FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL...

29
1 2013 TAES TECHNICAL PUBLICATION Issued: January 2013 FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de la République – B. P. n° 53 - 78401 CHATOU CEDEX - FRANCE Tel : 33 1 34.80.73.46 Fax : 33 1 34.80.75.95 E-Mail : [email protected] THALES AVIONICS ELECTRICAL SYSTEMS

Transcript of FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL...

Page 1: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

1

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

TECHNICAL PUBLICATION

FALCON

- 2013 -

THALES

- CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de la République – B. P. n° 53 - 78401 CHATOU CEDEX - FRANCE

Tel : 33 1 34.80.73.46 Fax : 33 1 34.80.75.95 E-Mail : [email protected]

THALES AVIONICS ELECTRICAL SYSTEMS

Page 2: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

2

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

APPLICABLE TECHNICAL PUBLICATION

1. General conditions 2. List of LRU’s 3. Details of evolutions 4. Statement of agreement

Page 3: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

3

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

1. GENERAL CONDITIONS CMM : Component Maintenance Manual. TCMS : Technical Characteristics Maintenance Sheet. SB : Service Bulletin. SIL : Service Information Letter.

Technical Publications (CMM/SB/SIL) are available. To obtain the sale conditions, contact your Commercial Contact. Prior to the delivery of a CMM, the customer shall sign a Statement of Agreement.

Page 4: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

4

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

2. LIST OF LRU’S THALES vendor code

TAES P/N DESCRIPTION Electronic Rotable Quantity par A/C

F 1 0

F 2 0

F 2 0 - 5

F 2 0 0

F 5 0

F 5 0 E X

F 9 0 0

F 9 0 0 E X

F 2 0 0 0

F0296 12800-2 Alternator R 2 F0296 12800-2-1 Alternator R 2 F0296 12900-6 GCU E 3 F0296 8040A Starter Gen. R 1 1 F0296 8040C Starter Gen. R 1 1 F0296 8060-140 Starter Gen. R 3 3 1 F0296 8060-141 Starter Gen. R 3 3 1 F0296 8060-141-1 Starter Gen. R 2 3 3 1 F0296 8060-150 Starter Gen. R 2 3 3 1 F0296 8060-160 Starter Gen. R 2 3 3 1 F0296 8060-3 Starter Gen. R 3 3 F0296 8060-300 Starter Gen. R 3 3 F0296 8060-320 Starter Gen. R 3 3 F0296 8060-320-1 Starter Gen. R 3 3 F0296 8060-360 Starter Gen. R 3 3 F0296 D22 GCU E 1 1 F0296 D22-010 GCU E 3 F0296 D22-010-1 GCU E 3 F0296 D22-011 GCU E 3 F0296 D22-011-1 GCU E 3 F0296 D22-022 GCU E 3 3 F0296 D22-032 GCU E 3 F0296 D22-04 GCU E 3 3 F0296 D22-041 GCU E 3 3 F0296 D22-04-1 GCU E 3 3 F0296 D22-041-1 GCU E 3 3 F0296 D22-100 GCU E 3 3 F0296 D22-500 GCU E 3 F0296 D22-500-1 GCU E 3 F0296 D22-501 GCU E 3 F0296 D22-501-1 GCU E 3 F0296 D22-600 GCU E 2 3 3

Page 5: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

5

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

3. DETAILS OF EVOLUTIONS

ALTERNATOR P/N 12800-2 CMM reference : 24-30-50 Revision 1 : Date of update June, 15th 2000

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

Amendment A Insulation varnish improvement

/ 1995

Amendment B Identification plate location modification

/ 1995

12800-2-1 Asbestos deletion

Mandatory during repair or

overhaul 2000 SB12800-2-24-001

dated 25/03/1999

ALTERNATOR P/N 12800-2-1 CMM reference : 24-30-50 Revision 1 : Date of update June, 15th 2000

Evolution Reason Application In

Productionsince

SB SIL

/ Packaging for Alternator

Recommended for shipment /

SIL12800-2-1-001Rev. 1

dated 14/04/2012

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

Page 6: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

6

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

Amendment C

Power bridge corosion protection improvement

Systematically during repair or

overhaul 2005

SB12800-2-1-24-001

dated 25/01/2006

Amendment D Maintainability improvement

During repair if component has to be replaced

2011 SB12800-2-1-24-

002 dated 22/11/2010

GENERATOR CONTROL UNIT P/N 12900-6 CMM reference : 24-30-51 Revision 1 : Date of update April,15th 1998

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment A

Thresholds of currents and overloads limitations

Mandatory during repair 1997 SB12900-24-002

dated 02/12/1997

Amendment B Improvement of reliability

Mandatory during repair 2002

Amendment C Improvement of reliability

Mandatory during repair 2004

Amendment D PMG fuse value modification

Mandatory during repair 2008 SB12900-24-003

dated 17/03/2008

/ To guaranty solder quality

Mandatory during repair 2009 SB12900-6-24-004

dated 26/03/2009

Page 7: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

7

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

STARTER GENERATOR P/N 8040A

Evolution Reason Application In

Productionsince

SB SIL

/ / / / / /

STARTER GENERATOR P/N 8040C

Evolution Reason Application In

Productionsince

SB SIL

/ / / / / /

STARTER GENERATOR P/N 8060-140 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ To improve electrical bonding

Recommended / SIL8060-140-001dated 2/10/1989

/ Improvement of reliability Recommended / SIL8060-140-002

dated 1/11/1991

Page 8: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

8

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

8060-141 Improvement of ripple voltage level

Mandatory during Overhaul / SIL8060-140-003

dated 15/10/1995

/ Brush check and brush replacement

Recommended / SIL8060-14*-24-001dated 24/10/2003

Amendment A Protection improvement Recommended 1986

Amendment B Improvement of reliability Mandatory 1986

Amendment C Improvement of reliability Mandatory 1987 SB8060-140-24-01

dated 01/05/1987

Amendment D Improvement of reliability Mandatory 1987

Amendment E Improvement of reliability Mandatory 1993

Amendment H Cooling improvement

In case of frame replacement 1999

Amendment J Production improvement

In case of End Bell Housing

repair or replacement

1999

8060-140-1 Asbestos deletion

Mandatory during repair 1999 SB8060-14*-24-002

dated 06/07/1999

/ Overhaul procedure

Mandatory during overhaul /

SB8060-1**-24-003 Rev. 2

dated 14/11/2003

STARTER GENERATOR P/N 8060-141 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

Page 9: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

9

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ Brush check and brush replacement

Recommended / SIL8060-14*-24-001dated 24/10/2003

Amendment C Cooling improvement

In case of frame replacement 1999

Amendment D Production improvement

In case of End Bell Housing

repair or replacement

1999

8060-141-1 Asbestos deletion

Mandatory during repair 1999 SB8060-14*-24-002

dated 06/07/1999

/ Overhaul procedure

Mandatory during overhaul /

SB8060-1**-24-003 Rev. 2

dated 14/11/2003

STARTER GENERATOR P/N 8060-141-1 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ Brush check and brush replacement

Recommended / SIL8060-14*-24-001dated 24/10/2003

Amendment C Cooling improvement

In case of frame replacement 1999

Page 10: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

10

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

Amendment D Production improvement

In case of End Bell Housing

repair or replacement

1999

/ Overhaul procedure

Mandatory during overhaul /

SB8060-1**-24-003 Rev. 2

dated 14/11/2003

Amendment E Improvement of reliability

Mandatory during repair 1999

SB8060-1**-24-005 Rev. 1

dated 10/01/2005

Amendment F Improvement of reliability Recommended 2006 SB8060-1**-24-006

dated 28/04/2006

Amendment G Improvement of reliability Recommended 2006

SB8060-1**-24-007 Rev. 1

dated 03/08/2007

8060-150 Improvement of maintenance

On customer request 2000

SB8060-141-1-24-001

Rev. 1 dated 25/01/2006

STARTER GENERATOR P/N 8060-150 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ Brush bedding procedure Recommended / SIL8060-***-24-001

dated 06/03/2009

Page 11: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

11

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

/ Packaging for Statrter Generator

Recommended / SIL8060-***-24-002dated 01/09/2009

Amendment A Residual voltage improvement Recommended 2001

Amendment B Improvement of reliability Recommended 2004

SB8060-1**-24-005 Rev. 1

dated 10/01/2005

Amendment C Improvement of reliability Recommended 2006 SB8060-1**-24-006

dated 28/04/2006

Amendment D Improvement of reliability Recommended 2006

SB8060-1**-24-007 Rev. 1

dated 03/08/2007

8060-160 Improvement of maintenance Recommended 2003

SB8060-150-24-001

dated 30/03/2004

8060-160 Amendment A

Improvement of maintenance Recommended 2003

SB8060-150-24-001

dated 30/03/2004

/ Overhaul procedure

Mandatory during overhaul /

SB8060-1**-24-003 Rev. 2

dated 14/11/2003

STARTER GENERATOR P/N 8060-160 CMM reference : 24-35-60 Revision 6 : Date of update July, 10th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

Page 12: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

12

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

/ Brush bedding procedure Recommended / SIL8060-***-24-001

dated 06/03/2009

/ Packaging for Statrter Generator

Recommendedfor shipment / SIL8060-***-24-002

dated 01/09/2009

Amendment B Improvement of reliability Recommended 2006 SB8060-1**-24-006

dated 28/04/2006

Amendment C Improvement of reliability Recommended 2006

SB8060-1**-24-007 Rev. 1

dated 03/08/2007

STARTER GENERATOR P/N 8060-3 CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ Improvement of electrical bonding

Recommended / SIL8060-2/300-001

rev. 2 dated 02/10/1989

/ Tightening brush ckeck Recommended /

SIL8060-300/-03-002

dated 01/11/1990

Amendment A Improvement of reliability Recommended 1977

Amendment B Improvement of reliability Recommended 1978

Page 13: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

13

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

Amendment C Improvement of reliability Recommended 1978

Amendment D Improvement of reliability Recommended 1978

Amendment E Improvement of reliability

On customer request 1978

Amendment F Improvement of reliability Recommended 1978

Amendment G Improvement of reliability Recommended 1978

Amendment H Improvement of reliability Recommended 1978

Amendment J Improvement of reliability Mandatory 1978

Amendment K Improvement of reliability Mandatory 1979

Amendment L Improvement of reliability Mandatory 1979

Amendment M Improvement of reliability Mandatory 1979

Amendment N Improvement of reliability Recommended 1979

Amendment P To increase the reliability Recommended 1981 SB8060-24-001

dated 05/05/1981

Amendment R Improvement of reliability Recommended 1981

Amendment S Improvement of reliability Recommended 1981

Amendment T Improvement of reliability Recommended 1983

Amendment U Improvement of reliability Recommended 1985

Amendment V Improvement of reliability

Recommendedduring repair or

overhaul 1985 SB8060-24-002

dated 01/11/1986

Amendment W Improvement of reliability Recommended 1985

Page 14: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

14

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

Amendment Y Improvement of insulation Recommended 1987 SB8060-3-24-05

dated 01/05/1987

Amendment Z Improvement of reliability Recommended 1987

8060-300 Improvement of reliability Recommended 1985

SB8060-24-003 rev. 2

dated 02/01/1990

8060-3-1 Asbestos deletion

Mandatory during repair 1998 SB8060-3*-24-001

dated 06/07/1999

/ Overhaul procedure

Mandatory during overhaul /

SB8060-3*-24-002 rev. 2

dated 14/11/2003

STARTER GENERATOR P/N 8060-300 CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ Improvement of electrical bonding

Recommended / SIL8060-2/300-001

rev. 2 dated 02/10/1989

/ Tightening brush ckeck Recommended /

SIL8060-300/-03-002

dated 01/11/1990

8060-320 Improvement of reliability Recommended / SIL8060-300-003

dated 15/07/1995

Amendment A Improvement of insulation Recommended 1987 SB8060-300-24-01

dated 01/05/1987

Amendment B Improvement of reliability Recommended 1987

Amendment C Improvement of reliability Recommended 1993

Page 15: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

15

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

8060-300-1 Asbestos deletion

Mandatory during repair 1998 SB8060-3*-24-001

dated 06/07/1999

Amendment F Cooling improvement

In case of frame replacement 1999

/ Overhaul procedure

Mandatory during overhaul /

SB8060-3*-24-002 rev. 2

dated 14/11/2003

STARTER GENERATOR P/N 8060-320 CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ Brush bedding procedure Recommended / SIL8060-***-24-001

dated 06/03/2009

/ Packaging for Statrter Generator

Recommendedfor shipment / SIL8060-***-24-002

dated 01/09/2009

8060-320-1 Asbestos deletion

Mandatory during repair 1998 SB8060-3*-24-001

dated 06/07/1999

Amendment C Cooling improvement

In case of frame replacement 1999

Amendment D Production improvement

In case of End Bell Housing

repair or replacement

1999

/ Overhaul procedure

Mandatory during overhaul /

SB8060-3*-24-002 rev. 2

dated 14/11/2003

Page 16: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

16

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ Brush bedding procedure Recommended / SIL8060-***-24-001

dated 06/03/2009

/ Packaging for Starter Generator

Recommendedfor shipment / SIL8060-***-24-002

dated 01/09/2009

Amendment C Cooling improvement

In case of frame replacement 1999

Amendment D Production improvement

In case of End Bell Housing

repair or replacement

1999

Amendment E Improvement of reliability Recommended 2000

Amendment F Improvement of reliability Recommended 2001

Amendment G Improvement of reliability Recommended 2004

SB8060-3*-24-004 rev. 1

dated 10/01/2005

Amendment H Improvement of reliability Recommended 2006 SB8060-3*-24-005

dated 28/04/2006

Amendment J Improvement of reliability Recommended 2006

SB8060-3*-24-006 rev. 1

dated 04/06/2007

8060-360 Improvement of scheduled maintenance

On customer request 2003

SB8060-320-1-24-001

dated 13/04/2004

8060-360 Amendment A

Improvement of scheduled maintenance

On customer request 2003

SB8060-320-1-24-001

dated 13/04/2004

/ Overhaul procedure

Mandatory during overhaul /

SB8060-3*-24-002 rev. 2

dated 14/11/2003

STARTER GENERATOR P/N 8060-320-1

Page 17: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

17

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

STARTER GENERATOR P/N 8060-360 CMM reference : 24-35-02 Revision 9 : Date of update August, 08th 2006

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/ Second source of Anti-flash varnish

Recommended / SIL24-99-003 dated 05/09/2012

/ Brush bedding procedure Recommended / SIL8060-***-24-001

dated 06/03/2009

/ Packaging for Statrter Generator

Recommendedfor shipment / SIL8060-***-24-002

dated 01/09/2009

Amendment B Improvement of reliability Recommended 2006 SB8060-3*-24-005

dated 28/04/2006

Amendment C Improvement of reliability Recommended 2006

SB8060-3*-24-006 rev. 1

dated 04/06/2007

GENERATOR CONTROL UNIT P/N D22 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment A Improvement of reliability Recommended 1977

Amendment B Improvement of reliability Recommended 1977

Amendment C Improvement of reliability Recommended 1977

Page 18: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

18

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

Amendment D Improvement of reliability Recommended 1981

Amendment E Improvement of reliability Recommended 1978

Amendment F Improvement of reliability Recommended 1979

Amendment G Improvement of reliability Recommended 1979

SBD22-24-008 rev. 1

dated 01/01/1987

Amendment H Improvement of reliability Recommended 1979

Amendment J Improvement of reliability Recommended 1979

SBD22-24-001 rev. 1

dated 01/01/1986

Amendment K Improvement of reliability Recommended 1983 SBD22-24-003

dated 01/12/1984

D22-010 Improvement of reliability Recommended 1981 SBD22-24-002

dated 01/03/1983

Amendment L Improvement of reliability Recommended 1983

SBD22-24-004 rev. 1

dated 01/03/1986

Amendment M Improvement of reliability Recommended 1986

SBD22-24-007 rev. 1

dated 01/11/1986

D22-011 Amendment M-N-Q-R-S

Improvement of reliability

On customer request 1996

SBD22-24-017 rev. 1

dated 23/09/1996

GENERATOR CONTROL UNIT P/N D22-010 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment K Improvement of reliability Recommended 1983 SBD22-24-003

dated 01/12/1984

Page 19: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

19

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

Amendment L Improvement of reliability Recommended 1985

Amendment M Improvement of reliability Recommended 1985

SBD22-24-007 rev. 1

dated 01/11/1986

Amendment N Improvement of reliability

Recommendedon repair 1989

Amendment P Improvement of reliability

Recommendedon repair 1990

SBD22-24-010 rev. 1

dated 01/12/1991

Amendment Q Improvement of reliability

Recommendedon repair 1990 SBD22-24-011

dated 01/10/1990

Amendment S Improvement of reliability

Recommendedon repair 1993

D22-010-1 Integration Amendments K-L-M-N-Q-R

Recommended 1990

D22-011 Amendment M-N-Q-S

Improvement of reliability

Recommendedon repair 1997

SBD22-24-017 rev. 1

dated 23/09/1996

GENERATOR CONTROL UNIT P/N D22-010-1 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment A Improvement of reliability Recommended 1993

Amendment B Improvement of reliability Recommended 1997

Page 20: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

20

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

D22-011-1 Improvement of reliability Recommended 1997

SBD22-24-017 rev. 1

dated 23/09/1996

D22-100 Improvement of reliability Recommended 1998 SBD22-24-018

dated 01/09/1998

GENERATOR CONTROL UNIT P/N D22-011 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment T Improvement of reliability Recommended 1996

GENERATOR CONTROL UNIT P/N D22-011-1 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Page 21: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

21

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

Amendment A Improvement of reliability Recommended 1997

D22-100 Improvement of reliability Recommended 1998 SBD22-24-018

dated 01/09/1998

GENERATOR CONTROL UNIT P/N D22-022 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

D22-030 Improvement of reliability Recommended 1980

Amendment H Improvement of reliability Recommended 1980

SBD22-24-001 rev. 1

dated 01/01/1986

Amendment J Improvement of reliability Recommended 1984 SBD22-24-003

dated 01/12/1984

Page 22: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

22

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

GENERATOR CONTROL UNIT P/N D22-032 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment J Improvement of reliability Recommended 1983 SBD22-24-003

dated 01/12/1984

Amendment K Improvement of reliability Recommended 1982

D22-04 Improvement of reliability Recommended 1985

SBD22-24-006 rev. 1

dated 01/01/1987

GENERATOR CONTROL UNIT P/N D22-04 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Page 23: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

23

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

Amendment K Improvement of reliability Recommended 1982

Amendment L Improvement of reliability Recommended 1985 SBD22-24-003

dated 01/12/1984

Amendment M Improvement of reliability Recommended 1985

SBD22-24-007 rev; 1

dated 01/11/1986

Amendment N Improvement of reliability Recommended 1991 SBD22-24-013

dated 01/01/1992

Amendment P Improvement of reliability Recommended 1991 SBD22-24-014

dated 01/01/1992

Amendment Q Improvement of reliability Recommended 1991 SBD22-24-016

dated 01/01/1992

D22-04-1 Improvement of reliability Recommended 1991

D22-041 Improvement of reliability Recommended 2003 SBD22-04-24-001

dated 08/07/2004

GENERATOR CONTROL UNIT P/N D22-041 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Page 24: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

24

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

GENERATOR CONTROL UNIT P/N D22-04-1 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

D22-041-1 Improvement of reliability Recommended 2003 SBD22-04-1-24-001

dated 08/07/2004

GENERATOR CONTROL UNIT P/N D22-041-1 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

GENERATOR CONTROL UNIT P/N D22-100 CMM reference : 24-35-03 Revision 6 : Date of update July, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

Page 25: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

25

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment A Improvement of reliability Recommended 1999 SBD22-100-24-001

dated 20/01/2009

GENERATOR CONTROL UNIT P/N D22-500 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

/ Modification of test setup Recommended / SILD22-500-001

dated 01/02/1992

Amendment A Improvement of reliability Recommended 1985 SBD22-500-24-004

dated 01/03/1991

Amendment B Improvement of reliability Recommended 1989 SBD22-500-24-005

dated 01/03/1991

Amendment C Improvement of reliability Recommended 1990

SBD22-500-24-001 rev. 1

dated 01/03/1991

Amendment D Improvement of reliability Recommended 1990

SBD22-500-24-002 rev. 1

dated 01/03/1991

Amendment E Improvement of reliability Recommended 1991 SBD22-500-24-006

dated 01/03/1991

Page 26: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

26

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

Evolution Reason Application In

Productionsince

SB SIL

Amendment F Improvement of reliability Recommended 1996 SBD22-500-24-009

dated 03/02/2003

D22-500-1 Integration

Amendments A-B-D-E

Recommended 1990 SBD22-500-24-007 dated 15/07/1995

D22-501 Improvement of reliability Recommended 1995 SBD22-500-24-007

dated 15/07/1995

GENERATOR CONTROL UNIT P/N D22-500-1 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

/ Modification of test setup Recommended / SILD22-500-001

dated 01/02/1992

Amendment A Improvement of reliability Recommended 1996 SBD22-500-24-009

dated 03/02/2003

D22-501-1 Improvement of reliability Recommended 1995 SBD22-500-24-007

dated 15/07/1995

D22-600 Improvement of reliability Recommended 1998 SBD22-500-24-008

dated 20/04/1998

Page 27: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

27

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

GENERATOR CONTROL UNIT P/N D22-501 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment F Improvement of reliability Recommended 1996 SBD22-500-24-009

dated 03/02/2003

GENERATOR CONTROL UNIT P/N D22-501-1 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

D22-600 Improvement of reliability Recommended 1996 SBD22-500-24-008

dated 20/04/1998

Amendment A Improvement of reliability Recommended 1996 SBD22-500-24-009

dated 03/02/2003

Page 28: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

28

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

GENERATOR CONTROL UNIT P/N D22-600 CMM reference : 24-35-61 Revision 2 : Date of update November, 24th 2005

Evolution Reason Application In

Productionsince

SB SIL

/ Order consumables products

Recommended / SIL24-99-001 dated 03/01/2011

/

Electrostatic Discharge Sensitive components

Recommended / SIL24-99-002 dated 09/12/2010

Amendment A Improvement of reliability Recommended 1996 SBD22-600-24-001

dated 20/04/1998

Amendment B Improvement of reliability Recommended 1999 SBD22-600-24-002

dated 20/01/2009

Page 29: FALCON - 2013 - Thales Group January 2013 1 2013 TAES – TECHNICAL PUBLICATION FALCON TECHNICAL PUBLICATION FALCON - 2013 - THALES - CUSTOMER SUPPORT DEPARTMENT - 41 boulevard de

29

2013 TAES – TECHNICAL PUBLICATION

Issued: January 2013

FALCON

4. STATEMENT OF AGREEMENT Statement of Agreement to Terms and Conditions of Sale of Thales Technical Publications Thales Component Maintenance Manual 24-XX-XX is intended solely for use by Company Name. Copying, reproducing or redistribution of this or any Thales Component Maintenance Manual (CMM) or Service Bulletin (SB), to any other party or location is strictly prohibited without Thales prior written consent. Thales retains all intellectual property rights, title and interest in the CMMs and/or SBs provided, including all rights under applicable patents, copyrights, trademarks and trade secrets, and all renewals and extensions thereto. Company Name shall not alter or remove any patent, copyright, trademark, or proprietary rights notice. Agreed to and Accepted by: ____________________________ __________________________ (Print Name) (Title) ____________________________ __________________________ (Signature) (Date)