Ziehm 8000Technical Specifications
90° 45°
76 c
m
Highly compactdesign for improved mobility
Perfect imagequality on ahigh-resolutionsplitscreen
C-arm movementsare fully counterbalancedin every position
1k x 1k imaging chain for optimal image quality
Collimator System• Collimator rotation: ± 90°
• Iris collimator: 23 cm I.I.: 50-230 mm diameter
Operating Values• Fluoroscopy:
– kV range: 40 -110 kV– mA range: 0.2-5.5 mA
• Digital radiography (snapshot):– kV range: 40 -110 kV– mA: 8 mA
• Radiography:– kV range: 40 -110 kV– mA: 20 mA min (100-200 V) 20 mA (220-240 V)
Output• Fluoroscopy: up to 605 W
• Digital radiography (snapshot): 880 W
• Type: cesium iodide
• DQE (IEC): 65 %
• Conversion factor: 240 Cd m-2/mR s-1
• Anti-scatter grid: Pb 8/40
• Grayscale: 4,096 shades of gray (12 bit)
23 cm I.I.• Central resolution 23-15-10 cm:
49-56-60 lp/cm
• Contrast ratio: 30:1
ImageIntensifi er
Digital Video Camera• Active pixels: 1,048,576
• Camera matrix: 1,024 x 1,024 pixels
• Bandwidth of video signal: 20 MHz
• Bandwidth of video amplifi er: 50 MHz
• Video (monitor): 1,125 lines
• Signal-to-noise ratio: 68 dB
• Control: ADR / AVR
Digital Video Chain
• Motor-driven vertical travel: 42 cm
• Horizontal travel: 22 cm
• Orbital rotation: -90° / +45°
• Angulation: ± 225°
• Swiveling (panning): ± 10°
• Source-image receptor distance: 95 cm
• C-arm vertical free space: 76 cm(without laser positioning deviceintegrated in generator)
• C-arm depth: 68 cm
• Width: 80 cm
• Length: 162 cm / 184 cm
• Height: 172 cm / 194 cm
• Weight:C-arm mobile stand (23 cm i.i.): 283 kgMonitor cart: 112 kg
Brakes• Steering & braking lever, with parallel
movement of the mobile stand in all directions
• Color-coded brake handles for all movements
Dimensions and
Mechanics
• X-ray tube: stationary anode
• Dual focus: 0.5/1.5 mm (IEC 60336)
• Tube housing heat capacity:– 800 kJ – 1.14 million HU system heat capacity
• Generator type:– high frequency generator– frequency: 40 kHz– microprocessor-controlled
• Nominal output (100 kV): 2,000 W
• Maximum output: 2,200 W
Filtering• Total fi ltering: ≥ 3.9 mm Al equivalent
including 0.1 mm Cu
X-Ray Generator
C-Arm Mobile Stand
Ziehm 8000
Digital Memory• Storage capacity: 10,000 images
(option: 150,000 images)
• Memory matrix: 1,024 x 512 pixels
• Image matrix: 1k x 1k pixels
• Digital image processing: 16 bit
• Video printer: paper and fi lm: Sony® UP 971 / 991
• CD-RW drive (option):– storage capacity: 1,000 images– formats: DICOM, TIFF
• USB port:– storage capacity depends on storage medium– formats: DICOM, TIFF– downsized formats: DICOM, JPG
Networking• Ziehm NetPort (option):
DICOM 3.0 interface (RJ45 or WLAN connection) for digital network integration
• ’Primary Capture‘ mode
• Available DICOM Classes:– Storage Class incl. multiframe capability and Storage Commitment– Print Class– Media Class– Worklist Class incl. Modality Performed Procedure Step (MPPS)– Query Class– Retrieve Class– Verifi cation Class
• WLAN interface for wireless data transfer (option)
Archiving
• High-resolution single fl atscreen monitor with split display:– screen size: 27“ (69 cm)– native resolution: 1,920 x 1,200 pixels– viewing angle (horizontal and vertical): 170°– contrast ratio: 1,000:1– brightness: max. 300 cd/m2
– dimensions: 642 mm x 390 mm x 70 mm
• High-resolution and high-brightnessdual fl atscreen monitors (option):– screen size: 2 x19“ (48 cm)– native resolution: 1,280 x 1,024 pixels– viewing angle (horizontal and vertical): 178°– tilt range: ± 10°– contrast ratio: max. 800:1– brightness: max. 1,000 cd/m2
– dimensions: 45 cm x 68 cm x 9 cm
Monitors
Real-Time Processing Functions• Recursive fi lter: 4 levels (out of 16)
• Stack fi lter (‘Last Image Hold’): 5 levels
• Edge enhancement fi lter: 5 levels
• Windowing and step windowing
• Digital image rotation and reversalwithout radiation
Postprocessing Functions• Edge enhancement: 5 levels
• Zoom: 3 levels
• Image rotation
• Windowing and step windowing
• Grayscale inversion
Data Organization• Patient-based data management
with 16-image mosaic display
Digital ImageProcessing
Monitor Cart
• Power supply: 100-240 VAC (± 10%), 50 /60 Hz
• Current consumption: 14 A continuous (100-120 V)10 A continuous (200-240 V)
• Max. impedance: ≤ 0.3 Ω (100-120 V)≤ 0.6 Ω (200-240 V)
• Class I equipment, Type B
ElectricalRequirements
• Laser positioning device, integrated in image intensifi er and/or generator
• Virtual collimator/copper fi lter
• Measured dose area product meter, with digital display
• Security key switch (x-ray)
• Connection for external radiation warning lamp (incl. software)
• Hand rail around the image intensifi er
Options
• Disposable sterile covers for all sizes
• Additional handrails on the C
• Hand surgery table
• Universal fi lm casette holder
• Emergency stop button on monitor cart
• Additional handrails on the C-arm for orbital rotation support
• Measurement functions
Accessories
Device Classifi cation• MDD 93/42 EEC, Annex IX: IIb
Compliance to QM Requirements• EN ISO 13485 certifi ed
• CAN/CAS ISO 13485 certifi ed
• DIN EN ISO 9001 certifi ed
• MDD 93/42 EEC, Annex II certifi ed
• U.S. 21CFR Part 820
• Ordinance 169 certifi ed
• ISO 14971
Product Compliance• IEC 60601-1 and relevant collateral
and particular standards
Regulatory Compliance
611
1772
1521
642
614
510
225° 225°
10° 10°
1723
-194
3
700
513
455
760
800
45° 90°
921-
1341
329
950
755
678
439
1620-1840
2094-2314
156
Ziehm 8000(C-Arm Mobile Stand)
Ziehm 8000(Monitor Cart)
All dimensions in mm.
Ziehm 8000. This C-arm fi ts ideally into clinical workfl ows. The combination of reliable mobile imaging technology and high-resolution fl atscreen monitors makes it the solution of choice among orthopedic, pain management, traumatology and urology specialists. Every detail of the Ziehm 8000 – from the intuitive positioning of handles and controls through its compact footprint to the ergonomic shape of the mobile standand monitor cart – refl ects our in-depth understanding of clinical environments to support your daily business.
www.ziehm.com
FinlandZiehm Imaging OyKumitehtaankatu 504260 Kerava, FinlandPhone +358.4497575 37 [email protected]
USAZiehm Imaging Inc.6280 Hazeltine National Dr.Orlando, FL 32822, USAPhone +1.(407) 6 15-85 60Fax +1.(407) 6 15-85 61 [email protected]
BrazilZiehm Medical do BrasilAv. Roque Petroni Jr.,1089 cj 90404707-000 São Paulo, BrazilPhone +55.(11) 30 33.5999 Fax +55.(11) 30 33.5997 [email protected]
Headquarters GermanyZiehm Imaging GmbHDonaustrasse 3190451 Nuremberg, GermanyPhone +49.(0) 9 11.21 72-0 Fax +49.(0) 9 11.21 72-390 [email protected]
ItalyZiehm Imaging Srl.Via Paolo Borsellino 22/24 42100 Reggio Emilia, ItalyPhone +39.05 22.61 08 94 Fax +39.05 22.61 24 [email protected]
FranceZiehm Imaging S.A.R.L.1, Allée de Londres91140 Villejust, FrancePhone +33.1 69071665Fax +33.1 [email protected]
ChinaZiehm Medical Shanghai Co., Ltd.Hongqiao New Tower CentreRm 06-07, 25/F83 Loushanguan RoadShanghai, P.R. China; 200336Phone +86.(0) 21.62 369903 Fax +86.(0) 21.62 369916 [email protected]
SingaporeZiehm Imaging Singapore Pte. Ltd.7030 Ang Mo Kio Ave 5#08-53 Northstar@AMKSingapore 569880, SingaporePhone +65.6 39.1 86 00Fax +65.6 39.6 30 09 [email protected]
© 2
016
Zieh
m Im
agin
g, 2
8070
- 0
4/20
16Zi
ehm
Imag
ing
is c
onst
antl
y im
prov
ing
its
prod
ucts
and
res
erve
s th
e ri
ght t
o ch
ange
the
spec
ific
atio
ns a
nd o
ptio
ns w
itho
ut n
otic
e.
Pre
sent
ed d
ata
are
subj
ect t
o to
lera
nces
. Cou
ntry
spe
cifi
c da
ta a
nd o
ptio
ns m
ay a
pply
.