TAG CST_NAME CSD_NAME CST_COMP TYPE SIGNAL FBMFI0009 AI 130A03
FI0013 AI 130A03PI0079 AI 130A03
FV0007A AO 130A03
FI0007A AI 130A03FV0007B AO 130A16FI0007B AI 130A04MPR0007 DI 130A15MPSS0007 DO 130A22MPLR0007 DI 130A15MPE0007 DI 130A15MPSR0007 DO 130A22PV1079A AO 130A16PV1079B AO 130A16PI1078 AI 130A04TI1044 AI 130A04LI1008 AI 130A04FI1015 AI 130A04FV1015 AO 130A16XZO1082 DI 130A15XZC1082 DI 130A15PSLL0020 DI 130A15
PI0008 AI 130A03
FI0006 AI 130A03
FV0006 AO 130A16
TI0006 AI 130A03
LV0004 AO 130A16
LI0004 AI 130A03
FI0005 AI 130A03
FV0005 AO 130A16MPSS0004B DO 130A22MPSR0004B DO 130A22MPLR0004B DI 130A15MPR0004B DI 130A15MPE0004B DI 130A15MPSS0004A DO 130A22MPSR0004A DO 130A22MPR0004A DI 130A15MPLR0004A DI 130A15MPE0004A DI 130A15XZO0034 DI 130A15XZC0034 DI 130A15
CHANNEL SYSTEM P_ID DEVICE_TYPE2 DCS QGTL1-PRO-07-30005 dP Flow Transmitter FT
3 DCS QGTL1-PRO-07-30005 dP Flow Transmitter FT2 DCS QGTL1-PRO-07-30005 Pressure Transmitter with Diaphragm PT
1 DCS QGTL1-PRO-07-30005 Control Valve FV
1 DCS QGTL1-PRO-07-30005 dP Flow Transmitter FT2 DCS QGTL1-PRO-07-30005 Control Valve FV1 DCS QGTL1-PRO-07-30005 dP Flow Transmitter FT1 DCS QGTL1-PRO-07-30005 Motor run MPR1 DCS QGTL1-PRO-07-30005 Motor Stop MPSS2 DCS QGTL1-PRO-07-30005 Motor Available (Local/Remote) MPLR3 DCS QGTL1-PRO-07-30005 Motor Electrical Fault MPE2 DCS QGTL1-PRO-07-30005 Motor Start MPSR3 DCS QGTL1-PRO-07-30109 Control Valve PV4 DCS QGTL1-PRO-07-30109 Control Valve PV3 DCS QGTL1-PRO-07-30109 Indicator PI4 DCS QGTL1-PRO-07-30109 Transmitter TT5 DCS QGTL1-PRO-07-30109 Indicator LI6 DCS QGTL1-PRO-07-30109 dP Flow Transmitter FT5 DCS QGTL1-PRO-07-30109 Control Valve FV4 DCS QGTL1-PRO-07-30109 Limit Switch Open Indication XZXO5 DCS QGTL1-PRO-07-30109 Limit Switch Closed Indication XZXC6 DCS QGTL1-PRO-07-30109 Low Low Alarm PALL
6 DCS QGTL1-PRO-07-30006 SH 2 Pressure Transmitter with Diaphragm PT
7 DCS QGTL1-PRO-07-30006 SH 2 dP Flow Transmitter FT
8 DCS QGTL1-PRO-07-30006 SH 2 Control Valve FV
8 DCS QGTL1-PRO-07-30006 SH 2 Thermocouple type K
6 DCS QGTL1-PRO-07-30006 SH 2 Control Valve LV
4 DCS QGTL1-PRO-07-30006 SH 2 Indicator LI
5 DCS QGTL1-PRO-07-30006 SH 2 dP Flow Transmitter FT
7 DCS QGTL1-PRO-07-30006 SH 2 Control Valve FV3 DCS QGTL1-PRO-07-30006 SH 2 Motor Stop MPSS5 DCS QGTL1-PRO-07-30006 SH 2 Motor Start MPSR
12 DCS QGTL1-PRO-07-30006 SH 2 Motor Available (Local/Remote) MPLR8 DCS QGTL1-PRO-07-30006 SH 2 Motor Run MPR9 DCS QGTL1-PRO-07-30006 SH 2 Motor Electrical Fault MPE6 DCS QGTL1-PRO-07-30006 SH 2 Motor Stop MPSS4 DCS QGTL1-PRO-07-30006 SH 2 Motor Start MPSR
10 DCS QGTL1-PRO-07-30006 SH 2 Motor Run MPR11 DCS QGTL1-PRO-07-30006 SH 2 Motor Available (Local/Remote) MPLR13 DCS QGTL1-PRO-07-30006 SH 2 Motor Electrical Fault MPE14 DCS QGTL1-PRO-07-30006 SH 2 Limit Switch Open Indication XZXO15 DCS QGTL1-PRO-07-30006 SH 2 Limit Switch Closed Indication XZXC
ENG_UNITS MIN_SCALE MAX_SCALE ALARM_LL ALARM_Lm3/h 0 360
Nm3/h 0 4000BARG 0 45
% 0 100
m3/h 0 360 120% 0 100m3/h 0 360
% 0 100% 0 100BARG 0 45DEGC 0 200 50 % 0 100 m3/h 0 130% 0 100
BARG 0 45
m3/h 0 180 54
% 0 100
DEGC 0 200
% 0 100
% 0 100 50.26
m3/h 0 180 20
% 0 100
ALARM_H ALARM_HH HLOP HHALOP SERVICE130-PC-007 Min Flow
Nitrogen PurgeWax Flush
130-PC-007 Min Flow
Wax FlushWax Flush
280 Wax FlushWax Flush Pump 130-PC-007Wax Flush Pump 130-PC-007Wax Flush Pump 130-PC-007Wax Flush Pump 130-PC-007Wax Flush Pump 130-PC-007
Backflush Accumulator 130-VD-107Backflush Accumulator 130-VD-107Backflush Accumulator 130-VD-107Wax Backflush Service OPENWax Backflush Service CLOSEDHP Nitrogen
Backflush Wax Drum 130-VD-014
Backflush Wax Drum 130-VD-014
80
160
Backflush Wax Pump 130-PC-004BBackflush Wax Pump 130-PC-004BBackflush Wax Pump 130-PC-004BBackflush Wax Pump 130-PC-004BBackflush Wax Pump 130-PC-004BBackflush Wax Pump 130-PC-004ABackflush Wax Pump 130-PC-004ABackflush Wax Pump 130-PC-004ABackflush Wax Pump 130-PC-004ABackflush Wax Pump 130-PC-004AWax Service OPENWax Service CLOSED
STATE_0 STATE_1 ATC DESCRIPTIONLOOP_NAME COMPOUND REMARKS
0-50%50-100%
has a char. Curve CHART1
EXTRA_NAME CP PLANT_AREA MSCALE BIASFLUSHPUMP
BACKFLUSHPIC0079 WAXDRUM
WAXDRUM
FIC0007A
FIC0007B
has a char. Curve CHART1
DCI_SCO CONNECTION5
33
3
IAG SIGNAL FBM CHANNEL SYSTEM P_IDFI0005 AI 130A03 5 DCS QGTL1-PRO-07-30006 SH 2
DEVICE_TYPE ENG_UNITS MIN_SCALEdP Flow Transmitter FT m3/h 0
MAX_SCALE ALARM_LL ALARM_L ALARM_H ALARM_HH180 20 160
SERVICE STATE_0 STATE_1 ATC DESCRIPTIONLOOP_NAME
COMPOUND REMARKS EXTRA_NAME
0 20 45
0
5
10
15
20
25
30
35
characteristic curve for PI1078
barg
ba
rg
TAG CST_NAME CSD_NAME CST_COMP TYPE SIGNAL FBM CHANNELFI0013 AIN_MON F0013 AINPUT2 TEST AI 130A03 3TI1044 AIN_MON T1044 AINPUT2 TEST AI 130A03 4PI0008 AIN_MON P0008 AINPUT2 TEST AI 130A03 6TI0006 AIN_MON T0006 AINPUT2 TEST AI 130A03 8
SYSTEM P_ID DEVICE_TENG_UNITMIN_SCALMAX_SCAALARM_LLALARM_L ALARM_HDCS QGTL1-PROdP Flow TraNm3/h 0 4000DCS QGTL1-PROTransmitter DEGC 0 200 50DCS QGTL1-PROPressure TrBARG 0 45DCS QGTL1-PROThermocoupDEGC 0 200 10 90
ALARM_HH HLOP HHALOP SERVICE STATE_0 STATE_1 ATC DESCRIPTIONNitrogen Purge
3Backflush Wax Drum 130-VD-014
1 Backflush Wax Drum 130-VD-014
LOOP_NAME COMPOUND REMARKS EXTRA_NAME CP PLANT_AREAFLUSHPUMP 130A00 FLUSHDRUMBACKFLUSH 130A00 BACKFLUSHWAXDRUM has a char. Curve CHART1 130A00 WAXDRUMWAXDRUM 130A00 WAXDRUM
MSCALE BIAS SCI_SCO CONNECTION5333
TAG CST_NAME CSD_NAME CST_COMP TYPE SIGNAL FBM CHANNEL
FI0013 AIN_MON F0013 AINPUT2 AI 131A04 1
FV0007A PID_LOOP F0007A AOUT_TEST2 AO 131A04 5
FI0007A PID_LOOP F0007A AIN_PID AI 131A04 2TI1044 AIN_MON T104 AINPUT2 AI 131A04 3
PI0008 AIN_MON P0008 AINPUT2 AI 131A04 4
FI0006 PID_LOOP F0006 AIN_PID AI 131A05 1
FV0006 PID_LOOP F0006 AOUT_TEST2 AO 131A04 6
TI0006 AIN_MON T0006 AINPUT2 AI 131A05 2
LV0004 PID_LOOP L0004 AOUT_TEST2 AO 131A04 7
LI0004 PID_LOOP L0004 AIN_PID AI 131A05 3
FI0005 PID_LOOP F0005 AIN_PID AI 131A05 4
FV0005 PID_LOOP F0005 AOUT_TEST2 AO 131A04 8
SYSTEM P_ID DEVICE_TYPE ENG_UNITS
DCS QGTL1-PRO-07-30005 dP Flow Transmitter FT Nm3/h
DCS QGTL1-PRO-07-30005 Control Valve FV %
DCS QGTL1-PRO-07-30005 dP Flow Transmitter FT m3/hDCS QGTL1-PRO-07-30109 Transmitter TT DEGC
DCS QGTL1-PRO-07-30006 SH 2 Pressure Transmitter with Diaphragm BARG
DCS QGTL1-PRO-07-30006 SH 2 dP Flow Transmitter FT m3/h
DCS QGTL1-PRO-07-30006 SH 2 Control Valve FV %
DCS QGTL1-PRO-07-30006 SH 2 Thermocouple type K DEGC
DCS QGTL1-PRO-07-30006 SH 2 Control Valve LV %
DCS QGTL1-PRO-07-30006 SH 2 Indicator LI %
DCS QGTL1-PRO-07-30006 SH 2 dP Flow Transmitter FT m3/h
DCS QGTL1-PRO-07-30006 SH 2 Control Valve FV %
MIN_SCALE MAX_SCALE ALARM_LL ALARM_L ALARM_H ALARM_HH HLOP
0 4000
0 100
0 360 120 30 200 50 3
0 45
0 180 54 3
0 100
0 200
0 100
0 100 50 80 1
0 180 20 160 1
0 100
HHALOP SERVICE STATE_0 STATE_1 ATC
Nitrogen Purge
130-PC-007 Min Flow
Wax Flush
Backflush Wax Drum 130-VD-014
Backflush Wax Drum 130-VD-014
DESCRIPTION LOOP_NAME COMPOUND REMARKS
Nitrogen Purge COMPOUNDA
130-PC-007 Min Flow COMPOUNDA
Wax Flush COMPOUNDACOMPOUNDB
Backflush Wax Drum 130-VD-014 COMPOUNDB has a char. Curve CHART1
COMPOUNDB
COMPOUNDB
Backflush Wax Drum 130-VD-014 COMPOUNDC
COMPOUNDC
COMPOUNDC
COMPOUNDC
COMPOUNDC
EXTRA_NAME CP PLANT_AREA MSCALE BIAS SCI_SCO CONNECTION
131A00 PLANT_A 5
131A00 PLANT_A
FIC0007A 131A00 PLANT_A 5131A00 PLANT_A 3
131A00 PLANT_A 3
FIC0006 131A00 PLANT_A 5
131A00 PLANT_A
TIC0006 131A00 PLANT_B 3
131A00 PLANT_B
LIC0004 131A00 PLANT_B 3
FIC0005 131A00 PLANT_B 5
131A00 PLANT_B
TAG CST_NAME CSD_NAME CST_COMP TYPE SIGNAL FBM CHANNELLI1008 AI 130A04 5FI1015 AI 130A04 6
SYSTEM P_ID DEVICE_TYPE ENG_UNITS MIN_SCALEDCS QGTL1-PRO-07-30109 Indicator LI % 0DCS QGTL1-PRO-07-30109 dP Flow Transmitter m3/h 0
MAX_SCALE ALARM_LL ALARM_L ALARM_H ALARM_HHLOP HHALOP100130
SERVICE STATE_0 STATE_1 ATC DESCRIPTION LOOP_NAMEBackflush Accumulator 130-VD-107Backflush Accumulator 130-VD-107
COMPOUND REMARKS EXTRA_NAME CP PLANT_ARMSCALELIC1008
BIAS DCI_SCO CONNECTION