Conferenza ASME Sec.V
Transcript of Conferenza ASME Sec.V
-
8/12/2019 Conferenza ASME Sec.V
1/54
APPLICAZIONE DEI REQUISITI ASME
V AI CONTROLLI NON DISTRUTTIVISUI MATERIALI
Ing. Paolo Pacor
C&P srl
-
8/12/2019 Conferenza ASME Sec.V
2/54
SCOPO
-
8/12/2019 Conferenza ASME Sec.V
3/54
SCOPO
-
8/12/2019 Conferenza ASME Sec.V
4/54
Materiali
ASME IASME VIII Div.1ASME VIII DIV.2
Material: any substance or product formcovered by a specification in Section IIParts A, B or C
ASME III
For Section III, Division 1, metallic
materials manufactured to an SA, SB,
SFA, or any other material
specification permitted in Section III
and that are manufactured, identified,
and certified in accordance with the
requirements of Section III.
-
8/12/2019 Conferenza ASME Sec.V
5/54
Materiali
Quindi, i materiali per lASME sono tali se come minimorispettano i requisiti della Sez. II
E per la Sezione III, anche di quelli specificati in NX2000
-
8/12/2019 Conferenza ASME Sec.V
6/54
Materiali
Prima condizione:
Soddisfare i requisiti della Sezione II
-
8/12/2019 Conferenza ASME Sec.V
7/54
CND
Relativamente ai controlli non distruttivi,
le specifiche della Sezione II richiedono, generalmente, lapplicazione di:
E165 per i liquidi penetranti
A275 per i controlli magnetoscopici
SA388 (Forgiati) SA609 (Fusi) per i controlli UT
E94 (Fusi) per controlli RT
E309 per lEddy Current
-
8/12/2019 Conferenza ASME Sec.V
8/54
CND
PT
SE-165
In questo caso, il punto 10.2 richiede la qualifica dellaprocedura!
Quando?
-
8/12/2019 Conferenza ASME Sec.V
9/54
CND
Qualification of procedures using times, conditions, ormaterials differing from those specified in this general
practice or for new materials may be performed by anyseveral methods and should be agree upon the contractingparties.
-
8/12/2019 Conferenza ASME Sec.V
10/54
CND
A test piece containing one or more discoutinuities of the
smallestrelevant size is used. When agree upon the
contracting parties, the test pieces may contain real orsimulated discontinuities, providing it displays thecharacteristics of the discountinuities encountered inproduction examination.
-
8/12/2019 Conferenza ASME Sec.V
11/54
CND
Non indica variabili essenziali indicate nella Sect.V Art.6
Ne la dimostrazione allIspettore richiesta da T-150
MA la logica simile
T-6.10 specifica che lArt.6 conforme a E-165
-
8/12/2019 Conferenza ASME Sec.V
12/54
CND
MT
SA-275
This test method provides a procedure for magneticparticle examination of steel forgings. The procedure will
produce consistent results upon which acceptance standadscan be based.
Essa stessa una procedura
-
8/12/2019 Conferenza ASME Sec.V
13/54
CND
PERSONALE
Personnel performing the magnetic particle examination tothis test method shall be qualified and certifiedin accordance
with a written procedure conforming to RecommendedPractice No. SNT-TC- I A or another nationalstandard that isacceptable to both the purchaser and the supplier.
-
8/12/2019 Conferenza ASME Sec.V
14/54
CND
SA-275 rimanda alla E-1444 la quale richiede
al punto 5.4 lo sviluppo di una procedura scrittae
di seguito al punto 5.4.1 elenca 15 elementi della proceduraConcettualmente non molto dissimili dalle variabili essenzialielencate nellArt.7 della Sect.V
-
8/12/2019 Conferenza ASME Sec.V
15/54
CND
Al punto 7.1 la E-1444 richiede la
SYSTEM PERFORMANCE VERIFICATION
Iniziale ed ad intervalli specificati in Table 1
Anche questa simile alla richiesta di Demonstration to theInspector di T-150 della Sect.V
-
8/12/2019 Conferenza ASME Sec.V
16/54
CND
UT
SA-388
Specifica per i Forgiati.
Richiede qualifiche del personale in accordo alla
Recommended Practice SNT-TC-1A o altro standardnazionale accettabile ad entrambe le parti
-
8/12/2019 Conferenza ASME Sec.V
17/54
CND
LA SA/A388 non specifica dimostrazioni della procedura.
Ma per gli ultrasuoni, ogni taratura di per s unadimostrazione
-
8/12/2019 Conferenza ASME Sec.V
18/54
REQUISITI ASME III
ASME NON NUCLEARE
NESSUN REQUISITOAGGIUNTIVO RELATIVO ALLEPROCEDURE CND
ASME III
NCA-3800
METALLI MATERIALORGANIZAZIONS QUALITYSYSTEM PROGRAM
NX 2000
MATERIAL
-
8/12/2019 Conferenza ASME Sec.V
19/54
ASME III
MO (MATERIAL ORGANIZATION)
shall be responsable for approval of and control ofactivities performed by suppliers.of subcontracted
services.
NCA-3855.3 (b)
NDE Interni = NDE esterni
-
8/12/2019 Conferenza ASME Sec.V
20/54
ASME III
Come?
Surveying and auditing the supplierestabilished qualitysystem that is consistent with the requirements of thisSubarticle
Or
Having the supplier perform the activities in accordance withcontrol estabilished by MOs quality program.
-
8/12/2019 Conferenza ASME Sec.V
21/54
ASME III
QUINDI:
In accordo al Programma di Qualit suo o del produttore
Ma comunque in accordo ai requisiti di questo Subarticolo
-
8/12/2019 Conferenza ASME Sec.V
22/54
ASME III
COSA CHIEDE IL PROGRAMMA DI QUALITA?
CONTROLLO DEI PROCESSI:
I processi che impattano sulla qualit del materiale, delsource material e dei servizi devono essere sottocontrollo!!
Gli NDE sono uno di questi processi
-
8/12/2019 Conferenza ASME Sec.V
23/54
ASME III
Non solo, gli NDE sono considerati processi speciali e quindi
NCA-3857.1
shall be performed by qualified personnel usingqualified procedure in accordance with specificrequirements
NCA-3855.1 (b)
All NDE examination personnel shall be qualified inaccordance with para NX-5521
-
8/12/2019 Conferenza ASME Sec.V
24/54
ASME III
NCA-3800
Requisiti di Sistema:
NCA-3855.4 Procurement Document Control
Procurement documents shall requiresubcontracted
service to be furnished in accordance with the applicablerequirements of this Subarticle.
-
8/12/2019 Conferenza ASME Sec.V
25/54
ASME III
Cosa richiede lASME III?
Esempio tipico:
FORGIATI
NB-2542 Ultrasonic Examination
All forging in the rough-forged or finished condition, andbars shall be examined in accordance with Art.5 of SectionV.
-
8/12/2019 Conferenza ASME Sec.V
26/54
ASME III
Larticolo V della Sez.V cita:
T-522.1 Requirements. Ultrasonic Examination shall be
performed in accordance with a written procedure which shall as aminimum, contain the requirements listed in Table T-522.
E se torniamo a T-150
(a) When required by referencing Code Section, all nondestructive examination performed under this Code Section shallbe done to a written procedure. A procedure demonstration shallbe performed to satisfaction of the Inspector.
-
8/12/2019 Conferenza ASME Sec.V
27/54
ASME III
QUINDI PER GLI UT VA FATTA
UNA PROCEDURA SCRITTA E VA DIMOSTRATA!
MA A CHI?
INFATTI
INSPECTOR PER LASME E LAI/ANICHE NON E DIRETTAMENTE COINVOLTO NELLATTIVITA DIUNA MO
-
8/12/2019 Conferenza ASME Sec.V
28/54
ASME III
LINTERPRETAZIONE DELLA MAGGIOR PARTE DEITEAM LEADER NUCLEARI E:
LE PROCEDURE VANNO SCRITTE E DIMOSTRATE ACHI SVOLGE LE FUNZIONI EQUIVALENTI DELLAI/ANI
(QM, MANUFACTURER REPRESENTATIVE)
-
8/12/2019 Conferenza ASME Sec.V
29/54
ASME III
Lo stesso ragionamento vale per i Liquidi Penetranti e per leParticelle Magnetiche
NB-2545 Magnetic Particle Examination
NB-2545.1. Examination Procedure. The procedure formagnetic particle examination shall be in accordance withthe methods of Article 7, Section V.
-
8/12/2019 Conferenza ASME Sec.V
30/54
ASME III
ARTICOLO 7
T-721 Written Procedure Requirements
T-721.1 Requirements. Magnetic particle examination shall beperformed in accordance with a written procedure, which shall, asa minimum, contain the requirements listed in Table T-721.
Da qui, tornando ancora al para T-150, risulta necessaria laqualifica della procedura.
-
8/12/2019 Conferenza ASME Sec.V
31/54
ASME III
Lo stesso dicasi per i Liquidi Penetranti:
NB-2546 Liquid Penetrant Examination
NB-2546.1 Examination Procedure. The procedure for liquidpenetrant examination shall be in accordance with themethods of Section V, Article 6.
Che chiede la stessa dimostrazione del procedimento
Vediamo come:
-
8/12/2019 Conferenza ASME Sec.V
32/54
ASME V
T-621 Written Procedure Requirements
T-621.1 Requirements. Liquidi pentrant examination shall beperformed in accordance with a written procedure whichshall as a minimum, contain the requirements listed in Table
T-621. The written procedure shall estabilisha single
value, or a range of values, for each requirement.
-
8/12/2019 Conferenza ASME Sec.V
33/54
ASME V
-
8/12/2019 Conferenza ASME Sec.V
34/54
ASME V
VEDIAMO I PUNTI CRITICI:
Identification of and any change in type or family group ofpenetrant materials including developers, emulsifiers, etc).
Gli ASME Team Leader si aspettano di trovare una solaindicazione per prodotto e famiglia
Cos come per la seconda variabile
-
8/12/2019 Conferenza ASME Sec.V
35/54
ASME V
Surface preparation (finishing and cleaning, including typeof solvent).
Anche in questo caso dovremmo trovare una solaindicazione ie, as welded, machined o rought material
Pulito con solvente.marca e tipo
Non vietato inserire indicazioni multiple ma.
-
8/12/2019 Conferenza ASME Sec.V
36/54
ASME
Limitiamoci ai prodotti ( sviluppatore, penetrante, pulitore..)
Per ogni indicazione (variabile) va prodotto un campione nello statodi preparazione superficiale indicato e con il tipo di pulizia e prodotto
utilizzato..Quindi:
Due prodotti diversi due dimostrazioni
Tre Prodotti diversi quattro dimostrazioni
Quattro prodotti diversi otto dimostrazioni
-
8/12/2019 Conferenza ASME Sec.V
37/54
ASME V
8 dimostrazioni solo alla prima variabile!!!
Capite bene che le procedure considerate standard,discorsive e prolisse non sono gestibili
E soprattutto inutili!
-
8/12/2019 Conferenza ASME Sec.V
38/54
ASME V
Cosa succede in caso di variabili numeriche.. tempi,temperature e luminosit?
Minimum and maximum time periods between steps anddrying aids
Si tratta di indicare dei range temporali dove opportuno.
Esempio:
Final Interpretation: minimo 10 mm max 60mm
-
8/12/2019 Conferenza ASME Sec.V
39/54
ASME V
LA PROCEDURA VA DIMOSTRATA PER UN RANGETEMPORALE NELLAMBITO DI QUANTO RICHIESTO DALLAASME V!
T-676 Interpretation
Se verifichiamo che i difetti sul campione sono visibili dopo 15min,il tempo minimo diventa 15 min,
Se successivamente verifichiamo che sono visibili dopo 45 min
Il Range sar 1545 min
-
8/12/2019 Conferenza ASME Sec.V
40/54
ASME V
T-643 Draying After Preparation
Anche se non specificato come variabile essenziale, iltempo di asciugatura uno step e la sua durata unavariabile. In questo caso larticolo cita:
A minimum period fo time shall be estabilished to ensure
that cleaning solution has been evaporated prior toapplication of the penetrant.
-
8/12/2019 Conferenza ASME Sec.V
41/54
ASME V
T-675 Developing
Non va confuso con linterpretazione!
The time interval shal not exceed that estabilished in theprocedure.
Lapplicazione dello sviluppatore va fatta il prima possibile,linterpretazione dopo non meno di 10 min..
Ma comincia subito dopo lasciugatura dello sviluppatore
-
8/12/2019 Conferenza ASME Sec.V
42/54
ASME V
TEMPERATURA
La temperatura variabile essenziale fuori dal range 5-52C
Tra 5 e 10C si raddoppiano i tempi indicati in tab T-672non si dimostra la procedura
Nel caso, la procedura si dimostra in modo specifico comeindicato in APPENDIX III
-
8/12/2019 Conferenza ASME Sec.V
43/54
ASME V
INTENSITA LUMINOSA
Minimum light intensity una variabile essenziale ma ancheun limite!
A minimum light intensity of 100fc (1000 lux) is required onthe surface to be examined..
Se durante la dimostrazione c pi luce, la procedura dimostrata con il valore reale verificato
-
8/12/2019 Conferenza ASME Sec.V
44/54
ASME V
Come verificato non rilevante:
Luxometro o lampada di nota luminosit netta.
Detratto il fondo!
Se dimostro che con una data lampada ottengo 1000 Lux, edurante la dimostrazione non ho il buio assoluto
la procedura sar dimostrata per una luminosit pari allaluce netta fornita dalla lampada pi il fondo:
-
8/12/2019 Conferenza ASME Sec.V
45/54
ASME V
The light source, technique used, and light level verification isrequired to be demonstrated one time, documented andmantained on file.
Ossia, lutilizzo di unattrezzatura (lampada) la cui capacit diilluminare stata verificata, esenta dalla verifica successiva.
E un gatto che si morde la coda!!
-
8/12/2019 Conferenza ASME Sec.V
46/54
ASME V
-
8/12/2019 Conferenza ASME Sec.V
47/54
ASME V
IL CIRCOLO VIZIOSO SI INTERROMPE SE SEPARIAMOLE ATTIVITA
1) DIMOSTRAZIONE LUMINOSITA LAMPADA
2) DIMOSTRAZIONE PROCEDURA CON LUMINOSITASPECIFICATA
(utilizzo di un luxometro o dimostrazione della procedura in ambiente di luminosit nota)
-
8/12/2019 Conferenza ASME Sec.V
48/54
ASME V
DIMOSTRAZIONE PROCEDURA:
SET VARIABILI ESSENZIALI DEFINITE
RANGE
VALORE
CONDIZIONE
CAMPIONE CON DIFETTI NOTI DIMENSIONI
TIPOLOGIA
-
8/12/2019 Conferenza ASME Sec.V
49/54
ASME V
VARIABILI DESCRITTE NELLE TABELLE E NEGLI ARTICOLI DIRIFERIMENTO
CAMPIONE CON DIFETTI
DIMOSTRARE
CHE I DIFETTI TIPICI SONO VISIBILI
CHE SONO VISIBILI ANCHE QUELLI AL LIMITE INFERIORE DIACCETTABILITA
-
8/12/2019 Conferenza ASME Sec.V
50/54
ASME V
TIPOLOGIA E DIMENSIONE DEI DIFETTI NEI CAMPIONI
NON CI SONO DIRETTI RIFERIMENTI
MA I TEAM LEADER INTERPRETANO:
LA PROCEDURA DEVE ESSERE IN GRADO DI RILEVARE LEINDICAZIONI MINIME DEL CODICE DI RIFERIMENTO
-
8/12/2019 Conferenza ASME Sec.V
51/54
ASME V
QUINDI IL CAMPIONE DEVE AVERE DIFETTI DIDIMENSIONI UGUALI OD INFERIORI ALLE INDICAZIONI
MINIME ACCETTATE DAL CODICE COSTRUTTIVO:
INOLTRE
A SUPPORTO DI CIO
-
8/12/2019 Conferenza ASME Sec.V
52/54
SE-165
10.2 ..A test piece containing one or more discontinuitiesof the smallest relevant size is used.
Lo stesso requisito non viene richiesto dagli altri metodi(MT, UT) per una evidente differenza nel processo fisico dirilievo delle discontinuit
Ma lapproccio dei team leader ASME rimane lo stesso
-
8/12/2019 Conferenza ASME Sec.V
53/54
ASME V
RIGUARDO IL TIPO
NON CI SONO SPECIFICI REQUISITI NE I TEAM LEADERASME SI SONO ESPOSTI..
PERSONALMENTE RITENGO CHE SI DEBBADIMOSTRARE LA CAPACITA DEL METODO DI RILEVAREI DIFETTI TIPICI DEL MATERIALE
-
8/12/2019 Conferenza ASME Sec.V
54/54
ASME V
COME?
PRODURRE UN CAMPIONE CON DIFETTI SIMILI (PT) ?
DIFETTI EQUIVALENTI (UT)?
DIREZIONALITA SIMILE (MT)?
E RESPONSABILITA DEL FABRICANTE