Graphic Operator Interface

Low Light Reflection and Ultra High-brightness ModelDisplay on GP-3300U*

Display on a standard model*

AGP-3300UModel Number: AGP-3300-U1-D24* Display images when installed in well-lighted locations.

A New Solution from Pro-face for Applications Installed in Well-lighted Locations.isibility Sharp V !

Reason

1

isibility Sharp V

!

Designed for Minimal Reflected LightRe ectance greatly decreasedSunlight

Reason

2

1,000 cd/m2 Ultra High-brightness TFTcandela (cd/m2)1000

Brightness greatly increased

500 350

[ AGP-3300U]

[ Standard model ]

CG simulation

[ AGP-3300U]

External light is re ected!

[ Standard model ]

CG simulation

AGP-3300U AGP-3300T

GP-2300T

The anti-re ective design minimizes re ected light in well-lighted locations. The bene t is easy to read sharp and clear screens in di cult-to-view locations.

The 1,000 cd/m2 (measured on TFT color LCD) ultra high-brightness TFT features a long backlight lifetime of 75,000 hours. This reduces backlight maintanenance costs and service times.* Use as directed in General Speci cations on the rear of this lea et.

www.profaceamerica.com

AGP-3300U-D24Performance Speci cationsDisplay Type Display Colors Resolution Backlight Dot Pitch E ective Display Area Brightness Brightness Control Backlight Service Life Application Memory Backup Memory Variable Area Program Area Number of Steps TFT Color LCD (Ultra high-brightness) 65,536 colors (No blink)*1 16,384 colors (3-speed blink) 320 x 240 pixels (QVGA) CCFL (User nonreplaceable. Factory replacement required.) W0.36 x H0.36 mm [W0.01 x H0.01 in.] W117.2 x H88.4 mm [W4.16 x H3.48 in.] Voltage Endurance 1,000 cd/m2 (Measured on TFT Color LCD) 8 Levels (Adjusted with the touch panel) over 75,000 hrs. FLASH EPROM 6 MB *2 SRAM 320 KB (Lithium battery for backup memory) *3 SRAM 64 KB (Uses lithium battery) *3 FLASH EPROM 132 KB Equivalent to 15,000 steps Resistive Film (analog) 1,024 x 1,024 RS-232C/RS-422/RS-485*5, Asynchronous Transmission, Data Length: 7 bit/8 bit, Serial (COM1) Parity: None, Odd or Even, Stop Bit: 1 bit/2 bit, Data Transmission Speed: 2,400 bps to 115.2 Kbps, Connector: D-sub 9 pin(plug) RS-422/RS-485, Asynchronous Transmission, Data Length: 7 bit/8 bit, Parity: None, Odd or Even, Stop Bit: 1 bit/2 bit, Data Transmission Speed: 2,400 bps to 115.2 Kbps, 187.5 kbps(MPI), Connector: D-sub 9 pin(socket) IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular Jack (RJ-45) x 1 Communication Expansion Unit x 1 Conforms to USB1.1. (TYPE-A conn.) x 1, Power Supply Voltage: DC5V5%, Output Current: 500 mA (max.), Communication Distance: 5 m (max.) Compact Flash Card Slot (TYPE-II) x 1 Noise Immunity Electrostatic Discharge Immunity Grounding Structure *7 External Dimensions Weight Approx. Cooling Method *4 Insulation Resistance Ambient Operating Temperature Storage Temperature Ambient Humidity Storage Humidity Pollution Degree Atmosphere Air Pressure Vibration Resistance (altitude range) Vibration Resistance International Safety Standards Conforming Standards Input Voltage Rated Voltage Allowable Voltage Drop Power Consumption

Speci cationsGeneral Speci cations,(Under application)

EN 55011 Class A, EN 610000 - 6 - 2 DC24V DC19.2 to 28.8V 5 ms max. 26 W max. AC1,000V 20 mA for 1 minute (Between charging and FG terminals) DC500V 10 M (min.) (Between charging and FG terminals) 0 to 50 *6 C -20 to +60 C 10 to 90% RH (Wet bulb temperature: 39 max. - no condensation) C 10 to 90% RH (Wet bulb temperature: 39 max. - no condensation) C For use in Pollution Degree 2 environment Free of corrosive gases 800 to 1,114 hPa (2,000 meters max.) IEC/EN61131-2 compliant 5 to 9 Hz Single Amplitude 3.5 mm [0.14 in.] 9 to 150 Hz Fixed Acceleration: 9.8 m/s2 X, Y, Z Directions for 10 cycles (100 minutes) Noise Voltage: 1,000 Vp-p Pulse Duration: 1 s Rise Time: 1 ns (via noise simulator) Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3) Protective grounding:Grounding resistance of 100 , 2 mm2 or thicker wire, or your country's applicable standard. (Same for FG and SG terminals) IP65f (On the front panel when properly installed in an enclosure) W167.5 mm x H135 mm x D59.5 mm[W6.59 x H5.31 x D2.34 in.] 1.0 kg [2.2 lb] max. (unit only) Natural Air Circulation

*1 Changing the Colors setting to "65,536 colors" will disable the blinking feature on all screens in your project. If you wish to use the blinking feature, select 16,384 colors. *2 Capacity available for user application *3 A Lithium battery's service life is over 10 years at 40 or lower, over 4.1 years at 50 or lower, and C C over 1.5 years at 60 or lower. When used for backup, data can be detained for approximately 100 days C with a fully charged battery or approximately 6 days with a half-charged battery.

+ 0.04 -0

]

7

167.5[6.59]135[5.31]

5[0.20]

8123[4.84]

13[0.51]

29[1.14]

1 123.5 + 04.86 -[

Control Memory Interfaces

Touch Panel Type Touch Panel Resolution

Serial (COM2)

Ethernet (LAN) Communication Expansion Unit 1 USB CF Card

*4 The number of steps can be increased to 60,000 in the software. However, this reduces the internal memory capacity (for screen data) by 1MB. *5 RS-232C and RS-422/RS-485 are software switchable. *6 "Operating temperature" refers to the temperature inside the mounting enclosure and on the front panel. *7 The performance of the product cannot be guaranteed for every environment.

Supporting Screen Editor Software: GP-Pro EX V2.51 or later (For the detail on the upgrade from the previous version, please contact our sales o ce closest to your o ce.)

External Dimensions

155.5[6.12] 59.5[2.34]

Cable Attachment Dimensions

Panel Cutout1 156 + 0[6.14 + 0.04 -0

]

Panel thickness 1.6[0.06] to 5.0[0.20]Compatible panel cutout dimensions with previous models (156 x 123.5) GP-377 (R) / GP-230*

4R3 or le ss

1 2

9 5 6 4

Part Names

Unit: mm[in.]2Touch Panel

3

11

24[0.94]

1 Display 4 6 8

10

10 11

3 Status LED 5 Power Plug Connector Serial Interface (COM1) 7 Serial Interface (COM2) Ethernet Interface (LAN) 9 Expansion Unit Interface USB Interface (Host) CF Card Cover (CF Card Interface, DIP Switches) CF Card Access LED

* Attaching a Protective Cover reduces the e ectiveness of preventing the re ection of external light. A Screen Protection Sheet is not supported with AGP-3300U. For details of other options and system design, refer to the GP-3000 Series Hardware Manual.

Save Today! Ask us about our rst time buyer Promotion2009.Pro-face America. All rights reserved.

Screen & Logic Development Software

Ver.

2.7May 2011

Provides easy video image handling

Supports new Pro-face products

New Tools for Developers

"Exceed the boundaries of traditional screen creation."World Wide Support Allows for easy conversion of screen data assets

New possibilities with HMI and Industrial PCs

www.profaceamerica.com

Use the power of the Pro-face GP-Pro EX development software to create intuitive, user friendly operator interface projects fastEasy Camera Integration adds to Safety, Security and VisibilityIndustrySemiconductor Water Treatment Transfer Electronics Machine Tools

Industry

Automobile

Food and Beverage

Pharmaceuticals

Medical Care

Packaging

Do you take extra time and additional work to investigate causes of downtime on site?CameraViewer EX allows you to view live images or record and playback video for root cause analysis.Camera-Viewer EX allows you to check, record and play videos on PC at office in real time from cameras connected to GP.

Does thethe setting adjustmentan inspection/vision Does setting adjustment of of an inspection camera require additional work?In combination with a COGNEX In-Sight vision system *, the settings can be changed when watching images from the cameras on a GP unit on site.* GP3000 Series supports In-Sight Micro series and In-Sight 5000 series.

Ethernet

The video is saved on PC HDD, enabling you to record a long time.

Configuration

Images

Office Even when an NG unit is detected in inspection, the inspection camera can be adjusted. You can also check the images from the camera on GP screen * ** Only one screen is required to see images from up to 3 cameras. Up to 16 cameras can be connected to GP. * The display position (X/Y), exposure time, focuse, lighting and brightness can be specified on GP.

LAN

No need of HMI or PC dedicated to a camera on site. Only oneHMI integrates functions to display the video images of inspection and operate equipment. It also provides high maintenanceability.

Before Production site

Specific monitor or PC HMI

AfterGP

* The purchase of the license for Camera-Viewer EX is required. * Only the built-in video input interface of the Multimedia Class is supported. * Real time checking may be a delay of about one second to display an image on PC at office.

* This is available for the models with Ethernet port except for GP-4104, GP-3200 and GP-3300 Rev.3 or lower.

Communicating with multiple devices on only one screenIndirect Controller addressing allows the creation of a single screen to cycle through data from multiple connected devices.

BeforeEach device required one screen for its operation.

AfterData from multiple devices can be displayed on the same screen even when switching the communications of the devices.

Screen for Dev