Post on 01-Sep-2018
Contents
MOBILESCOPE
MAF-GMAirway Mobilescope................................................ENF-060
ENF-065
VIDEOSCOPES
ENF-VHENF-V3Rhino-Laryngo Videoscope.....................................ENF-110
ENF-115
ENF-VQRhino-Laryngo Videoscope.....................................ENF-140
ENF-145
ENF-V2Rhino-Laryngo Videoscope.....................................ENF-160
ENF-VT2Rhino-Laryngo Videoscope.....................................ENF-180
FIBERSCOPES
ENF-GP Rhino-Laryngo Fiberscope......................................ENF-205
ENF-P4 Rhino-Laryngo Fiberscope......................................ENF-210
ENF-XPRhino-Laryngo Fiberscope......................................ENF-215
ENF-T3 Rhino-Laryngo Fiberscope......................................ENF-220
ET INSTRUMENTS
ET Instrumentsfor ENF-VT2 and ENF-T3 ........................................ENF-330
Monopolar Instrumentsfor ENF-VT2.............................................................ENF-335
2001Flexible ENT Endoscopes, ENF- 000
MAF-GMAirway Mobilescope
Mobile airway management,
anywhere, anytime
2003Flexible ENT Endoscopes, ENF- 060
Complete standalone designIncorporating a monitor, LED light source, battery andrecording device in a single unit, this versatile endoscopeenables observation without peripherals or cables, providingit with a level of mobility that allows it be used almostanywhere.
2.5-inch monitorThe scope incorporates a 2.5-inch monitor to enableobservation and control operations in a single view. Themonitor can be tilted to adjust the orientation to suit theoperator or to share the view with other people.
Still image/movie recording and managementBoth still images and movies can be recorded on an xD-Picture Card for easy referencing and management. Imagescan be transferred easily to a PC for additional processing.
White LED light sourceThe built-in light source uses a long-life white LED thatfacilitates clearer, brighter observation than a traditionalhalogen light.
W7055190_6-02004
MAF-GM LF-GP +MAJ-524
MAF-GMAirway Mobilescope (cont.)
Portable flexible endoscope with expanded viewing andrecording capability.
Oberservation
Recording
Portability
2005Flexible ENT Endoscopes, ENF- 065
Airway Mobilescope MAF-GM
Mobilescope “MAF-GM”,
E0497560
N3058830
Europe
other territories
Delivery includes:
Endoscope, sterilization cap MAJ-1538, cap MH-364 (6 pcs.),
suction valve MAJ-209 (20 pcs.), cleaning brushes BW-15SH,
BW-7B, MH-507, suction cleaning adapter MAJ-1077,
rechargeable battery (2 pcs.), xD Picture Card
N3101092 Lithium ion battery “LI-50B”,
2 pcs.
Technical DataOptical system
Field of view ..................................................................90°
Direction of view ..................................0° (forward viewing)
Depth of field........................................................4–50 mm
Insertion tube
Distal end outer diameter ........................................3.9 mm
Insertion tube outer diameter...................................4.1 mm
Insertion section working length .............................600 mm
Channel
Channel inner diameter ...........................................1.5 mm
Bending section
Angulation range.....................................................120° up
120° down
Size
Total length ............................................................910 mm
Weight (incl. battery and memory card).......................540 g
Camera
Batteries......................................Lithium ion battery LI-50B
= 3.7 V, 925 mAh
Battery life .....................................approx. 300 full charges
Standard voltage........................................= 3.7 V, 880 mA
Operating hours ...........................................approx. 60 min
Dimensions .............................................102 x 69 x 37 mm
Camera section rotation ........both 90° from neutral position
LCD display tilt.........................................................0–120°
Common specifications
Classification acc. to 93/42/EEC..............................Class IIa
EMC ...........................................................group 1, class B
Protection against electric shock ..........type BF applied part
Environment
Operation..............................................................10–40° C
30–85% relative humidity
700–1060 hPa
Transportation and storage..................................-47–70° C
10–95% relative humidity
700–1060 hPa
Accessories
N2639830
WA23070A
Sterilization cap “MAJ-1538”
Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
A0453 Cleaning brush “MH-507”,
N1029300
for channel-opening
Suction cleaning adapter “MAJ-1077”
026447 Cleaning brush “BW-7B”,
for suction channel
026439 Cleaning brush “BW-15SH”,
for suction channel
Attachments
A029006A Suction valve “MAJ-209”,
single use, 20 pcs.
E0489002 Cap “MH-364”
W7055190_6-02006
ENF-VHENF-V3
Rhino-Laryngo Videoscope
Two Scopes Cover Most
Examination Needs
ENF-VH, for more detailed images achieved by HD
ENF-V3, crisp, high-resolution images with a distal enddiameter of only 2.6 mm
2007Flexible ENT Endoscopes, ENF- 110
Astounding image quality:With advances in CCD technology, ENF-VH delivery HDimages, which show even greater detail for examinations.
Surprisingly slim diameter:The distal end of the ENF-V3 scope is only 2.6 mm indiameter. Also, the difference between diameters of thedistal end and the insertion tube is minimal. This makesinsertion into tight nasal passages much easier. And with theCCD chip’s improvement, even this slim scope deliversexceptional image quality.
Exceptional luminosity:Although it has a small diameter, the scope still illuminates abroad area, providing a detailed image of any lesions withinthe field of view. This exceptional luminosity is especiallyuseful when observing with NBI.
Wide field of view:The ENF-VH has a viewing angle of 110°. And with HDresolution and exceptional illumination, every corner of thefield can be thoroughly inspected.
Pre-freeze function:The scope continuously captures still images even beforeyou push the pre-freeze button. When you press the button,the system automatically selects the sharpest image amongseveral.
NBI (Narrow Band Imaging):During endoscopic observation, NBI enhances visualizationof the capillary network and mucosal morphology.
W7055190_6-02008
ENF-V3 ENF-VH
Rhino-Laryngo Videoscope ENF-VH
N3828360 Videoscope “ENF-VH”
Delivery includes:
Endoscope, ETO cap
Technical DataOptical system
Field of view ................................................................110°
Direction of view ..................................0° (forward viewing)
Depth of field........................................................5–50 mm
Insertion section
Distal end outer diameter ........................................3.9 mm
Insertion tube outer diameter...................................3.6 mm
Insertion section working length .............................300 mm
Bending section
Angulation range.....................................................130° up
130° down
Size
Total length ............................................................510 mm
Common specifications
Classification acc. to 93/42/EEC..............................Class IIa
EMC ...........................................................group 1, class B
Protection against electric shock..........Type BF applied part
Environment
Operation..............................................................10–40° C
30–85% relative humidity
700–1060 hPa
Transportation and storage..................................-47–70° C
10–95% relative humidity
700–1060 hPa
Rhino-Laryngo Videoscope ENF-V3
N3828260 Videoscope “ENF-V3”
Delivery includes:
Endoscope, ETO cap
Technical DataOptical system
Field of view ..................................................................90°
Direction of view ..................................0° (forward viewing)
Depth of field.....................................................3.5–50 mm
Insertion section
Distal end outer diameter ........................................2.6 mm
Insertion tube outer diameter...................................2.9 mm
Insertion section working length .............................300 mm
Bending section
Angulation range.....................................................130° up
130° down
Size
Total length ............................................................510 mm
Common specifications
Classification acc. to 93/42/EEC..............................Class IIa
EMC ...........................................................group 1, class B
Protection against electric shock..........Type BF applied part
Environment
Operation..............................................................10–40° C
30–85% relative humidity
700–1060 hPa
Transportation and storage..................................-47–70° C
10–95% relative humidity
700–1060 hPa
ENF-VH/ENF-V3Rhino-Laryngo Videoscope
(cont.)
2009Flexible ENT Endoscopes, ENF- 115
Instrument Tray for Flexible Endoscopes
WA05991A Instrument tray,
for flexible endoscopes of CHF, CYF, ENF, HYF, LF,
and URF series,outer dimensions: 531 x 79 x 255 mm
Accessories
028616 Mouthpiece “MA-651”
A2328 ETO cap “MB-156”
WA23070A Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
VISERA ELITE Video System Center
OTV-S190 Video processor
For details, see sheets EQ-050/-060/-065.
W7055190_6-02010
MENU CUSTOM WHT BAL
MENMORY
MENU ENTER
RDY/BUSY
COMPLETE
STOPRESET
1 2
“Chip-on-the-Tip” for High-Resolution Images
The ENF-VQ features a distally mounted CCD that delivershigh-resolution and full-screen images enabling you toobserve minute otorhinolaryngeal details.
Full-Screen Images: Clear and Bright in Every Corner
Full-screen images make observation much easier. Withlarge-size images that are clear and bright even in thecorners, the ENF-VQ may make it possible to detect minutedetails that would not have been previously detected.
Narrow Band Imaging
When used with the EVIS EXERA II System, the ENF-VQ iscompatible with Narrow Band Imaging (NBI). NBI is apowerful image processing function that exploits particularcharacteristics resulting from the interaction of light withtissue and enhances visualization of mucosal surfaces. Whencombined with ENF-VQ’s bright full-screen images, the resultis remarkably clear views of anatomical structures and finecapillary patterns of the mucous membranes, which arenormally difficult to distinguish.
W7055190_6-02012
ENF-VQRhino-Laryngo Videoscope (cont.)
The ENF-VQ provides high-resolution, full-screen imagesthat are clear and bright throughout the entire field. Thisoutstanding imaging capability is achieved without sacrificingthe slim, compact design, enabling you to use thisendoscope in a variety of patients.
Pursuing picture quality whithout compromising performanceor versatility, the ENF-VQ brings unprecedented imaging toyour ENT practice.
2013Flexible ENT Endoscopes, ENF- 145
Rhino-Laryngo Videoscope ENF-VQ
WA91550A Videoscope “ENF-VQ”
Delivery includes:
Videoscope and ETO cap
Technical Data
Field of view.........................................................................90°
Depth of field ..............................................................5–50 mm
Outer diameter (distal tip)...............................................3.9 mm
Outer diameter (insertion tube).......................................3.6 mm
Working length..............................................................300 mm
Total length...................................................................528 mm
Maximum angulation (up) ...................................................130°
Maximum angulation (down)...............................................130°
For light-guide adapters, see sheet ACC-170.
Instrument Tray for Flexible Endoscopes
WA05991A Instrument tray,
for flexible endoscopes of CHF, CYF, ENF, HYF, LF,
and URF series,outer dimensions: 531 x 79 x 255 mm
Accessories
A2328 ETO cap “MB-156”
WA23070A Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
Video Systems
E0497502 Video system “OTV-SI”,
set, with ENF-VQ
For details,
see sheets EQE-006/-007.
OTV-S190 VISERA ELITE video system
OTV-S7
For details, see sheets EQ-050/-060/-065.
VISERA video system
For details, see sheets EQ-150/-160/-170.
CV-180 EVIS EXERA II video system
For details, see sheets EQ-110/-120/-130.
W7055190_6-02014
LAMP
1 2 3
CV-180B
NBIHDTV0 +–
MENU CUSTOM WHT BAL
MENMORY
MENU ENTER
RDY/BUSY
COMPLETE
STOPRESET
1 2
ENF-V2Rhino-Laryngo Videoscope
The ENF-V2 not only delivers some of the brightest, clearestimages available from a videoscope, it boasts a revolutionary3.2 mm ultra-thin diameter. A simultaneous multicolor CCDbuilt into the tip provides color-resistant, moiré-free images.
Focus-free high resolution imaging
3.2 mm ultra-slim diameter
Easy insertion while enabling clearer observation
2015Flexible ENT Endoscopes, ENF- 160
Rhino-Laryngo Videoscope ENF-V2
Videoscope “ENF-V2”,
WA91530A
WA91570A
European version
UK version
Delivery includes:
Endoscope, ETO cap and carrying case
Technical DataField of view.........................................................................90°
Depth of field ..............................................................5–50 mm
Outer diameter (distal tip)...............................................3.2 mm
Outer diameter (insertion tube).......................................3.4 mm
Working length..............................................................300 mm
Total length...................................................................528 mm
Maximum angulation (up) ...................................................130°
Maximum angulation (down)...............................................130°
For light-guide adapters, see sheet ACC-170.
Instrument Tray for Flexible Endoscopes
WA05991A Instrument tray, for flexible endoscopes of CHF, CYF, ENF, HYF, LF,
and URF series,outer dimensions: 531 x 79 x 255 mm
Accessories
A2328 ETO cap “MB-156”
WA23070A Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
Video Systems
E0497349 Video system “OTV-SI”,
set, with ENF-V2
For details,
see sheets EQE-006/-007.
OTV-S190 VISERA ELITE video system
OTV-S7
For details, see sheets EQ-050/-060/-065.
VISERA video system
For details, see sheets EQ-150/-160/-170.
CV-180 EVIS EXERA II video system
For details, see sheets EQ-110/-120/-130.
W7055190_6-02016
1 2 3
CV-180B
NBIHDTV0 +–
LAMP
MENU CUSTOM WHT BAL
MENMORY
MENU ENTER
RDY/BUSY
COMPLETE
STOPRESET
1 2
ENF-VT2Rhino-Laryngo Videoscope
The ENF-VT2 features outstanding observation capabilityand a reliable treatment performance. The high image qualitycombined with a close focus feature delivers brightest andclearest images for higher accuracy.
Superior chip-on-the-tip technology
2.0 mm viewing distance
Large working channel with 2 mm in diameter
NBI compatible
Compatible with laser and electrosurgery treatments
2017Flexible ENT Endoscopes, ENF- 180
Rhino-Laryngo Videoscope ENF-VT2
Videoscope “ENF-VT2”,
WA91540A
WA91541A
European version
UK version
Delivery includes:
Endoscope, biopsy valve MAJ-2101 (20 pcs.), biopsy valve
MD-4953 (10 pcs.), suction valve MAJ-2072 (10 pcs.), suction
valve MAJ-2092 (20 pcs.), suction cleaning adapter MAJ-222,
cleaning brushes MH-507, BW-15B, and ETO cap
Technical Data
Field of view.........................................................................90°
Direction of view.....................................................................0°
Depth of field ..............................................................2–40 mm
Outer diameter (distal tip)...............................................4.8 mm
Outer diameter...............................................................4.9 mm
Working length..............................................................365 mm
Total length...................................................................635 mm
Maximum angulation (up) ...................................................130°
Maximum angulation (down)...............................................130°
Instrument channel .....................................................Ø 2.0 mm
Accessories
For light-guide adapters, see sheet ACC-170.
A2328 ETO cap “MB-156”
A0453
026799
Cleaning brush “MH-507”,
for channel-opening
Cleaning brush “BW-15B”,
028962
for instrument
channel
Suction cleaning adapter “MAJ-222“
WA23070A Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
Instrument Tray for Flexible Endoscopes
WA05991A Instrument tray,
for flexible endoscopes of CHF, CYF, ENF, HYF, LF,
and URF series,outer dimensions: 531 x 79 x 255 mm
Attachments
A029006A2
A02905A2
Suction valve,
“MAJ-209”, single use, 20 pcs.
“MAJ-207”, reusable, 10 pcs.
A91221
A91243
Biopsy valve,
“MAJ-210”, single use, 20 pcs.
“MD-495”, reusable, 10 pcs.
For Endo-Therapy instruments, see sheet ENF-330.
Video Systems
E0497453 Video system “OTV-SI”,
set, with ENF-VT2
For details,
see sheets EQE-006/-007.
OTV-S190 VISERA ELITE video system
For details, see sheets EQ-050/-060/-065.
OTV-S7
CV-180
VISERA video system
For details, see sheets EQ-150/-160/-170.
EVIS EXERA II video system
For details, see sheets EQ-110/-120/-130.
1 Only available in Europe and other countries (except Asia)2 Not available in some sales territorries3 Only available in Asia
W7055190_6-02018
LAMP
ENF-GPRhino-Laryngo Fiberscope
The ENF-GP is a complete, all-in-one portable solution forrhino-laryngoscopy. The diagnostic rhino-laryngo fiberscopecan be used either with a standard light-guide cable or withan optional miniature light source. The miniature light sourceEndoLED provides enormous bright and whitish light to en-sure clear visualization of the vocal cords everywhere insideand outside the medical facility.
Standard connector for most common light-guide cables
Superior image size and resolution
Extremely bright LED miniature light source EndoLED for more flexibility
Advanced light distribution system
2019Flexible ENT Endoscopes, ENF- 205
Rhino-Laryngo Fiberscope ENF-GP
WA99030A Fiberscope “ENF-GP”
Delivery includes:
Endoscope, ETO cap, light-guide adapter MAJ-900,
and carrying case
Technical dataField of view.........................................................................85°
Direction of view.....................................................................0°
Depth of field ..............................................................5–50 mm
Outer diameter (distal tip)...............................................3.4 mm
Outer diameter...............................................................3.6 mm
Working length..............................................................300 mm
Total length...................................................................530 mm
Maximum angulation (up) ...................................................130°
Maximum angulation (down)...............................................130°
Light Source EndoLED
WA91502A Light source “EndoLED”,
for flexible endoscopes
for rechargeable batteries
(requires 2 batteries of WA91505A),
with battery status indicator (lasts up to 3 hrs.)
Technical DataDimensions .....................................70 (W) x 90 (H) x 35 (D) mm
Weight (without batteries)..................................................119 g
WA91505A Battery,
AA type,
rechargeable,
4 pcs.
Light-Guide Adapter
A70982A Light-guide adapter “MAJ-900”,
OES light-guide cable to ENF-GP
WA03200A Light-guide cable,
size S,
plug type,
3 m,
CF type
For light-guide adapters,
see sheet ACC-150.
Instrument Tray for Flexible Endoscopes
WA05991A Instrument tray,
for flexible endoscopes of CHF, CYF, ENF, HYF, LF,
and URF series,outer dimensions: 531 x 79 x 255 mm
Accessories
A2328
WA23070A
ETO cap “MB-156”
Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
W7055190_6-02020
ENF-P4Rhino-Laryngo Fiberscope
The diagnostical rhino-laryngo fiberscope ENF-P4 representsthe golden standard for a safe rhino-laryngo diagnosis. Due to the latest fiber optic technology the ENF-P4 showsbright images and high resolution with a slim outer diameterof 3.4 mm. The working length of 300 mm facilitates diagnosis behindthe vocal cords, or the distance to the patient might beenlarged for hygienical reasons, if required.
Highest optical quality
Range of tip bending 130° up and down
High resolution
2021Flexible ENT Endoscopes, ENF- 210
Rhino-Laryngo Fiberscope ENF-P4
WA91640A Fiberscope “ENF-P4”
Delivery includes:
Endoscope, ETO cap and carrying case
Technical Data
Field of view.........................................................................85°
Direction of view.....................................................................0°
Depth of field ..............................................................5–50 mm
Outer diameter (distal tip)...............................................3.4 mm
Outer diameter...............................................................3.6 mm
Working length..............................................................300 mm
Total length...................................................................530 mm
Maximum angulation (up) ...................................................130°
Maximum angulation (down)...............................................130°
For light-guide adapters, see sheet ACC-170.
Instrument Tray for Flexible Endoscopes
WA05991A Instrument tray,
for flexible endoscopes of CHF, CYF, ENF, HYF, LF,
and URF series,outer dimensions: 531 x 79 x 255 mm
Accessories
A2328 ETO cap “MB-156”
WA23070A Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
W7055190_6-02022
ENF-XPRhino-Laryngo Fiberscope
The ultra-slim 2.2 mm insertion section of this flexible rhino-laryngoscope facilitates minimal invasive access even withdifficult anatomy and is the right choice for pediatricapplication, featuring extraordinary image quality andbrightness.
1.8 mm outer diameter of the distal tip
Superior optical quality
Range of tip bending 130° up and down
Easy access to narrow lumen and paranasal sinuses
2023Flexible ENT Endoscopes, ENF- 215
Rhino-Laryngo Fiberscope ENF-XP
A9163 Fiberscope “ENF-XP”
Delivery includes:
Endoscope, ETO cap, protection tube,
and carrying case
Technical Data
Field of view.........................................................................75°
Direction of view.....................................................................0°
Depth of field ...........................................................2.5–50 mm
Outer diameter (distal tip)...............................................1.8 mm
Outer diameter...............................................................2.2 mm
Working length..............................................................300 mm
Total length...................................................................530 mm
Maximum angulation (up) ...................................................130°
Maximum angulation (down)...............................................130°
For light-guide adapters, see sheet ACC-170.
Instrument Tray for Flexible Endoscopes
WA05991A Instrument tray,
for flexible endoscopes of CHF, CYF, ENF, HYF, LF,
and URF series,outer dimensions: 531 x 79 x 255 mm
Accessories
A2328 ETO cap “MB-156”
WA23070A Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
W7055190_6-02024
ENF-T3Rhino-Laryngo Fiberscope
With its 2.2 mm working channel and an outer diameter of4.8 mm this flexible rhino-laryngoscope is ideally suited fortherapeutical interventions like biopsy, aspiration and removal of foreign bodies. Due to the slim outer diameterapplications can be performed gently under local anesthesia.The working length of 365 mm allows for biopsies even indifficult accessible areas.
Range of tip bending 130° up and down
Excellent optical quality
Ideal therapeutical capability
2025Flexible ENT Endoscopes, ENF- 220
Rhino-Laryngo Fiberscope ENF-T3
WA91610A Fiberscope “ENF-T3”
Delivery includes:
Endoscope, biopsy valve MAJ-210, valve holder MD-51, syringe
valve MB-884, cleaning brushes BW-15B, MH-507, ETO cap,
and carrying case
Technical Data
Field of view.........................................................................85°
Direction of view.....................................................................0°
Depth of field ..............................................................5–50 mm
Outer diameter (distal tip)...............................................4.8 mm
Outer diameter...............................................................5.0 mm
Working channel diameter .............................................2.2 mm
Working length..............................................................365 mm
Total length...................................................................585 mm
Maximum angulation (up) ...................................................130°
Maximum angulation (down)...............................................130°
For light-guide adapters, see sheet ACC-170.
Accessories
A2328 ETO cap “MB-156”
A0453 Cleaning brush “MH-507”,
for the channel opening
026799 Cleaning brush “BW-15B”,
for the instrument
channel
WA23070A Leakage tester,
for manual use,
with indicator,
for all Olympus surgical fiberscopes
Instrument Tray for Flexible Endoscopes
WA05991A Instrument tray,
for flexible endoscopes of CHF, CYF, ENF, HYF, LF,
and URF series,outer dimensions: 531 x 79 x 255 mm
Attachments
A9121 Valve “MD-493”,
for aspiration
A9169 Valve holder “MD-51”,
for biopsy valve MAJ-210,
spare for MD-493
A9122 Biopsy valve “MAJ-210”,
single use,
20 pcs.
A9123 Syringe valve “MB-884”
For Endo-Therapy instruments, see sheet ENF-330.
W7055190_6-02026
�
�
��
Reusable Grasping Forceps
For ENF-VT2
A02902A Grasping forceps “FG-53SX-1”,
1.85 x 700 mm
• For stent and foreign body removal
• Wide jaws with rat teeth to give firm grip
A2819 Grasping forceps “FG-38SX-1”,
1.85 x 700 mm
• For stent and foreign body removal
• Jaws with rat teeth to give firm grip
026238 Grasping forceps “FG-14P-1”,
rat tooth,
1.85 x 1900 mm
• For removal of stents and flat objects
• Rat tooth for firm grip
026266 Grasping forceps “FG-20P-1”,
silicone tip,
1.85 x 1900 mm
• Silicone tip for slippery, flat objects
Injection Needle
For ENF-VT2
• Reusable outer metal sheath used with single use inner
needle
• Ergonomic handle with positive “click” action
• Metal coil sheath enhances mucosal penetration.
• Two-way safety stop for easy handling and to protect
endoscope channel
026540 Cannula “MAJ-75/NM-8L-1”,
0.6 x 1650 mm,
6 pcs.,
026992
sterile, single use
Sheath “MAJ-74”,
for needle MAJ-75 (NM-8L-1),
1 pc., reusable
Reusable Spray Catheter
For ENF-VT2
026027
• To spray dye on suspected areas to confirm the size and
location of lesions.
• Diffuse dye evenly over a wider area.
Cannula “PW-6C-1”,
1050 mm
026028 Valve “MAJ-929”,
for PW-6C-1
ET Instrumentsfor ENF-VT2 and ENF-T3
2027Flexible ENT Endoscopes, ENF- 330
Single Use Biopsy Forceps
For ENF-VT2 and ENF-T3
026659 Biopsy forceps “FB-52C-1”,
fenestrated,
1.8 x 1050 mm
• Ellipsoid cups for deeper biopsies
• Rat tooth to aid anchorage
• Alligator jaws to prevent slippage
• Unique SwingJaw mechanism to aid tangential biopsies
• Fenestrated cups for larger biopsies
A2344 Biopsy forceps “FB-15C-1”,
1.8 x 1050 mm
• For biopsy of tough tissue
• Alligator jaws to prevent slippage
Biopsy forceps,
A2811
026671
fenestrated,
“FB-19C-1”, 1.8 x 1050 mm
“FB-19CR-1”, 1.9 x 1050 mm, rotatable
• For routine biopsies
• Fenestrated cups for larger biopsies
• Minimum tissue damage
• Rotatable version for accurate positioning
A9174 Biopsy forceps “FB-21C-1”,
ellipsoid,
fenestrated,
1.8 x 1050 mm
• Ellipsoid cups for deeper biopsies
• Fenestrated cups for larger biopsies
A9173 Biopsy forceps “FB-34C-1”,
fenestrated,
with needle,
1.8 x 1050 mm
• Needle for improved anchorage
• Fenestrated cups for larger biopsies
• Minimum tissue damage
Single Use Biopsy Forceps
For ENF-VT2
N1081630
• Ribbed coated sheath to aid insertion
• Fenestrated cups for larger biopsies
• Unique swinging jaw mechanism to aid tangential biopsies
• Color coded sheaths for easy recognition
Biopsy forceps “FB-211D”,
alligator jaws,
1.9 x 1150 mm,
sterile, single use,
20 pcs.
N1081830 Biopsy forceps “FB-221D”,
alligator jaws, with needle,
1.9 x 1150 mm,
sterile, single use,
20 pcs.
N1082030 Biopsy forceps “FB-231D”,
1.9 x 1150 mm,
sterile, single use,
20 pcs.
N1082230 Biopsy forceps “FB-241D”,
with needle,
1.9 x 1150 mm,
sterile, single use,
20 pcs.
W7055190_6-02028 �
Hot Biopsy Forceps
Biopsy forceps “FD-7C-1”,
A02909A
024880
6 Fr. x 1050 mm,
monopolar,
A set*
B set
A set includes: Forceps, handle MH-264, HF cable MH-969
B set includes: Forceps
Electrosurgical Snares
• Oval cups
• Uses HF current to coagulate and cut
on request
HF electrode, monopolar,
1.87 mm x 1050 mm,
“SD-7C-1”, A set*, loop 23 mm Ø
A02911A
on request
A02912A
“SD-7C-1”, B set, loop 23 mm Ø
“SD-18C-1”, A set*, loop 13 mm Ø
“SD-18C-1”, B set, loop 13 mm Ø
A set includes: 2 snare tubes, 2 snare wires,
handle MH-264, HF cable MH-969
B set includes: 2 snare tubes, 2 snare wires
• For debulking of tumor
• Braided wire 0.3 mm
• Green safety marking at distal end of catheter
Handle
A02910A SD Handle “MH-264”,
for monopolar instruments
FD-7C-1, SD-7C-1,
Coagulation Electrode
SD-18C-1, KD-31C-1
N1072530 HF electrode “CD-6C-1”,
1.9 mm x 1050 mm,
button, for coagulation,
monopolar, 1 pc.
• For haemostasis after biopsy and coagulation of ulcer lesions
• Fixed distal tip
• Green safety marking at distal end of catheter
HF Cables for ET Instruments
For SD Handle “MH-264” and HF electrode CD-6C-1.
A02915A
For details, see sheet ACC-201.
HF cable “MAJ-860”, monopolar,
for Olympus UES-30/-40,
Erbe International, new generation Valleylab,
Bovie, and Bowa HF units,
A8406
2.09 m length
HF cable “MH-969”, monopolar,
for Olympus UES-10/-20,
and old generation Valleylab HF units,
A02916A
3 m length
HF cable “MAJ-861”, monopolar,
for Erbe T series, Martin,
and Berchtold HF units,2.07 m length
* Not available in Europe
W7055190_6-02030
�
�
�
��