrade• Compatibility and Ease of Upgrade