Noise (EA Level Reviews) General requirements Legislation Regulation HUD’s noise regulations protect residential properties from excessive noise exposure. HUD encourages mitigation as appropriate. Noise Control Act of 1972 General Services Administration Federal Management Circular 75‐ 2: “Compatible Land Uses at Federal Airfields” Title 24 CFR 51 Subpart B References https://www.hudexchange.info/programs/environmental‐review/noise‐abatement‐and‐ control 1. What activities does your project involve? Check all that apply: New construction for residential use NOTE: HUD assistance to new construction projects is generally prohibited if they are located in an Unacceptable zone, and HUD discourages assistance for new construction projects in Normally Unacceptable zones. See 24 CFR 51.101(a)(3) for further details. Continue to Question 2. Rehabilitation of an existing residential property NOTE: For major or substantial rehabilitation in Normally Unacceptable zones, HUD encourages mitigation to reduce levels to acceptable compliance standards. For major rehabilitation in Unacceptable zones, HUD strongly encourages mitigation to reduce levels to acceptable compliance standards. See 24 CFR 51 Subpart B for further details. Continue to Question 2. A research demonstration project which does not result in new construction or reconstruction, interstate, land sales registration, or any timely emergency assistance under disaster assistance provisions or appropriations which are provided to save lives, protect property, protect public health and safety, remove debris and wreckage, or assistance that has the effect of restoring facilities substantially as they existed prior to the disaster Based on the response, the review is in compliance with this section. Continue to the Worksheet Summary below. None of the above Based on the response, the review is in compliance with this section. Continue to the Worksheet Summary below.

Transcript of Noise (EA Level Reviews) - files.hudexchange.info · of Notice CPD-16-19. Mortgagor must certify...

Noise (EA Level Reviews) 

 

General requirements  Legislation  Regulation 

HUD’s noise regulations protect 

residential properties from 

excessive noise exposure. HUD 

encourages mitigation as 

appropriate. 

Noise Control Act of 1972 

 

General Services Administration 

Federal Management Circular 75‐

2: “Compatible Land Uses at 

Federal Airfields” 

Title 24 CFR 51 

Subpart B 

References 

https://www.hudexchange.info/programs/environmental‐review/noise‐abatement‐and‐control 

 

1. What activities does your project involve? Check all that apply:  

☒ New construction for residential use   NOTE: HUD assistance to new construction projects is generally prohibited if they are located in an Unacceptable zone, and HUD discourages assistance for new construction projects in Normally Unacceptable zones.  See 24 CFR 51.101(a)(3) for further details.  Continue to Question 2.  

 

☐ Rehabilitation of an existing residential property   NOTE: For major or substantial rehabilitation in Normally Unacceptable zones, HUD encourages mitigation to reduce levels to acceptable compliance standards.  For major rehabilitation in Unacceptable zones, HUD strongly encourages mitigation to reduce levels to acceptable compliance standards.  See 24 CFR 51 Subpart B for further details.    Continue to Question 2.   

☐ A research demonstration project which does not result in new construction or reconstruction, interstate, land sales registration, or any timely emergency assistance under disaster assistance provisions or appropriations which are provided to save lives, protect property, protect public health and safety, remove debris and wreckage, or assistance that has the effect of restoring facilities substantially as they existed prior to the disaster  Based on the response, the review is in compliance with this section. Continue to the Worksheet Summary below.  

☐ None of the above  Based on the response, the review is in compliance with this section. Continue to the Worksheet Summary below. 

2. Complete the Preliminary Screening to identify potential noise generators in the 

vicinity (1000’ from a major road, 3000’ from a railroad, or 15 miles from an airport).   

Indicate the findings of the Preliminary Screening below:  

☐ There are no noise generators found within the threshold distances above.  

 Based on the response, the review is in compliance with this section. Continue to the Worksheet Summary below. Provide a map showing the location of the project relative to any noise generators.     

☒ Noise generators were found within the threshold distances. 

 Continue to Question 3.   

3. Complete the Noise Assessment Guidelines to quantify the noise exposure. Indicate 

the findings of the Noise Assessment below: 

☐ Acceptable:  (65 decibels or less; the ceiling may be shifted to 70 decibels in circumstances described in §24 CFR 51.105(a))  Indicate noise level here:     Based on the response, the review is in compliance with this section. Continue to the Worksheet Summary below. Provide noise analysis, including noise level and data used to complete the analysis.    

 

☒ Normally Unacceptable:  (Above 65 decibels but not exceeding 75 decibels; the floor may be shifted to 70 decibels in circumstances described in 24 CFR 51.105(a))  

 Indicate noise level here:    

If project is rehabilitation:   Continue to Question 4. Provide noise analysis, including noise level and data used to complete the analysis.    If project is new construction:  Is the project in a largely undeveloped area1? 

☒ No   Continue to Question 4. Provide noise analysis, including noise level and data used to complete the analysis, and any other relevant information.        

☐ Yes  

                                                            1 A largely undeveloped area means the area within 2 miles of the project site is less than 50 percent developed with urban uses and does not have water and sewer capacity to serve the project. 

  73.2 

   

Your project requires completion of an Environmental Impact Statement (EIS) pursuant to 51.104(b)(1)(i). Elevate this review to an EIS‐level review.  

 

☐ Unacceptable:  (Above 75 decibels)  

Indicate noise level here:    

If project is rehabilitation:  HUD strongly encourages conversion of noise‐exposed sites to land uses compatible with high noise levels. Consider converting this property to a non‐residential use compatible with high noise levels.  

 Continue to Question 4. Provide noise analysis, including noise level and data used to complete the analysis, and any other relevant information.       

 If project is new construction:  Your project requires completion of an Environmental Impact Statement (EIS) pursuant to 51.104(b)(1)(i). You may either complete an EIS or provide a waiver signed by the appropriate authority. Indicate your choice:  

☐ Convert to an EIS  Provide noise analysis, including noise level and data used to complete the analysis.   Continue to Question 4.      

☐ Provide waiver   Provide an Environmental Impact Statement waiver from the Certifying Officer or the Assistant Secretary for Community Planning and Development per 24 CFR 51.104(b)(2) and noise analysis, including noise level and data used to complete the analysis.        Continue to Question 4.     

            

   

4. HUD strongly encourages mitigation be used to eliminate adverse noise impacts. Explain in detail the exact measures that must be implemented to mitigate for the impact or effect, including the timeline for implementation. This information will be automatically included in the Mitigation summary for the environmental review.  

 

☒ Mitigation as follows will be implemented:         

      Provide drawings, specifications, and other materials as needed to describe the project’s noise mitigation measures. Continue to the Worksheet Summary.  

  

☐ No mitigation is necessary.   Explain why mitigation will not be made here:  

       

  Continue to the Worksheet Summary.               

Based on the proposed site plan provided to ICG, the 10‐year projected DNL value for all noise sources is 74.5 dB. Pursuant to 24 CFR51.101(a)(4), the composite DNL 74.5 dB is “normally unacceptable”; however, it should not result in the denial of HUD support for an otherwise acceptable proposed facility. The requirements set out in Section 51.104(a) are designated to ensure that interior levels do not exceed the established 45 dB level. The calculated projected exterior noise value is 74.5 dB; therefore, the combined wall, window and door STC ratings will need to reduce the interior noise level by at least 22.1 dB. 

   

Worksheet Summary  Compliance Determination Provide a clear description of your determination and a synopsis of the information that it was based on, such as:  

Map panel numbers and dates 

Names of all consulted parties and relevant consultation dates 

Names of plans or reports and relevant page numbers 

Any additional requirements specific to your region                                Are formal compliance steps or mitigation required?  

☐ Yes 

☒ No  

 

The Subject Property is located within 1000 feet of a major highway or busy road as defined in CF 1 of Handbook 1390.2. The Subject Property is located +/- 535’ southwest of Interstate 20. Based on Google Maps the nearest military airport (MacDill Air Force Base) is +/- 12 miles and the nearest civilian airport is +/- 18 miles (Tampa International Airport) from the Project site. According to the National Transportation Noise Map the current noise exposure to the proposed project is decibels including the two airports within 15 miles from the project is below 35 decibels. No railroads are within 3,000 feet of the proposed project. No additional potential noise generators were identified within the noise thresholds of the proposed project. Florida Department of Transportation 2016 traffic count data was utilized for the analysis with a 3% standard annual increase in traffic per year projected for 10 years. Default nighttime percentages (15%) and road grade (2%) were utilized per HUD Guidelines. Noise calculations have been performed utilizing the HUD online dNL calculator. Based on the proposed site plan provided to ICG, the 10-year projected DNL value for all noise sources is 74.5 dB. Pursuant to 24 CFR51.101(a)(4), the composite DNL 74.5 dB is “normally unacceptable”; however, it should not result in the denial of HUD support for an otherwise acceptable proposed facility. The requirements set out in Section 51.104(a) are designated to ensure that interior levels do not exceed the established 45 dB level. The calculated projected exterior noise value is 74.5 dB; therefore, the combined wall, window and door STC ratings will need to reduce the interior noise level by at least 22.1 dB. STC ratings as applicable related to buildings that fall within the 1,000’ threshold of noise exposure. Appended.  The proposed project design for the noise impaired site includes exterior patios and balconies. Please provide a complete Noise Operations and Maintenance Plan that meets all requirementsof Notice CPD-16-19. Mortgagor must certify that the O&M plan will be maintained throughout the term of the insured mortgage. Noise Operations and Maintenance Plan is appended. 

 

 

 

 

 

 

 

 

 

 

Vehicle Type Cars Medium Trucks Heavy Trucks

Effective Distance 363 363 363

Distance to Stop Sign

Average Speed 70 70 70

Average Daily Trips (ADT) 104,835 10,845 4,820

Night Fraction of ADT 15 15 15

Road Gradient (%) 2

Vehicle DNL 67.6 57.8 71.6

SITE DNL 73.2

Vehicle Type Cars Medium Trucks Heavy Trucks

Effective Distance 363 363 363

Distance to Stop Sign  

Average Speed 70 70 70

Average Daily Trips (ADT) 140889 14575 6478

Night Fraction of ADT 15 15 15

Road Gradient (%) 2

Vehicle DNL 68.9 59.1 72.8

SITE DNL 74.5

Interstate 75

Interstate 75 - 10 YEAR PROJECTIONS Calculated at 3% increase per year

 

sherry
Oval

Centerline of I‐75 

 

 

 

 

 

 

Tree Line along I‐75 – Noise Break 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The swimming pool was not included in the measurements as the noise source is blocked by the Clubhouse and tenant 

buildings. The only area that is unblocked from the noise source is an area between buildings 5 & 6 which exceeds the 

1,000’ threshold. 

 

Building 5 

 

Building 4 

 

Building 3 

 

Building 6 

 

Building 7 

 

Building 8 

 

Building 9 

 

Clubhouse 

 

 

 

 

 

 

Noise/STC Ratings

Shadetree Apartments STC Overview

BuildingDistance

(feet) dBAttenuation

RequiredAttenuation

AchievedAdditional Attenuation

Required? Comments

1 1045 N/A N/A N/A No Exceeds noise threshold distance

2 802 69.3 27.3 32.61 NoUtilized front and rear of building. Side protected by building 3

3 493 72.5 30.5 32.61 NoUtilized front and rear of building. Side protected by building 4

4 363 74.5 32.5 33.82 No Utilized front and 2 sides of building

5 375 74.3 32.3 33.82 No Utilized front and 2 sides of building

6 457 73 31 33.06 No Utilized front, back and 1 side of building

7 637 70.8 28.8 33.38 No Utilized rear and side of building

8 849 69 27 33.38 No Utilized front and side of building

9 763 69.7 27.7 33.38 No Utilized front and side of building

10 992 68 26 33.38 No Utilized rear and side of building

11 1263 N/A N/A N/A No Exceeds noise threshold distance

12 1396 N/A N/A N/A No Exceeds noise threshold distance

13 1267 N/A N/A N/A No Exceeds noise threshold distance

Clubhouse 903 68.6 26.6 37.71 No Utilized rear of building

Swimming Pool 1001 N/A N/A N/A No Exceeds noise threshold distance

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 2

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

69.3

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

10500 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

10,500 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

96 15 26

8 12 20

0 0

Door Construction Detail Quantity Sq Ft/Unit STC

8 21 27

14 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 10500 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

-- select window --

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 104 ft² 14.63%

Doors: 22 462 ft² 4.4%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 69.3

Combined attenuation for wall component: 32.61 dB

Required attenuation: 27.299999999999997

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 3

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

72.5

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

10500 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

10,500 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

96 15 26

8 12 20

0 0

Door Construction Detail Quantity Sq Ft/Unit STC

8 21 27

14 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 10500 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

-- select window --

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 104 ft² 14.63%

Doors: 22 462 ft² 4.4%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 72.5

Combined attenuation for wall component: 32.61 dB

Required attenuation: 30.5

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 4

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

74.5

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

10650 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

10,650 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

66 15 26

10 12 20

0 0

Door Construction Detail Quantity Sq Ft/Unit STC

6 21 27

7 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 10650 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

-- select window --

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 76 ft² 10.42%

Doors: 13 273 ft² 2.56%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 74.5

Combined attenuation for wall component: 33.82 dB

Required attenuation: 32.5

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 5

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

74.3

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

10650 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

10,650 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

66 15 26

10 12 20

0 0

Door Construction Detail Quantity Sq Ft/Unit STC

6 21 27

7 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 10650 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

-- select window --

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 76 ft² 10.42%

Doors: 13 273 ft² 2.56%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 74.3

Combined attenuation for wall component: 33.82 dB

Required attenuation: 32.3

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 6

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

73

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

13200 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

13,200 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

99 15 26

11 12 20

6 15 26

Door Construction Detail Quantity Sq Ft/Unit STC

9 21 27

14 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 13200 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

3x5ft double hung

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 116 ft² 12.93%

Doors: 23 483 ft² 3.66%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 73

Combined attenuation for wall component: 33.06 dB

Required attenuation: 31

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 7

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

70.8

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

7950 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

7,950 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

57 15 26

7 12 20

0

Door Construction Detail Quantity Sq Ft/Unit STC

5 21 27

7 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 7950 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

-- select window --

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 939 ft² 11.81%

Doors: 12 252 ft² 3.17%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 70.8

Combined attenuation for wall component: 33.38 dB

Required attenuation: 28.799999999999997

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 8

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

69

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

7950 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

7,950 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

57 15 26

7 12 20

0

Door Construction Detail Quantity Sq Ft/Unit STC

5 21 27

7 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 7950 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

-- select window --

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 939 ft² 11.81%

Doors: 12 252 ft² 3.17%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 69

Combined attenuation for wall component: 33.38 dB

Required attenuation: 27

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 9

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

69.7

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

7950 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

7,950 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

57 15 26

7 12 20

0

Door Construction Detail Quantity Sq Ft/Unit STC

5 21 27

7 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 7950 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

-- select window --

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 939 ft² 11.81%

Doors: 12 252 ft² 3.17%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 69.7

Combined attenuation for wall component: 33.38 dB

Required attenuation: 27.700000000000003

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Building 10

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

68

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

7950 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

7,950 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

57 15 26

7 12 20

0

Door Construction Detail Quantity Sq Ft/Unit STC

5 21 27

7 21 26

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 7950 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

3x4ft jalousie

-- select window --

3x7ft solid-core wood

3x7ft wood French

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 939 ft² 11.81%

Doors: 12 252 ft² 3.17%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 68

Combined attenuation for wall component: 33.38 dB

Required attenuation: 26

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Home (/) > STraCAT

Sound Transmission Classification Assessment Tool (STraCAT)

Part I - Description

Project

Shadetree Clubhouse

Sponsor/Developer

Framework Group

Location

Ruskin, FL

Prepared by

ICG

Noise Level

68.6

Date

Primary Source(s)

I-75

Part II - Wall Components

Wall Construction Detail Area STC

2300 49

2017-06-09

Stucco

Page 1 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

0 0

0 0

2,300 Sq. Feet 49

Window Construction Detail Quantity Sq Ft/Unit STC

6 15 26

7 30 38

0

Door Construction Detail Quantity Sq Ft/Unit STC

2 21 26

0

0 0

Part III - Results

Wall Statistics

Stat Value

Area: 2300 ft²

Wall STC: 49

-- select wall --

-- select wall --

3x5ft double hung

6x5ft picture w/storm sash

-- select window --

3x7ft wood French

-- select door --

-- select door --

Page 2 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Print

p

Aperture Count Area % of wall

Windows: 300 ft² 13.04%

Doors: 42 ft² 1.83%

Evaluation Criteria

Criteria Value

Noise source sound level(dB): 68.6

Combined attenuation for wall component: 37.71 dB

Required attenuation: 26.599999999999994

Do Wall components meet requirements? Yes

Page 3 of 3STraCAT - HUD Exchange

6/9/2017https://www.hudexchange.info/stracat/

Maintenance Operations and Maintenance Plan

Operations & Maintenance Plan Shadetree Apartments

Ruskin, Florida

Table of Contents

Overview ....................................................................................................................................... 1

Operations & Maintenance: Building Envelope ............................................................................. 2

Operations & Maintenance: Heating and Cooling ......................................................................... 3

Operations & Maintenance: Domestic Hot Water ......................................................................... 5

Operations & Maintenance: Lighting ............................................................................................. 6

Operations & Maintenance: Miscellaneous ................................................................................... 7

Operations & Maintenance: Sample Checklists ............................................................................ 8

Overview

Equipment information. Maintenance staff should have all manufacturer's instructions and manuals availablein an accessible location. They should be used when operating equipment or performing maintenance. Inaddition, maintenance staff should have a master equipment list available that describes the equipment, itspurpose, how it should be operated, and its maintenance requirements.

Routine maintenance and operations checks. Maintenance should routinely check equipment and systems forproper operation and control settings and perform preventative maintenance on a routine basis. The printablechecklist provides a guide to this process. Equipment manuals and instructions should also be used whenavailable. It is a good idea for maintenance staff to make and follow a schedule of O&M items to make sureoperations checks and maintenance procedures are performed with the recommended frequency.

Record keeping. All O&M checks and procedures should be recorded in an O&M log available to allmaintenance staff. This practice will help ensure that all necessary O&M items are performed and that theyare not duplicated by more than one maintenance staff person. It also provides a record for management.

Training. Maintenance staff should be trained to operate and maintain equipment. When new systems areinstalled, you should make sure the maintenance staff receives training to properly operate and maintain theequipment. The vendor or manufacturer may provide this. In some cases, such as when a complicated heatingsystem or energy management system is installed, you may want to consider a maintenance contract for thatequipment.

Accountability. Maintenance staff should be accountable for ensuring proper O&M. It is generallyrecommended that a single maintenance staff person or engineer be given overall responsibility for the O&Mprogram. Having a single person in charge helps create an incentive for good O&M and it generally results ina better-run O&M program. If necessary, it may be more appropriate to divide responsibility among more thanone person.

Shadetree Apartments

Operations & Maintenance: Building Envelope

Caulk frames and openings. Inspect at tenant request, tenant unit turnover or minimum annually in each tenant unit. Air infiltration can occur around the frames of doors, windows and skylights, resulting in heat loss in the winter and heat gain in the summer. Caulking these areas can save on heating/cooling costs and increase resident comfort. Existing caulking that is cracked or deteriorating should be scraped out and replaced with new caulk.

Patch holes in the building envelope. Holes in the walls, roof, foundations, doors, and vestibules allow air infiltration, resulting in heat loss in the winter and heat gain in the summer. These holes should be patched to save on heating/cooling costs and to increase resident comfort. Qualified personnel should repair holes in accordance with building construction type.

Repair cracked windowpanes. Inspect at tenant request, tenant unit turnover or minimum annually in each tenant unit. Broken windowpanes allow air infiltration, resulting in heat loss in the winter and heat gain in the summer. Repairing them will save on heating/cooling costs and increase resident comfort. Broken panes should be repaired only as a temporary measure before the window can be replaced.

Weatherstrip windows and doors. Inspect at tenant request, tenant unit turnover or minimum annually in each tenant unit. Weatherstripping reduces infiltration around windows and doors, particularly if storm windows and doors are not present. By helping to keep warm air inside during the winter and cool air inside during the summer, weatherstripping saves energy and increases resident comfort. Flexible rubber or plastic strips can be installed to seal any gap between the edge of an operable window and its sash. Existing deteriorated weatherstripping should replaced upon observation.

Install storm windows and doors at the beginning of the heating season. In developments that have storm windows and storm doors, maintenance staff should make sure that the proper panels are in place at the beginning of the heating season.

Open and close shades in common areas. In the winter, blinds or curtains in common areas such as community rooms, lobbies, and offices should be closed at night to keep warm air inside, and open on sunny days to let the sun's rays help heat the room. In the summer, they should be closed during the day to minimize heat gain.

Lower awnings in the summer. In developments that have awnings, maintenance staff should make sure they are lowered in the summertime to reduce heat.

Check automatic door closing mechanisms. Inspect at tenant request, tenant unit turnover or minimum annually in each tenant unit. Automatic door closers on exterior doors should be adjusted so that doors close quickly and completely.

Shadetree Apartments

Operations & Maintenance: Heating and Cooling Heating systems in individual dwelling units

Turn off pilot light in summer. For gas boilers and furnaces without an electronic ignition, the pilot lights should be shut off at the end of the heating season and relit at the start of the next beating season. During non-heating months, a lit pilot light on a gas furnace, boiler, or space heater is a source of energy waste. Installation of electronic ignition, which automatically shuts off and relights the pilot light according to demand, should be considered.

Clean and adjust burners. Burners on gas or oil furnaces or boilers should be regularly cleaned and adjusted to ensure maximum efficiency. When burners have clogged openings or are in need of adjustment, they are less efficient. A burner is in need of adjustment if any of the following applies: the flame edge touches the combustion chamber, the tip of the flame is orange, fiery droplets are present in the flame, or there is smoke above the chimney. On oil burners, a microscreen filter added at the burner may reduce the chances of clogging.

Change/clean filters on forced-air systems. Filters on individual forced-air systems should be changed or cleaned bi-monthly by maintenance staff. Disposable filters should be replaced using a type recommended by the equipment manufacturer, and permanent filters should be cleaned according to manufacturer's instructions. Clean air filters improve the performance of heating systems by removing impurities from the supply air. When the filter is dirty, the fan requires more energy to force air through the clogged filter.

Inspect equipment for worn or damaged parts. Periodic inspection should be made to identify worn or damaged gaskets, casings, linkages, and other parts of stationary and moving equipment. Worn or broken parts should be repaired or replaced with parts specified by the manufacturer.

Lubricate equipment. Equipment such as blowers, motors, fans, and bearings should be lubricated on a regular basis, according to the manufacturer's manual and using the lubricant specified. Proper lubrication reduces wear and tear on equipment and enhances its performance.

Heat Pumps

Keep air registers open. Air registers that provide heating and cooling to conditioned spaces should be kept in the open position with heat pump systems. Closing or blocking off registers can impair the system's performance.

Lubricate fan motors and adjust blowers and drive belt. Fan motors should be lubricated and the blower unit and drive belts adjusted according to manufacturer's instructions.

Clean coils. Indoor heat exchanger coils should be cleaned with a vacuum or brush when dirt builds up. Outdoor coils must be free from shrubs or other items that may impede air flow and should be cleaned periodically with a garden hose.

Shadetree Apartments

Cooling

Turn off cooling systems in unoccupied common areas. Air conditioning should be turned off in unoccupied areas and in office areas after hours.

Clean or change air filters. Air filters should be cleaned or changed monthly during the cooling season, depending on whether they are disposable. Air filters are located in the air handler, behind the grille of return registers, or adjacent to the blower in the main return air duct. Dirty filters block air flow and decrease cooling efficiency.

Clean evaporator coils. Evaporator coils should be cleaned every three to five years. Dirty evaporator coils result in inefficient cooling and shorten the life of the blower and compressor. Evaporative coils in packaged air conditioners and window units can be reached by removing an access panel. Coils can be cleaned with a bristle brush to loosen and remove dirt.

Clean condenser coils. The condenser should be cleaned whenever dirt accumulates. If the condenser gets too dirty, the compressor can burn out. Condensing coils can be cleaned with a bristle brush to remove loose dirt. A garden hose can be used to flush the dirt out from the inside out. Caution should be used to avoid damaging the coils.

Clean blower. Blowers should be cleaned when dirt accumulates on blower blades because dirt reduces their ability to blow air over the condenser coils. Before cleaning the blower, the power should be shut off to the air conditioner at the circuit breaker or main switch. To access the blower, a plate in the blower housing may need to be removed. The blower can be cleaned with a brush and a vacuum cleaner.

Shadetree Apartments

Operations & Maintenance: Domestic Hot Water

Lower water temperature. Domestic hot water should generally be provided at about 120 degrees F. If water in dwelling units is hotter than 120 degrees, the water temperature can be lowered to save energy. Individual hot water heaters should be set at 120 degrees, while in central systems, the temperature should be adjusted so that 120-degree water is provided to the dwelling units.

Repair all leaks. Maintenance staff should periodically inspect all apartments and repair leaky faucets. One leaking faucet can waste more than 1,000 gallons per year as well as 500,000 Btus necessary to heat it. In addition, staff should inspect the entire distribution system, valves, and pumps.

Insulate domestic hot water pipes. All domestic hot water circulation pipes should be insulated with one-half inch of insulation to reduce heat loss. Older domestic hot water heater tanks also should be insulated.

Turn off domestic hot water supply to areas that do not need it. Hot water supplies to areas such as utility rooms, boiler rooms, and other rooms should be turned off. Shut off should occur as near to the hot water heater as possible to reduce piping energy losses.

Reduce water pressure. In buildings where the water pressure is higher than necessary, a pressure regulator should be installed to reduce pressure to the minimum level required by local code. High water pressure results in high flow rates and water waste. It also can increase wear and tear on plumbing equipment and result in leaks.

Flush tank-type water heaters. Tank-type water heaters (both gas and electric) should be flushed periodically to remove sediment. The accumulation of sediment on the bottom of the tank results in inefficient operation of the water heater. The water should be drained into a bucket until it runs clear.

Clean/adjust burners on gas and oil water heaters. Burners on gas- and oil-fired domestic hot water heaters should be cleaned and adjusted annually for combustion efficiency. The buildup of soot or other residue decreases combustion efficiency. If necessary, qualified staff should adjust the flame in accordance with the manufacturer's manual.

Check electrodes on electric water heaters. Electrodes on electric water heaters should be checked for scale buildup. Removing scale buildup will increase heat transfer.

Shadetree Apartments

Operations & Maintenance: Lighting

De-lamp overlit areas. In overlit areas, some fluorescent and/or incandescent lamps should be removed to reduce electricity use. In many areas, illumination levels can be reduced by as much as 50 percent while still satisfying minimum lighting requirements. General guidelines for de-lamping fluorescent lamps are: for two-lamp fixtures, remove one lamp in each fixture or both tubes in alternate fixtures; for three-lamp fixtures, remove the lamp in the middle; for four-lamp fixtures, the ballast associated with the two inner tubes should be disconnected. Incandescent lamps can be removed wherever minimum lighting levels still can be maintained without them. Any de-lamping should maintain minimum light levels as required by code and security requirements.

Keep energy-efficient lamps in stock for replacement. Once efficient lighting is installed, maintenance staff need to ensure that these types of lamps are in stock to avoid re-installation of less-efficient lamps. Where cost-effective, energy-saving fluorescent lamps should replace standard incandescent lamps.

Clean lighting fixtures. Lamps, fixtures, reflectors, and diffusers should be regularly cleaned because dirty lighting fixtures transmit less light, decreasing lighting efficacy. Caution should be exercised when cleaning all electrical fixtures. The current should be turned off before cleaning fixtures, and fixtures should be thoroughly dry before turning the current back on. Wiring and connections should not be disturbed.

Clean or paint walls. Walls should be kept clean to maximize the brightness of a room. When new paint is needed, a non-glossy white paint should be selected.

Check timers on exterior lighting. Timers on exterior lighting should be checked to ensure they are set properly and that the time is set correctly.

Shadetree Apartments

Operations & Maintenance: Miscellaneous

Calibrate checkmeters. Checkmeters should be reviewed every few years to ensure accuracy. The accuracy can be checked by comparing the consumption from the master meter with the consumption from all of the checkmeters. If they are not the same, then the checkmeters should be re-calibrated (adjusted for accuracy).

Check for and repair water leaks. Staff should check the distribution lines on the street and the service lines on the property. The valve between the distribution line and the sewer line should also be checked. Residents should be encouraged to report water leaks on faucets, showers, tubs, toilets, or garden hoses. Any water leaks inside or outside the buildings should repaired immediately.

Reduce ventilation rates. Outside air used for ventilation must be heated in the winter, and, in buildings with air conditioning, cooled in the summer. When the amount of outside air taken into a building exceeds the amount required by code, ventilation rates can be reduced to save energy.

Reduce the amount of exhausted air. In buildings with an air exhaust system, air that is exhausted must be replaced by the air intake system or by air infiltrating into the building. Incoming air must be heated in the winter, and, in buildings with air conditioning, cooled in the summer. Reducing the amount of exhausted air can save energy by reducing the need to heat or cool this air. The exhaust system should be operated only for short periods at a time, when exhaust needs are greatest (for example, when most residents are cooking). Check local codes for minimum exhaust air requirements. Exhaust air volume should be slightly lower than the amount of air being supplied to the building through mechanical ventilation and natural infiltration.

Check refrigerators for proper door closure. Refrigerators that do not properly close waste electricity and should be repaired. If repair is not possible, the refrigerator should be replaced.

Shadetree Apartments

Operations & Maintenance: Sample Checklists

Operations & Maintenance Checklist

BUILDING ENVELOPE

□ Caulk frames and openings

□ Patch holes in the building envelope

□ Repair cracked windowpanes

□ Weatherstrip windows and doors

□ Install storm windows and doors atthe beginning of the heating season

□ Remove unit air conditioners in thewinter

□ Open and close shades in commonareas

□ Lower awnings in the summer

□ Check automatic door closingmechanisms

HEATING and COOLING

Heating systems in individual dwelling units

□ Turn off pilot light in summer

□ Clean and adjust burners

□ Change/clean filters on forced-airsystems

□ Inspect equipment for worn ordamaged parts

□ Lubricate equipment

Central boilers and furnaces

□ Turn off pilot light in summer

□ Clean and adjust burners

□ Check and adjust fuel-to-air ratios

□ Calibrate and adjust controls

□ Clean fireside of boiler or furnace

□ Remove scale buildup on heatexchanger and waterside of boiler

□ Operate only as many boilers asneeded at one time

□ Clean oil strainers

□ Clean nozzle or rotary cup onburner

□ Preheat fuel oil

Central heating distribution systems

□ Reduce thermostat settings inunoccupied areas

□ Check ductwork for leaks

□ Keep radiators and hot air registersclean and unobstructed

□ Operate vents in hot waterradiators and baseboard units

□ Check and repair air vents andsteam traps

□ Balance steam distribution

□ Lower steam pressure

□ Monitor make-up waterconsumption

□ Replace steam traps

□ Check heating elements, controls,and fans on electric distribution systems

Heat Pumps

□ Keep air registers open

□ Lubricate fan motors and adjustblowers and drive belts

□ Clean coils

Cooling

□ Turn off cooling systems inunoccupied common areas

□ Clean or change air filters

□ Clean evaporator coils

□ Clean condenser coils

□ Clean blower

HUD Office of Public and Indian Housing Public Housing Energy Conservation Clearinghouse

http://www.hud.gov/offices/pih/programs/ph/phecc/index.cfm

Operations & Maintenance Checklist

□ Maintain chillers

□ Maintain evaporative coolers

DOMESTIC HOT WATER SYSTEM

□ Lower water temperature

□ Repair all leaks

□ Insulate domestic hot water pipes

□ Turn off domestic hot water supplyto areas that do not need it

□ Reduce water pressure

□ Flush tank-type water heaters

□ Clean/adjust burners on gas and oilwater heaters

□ Check electrodes on electric waterheaters

LIGHTING

□ De-lamp overlit areas

□ Keep energy-efficient lamps instock for replacement

□ Clean lighting fixtures

□ Clean or paint walls

□ Check timers on exterior lighting

MISCELLANEOUS

□ Calibrate checkmeters

□ Check for and repair water leaks

□ Reduce ventilation rates

□ Reduce the amount of exhausted air

□ Check refrigerators for proper doorclosure

HUD Office of Public and Indian Housing Public Housing Energy Conservation Clearinghouse

http://www.hud.gov/offices/pih/programs/ph/phecc/index.cfm