Lighting Design Guide, Infinity - Thrive Agritech Design Guide: Infinity LED Light Indoor Farming A...
Transcript of Lighting Design Guide, Infinity - Thrive Agritech Design Guide: Infinity LED Light Indoor Farming A...
LightingDesignGuide:InfinityLEDLight
IndoorFarming
ALightingDesignGuideforControlledEnvironmentAgriculture
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
1
BackgroundOverviewThisapplicationnotedescribesoptimizedlightinglayoutsusingThriveAgritech’sInfinityLEDLightBar.Thelightinglayoutsaddressmanyofthecommonlightingrequirementsforindooragriculture,andcoverarangeofilluminationareasandintensities.Thelightinglayoutsspecify:
• NumberofInfinityLightsovertheplantarea• Mountingheightofthelights• Positionandcenter-to-centerspacingofthelights
IlluminationAreaTypicalilluminationareas(tables,shelves,etc.)forindooragricultureincludefootprintsof2’x4’,4’x4’,and4’x8’.Oftentheseilluminationareasarebuildingblocksthatarecombinedtocreatelargergrowingareaswithinacommercialgrowfacility.Theobjectiveofthisapplicationnoteistospecifythelightingdesignsforthebuildingblocks,the2’x4’,4’x4’and4’x8’areas,whichcanthenbeextendedtolargerareas.LightIntensityTheprimaryapplicationfortheInfinityLinearLEDLightistoprovideenergyefficientilluminationforleafygreensandothervegetativegrowth,withlightintensitiesattheplantsurfacerangingfrom100-400umols/m2/sec.TheInfinityLEDLighthasbeendesignedtoreplaceolder,lessefficient,lightingtechnologiesincludingfluorescentandmetalhalide.LightUniformityThelightinglayoutscreatedwithinthisdesignguidehavebeenoptimizedtoproduceuniformilluminationovertheextentoftheplantsurfacearea.Non-StandardLightingDesignsThisapplicationnoteaddressesthemostcommondesignconfigurationsandintensityrequirements.PleasecontactThriveAgritech’sapplicationsengineeringteamwithlightingdesignrequirementsnotcoveredwithinthisguide.
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
2
SummaryofLightingDesigns
(Detailedlightinglayoutsareonthefollowingpages)
2’x4’IlluminationArea
LightIntensity(umols/m2/sec)
#ofInfinityLights
MountingHeight(inches)
Center-to-CenterSpacing(inches) PageNumber
100 1 15” n/a 3200 2 10” 12” 4300 3 9” 8” 5400 3 6” 8” 6
4’x4’IlluminationArea
LightIntensity(umols/m2/sec)
#ofInfinityLights
MountingHeight(inches)
Center-to-CenterSpacing(inches) PageNumber
100 2 15” 24” 7200 4 12” 12” 8300 5 8” 9.6” 9400 6 6” 8” 10
4’x8’IlluminationArea
LightIntensity(umols/m2/sec)
#ofInfinityLights
MountingHeight(inches)
Center-to-CenterSpacing(inches) PageNumber
100 4 15” 24” 11200 8 12” 12” 12300 10 9” 9.6” 13400 12 6” 8” 14
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
3
2’x4’IlluminationArea100umols/m2/sec
LightingDesign• #ofInfinities:1• MountingHeight:15”
IsometricView
TopDownView
IntensityMapAvgPPFD=77umols/m2/sec,MaxPPFD=120umols/m2/sec
InfinityLight
2feet
4feet
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
4
2’x4’IlluminationArea200umols/m2/sec
LightingDesign• #ofInfinities:2• MountingHeight:10”• Center-to-centerspacing:12”
IsometricView
TopDownView
IntensityMapAvgPPFD=184umols/m2/sec,MaxPPFD=247umols/m2/sec
12”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
5
2’x4’IlluminationArea300umols/m2/sec
LightingDesign• #ofInfinities:3• MountingHeight:9”• Center-to-centerspacing:8”
IsometricView
TopDownView
IntensityMap
AvgPPFD=284umols/m2/sec,MaxPPFD=376umols/m2/sec
8”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
6
2’x4’IlluminationArea400umols/m2/sec
LightingDesign• #ofInfinities:3• MountingHeight:6”• Center-to-centerspacing:8”
IsometricView
TopDownView
IntensityMapAvgPPFD=339umols/m2/sec,MaxPPFD=458umols/m2/sec
8”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
7
4’x4’IlluminationArea100umols/m2/sec
LightingDesign• #ofInfinities:2• MountingHeight:15”• Center-to-centerspacing:24”
IsometricView
TopDownView
IntensityMapAvgPPFD=100umols/m2/sec,MaxPPFD=159umols/m2/sec
24”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
8
4’x4’IlluminationArea200umols/m2/sec
LightingDesign• #ofInfinities:4• MountingHeight:12”• Center-to-centerspacing:12”
IsometricView
TopDownView
IntensityMap
AvgPPFD=200umols/m2/sec,MaxPPFD=269umols/m2/sec
12”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
9
4’x4’IlluminationArea300umols/m2/sec
LightingDesign• #ofInfinities:5• MountingHeight:8”• Center-to-centerspacing:9.6”
IsometricView
TopDownView
IntensityMap
AvgPPFD=299umols/m2/sec,MaxPPFD=390umols/m2/sec
9.6”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
10
4’x4’IlluminationArea400umols/m2/sec
LightingDesign• #ofInfinities:6• MountingHeight:6”• Center-to-centerspacing:8”
IsometricView
TopDownView
IntensityMapAvgPPFD=373umols/m2/sec,MaxPPFD=481umols/m2/sec
8”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
11
4’x8’IlluminationArea100umols/m2/sec
LightingDesign• #ofInfinities:4• MountingHeight:15”• Center-to-centerspacing:24”
IsometricView
TopDownView
IntensityMapAvgPPFD=106umols/m2/sec,MaxPPFD=143umols/m2/sec
24”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
12
4’x8’IlluminationArea200umols/m2/sec
LightingDesign• #ofInfinities:8• MountingHeight:12”• Center-to-centerspacing:12”
IsometricView
TopDownView
IntensityMapAvgPPFD=204umols/m2/sec,MaxPPFD=270umols/m2/sec
12”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
13
4’x8’IlluminationArea300umols/m2/sec
LightingDesign• #ofInfinities:10• MountingHeight:9”• Center-to-centerspacing:9.6”
IsometricView
TopDownView
IntensityMapAvgPPFD=303umols/m2/sec,MaxPPFD=383umols/m2/sec
9.6”
___________________________________________________________________________Revision1 www.thriveagritech.com [email protected] 800-205-7216
14
4’x8’IlluminationArea400umols/m2/sec
LightingDesign• #ofInfinities:12• MountingHeight:6”• Center-to-centerspacing:8”
IsometricView
TopDownView
IntensityMapAvgPPFD=400umols/m2/sec,MaxPPFD=497umols/m2/sec
8”