Analysis and Design of Waffle Slabs

64
1 Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar Lecture-11 Analysis and Design of Two-way Slab Systems (Two-way Slab with Beams & Two Way joist Slabs) B P fD Qi Ali Prof. Dr. Qaisar Ali CE 5115 Advance Design of Reinforced Concrete Structures 1 By: Prof Dr. Qaisar Ali Civil Engineering Department NWFP UET Peshawar [email protected] Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar Topics Addressed Moment Coefficient Method for Two way slab with b beams Introduction Cases Moment Coefficient Tables Rif t R i t Prof. Dr. Qaisar Ali Reinforcement Requirements Steps Example 2

description

d

Transcript of Analysis and Design of Waffle Slabs

  • 1Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Lecture-11Analysis and Design of Two-way Slab Systems

    (Two-way Slab with Beams & Two Way joist Slabs)

    B P f D Q i Ali

    Prof. Dr. Qaisar Ali CE 5115 Advance Design of Reinforced Concrete Structures 1

    By: Prof Dr. Qaisar Ali

    Civil Engineering Department

    NWFP UET [email protected]

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Topics Addressedy Moment Coefficient Method for Two way slab with

    bbeams

    y Introduction

    y Cases

    y Moment Coefficient Tables

    R i f t R i t

    Prof. Dr. Qaisar Ali

    y Reinforcement Requirements

    y Steps

    y Example

    2

  • 2Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Topics Addressedy Two-way Joist Slaby Introduction

    y Behavior

    y Characteristics

    y Basic Steps for Structural Design

    Prof. Dr. Qaisar Ali

    y Example

    3

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method (Introduction)

    Two Way Slabs

    z The Moment Coefficient Method included for the first time in1963 ACI Code is applicable to two-way slabs supported onfour sides of each slab panel by walls, steel beams relativelydeep, stiff, edge beams (h = 3hf).

    z Although, not included in 1977 and later versions of ACI code,

    Prof. Dr. Qaisar Ali

    its continued use is permissible under the ACI 318-08 codeprovision (13.5.1). Visit ACI 13.5.1.

    4

  • 3Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method laMa,neg

    Ma,pos

    Two Way Slabs

    y Moments:Ma, neg = Ca, negwula2

    Mb, neg = Cb, negwulb2

    Ma, pos, (dl + ll) = M a, pos, dl + M a, pos, ll = Ca, pos, dl wu, dl la2 + Ca, pos, ll wu, ll la2

    Mb, pos, (dl + ll) = Mb, pos, dl + Mb, pos, ll = Cb, pos, dl wu, dl lb2 + Cb, pos, ll wu, ll lb2

    y Where C C = Tabulated moment coefficients

    Ma,neglb

    Mb,neg Mb,negMb,pos

    Prof. Dr. Qaisar Ali

    y Where Ca, Cb = Tabulated moment coefficientswu = Ultimate uniform load, psf

    la, lb = length of clear spans in short and long directions

    respectively.

    5

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Cases

    Two Way Slabs

    y Moment Coefficient Method: Casesy Depending on the support conditions, several cases are possible:

    Prof. Dr. Qaisar Ali 6

  • 4Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Cases

    Two Way Slabs

    y Moment Coefficient Method: Casesy Depending on the support conditions, several cases are possible:

    Prof. Dr. Qaisar Ali 7

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Cases

    Two Way Slabs

    y Moment Coefficient Method: Casesy Depending on the support conditions, several cases are possible:

    Prof. Dr. Qaisar Ali 8

  • 5Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Cases

    Two Way Slabs

    y Moment Coefficient Method: Casesy Depending on the support conditions, several cases are possible:

    Prof. Dr. Qaisar Ali 9

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabs

    y Moment Coefficient Tables:y Moment Coefficient Tables:

    Prof. Dr. Qaisar Ali 10

  • 6Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabs

    y Moment Coefficient Tables:y Moment Coefficient Tables:

    Prof. Dr. Qaisar Ali 11

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabs

    y Moment Coefficient Tables:y Moment Coefficient Tables:

    Prof. Dr. Qaisar Ali 12

  • 7Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabs

    y Moment Coefficient Tables:y Moment Coefficient Tables:

    Prof. Dr. Qaisar Ali 13

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabs

    y Moment Coefficient Tables:y Moment Coefficient Tables:

    Prof. Dr. Qaisar Ali 14

  • 8Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabs

    y Moment Coefficient Tables:y Moment Coefficient Tables:

    Prof. Dr. Qaisar Ali 15

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabs

    y Load Coefficient Table:y Load Coefficient Table:

    Prof. Dr. Qaisar Ali 16

  • 9Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Maximum spacing and minimum reinforcement

    Two Way Slabs

    requirement:

    z Maximum spacing (ACI 13.3.2):

    smax = 2 hf in each direction.

    z Minimum Reinforcement (ACI 7.12.2.1):

    Asmin = 0.0018 b hf for grade 60.

    Prof. Dr. Qaisar Ali 17

    Asmin 0.0018 b hf for grade 60.

    Asmin = 0.002 b hf for grade 40 and 50.

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Special Reinforcement at exterior corner of Slabz The reinforcement at exterior ends of the slab shall be provided as per ACI

    Two Way Slabs

    z The reinforcement at exterior ends of the slab shall be provided as per ACI13.3.6 in top and bottom layers as shown.

    z The positive and negative reinforcement in any case, should be of a size andspacing equivalent to that required for the maximum positive moment (per footof width) in the panel.

    Prof. Dr. Qaisar Ali 18

  • 10

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method

    Two Way Slabs

    y Stepsy Find hmin = perimeter/ 180 = 2(la + lb)/180

    y Calculate loads on slab (force / area)

    y Calculate m = la/ lby Decide about case of slab,

    Prof. Dr. Qaisar Ali

    Decide about case of slab,

    y Use table to pick moment coefficients,

    y Calculate moments and then design.

    y Apply reinforcement requirements (smax = 2hf, ACI 13.3.2)

    19

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    o e t Coe c e t et od a p e

    y A 100 60, 3-storey commercial building is to be designed.The grids of column plan are fixed by the architect.

    Prof. Dr. Qaisar Ali 20

  • 11

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    o e t Coe c e t et od a p e

    y Complete analysis of the slab is done by analyzing four panels

    Panel I Panel IPanel III Panel III

    Prof. Dr. Qaisar Ali 21

    Panel I Panel I

    Panel II Panel II

    Panel III Panel III

    Panel IV Panel IV

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    p

    y A 100 60, 3-storey commercial building: Sizes and Loads.y Sizes:

    y Minimum slab thickness = perimeter/180 = 2 (20+25)/180 = 6

    However, for the purpose of comparison, take hf = 7

    y Columns = 14 14 (assumed)

    Prof. Dr. Qaisar Ali

    y Beams = 14 20 (assumed)y Loads:

    y S.D.L = Nil ; Self Weight = 0.15 x (7/12) = 0.0875 ksfy L.L = 144 psf ; wu = 0.336 ksf

    22

  • 12

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    y Panels are analyzed using Moment Coefficient MethodCase = 4m = la/lb = 0.8

    Mb,neg Mb,negMb,pos

    Ma,neg

    Ma,pos

    Ma,neg

    Prof. Dr. Qaisar Ali 23

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    y Panels are analyzed using Moment Coefficient MethodCase = 4m = la/lb = 0.8

    Ca,neg = 0.071Cb,neg = 0.029Ca,posLL = 0.048Cb,posLL = 0.020C 0 039

    Prof. Dr. Qaisar Ali 24

    Ca,posDL = 0.039Cb,posDL = 0.016

  • 13

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    y Panels are analyzed using Moment Coefficient MethodCase = 4m = la/lb = 0.8

    Ca,neg = 0.071Cb,neg = 0.029Ca,posLL = 0.048Cb,posLL = 0.020C 0 039

    Prof. Dr. Qaisar Ali 25

    Ca,posDL = 0.039Cb,posDL = 0.016

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    y Panels are analyzed using Moment Coefficient MethodCase = 4m = la/lb = 0.8

    Ca,neg = 0.071Cb,neg = 0.029Ca,posLL = 0.048Cb,posLL = 0.020C 0 039

    Prof. Dr. Qaisar Ali 26

    Ca,posDL = 0.039Cb,posDL = 0.016

  • 14

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    y Panels are analyzed using Moment Coefficient MethodCase = 4m = la/lb = 0.8

    Ca,neg = 0.071Cb,neg = 0.029Ca,posLL = 0.048Cb,posLL = 0.020C 0 039

    Prof. Dr. Qaisar Ali 27

    Ca,posDL = 0.039Cb,posDL = 0.016

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    y Panels are analyzed using Moment Coefficient MethodCase = 4m = la/lb = 0.8

    Ca,neg = 0.071Cb,neg = 0.029Ca,posLL = 0.048Cb,posLL = 0.020C 0 039

    Prof. Dr. Qaisar Ali 28

    Ca,posDL = 0.039Cb,posDL = 0.016

  • 15

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    y Panels are analyzed using Moment Coefficient MethodCase = 4m = la/lb = 0.8

    Ca,neg = 0.071Cb,neg = 0.029Ca,posLL = 0.048Cb,posLL = 0.020C 0 039

    Prof. Dr. Qaisar Ali 29

    Ca,posDL = 0.039Cb,posDL = 0.016

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Moment Coefficient Method: Example

    Two Way Slabs

    y Panels are analyzed using Moment Coefficient Method

    Panel I

    Case = 4m = la/lb = 0.8

    Ca,neg = 0.071Cb,neg = 0.029Ca,posLL = 0.048Cb,posLL = 0.020C 0 039

    Mb,neg Mb,negMb,pos

    Ma,neg

    Ma,pos

    Ma,neg

    Prof. Dr. Qaisar Ali 30

    Ca,posDL = 0.039Cb,posDL = 0.016

    Ma,neg = 9.5 k-ftMa,pos = 6.1 k-ftMb,neg = 6.1 k-ftMb,pos = 3.9 k-ft For slab supported on Spandrals, Mneg,ext = 1/3Mpos

  • 16

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabsy Moment Coefficient Method: Example

    Panel II

    Case = 9m = la/lb = 0.8

    Ca,neg = 0.075Cb,neg = 0.017Ca,posLL = 0.042Cb,posLL = 0.017C 0 029 M MM

    Ma,neg

    y Panels are analyzed using Moment Coefficient Method

    Prof. Dr. Qaisar Ali 31

    Ca,posDL = 0.029Cb,posDL = 0.010

    Ma,neg = 10.1 k-ftMa,pos = 5.1 k-ftMb,neg = 3.6 k-ftMb,pos = 3.1 k-ft

    Mb,neg Mb,negMb,pos

    Ma,pos

    Ma,neg

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabsy Moment Coefficient Method: Example

    Panel III

    Case = 8m = la/lb = 0.8

    Ca,neg = 0.055Cb,neg = 0.041Ca,posLL = 0.044Cb,posLL = 0.019C 0 032

    Mb,neg Mb,negMb,pos

    Ma,neg

    Ma,pos

    Ma,neg

    y Panels are analyzed using Moment Coefficient Method

    Prof. Dr. Qaisar Ali 32

    Ca,posDL = 0.032Cb,posDL = 0.015

    Ma,neg = 7.4 k-ftMa,pos = 5.4 k-ftMb,neg = 8.6 k-ftMb,pos = 3.7 k-ft

  • 17

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabsy Moment Coefficient Method: Example

    Panel IV

    Case = 2m = la/lb = 0.8

    Ca,neg = 0.065Cb,neg = 0.027Ca,posLL = 0.041Cb,posLL = 0.017C 0 026 M MM

    Ma,neg

    y Panels are analyzed using Moment Coefficient Method

    Prof. Dr. Qaisar Ali 33

    Ca,posDL = 0.026Cb,posDL = 0.011

    Ma,neg = 8.7 k-ftMa,pos = 4.9 k-ftMb,neg = 5.7 k-ftMb,pos = 3.2 k-ft

    Mb,neg Mb,negMb,pos

    Ma,pos

    Ma,neg

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabsy Moment Coefficient Method: Exampley Slab analysis summary

    8.77.4

    7.4

    8.6 8.65.43.7

    10.19.5

    9.5

    6.1 6.13.9

    6.1

    Prof. Dr. Qaisar Ali 34

    3.2

    4.95.75.7

    8.7

    3.25.13.6

    10.1

    3.6

  • 18

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Slabsy Moment Coefficient Method: Exampley Slab Reinforcement Details

    A

    C

    C

    C CBA

    A

    C

    C

    B BA

    A= #4 @ 12

    Prof. Dr. Qaisar Ali 35

    A

    BBB

    C

    A

    BA

    C

    @B = #4 @ 6C = #4 @ 4

    Two-Way Joist Slab

    36

  • 19

    y Introduction

    Two-Way Joist

    z A two-way joist system, or waffle slab, comprises evenlyspaced concrete joists spanning in both directions and areinforced concrete slab cast integrally with the joists.

    37

    Joist

    y Introduction

    Two-Way Joist

    z Like one-way joist system, a two way system will be qualifiedto be said as two-way joist system if clear spacing betweenribs (dome width) does not exceed 30 in.

    38

  • 20

    y Introduction

    Two-Way Joist

    39

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Introduction

    Two-Way Joist

    z The joists are commonly formed by using Standard Squaredome forms and the domes are omitted around the columnsto form the solid heads.

    Prof. Dr. Qaisar Ali 40

  • 21

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y IntroductionStandard Dome Data

    Two-Way Joist

    z Standard Dome Data

    z Generally the dome for waffle slab can be of any size. However thecommonly used standard domes are discussed as follows:

    z 30-in 30-in square domes with 3-inch flanges; from which 6-inchwide joist ribs at 36-inch centers are formed: these are available instandard depths of 8, 10, 12, 14, 16 and 20 inches.

    19 i h 19 i h d ith 2 i h fl f hi h

    Prof. Dr. Qaisar Ali

    z 19-inch 19-inch square domes with 2 -inch flanges, from which5-inch wide joist ribs at 24-inch centers are formed. These areavailable in standard depths of 8, 10, 12, 14 and 16 inches.

    41

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y IntroductionStandard Dome Data

    Two-Way Joist

    z Standard Dome Data

    Prof. Dr. Qaisar Ali 42

  • 22

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Behavior

    Two-Way Joist

    z The behavior of two-way joist slab is similar to a two way flatSlab system.

    Prof. Dr. Qaisar Ali

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Characteristics

    Two-Way Joist

    z Dome voids reduce dead load

    z Attractive ceiling (waffle like appearance)

    z Electrical fixtures can be placed in the voids

    z Particularly advantageous where the use of longer spans

    Prof. Dr. Qaisar Ali

    and/or heavier loads are desired without the use ofdeepened drop panels or supported beams.

  • 23

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Basic Steps for Structural Designz Step No 01 (Sizes): Sizes of all structural and non

    Two-Way Joist

    z Step No. 01 (Sizes): Sizes of all structural and nonstructural elements are decided.

    z Step No. 02 (Loads): Loads on structure are determinedbased on occupational characteristics and functionality (referAppendix C of class notes).

    z Step No 03 (Analysis): Effect of loads are calculated on all

    Prof. Dr. Qaisar Ali

    z Step No. 03 (Analysis): Effect of loads are calculated on allstructural elements.

    z Step No. 04 (Design): Structural elements are designed for

    the respective load effects following code provisions.

    45

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Sizesz Minimum Joist Depth

    Two-Way Joist

    z Minimum Joist Depth

    z For Joist depth determination, waffle slabs are considered as flat slab(ACI 13.1.3, 13.1.4 & 9.5.3).

    z The thickness of equivalent flat slab is taken from table 9.5 (c).

    z The thickness of slab and depth of rib of waffle slab can be thencomputed by equalizing the moment of inertia of equivalent flat slab tothat of waffle slab

    Prof. Dr. Qaisar Ali

    that of waffle slab.

    z However since this practice is time consuming, tables have beendeveloped to determine the size of waffle slab from equivalent flat slabthickness.

    46

  • 24

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Sizesz Minimum Joist Depth

    Two-Way Joist

    z Minimum Joist Depth

    z Equivalent Flat Slab Thickness

    z ACI 318-05 Sect. 9.5.3

    z Minimum thickness = ln/33

    Prof. Dr. Qaisar Ali 47

    y Sizesy Minimum Joist Depth

    Two-Way Joist

    y Minimum Joist Depthy Slab and rib depth from equivalent flat slab thickness

    Table 01: Waffle flat slabs (19" 19" voids at 2'-0")-Equivalent thicknessRib + Slab Depths (in.) Equivalent Thickness te (in.)

    8 + 3 8.898 + 4 10.1110 + 3 10.51

    48

    10 + 4 11.7512 + 3 12.12

    12 + 4 13.3814 + 3 13.72

    14 + 4 15.0216 + 3 15.31

    16 + 4 16.64Reference: Table 11-2 of CRSI Design Handbook 2002.

    Note: Only first two columns of the table are reproduced here.

  • 25

    y Sizesy Minimum Joist Depth

    Two-Way Joist

    y Minimum Joist Depthy Slab and rib depth from equivalent flat slab thickness

    Table 02: Waffle flat slabs (30" 30" voids at 3'-0")-Equivalent thicknessRib + Slab Depths (in.) Equivalent Thickness te (in.)

    8 + 3 8.618 + 4 9.7910 + 3 10.18

    10 + 4 11.37

    49

    12 + 3 11.7412 + 4 12.9514 + 3 13.3

    14 + 4 14.5416 + 3 14.85

    16 + 4 16.1220 + 3 17.92

    20 + 4 19.26Reference: Table 11-2 of CRSI Design Handbook 2002.

    Note: Only first two columns of the table are reproduced here.

    y Sizesy Minimum Width of Rib

    Two-Way Joist

    y Minimum Width of Riby ACI 8.11.2 states that ribs shall be not less than 4 inch in width.

    y Maximum Depth of Riby A rib shall have a depth of not more than 3 times the minimum

    width of rib.

    y Minimum Slab Thickness

    50

    y Minimum Slab Thicknessy ACI 8.11.6.1 states that slab thickness shall be not less than one-

    twelfth the clear distance between ribs, nor less than 2 in.

  • 26

    y Loadsy Floor dead load for two-way joist with certain dome size, dome depth can

    Two-Way Joist

    y j , pbe calculated from the table shown for two options of slab thicknesses (3inches and 4 inches).

    Table 03: Standard Dome Dimensions and other Data

    Dome Size Dome Depth (in.) Volume of Void (ft3)

    Floor Dead Load (psf) per slab thickness

    3 inches 4 inches

    8 3.98 71 9010 4 92 80 99

    51

    30-in

    10 4.92 80 9912 5.84 90 10914 6.74 100 11916 7.61 111 12920 9.3 132 151

    19-in

    8 1.56 79 9810 1.91 91 11012 2.25 103 12214 2.58 116 13416 2.9 129 148

    Reference: Table 11-1, CRSI Design Handbook 2002

    y Loadsy Floor dead load (w ) for two way joist can also be

    Two-Way Joist

    y Floor dead load (wdj) for two-way joist can also becalculated as follows:

    36

    8

    3

    30

    Volume of solid:Vsolid = (36 36 11)/1728 = 8.24 ft3Volume of void:Vvoid = (30 30 8)/1728 = 4.166 ft3Total Load of joists per dome:

    52

    Total Load of joists per dome:wdj = (Vsolid Vvoid) conc

    = ( 8.24 4.166) 0.15 = 0.61 kipTotal Load of joists per sq. ft:wdj/ (dome area) = 0.61/ (3 3) = 0.0679 ksf

    = 68 psf 71 psf (from table 03)The difference is because sloped ribs are not considered.

  • 27

    y Loadsy At locations where solid head is present the floor dead load

    Two-Way Joist

    y At locations where solid head is present, the floor dead loadcan be calculated as follows:

    y If, wdj = dead load in joist area

    y Wsh = dead load in solid head area

    = hsolid concy Wdj+sh = {wshb + wdj(l2-b)}/l2

    wdjWdj+sh

    ln

    a a

    Wdj+sh

    53

    dj+sh { sh dj( 2 )} 2

    bl2a a

    y Loadsy Factored loads can be calculated as:

    Two-Way Joist

    y Factored loads can be calculated as:

    y If wL = live load (load/area), theny Load out of solid head region

    wosh = 1.2 wdj + 1.6wL

    y Load in solid head region

    1 2 1 6

    wish wish

    woshWish

    ln

    a a

    Wish

    54

    wish = 1.2wdj+sh+1.6wL bl2a a

    wosh

  • 28

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y AnalysisACI code allows use of DDM for analysis of waffle slabs (ACI

    Two-Way Joist

    z ACI code allows use of DDM for analysis of waffle slabs (ACIR13.1). In such a case, waffle slabs are considered as flatslabs, with the solid head acting as drop panels (ACI 13.1.3).

    Prof. Dr. Qaisar Ali 55

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y AnalysisStatic moment calculation for DDM analysis:

    Two-Way Joist

    z Static moment calculation for DDM analysis:

    wosh

    ln

    woshWish

    lna a

    Wish

    Mosh Mish

    ln

    Prof. Dr. Qaisar Ali 56

    Mosh = woshl2ln2/8 Mish = (wish-wosh)ba2/2

    Mish

    Mo = Mosh + Mish

    b

    l2a a

  • 29

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y DesignDesign of slab for punching shear

    Two-Way Joist

    z Design of slab for punching shear

    z The solid head shall be checked against punching shear.

    z The critical section for punching shear is taken at a section d/2 from faceof the column, where d is the effective depth at solid head.

    Prof. Dr. Qaisar Ali 57

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y DesignDesign of slab for

    Two-Way Joist

    z Design of slab forpunching shear

    z Load on tributary area willcause punch out shear.

    z Within tributary area, twotypes of loads are acting:

    l1

    Prof. Dr. Qaisar Ali

    z Solid head load

    z Joist load

    z Both types shall beconsidered while calculatingpunching shear demand

    58

    l2 d/2

  • 30

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y DesignDesign of slab for punching

    Two-Way Joist

    z Design of slab for punchingshear

    z Total area = l1 l2z Solid area = Asolid

    z Joist part area (Aj) = (l1l2) -Asolidz Critical perimeter area = Acp

    l1

    Prof. Dr. Qaisar Ali

    z Critical perimeter area Acp

    z Vu =Ajwosh+ (Asolid Acp) wishz Where,

    wosh = joist part load

    wish = load inside solid head

    59

    l2 d/2

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Designz Shear Strength of Slab in punching shear:

    Two-Way Joist

    Shear Strength of Slab in punching shear:

    z Vn = Vc + Vs

    z Vc is least of:

    z 4 (fc)bod

    z (2 + 4/c) (fc)bod

    z {(sd/bo +2} (fc)bod

    Prof. Dr. Qaisar Ali 60

    c = longer side of column/shorter side of column

    s = 40 for interior column, 30 for edge column, 20 for corner columns

  • 31

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Designz Design of Joist for Beam Shear:

    Two-Way Joist

    Design of Joist for Beam Shear:

    z Beam shear Demand

    z Beam shear is not usually a problem in slabs including waffle slabs.However for completion of design beam shear may also bechecked. Beam shear can cause problem in case where largerspans and heavier loads with relatively shallow waffle slabs areused.

    Prof. Dr. Qaisar Ali 61

    z The critical section for beam shear is taken at a section d from faceof the column, where d is the effective depth at solid head.

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Designz Design of Joist for Beam Shear:

    Two-Way Joist

    g

    z Beam shear capacity of concrete joist

    z Vn = Vc + Vs

    z Vc is least of:

    z 2 (fc)bribd

    z Vs = Avfy/bribs

    Stirrup

    Prof. Dr. Qaisar Ali 62

    z If required, one or two single legged stirrups are provided in the rib to increase the shear capacity of waffle slab.

  • 32

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y DesignDesign for Flexure

    Two-Way Joist

    z Design for Flexure

    z The design of waffle slab is done by usual procedures.

    z However, certain reinforcement requirements apply discussed next.

    Prof. Dr. Qaisar Ali 63

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y ACI recommendations on reinforcement requirement of waffle slab:

    Two-Way Joist

    requirement of waffle slab:

    z ACI 10.6.7 states that if the effective depth d of a beam orjoist exceeds 36 in., longitudinal skin reinforcement shall beprovided as per ACI section 10.6.7.

    z According to ACI 13.3.2, for cellular or ribbed constructionreinforcement shall not be less than the requirements of ACI

    Prof. Dr. Qaisar Ali

    reinforcement shall not be less than the requirements of ACI7.12.

    z As per ACI 7.12, Spacing of top bars cannot exceed 5h or18 inches.

    64

  • 33

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y ACI recommendations on reinforcement requirement of waffle slab:

    Two-Way Joist

    requirement of waffle slab:

    Prof. Dr. Qaisar Ali 65

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Other important points:The amount of reinforcement and if necessary the top slab

    Two-Way Joist

    z The amount of reinforcement and, if necessary, the top slabthickness can be changed to vary the load capacities fordifferent spans, areas, or floors of a structure.

    z Each joist rib contains two bottom bars. Straight bars aresupplied over the column centerlines for negative factoredmoment.

    Prof. Dr. Qaisar Ali 66

    Bottom bar

  • 34

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Other important points:For layouts that do not meet the standard 2 feet and 3 feet

    Two-Way Joist

    z For layouts that do not meet the standard 2-feet and 3-feetmodules, it is preferable that the required additional width beobtained by increasing the width of the ribs framing into thesolid column head.

    z The designer should sketch out the spacing for a typical paneland correlate with the column spacing as a part of the early

    Prof. Dr. Qaisar Ali

    p g p yplanning.

    67

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Example: Design the slab system of hall shown in figure as waffleslab, according to ACI 318. Use Direct Design Method for slab

    Two-Way Joist

    analysis.z fc = 4 ksi

    z fy = 60 ksi

    z Live load = 100 psf

    Prof. Dr. Qaisar Ali 68

  • 35

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Solution:z A 108 144 building divided into twelve (12) panels supported at

    Two-Way Joist

    z A 108 144 building, divided into twelve (12) panels, supported attheir ends on columns. Each panel is 36 36.

    z The given slab system satisfies all the necessary limitations for DirectDesign Method to be applicable.

    Prof. Dr. Qaisar Ali 69

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Step No 01: SizesColumns

    Two-Way Joist

    z Columns

    z Let all columns be 18 18.

    z Slab

    z Adopt 30 30 standard dome.

    z Minimum equivalent flat slab thickness (hf) can be found using ACI Table9 5 (c):

    Prof. Dr. Qaisar Ali

    9.5 (c):

    z Exterior panel governs. Therefore,

    hf = ln/33

    = [{36 (2 18/2)/12}/33] 12 = 12.45

    70

  • 36

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Step No 01: SizesSlab

    Two-Way Joist

    z Slab

    z The closest depth of doom that will fulfill the requirement of equivalentthickness of flat slab equal to 12.45 is 12 in. with a slab thickness of 4 in. for a dome size of 30-in.

    Table: Waffle flat slabs (30" 30" voids at 3'-0")-Equivalent thickness

    Rib + Slab Depths (in.) Equivalent Thickness te (in.)

    8 + 3 8.618 + 4 9.79

    Prof. Dr. Qaisar Ali 71

    10 + 3 10.1810 + 4 11.3712 + 3 11.74

    12 + 4 12.9514 + 3 13.3

    14 + 4 14.5416 + 3 14.85

    16 + 4 16.1220 + 3 17.92

    20 + 4 19.26Reference: Table 11-2 of CRSI Design Handbook 2002.

    Note: Only first two columns of the table are reproduced here.

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Step No 01: SizesPlanning of Joist layout

    Two-Way Joistl = 36-0 = 432Standard module = 36 36

    z Planning of Joist layout No. of modules in 36-0:n = 432/36 = 12

    Planning:First module is placed on interiorcolumn centerline and providedtowards exterior ends of panel.In this way, width of exterior joistcomes out to be 15.

    Prof. Dr. Qaisar Ali 72

  • 37

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Step No 01: SizesSolid Head

    Two-Way Joist

    z Solid Head

    z Solid head dimension from column centerline = l/6 = 36/6 = 6

    z Total length of solid head= 2 6 = 12z As 3 3 module is selected, therefore 4 voids will make an interior solid

    head of 12.5 12.5.z Depth of the solid head = Depth of standard module = 12 + 4.5 = 16.5

    Prof. Dr. Qaisar Ali 73

    Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    y Step No 02: Loadsz Floor (joist) dead load (wdj) = 109 psf = 0 109 ksf

    Two-Way Joist

    z Floor (joist) dead load (wdj) 109 psf 0.109 ksf

    Table: Standard Dome Dimensions and other Data

    Dome Size Dome Depth (in.) Volume of Void (ft3)

    Floor Dead Load (psf) per slab thickness

    3 inches 4 inches

    30-in

    8 3.98 71 9010 4.92 80 9912 5.84 90 10914 6.74 100 11916 61 111 129

    Prof. Dr. Qaisar Ali 74

    16 7.61 111 12920 9.3 132 151

    19-in

    8 1.56 79 9810 1.91 91 11012 2.25 103 12214 2.58 116 13416 2.9 129 148

    Reference: Table 11-1, CRSI Design Handbook 2002

  • 38

    y Step No 02: Loadsy Floor (joist) dead load (wdj) = 109 psf = 0 109 ksf

    Two-Way Joist

    y Floor (joist) dead load (wdj) 109 psf 0.109 ksf

    y Solid Head dead load (wsh) = {(12 + 4.5)/12} 0.15 = 0.206 ksf

    y Wdj+sh = {wshb + wdj(l2-b)}/l2= {0.20612.5 + 0.109 (36 12.5)}/36= 0.143 ksf

    wdjWdj+sh

    l

    a a

    Wdj+sh

    75

    ln

    b = 12.5l2a = 5.25 a

    y Step No 02: Loadsy w = 100 psf = 0 100 ksf

    Two-Way Joist

    y wL = 100 psf = 0.100 ksf

    y Load out of solid head region

    wosh = 1.2 wdj + 1.6wL

    = 1.20.109 + 1.60.100= 0.291 ksf

    wish wish

    76

    y Load in solid head region

    wish = 1.2wdj+sh+1.6wL

    = 1.2 0.143 + 1.6 0.100 = 0.33 ksf

    bl2a a

    wosh

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Interior Frame)

    Two-Way Joist

    z Step 1: Marking E-W Interior Frame:

    l 36 0

    l2 = 36-0

    l1 = 36-0ln = 34-6

    Prof. Dr. Qaisar Ali 77

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Interior Frame)

    Two-Way Joist

    z Step 01: Marking E-W Interior Frame

    z Design Span of frame (c/c) = l1 = 36

    Design Length of frame = ln = 36 (2 18/2)/12 = 34.5

    Width of frame = l2 = 36

    Half column strip width = (Shorter span)/ 4 = 36/4 = 9

    Prof. Dr. Qaisar Ali 78

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Interior Frame)

    Two-Way Joist

    z Step 2: Marking Column and Middle Strips

    MS/2 = 9-0

    a = 5-3 CS/2 = 9-0

    CS/2 = 9-0

    a 5 -3

    b= 12-6

    CS/2 = Least of l1/4 or l2/4

    l /4 = 36/4 = 9

    MS/2 = 9-0

    Prof. Dr. Qaisar Ali 79

    l2/4 = 36/4 = 9

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Interior Frame)

    Two-Way Joist

    z Step 03: Static Moment Calculation

    z Mosh (outside head) = woshl2ln2/8

    = 0.291 36 34.52/8 = 1557.56 ft-k

    Mish (solid head) = (wish wosh) ba2/2

    = (0.330.291)12.55.252/2 = 6.70 ft-k

    Mo (total static moment) = Mosh + Mish = 1557.56 + 6.70 = 1564.26 ft-k

    Note: Since normally, Mish is much smaller than Mosh the former can be conveniently ignored in design calculations

    Prof. Dr. Qaisar Ali 80

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Interior Frame)

    Two-Way Joist

    z Step 04: Longitudinal distribution of Total static moment (Mo).

    Prof. Dr. Qaisar Ali 81

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Interior Frame)

    Two-Way Joist

    z Step 05: Lateral Distribution of Longitudinal moment (L.M).

    INT36 =0 {no interior beams}

    l2/l1 = 36/36 = 1

    INT36l2/l1 = 0

    Prof. Dr. Qaisar Ali 82

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Exterior Frame)

    Two-Way Joist

    z Step 01: Marking E-W exterior Frame

    l 36 0l1 = 36-0ln = 34-6

    l2 = 18-0 + (9/12) = 18.75

    Prof. Dr. Qaisar Ali 83

    2 ( )

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Exterior Frame)

    Two-Way Joist

    z Step 01: Marking E-W exterior Frame

    z Design Span of frame (c/c) = l1 = 36

    Design Length of frame = ln = 36 (2 18/2)/12 = 34.5

    Width of frame = l2 = 9 + 9 + (9/12) = 18.75

    Half column strip width = (Shorter span)/ 4 = 36/4 = 9

    Prof. Dr. Qaisar Ali 84

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Exterior Frame)

    Two-Way Joist

    z Step 02: Marking Column and Middle Strips

    l 36 0l1 = 36-0ln = 34-6

    CS/2 = Least of l1/4 or l2/4

    l /4 = 36/4 = 9

    MS/2 = 9-0a = 5 3

    Prof. Dr. Qaisar Ali 85

    CS/2 = 9-0l2/4 = 36/4 = 9 a = 5 -3

    b= 7-0

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Frame Analysis (E-W Exterior Frame)

    Two-Way Joist

    z Step 03: Static Moment Calculation

    z Mosh (outside head) = woshl2ln2/8

    = 0.291 18.75 34.52/8 = 811.78 ft-k

    Mish (solid head) = (wish wosh) ba2/2

    = (0.330.291)75.252/2 = 3.76 ft-k

    Mo (total static moment) = Mosh + Mish = 811.78 + 3.76 = 815.54 ft-k

    Note: Since normally, Mish is much smaller than Mosh the former can be conveniently ignored in design calculations

    Prof. Dr. Qaisar Ali 86

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Analysis

    Two-Way Joist

    z Step 04: Longitudinal distribution of Total static moment (Mo).

    Prof. Dr. Qaisar Ali 87

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Analysis

    Two-Way Joist

    z Step 05: Lateral Distribution of Longitudinal moment (L.M)[Refer to ACI 13.6.4 to ACI 13.6.6].

    z EXT36 =0 {no exterior beams}

    z l2/l1 = 36/36 = 1

    z EXT36l2/l1 = 0

    Prof. Dr. Qaisar Ali 88

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 03: Analysis

    Two-Way Joist

    z Analysis of N-S Interior and Exterior Frame will be same as E-W respectiveframes due to square panels.

    N-S Exterior Frame

    N-S Interior Framel2 = 36-0

    l2 = 18-9

    Prof. Dr. Qaisar Ali 89

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 04: Design

    Two-Way Joist

    z For E-W Interior slab strip:

    z davg = 12 + 4.5 1 (concrete cover) 0.75 (avg. bar dia) = 14.75g

    z Asmin = 0.0018bte (Where te = equivalent flat slab thickness)

    Asmin = 0.0018 12 12.95 = 0.279 in2

    z Now, Equation used to calculate () in table below is as follows:

    Mu = fybdavg2{1 0.59fy/fc} = 0.9601214.752{1 0.5960/4}

    z After solving the above equation for , we get:

    = [140980.5 {(140980.5)2 (4 1247677 Mu 12)}]/2(1247677).(A)

    Prof. Dr. Qaisar Ali 90

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 04: Design

    Two-Way Joist

    z For E-W Interior slab strip:

    Prof. Dr. Qaisar Ali 91

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 04: Design

    Two-Way Joist

    z For E-W exterior slab strip:

    z davg = 12 + 4.5 1 0.75 = 14.75 g

    z Asmin = 0.0018bte (Where te = equivalent flat slab thickness)

    Asmin = 0.0018 12 12.95 = 0.279 in2

    z Now, Equation used to calculate () in table below is as follows:

    Mu = fybdavg2{1 0.59fy/fc} = 0.9601214.752{1 0.5960/4}

    z After solving the above equation for , we get:

    = [140980.5 {(140980.5)2 (4 1247677 Mu 12)}]/2(1247677).(A)

    Prof. Dr. Qaisar Ali 92

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 04: Design

    Two-Way Joist

    z For E-W exterior slab strip:

    Prof. Dr. Qaisar Ali 93

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 04: Design

    Two-Way Joist

    z Design of N-S Interior and Exterior Frame will be same as E-W respective frames due to square panels and also for thereason that davg is used in design.

    Prof. Dr. Qaisar Ali 94

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 04: Design

    Two-Way Joist

    z Note: For the completion of design problem, the waffle slabshould also be checked for beam shear and punching shear.

    Prof. Dr. Qaisar Ali 95

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 05: Detailing (E-W Frames)

    Two-Way Joist

    #6 @ 12 #6 @ 6 #6 @ 6 #6 @ 12

    Prof. Dr. Qaisar Ali 96#6 @ 12 #6 @ 6 #6 @ 6 #6 @ 12

    #6 @ 18 #6 @ 18 #6 @ 18 #6 @ 18

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 05: Detailing (N-S Frames)

    Two-Way Joist

    #6 @ 12#6 @ 18#6 @ 12

    #6 @ 6#6 @ 18#6 @ 6

    #6 @ 6#6 @ 18#6 @ 6

    Prof. Dr. Qaisar Ali 97

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 05: Detailing (E-W Interior Frame)

    Two-Way Joist

    #6 @ 6 c/c

    18-0

    Column Strip (Interior Frame); section taken over support

    #6 @ 12 c/c2 #7 Bars

    #6 @ 12 c/c

    Prof. Dr. Qaisar Ali 98Column Strip (Exterior Frame); section taken over support2 #7 Bars

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 05: Detailing (E-W Interior Frame)

    Two-Way Joist

    #6 @ 18 c/c

    18-0

    Middle Strip (Interior Frame); Section taken over column line

    #6 @ 18 c/c2 #7 Bars

    #6 @ 18 c/c

    Prof. Dr. Qaisar Ali 99Middle Strip (Exterior Frame); Section taken over column line2 #7 Bars

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 05: Detailing (E-W Exterior Frame)

    Two-Way Joist

    #6 @ 6 c/c

    9-0

    Column Strip (Interior Frame); section over support2 #7 Bars

    #6 @ 12 c/c

    Prof. Dr. Qaisar Ali 100

    Column Strip (Exterior Frame); section over support2 #7 Bars

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    Two Way Joisty Step No 05: Detailing (E-W Exterior Frame)

    Two-Way Joist

    #6 @ 18 c/c

    9-0

    Middle Strip (Interior Frame) ; section over support2 #7 Bars

    #6 @ 18 c/c

    Prof. Dr. Qaisar Ali 101

    Middle Strip (Exterior Frame); section over support2 #7 Bars

  • Department of Civil Engineering, N-W.F.P. University of Engineering and Technology Peshawar

    The End

    Prof. Dr. Qaisar Ali 102