MAILBOXES - Florida Department of Transportation - Home · Mailboxes shall be located on the...
-
Upload
nguyenthuy -
Category
Documents
-
view
220 -
download
0
Transcript of MAILBOXES - Florida Department of Transportation - Home · Mailboxes shall be located on the...
5. Mailboxes shall be located on the right-hand side of the roadway in the
direction of the delivery route, except on one-way roads and streets where
they may be placed on the left-hand side.
Mailboxes on rural highways shall be set with the roadside face of the box
offset from the edge of the traveled way a minimum distance of the greater
of the following:
(a) Shoulder width plus 8" to 12".
(b) 10’ for ADT over 10,000 vpd.
8’ for ADT 100 to 10,000 vpd.
6’ for ADT under 100 vpd
2’-6" for low speed and ADT under 100 vpd.
When a mailbox is installed within the limits of guardrail it should be placed
behind the guardrail whenever practical.
Mailboxes on curbed highways, roads and streets shall be set with the face
of the box between 6" and 12" back of the face of curb. If the sidewalk
abuts the curb or if an unusual condition exists which makes it difficult or
impractical to install or serve boxes at the curb, the Contractor with
concurrence of the local postal authority may be permitted to install all
mailboxes at the back edge of the sidewalk, where they can be served by
the carrier from the sidewalk.
6. Mailboxes shall be set with the bottom of the box between 42" and 48"
above the mail stop surface, unless the U.S. Postal Service establishes
other height restrictions.
7. No more than two mailboxes may be mounted on a support structure unless
the support structure and mailbox arrangements have been shown to be safe
by crash testing in accordance with NCHRP Report 350 and listed on the
Department’s Qualified Products List (QPL).
Neighborhood Delivery and Collection Box Units (NDCBU) are a specialized
multiple mailbox installation that must be located outside the highway
and street clear zones. The location of NDCBUs is the sole responsibility
of the Postmaster for the delivery route under consideration.
8. Lightweight newspaper receptacles may be mounted below the mailbox on the
side of the support post in conformance with the USPS Domestic Mail Manual.
The mail patron shall be responsible for newspaper receptacle installation
and maintenance.
GENERAL NOTES
1. The location and construction of mailboxes shall conform to the rules and regulations
of the United States Postal Service as modified by this design standard.
2. Mailboxes will not be permitted on Interstate highways, freeways, or other highways
where prohibited by law or regulation.
3. The contractor shall give the Postmaster of the delivery route(s) written notice
of project construction 7 days prior to the beginning of work, with Saturdays,
Sundays and Holidays excluded.
The Contractor shall furnish and install one mailbox in accordance with this design
standard at each mail patron delivery location and maintain the box throughout the
contract period. The Contractor shall apply box numbers to each patron box in
accordance with identification specifications of the Domestics Mail Manual of the
U. S. Postal Service; where local street names and house numbers are authorized by
the Postmaster as a postal address, the Contractor shall inscribe the house number
on the box; if the box is located on a different street from the patrons residence,
the Contractor shall inscribe the street name and house number on the box.
The Contractor shall coordinate removal of the patrons existing mailboxes. Immediately
after installing the new mailboxes the Contractor must notify each "Mail Delivery
Patron" by Certified Mail that removal of the existing mailboxes must be accomplished
in 21 days after receipt of notices. Patrons shall have the option of removing their
existing mailboxes or leaving the mailboxes in place for removal by the Contractor;
removal by the Contractor shall be included in the contract unit price for Mailbox, Each.
The Contractor shall dispose of mailboxes and supports in areas provided by him.
Reuse of existing mailboxes by the Contractor will not be a requirement under any
construction project; however where an existing mailbox meets the design requirements
of this standard and is structurally and functionally sound, the Contractor at his option
may elect to reuse the existing mailbox in lieu of constructing a new mailbox. Any use
of existing mailboxes must be approved by the Engineer.
4. Mailboxes shall be light sheet metal or plastic construction, in traditional style only, and
only in Size 1 as prescribed by the Domestic Mail Manual of the U. S. Postal Service (DMM).
Mailbox production standards, lists of approved manufacturers and suppliers of mailboxes,
design approval and guidance may be obtained by writing to the Rural Delivery Division,
Delivery Service Department, Operations Group, USPS Headquarters, Washington, DC
20260.
9. Wood and steel support posts for both single and double mailbox mountings shall be
embedded no more than 24" into the ground.
Concrete, block, brick, stone or other rigid foundation structure or encasement,
either above or below the shoulder groundline, will not be permitted for mailboxes
on rural highways. On urban roads and streets where mailbox support posts are set
within rigid pavement back of curb, the support posts shall be separated from the
pavement by a minimum of 1" of expansion material.
Support posts shall not be fitted nor installed with surface mount base plates.
10. At driveway entrances mailboxes shall be placed on the far side of the driveway
in the direction of the delivery route.
At intersecting roads mailboxes shall be located 100’ or more from the centerline of
the intersecting road on the far side in the direction of the delivery route, with
the distance increased to 200’ when the route volume exceeds 400 vehicles per day.
11. Wood support posts shall be in conformance with the material and dimensional
requirements of Section 952 and the treatment requirements of Section 955 of
the Standard Specifications.
Steel support posts shall have an external finish equal to or better than two coats of
weather resistant, air dried or baked, paint or enamel. Surface(s) shall be cleaned of
all loose scale prior to finishing. The Postal Service prefers that posts be painted
white, but other colors may be used when approved by the Engineer. When galvanized
posts are used painting is not required.
Mounting brackets, plates, platforms, shelfs and accessory hardware surface finishes
are to be suited to support post finish.
12. Mailboxes shall be paid for under the contract unit price for Mailboxes, Each.
Payment shall be full compensation for boxes, posts and accessory items essential
for installation in accordance with this standard; erection; adjustments to suit
construction needs; and, for identification letters and numbers.
Payment shall be limited to one mailbox per patron address whether the mailbox is
new, reused, salvaged, reset or relocated. Payment shall be per mailbox regardless
of the number of mailboxes per support or grouping arrangement.
The above compensation shall include any work and cost incurred by the contractor
for removal and disposal of existing mailboxes.
There shall be no payment participation for NDCBU furnishing, assembly, installation,
resetting or relocation.
Sheet No.
Index No.
2008 FDOT Design StandardsRevision
532
07/01/07
MAILBOXES
1 of 3
Last
STEEL FLANGED CHANNEL SUPPORT POSTS
POST SPACING
ELEVATION
FRONT VIEW SIDE VIEWFRONT VIEW SIDE VIEW
BOTTOM VIEW
SIDE VIEW
END VIEW
TOP VIEW END VIEW
Platform
Bracket
FLANGED CHANNELFLANGED CHANNEL
Adapter Plate
END VIEWFRONT VIEW
TOP VIEW
2 lb. Per Foot
Flanged Channel
See General Notes
For Finish Requirements
2 Washers, 1 Lockwasher,
#8-32! Slotted Rd. Hd. Bolt3
4
(Stove Bolt) 2 Washers,
Platform
-18! Hex Bolt,21
4
2 Washers, 1 Lockwasher,
16
5
Platform
Bracket 16
5-16! Hex Bolt,
2 Washers, 1 Lockwasher,
3
4
Bracket
#8-32! Slotted Rd. Hd. Bolt3
4
(Stove Bolt) 2 Washers,
-18! Hex Bolt,21
4
2 Washers, 1 Lockwasher,
16
5
Platform
24" M
ax. D
epth
h=
42
" t
o 4
8"
See G
eneral
Note
s
h (Min.) h (Min.)
Ground Line
x 116
1
16
3
13
4 13
413
4 13
4
3 8
1613
21
2 21
2
21
4 21
4
41
2 41
2
17
8
6"
3"
3"
9"
1161
3
1161
3
2161
2161
x3
81
1
4
16
1
Dia.
3"
11
2
1"
2"
3"
Dia. (3 Holes)
32
3
1 2
1"
4"
4" 4"
2"
15"
71
2
21
4 21
4
32
3
3
8x 1
3
8
3
4For Platforms
116
5For Brackets
Nominal
Std. Wt. Pipe
1
2
Note: See General Notes for finish requirements.
SINGLE OR COMBINED WOOD, FLANGED CHANNEL
OR PIPE POST TYPES SHOWN ON THIS INDEX
STEEL PLATFORM
STEEL ADAPTER PLATE
STEEL BRACKET
STEEL SPACER
16
513
4
1 Nut, 1 Spacer (12 Reqd.)
-18 x Hex Bolt
1 Lockwasher, 1 Nut (10 Reqd.)
1 Nut (3 Reqd.)
1 Nut (4 Reqd.)
1 Lockwasher, 1 Nut (10 Reqd.)
1 Nut (3 Reqd.)
Slots (4 Reqd.)
1"!3" Slots (4 Reqd.)
Slots (10 Reqd.)
3
4
3
4
3
8
2 Lb. Per Foot
Flanged Channel
See General Notes
For Finish Requirements
Sheet No.
Index No.
2008 FDOT Design StandardsRevision
532
00
MAILBOXES
2 of 3
Last
STEEL PIPE AND WOOD SUPPORT POSTS
9"
POST SPACING
ELEVATION
FRONT VIEW SIDE VIEW
FRONT VIEW SIDE VIEW
TOP VIEW
BOTTOM VIEW
SIDE VIEW
FRONT VIEW
END VIEW
SIDE VIEW
END VIEW
END VIEW
2"
4" 4"
6"
3"
3"
1"
3" 3"
4"
Anti-Twist Plate
2 Washers, 1 Lockwasher,
Shelf
7"
END VIEW
Bracket
Bracket
Platform
15"
8"
4" X 4" WOOD POST
Platform
3
8 -16! Hex Bolt,
2 Washers, 1 Lockwasher,
#8-32! Slotted Rd. Hd. Bolt #8-32! Slotted Rd. Hd. Bolt3
43
4
3
8-16!3" Hex Bolt,
2 Washers, 1 Lockwasher,(Flange To Outside)
3
8-16! Hex Bolt,3
4
2 Washers, 1 Lockwasher,
-16! Hex Bolt,3
8 41
2
h=
42
" t
o 4
8"
See G
eneral
Note
s
h (Min.) h (Min.)
71
2
11
2
11
4
21
4 11
2 11
2 21
4
23 4
23 4
16
7
16
7
116
3
116
3
16
7
1163
1163
1 2
16
1
75
8
23
4 23
4
11
2
3 42
1 43
3 4
71 2
16
7
16
1
Nominal 23
8
Muffler Clamp
31
2
116
5116
5
41 2
21 4
11 2
11 2
1
8
16
7
41
24
1
2
116
3
116
3
23
4 23
4
1
216
7
11
2
1163
1163
11 2
11 2
16
1
R x 11
4
1
4x
1
2 Slots
1 2
7 8
Note: See General Notes for finish requirements
2" \ PIPE POST
3
4
(Stove Bolt), 2 Washers,
1 Lockwasher, 1 Nut (6 Reqd.)
1 Nut (12 Reqd.)1 Nut (2 Reqd.)
Muffler Clamp (2 Reqd.)
1 Nut (4 Reqd.)
1 Nut (2 Reqd.)
! Slots (4 Reqd.)
! Slots (4 Reqd.)
! Slots (4 Reqd.)
Dia. (8 Reqd.)
Dia. (4 Reqd.)
Dia. (4 Reqd.)
(Stove Bolt), 2 Washers,
(Flange To Inside)
Slots (4 Reqd.)
SINGLE OR COMBINED WOOD, FLANGED CHANNEL
OR PIPE POST TYPES SHOWN ON THIS INDEX
STEEL PLATFORM
STEEL BRACKETSTEEL CLAMP
STEEL ANTI-TWIST PLATE
STEEL SHELF
3
4
3
4
24" M
ax. D
epth
16
7
1 Lockwasher, 1 Nut (6 Reqd.)
Nominal 2" \ (2.375 o.d.) Steel Pipe
Schedule 40 Or Resistance Welded,
ASTM A569 & A669, Min. 50,000 psi
Yield Strength. See General Notes
For Finish Requirements.
Sheet No.
Index No.
2008 FDOT Design StandardsRevision
532
00
MAILBOXES
3 of 3
Last