WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer...

18
WL2500 Technical Manual

Transcript of WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer...

Page 1: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

Waterlogic 2500 Technical Manual - Issue B, October 2013

WL2500Technical Manual

Page 2: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

2 3

Waterlogic 2500 Technical Manual - Issue B, October 2013

Index

Machine Overview 4Pre Delivery Inspection Procedures (PDI) 10Installation Procedures 11Operational Instructions 14Maintenance and Servicing 16Sanitizing the Machine 19Cleaning a Waterlogic Machine 20Troubleshooting the WL2500 21Safety and Warranty Information 22Wetted Parts Illustration 24Main Parts Illustration - Freestanding model 26Main PCB Schematic Diagram 29Specifications 32

Page 3: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

4 5

Waterlogic 2500 Technical Manual - Issue B, October 2013

5

Machine Overview

WL 2500 COLD TANKThe cold tank is manufactured from 304 Stainless Steel which is non-corrosive, inert and reflects Ultra Violet Light (UV). The cold water temperature is preset at approximately 5°C by factory, this being ideal temperature for a cold drink. The capacity of the cold tank is 4 litres for freestanding model and 2 litres for mini model. When the water is stored in the Cold Tank it is chilled and exposed to UV at the same time, this protects the water from Bacteria growth. The cold tank temperature is controlled by a thermostat that is set at the factory. The thermostat set point is marked at the back of the machine by a small dot. If the UV light falls, then no cold water will be dispensed.

HOT TANKThe hot water tank has a 1.5 Litres capacity; it is manufactured from 304 stainless steel and is heated by an 800 watts heating element. The temperature of the Hot Tank is controlled by a thermister and it is preset at the factory at approximately 85°C. A BI-metal overload thermostat is fitted to stop the tank over heating and is reset manually. The hot water temperature can be boosted to a maximum of 95°C approximately by using the extra hot button. Setting the hot water temperature at 85°C also helps stop scale forming in the Hot Tank. A special polyphosphate filter can be fitted at the customer’s request. That will help inhibit lime scale formation.

AMbIeNT WATer CIrCuITThis filters the water only. No further cooling, heating or purification is done to the water in this option. The temperature of the water will be the same as the temperature of the water that comes out of the building water supply and the ambient room temperature. The ambient water should be flushed after long periods of non use and after weekends.

The WL 2500 is available in the following options:a) Cold & Hotb) Cold & Ambientc) Cold Only

When reading this manual, note the differences between the options and focus on the particular sections that concern the unit installed.

Waterlogic 2500 Technical Manual - Issue B, October 2013

Page 4: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

6 7

Waterlogic 2500 Technical Manual - Issue B, October 2013

COMpressOrThe compressor operates at 220-240V and at 50Hz. It uses R134a non-Ozone depleting refrigerant gas. The compressor is controlled by an electromechanical thermostat that controls the temperature of the water in the cold tank unit.

WATer pIpe AND FITTINgsThe inlet and the internal water circuit pipe size is 1/4” and 5/16”. The entire internal water circuit and all the components which come in contact with water are food grade NSF approved. The Cold & Ambient water tubing inside the machine should not be exposed to water above 25˚C.

WATer VALVesDispensing of water to the customer is achieved by means of a 24V DC electrical solenoid valve. The valves are energized every time when customer pushes the dispense button for a drink. DC voltage is used to give a positive and quieter action of the solenoid valve. Plastic Panels The moulded panels are made from recyclable ABS plastic. All the ABS plastic panels are UV resistant and meet the standards of CE and UL. Please note that the machine should not be exposed to direct sunlight. Placing machines in direct sunlight from a window, or close to a radiator, or on in a room of high ambient temperature will effect the efficiency of the refrigeration circuit.

FILTersThe filtration systems on the WL2500 designed to reduce dirt and sediment particles from the water. Furthermore, the Activated Carbon process will remove a whole range of contaminants e.g. chlorine and pesticides. There are many kinds of different filter combinations available from Waterlogic to suit local water conditions.

uV LAMpThe UV light is TUV lamp at a wavelength of 253.7 nm, which is very efficient at destroying Bacteria found in water. UV radiation kills Bacteria by destroying the DNA nucleus of Bacteria. An 8 watts UV lamp is fitted for freestanding machine and 4 watts UV lamp for Mini machine. The UV lamp is immersed in the centre of cold tank and protected by a quartz sleeve which allows UV radiation to pass through to the water. A UV sensor alarm is fitted which will alert the customer in the unlikely event of a UV lamp failure. The UV lamp should be changed for every six months.When the lamp is changed the quartz sleeve should be removed and cleaned also.

pCbThe PCB (Printed Circuit Board) is the control unit for the WL2500; it is responsible for the selection and dispensing of water, and extra hot water boost. The PCB drives an LED which informs the user of the status of the unit. The PCB has a power on indicator and also indicates to the user what option of water is currently selected by changing colour. Cold water will always be as a default option; hot water, extra hot water must be selected and then dispense.

Page 5: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

8 9

Waterlogic 2500 Technical Manual - Issue B, October 2013

Main parts Layout Hot and Cold

9

Waterlogic 2500 Technical Manual - Issue B, October 2013

FILTER

IN (Water)

SOLENOIDVALVE

SOLENOIDVALVE

HOT WATER OUT

COLD WATER OUT

AIR VENT

FILTERDRYER

COLDSENSOR

COLDTANK

HOTTANK

COMPRESSOR

CONDENSER

Page 6: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

10 11

Waterlogic 2500 Technical Manual - Issue B, October 2013

Installation procedures

Important notice: This procedure should only be carried out by an engineer or staff trained by Waterlogic International or an approved distributing agent.

1. Site the machine as close to the electrical and mains drinking water supply as possible with a 50mm air gap at both sides and back of the machine. Mount the machine on a firm flat surface so that it cannot topple over. Please remember that the machine should not be exposed to direct sunlight or heat sources above 32°C.

2. It is advisable that the water supply and electrical supply be within 2 meters of the machine for ease of installation.

3. Level the machine using the adjustable feet.

4. Remove the top cover of the machine. If you are installing a freestanding machine also remove the lower front cover. This is retained by two screws located under the front edge at the bottom of the cover and two clips in the same location. Remove the screws and push clips up to release. To gain access to the screws tilt the ma-chine backward at an angle of 10 degrees.

5. Make the water connection using an installation kit. Waterlogic recommends the use of a pressure reducing valve, and shut off valve and a non return valve. These should be fitted before the water intake to the machine. Minimum operating pres-sure for the machine to work suitably is 1.5 bar. The ideal operating pressure is of 3 bar. At pressures higher than 3 bar the machine will not function correctly and can lead to leaks.

6. Please flush the water supply pipe until it runs clear, before making the water connection to rear of the machine.

7. The power lead is located in a recess on the top packing cover of the machine re-gardless whether it is a mini or a free standing model. Inspect the electrical socket, the machine plug and the power cable for any transit damage. Now plug the power lead into the back of the machine. As soon as you plug the machine into a suitable power supply voltage will be available to the PCB and solenoid valves and you can now start to flush water through the machine. Do not at this point turn on the heater and compressor switch at the rear of the machine. This switch should only be turned on once the hot tank is filled with water.

pre Delivery Inspection procedures (pDI)

1. Unpack and carry out a visual inspection of the unit for any transit damage.

2. Remove the top cover and the lower front panel and visually inspect the internals of the machine for any wires or pipes that may have come loose in transit.

3. Connect the water supply.

4. Ensure the switch on the rear of the machine is in off position and connect the unit to a power supply.

5. The unit is now live and suitable safety precautions should be taken.

6. Flush water through the hot tank first until the water runs clear of any carbon fines. Approximately 10 litres.

7. Now flush water through the Cold Tank. Approximately 10 litres. (20 litres if cold only)

8. Once you are sure that water is running through both the cooling and heating circuit then turn on the heater and compressor switch at the rear of the machine.

9. Carry out a visual inspection for any water leaks.

10. The hot water will heat to approximately 85°C. The extra hot water will heat up approximately 95°C if selected.

11. To test the cold water wait until the compressor has shut off. Test the 2nd cup of water taken. It should be between 5 and 8°C.

12. Inspect the cold water produced for clarity and taste. If required flush more water to remove any adverse taste or carbon fines.

13. Return the switch to the off position and isolate the power and water to the machine.

14. Drain the hot tank and cold tank.

15. Replace all panels, clean the machine and repack the machine.

Page 7: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

12 13

Waterlogic 2500 Technical Manual - Issue B, October 2013

8. The hot water temperatures is set at 85°C and the cold water temperatures is set at 5°C at the factory. It is not possible to adjust the hot water temperature, but the cold water temperature can be adjusted by regulating the thermostat situated at the back of themachine. This thermostat is set at a specific point at the factory. This point is marked out by a small dot situated on the outside of the thermostat. It is advised that you do not adjust the cold thermostat past the factory set point of 5°C as this may result in the system freezing.

9. If installing a hot and cold model, do the following. Alternatively go to point 10.Select the hot water option and press the dispense button to start flushing water through the machine filter and hot tank. The filter will produce carbon fines at first and the water may have a black appearance. Continue to flush 10 litres of water.

10. Select the cold water option and press the dispense button and flush for 10 litres of water through the cold tank. If you are installing a cold only machine then flush for 20 litres. This will generate the filter and clean any residual water from the machine.

11. Check the machine for any water leaks and ensure that all water fittings are se-cured properly.

12. Once you are satisfied that water is passing through both the hot and cold tanksuccessfully then turn on the heater/compressor switch at the back of the machine. The machine will now start to heat and chill.

13. The hot water will heat to 85°C approximately. The extra hot water will heat up to 95°C approximately if the extra hot button is selected.

14. The cold tank will start cooling. When the machine has reached the target tem-perature the compressor will stop running. The temperature will continue to drop as any ice that has formed on the sides of the tanks will start to melt and equalize the tank temperature.

15. To test the water temperatures then please ensure that you use an accurate previously calibrated thermometer.

16. Please ensure that the cold water produced has a good taste. If you detect a plastic taste then it is an indication that the machine needs to be flushed again.

17. Check the machine to make sure it is electrically safe.

INsTALLATION KIT• The machine must be installed according to the local guidelines.

• Waterlogic strongly recommend that a pressure reducing valve set at 3 bar and a nonreturn valve be used on all machine installations.

• The WL2500 should not be connected to water supplies of unknown bacterial quality or those are not already fit for human consumption. The machine should only be connected to a Potable drinking water supply.

• The filter and UV lamp on the WL2500 must be changed every 6 months.

• The cold tank should also be flushed and sanitized every 6 months.

• Waterlogic International strongly recommends the use of an anti-flood device.

The part number for the installation kit shown below is “P-KIT INSTALLATION”.

Fig 1. Waterlogic Installation Kit

1 - 15mm Compression Inlet2 - Double Check Valve (great for carbonated water)3 - Adjustable Pressure Reducing Valve4 - Integral Isolator5 - Pressure Gauge Port6 - Waterblock7 - 1/4” Pushfit Outlet

Page 8: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

14 15

Waterlogic 2500 Technical Manual - Issue B, October 2013

Hot & Cold

The option buttons are very simple to identify. The following table indicates the hot and cold option, or cold and ambient option on the machine.

Operating Instructions

Operating the machine is very simple. It’s as simple as selecting the option you want, and press the main dispense button. The machine will dispense fresh water at your disposal.the main dispense button. The machine will dispense fresh water at your disposal.

Note: Default mode is cold water. If you have a cold only machine you will only haveavailable the main button.

COLD WATerPush Main button, LED shows green, it dispenses cold water.

HOT OPTION AMBIENT OPTIONCOLD OPTIONEXTRA HOT OPTION

button 1: select hot water

button 2: select extra hot water

button 3: select ambient water

Main button: to dispense water from selection

AMbIeNT WATerPush Ambient button LED shows red, Push main button it dispenses ambient water.

HOT WATerPush hot water button LED shows red, Push Main button, it dispenses hot water

eXTrA HOT WATerPush extra hot water button LED shows orange; hot water tank starts heating, then push main button, it dispenses extra hot water at approximately 95°C.

Page 9: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

16 17

Waterlogic 2500 Technical Manual - Issue B, October 2013

Maintenance and servicing

6 MONTH serVICe prOCeDure

Free sTANDINg MODeLs• The following instructions are for all machines (Hot & Cold; Cold & Ambient and Cold Only).• Every six months the filters and UV lamp should be changed.• A machine with the hot water option may require removing any Calcium build-up inside the hot tank, depending on local water conditions.• Only trained personnel should repair and service the Waterlogic 2500.

1) Isolate the power to the machine, by turning off the switch from the back of the machine and removing the plug from the socket.

2) To access the filters, undo the screws and release the clips located in front of the lower front panel and remove panel to gain access to interior of machine. To access the filters on a mini machine then remove the top cover. This is a high voltage area and the machine should be isolated from the power supply.

3) There is no need to turn off the water supply; the water is automatically isolated when you remove the filter.

4) To remove the Waterlogic filters, twist anti-clockwise and replace with a new Waterlogic twist filter, twist clockwise.

5) Remove the Waterlogic UV lamp by unplugging the UV loom connector and pulling the lamp upwards.

6) Unscrew the UV retaining nut and remove the Quartz Sleeve from the cold tank. Clean the Quartz Sleeve and remove any surface lime scale that may have adhered to the sleeve surface. Check the black O Ring for signs of perishing and replace if necessary.

7) Fit the Quartz Sleeve back into the cold tank taking great care at this stage not to crack the Quartz Sleeve by over tightening the UV retaining nut.

8) Replace the UV lamp assembly and re-connect it. Do not touch the UV lamp with bare hands.

9) Remove, check and inspect the blue faucet nipple and if it is cracked or has Calcium build up, replace it. Please ensure that you use cleaning gloves when handling parts that come in direct contact with the drinking water.

10) Inspect the electrical and water connections of the machine.

11) Check the air gap around the machine to ensure it is not blocked.

12) Turn on red switch, on the back of the machine.

13) Check that the UV lamp is alight by observing a blue glow from the top of the UV cap. Do not remove the lamp from holder whilst ignited and do not look into a ignited UV light.

14) Close the front of the machine and the top of the machine by fitting the panels back to their original position.

15) Flush ten litres of hot water and five litres of cold water through the machine to ensure that the filters are generated and the water is running clear of any carbon fines.

16) Turn on the heater and compressor switch and allow the machine to cool and heat the water.

17) Taste the water and check the machine is clean and functions to the customer’s satisfaction. If you are not satisfied with the quality of the water, flush two more litres of water through the machine.

MINI MODeLs• The following instructions are for all WL2500 mini machines (Hot & Cold)• Every six months the filters and UV lamp should be changed.• A machine with the hot water option may require removing any Calcium build-up, depending on local water conditions.

1. Isolate the power to the machine, by turning off the switch from the back of the machine and removing the plug from the socket.

2. To access the filters, undo the screws located at the back of the top cover and remove the top cover.

3. There is no need to turn off the water supply; the water is automatically isolated when you remove the filter.

4. To remove the Waterlogic filters, twist anti-clockwise and replace with a new Waterlogic twist filter, twist clockwise.

Page 10: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

18 19

Waterlogic 2500 Technical Manual - Issue B, October 2013

5. Remove the Waterlogic UV lamp by unplugging the UV loom connector and pulling the lamp upwards.

6. Unscrew the UV retaining nut and remove the Quartz Sleeve from the cold tank. Clean the Quartz Sleeve and remove any surface lime scale that may have adhered to the sleeve surface. Check the black O Ring for signs of perishing and replaced if necessary.

7. Fit the Quartz Sleeve back into the cold tank taking great care at this stage not to crack the Quartz Sleeve by over tightening the UV retaining nut.

8. Replace the UV lamp assembly and re-connect it. Do not touch the UV lamp with bare hands.

9. Remove, check and inspect the blue faucet nipple and if it is cracked or has Calcium build up, replace it. Please ensure that you use cleaning gloves when handling parts that come in direct contact with the drinking water.

10. De-scale the hot tank.

11. Inspect the electrical and water connections of the machine.

12. Replace the top cover

13. Turn on the red switch, on the back of the machine.

14. Check that the UV lamp is alight by observing a blue glow from the top of the UV cap. Do not remove the lamp from holder whilst ignited and do not look into ignited UV light.

15. Check the air gap around the machine to ensure it is not blocked.

16. Reconnect the power to the machine and flush 10 litres of water through the hot tank and 5 litres through the cold tank.

17. Turn on the heater compressor switch, on the back of the machine and allow the water to heat and cool.

18. Taste the water and check the machine is clean and functions to the customer’s satisfaction. If you are not satisfied with the quality of the water, flush more water through the machine.

Notes:Allow 45 minutes for the full servicing of the unit.Waterlogic recommend the use of sterilizing solution, vending machine surface cleaner, and Bacterial Wipes. Please do not use any abrasive or cream surface cleaners.

sANITIzINg THe MACHINe1) You will need to have an Ametek filter housing to follow this procedure. Also sanitizer, disposable rubber gloves, and bacterial wipes or spray.

2) Mix a solution of sanitizer in the Ametek filter housing.

3) Turn off the water supply to the machine and release the internal water pressure by depressing the dispense button momentarily and remove the water supply pipe.

4) Isolate the power to the machine.

5) Bypass the internal twist filter to avoid mixing sanitizing solution with the active carbon.

6) Connect the outlet of the Ametek housing to the inlet of the machine and connect supply water pipe to the inlet of the Ametek housing.

7) Turn on the power and water supply to the machine.

8) Depress the dispense button until the sanitation fluid starts to flow out of the faucet nipple.

9) Allow the sanitation fluid to stand in the machine for 20 minutes.

10) Do not let any sanitation fluid enter the hot tank.

11) Then flush the cold water until the water runs clear of sanitizer.

12) Again isolate the water to the machine and release any internal water pressure now isolate the power.

13) If this procedure is being done in conjunction with the 6 monthly services then change the filter.

14) Remove the Ametek filter housing from the back of the machine and re-connect the water supply pipe to the back of the machine. Reconnect the filter.

15) Turn on the power and water flush the machine until the water runs clear.

16) Visually inspect water connections for any leaks.

17) Remove the faucet nipple and inspect to see if there are any cracks or scratches or limescale build up on the nipple, if so then replace it. If the faucet nipple is OK then sterilise it and put back using clean rubber gloves.

18) Remove and clean the drip tray, and grill. If the grill is damaged or heavily stained and you are unable to clean it then it is advisable to replace the grill.

19) Wipe all surfaces around the drip tray and faucet nipple area with a bacterial wipe or spray.20) Return the drip tray to position.

Page 11: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

20 21

Waterlogic 2500 Technical Manual - Issue B, October 2013

21) Flush a further 15 litres of water if you have changed the filter and ensure there are no carbon fines and all sanitation fluid has been removed from the water system.22) All personnel should be aware of the company requirements for their own personal health and hygiene.23) Test for taste before leaving and ensure that the water quality of the machine isadequate.

CLeANINg A WATerLOgIC MACHINe• It is recommended to clean the machine at least once per week. The cleaning cycle may be required more often depending on the amount of use of the machine and the surrounding environment.

• Turn off the power at the wall socket and remove the power cord at the rear of themachine.

• Please wear clean rubber gloves to carry out the cleaning functions.

• Remove the top cover and replace the blue faucet nipple. Clean and soak the removed nipple in sterilizing solution ready for the next cleaning cycle. Discard any faucet nipples that are cracked, or split. Be careful not to drip water on the PCB.

• Remove and clean the drip tray assembly.

• Clean all machine surfaces with non-abrasive vending machine cleaner/sanitizer.

• Replace the drip tray.

• Wipe the faucet nipple and all plastic surfaces with an anti Bacterial Wipe.

• Re-connect the machine and turn on the power and check for correct operation.

pArTs requIreD TO CLeAN A MACHINe• Rubber Gloves• Paper Towel• Surface Cleaner• Blue Faucet Nipple• Bacterial Wipes• A Replacement drip tray/grill if required• Allow 15 minutes

TrOubLesHOOTINg THe WL2500 The following is a list of different problems that may be found while installing and operating the WL 2500.

1. No flow of water: In this case, make sure that there is a water supply to the machine and is turned on. Please ensure that the anti flood device is reset. Ensure that the filter is twisted in all the way home into the head; otherwise the valve inside the filter head will not be opened. Check to see that the filter is not blocked with sediment.2. There is flow for the hot water, but no flow for the cold water: This may be a result of the water inside the cold tank mechanism being frozen. Ensure that the thermostat is set at the factory setting. Disconnect the power mains from the back of the machine and allow the ice inside the cold tank to melt.3. Water dispensed by the machine is neither hot nor cold: Make sure that theheater/compressor switch at the back of the machine is on.4. The power indicator is not on: Make sure that the machine is plugged in correctly and that the switch is on. If the machine is properly set up, then remove the top cover of the machine and check the fuse on the back of the machine.5. bad taste: Flush the machine for a period of 15 minutes. If the bad taste persists taste the water coming directly from the filter, if still bad change the filter, or contact your authorised service provider.6. Low flow of cold water: If this happens in the cold water circuit, there may be a problem with freezing. Please refer to point number 2 and follow the instructions7. Low flow of water for all circuits of the machine: Ensure that the filter is not blocked. The filter may require changing, or there is low water supply pressure.8. Low flow of hot water. Indicates that the hot tank needs to be de-scaled.9. Hot water is cold: If all the electrical connections are fitted properly, there is a chance that the overload mechanism has been triggered. In this case, isolate the power supply to the machine, remove the upper and lower front panels to gain access to the hot water tank. On the side of the hot tank there is a manual reset button for the overload mechanism. Press the button and reassemble all the panels. Reconnect all the power supplies and make sure that the machine continues to heat up the water as normal.

10. Cold water is warm. Make sure that you are not testing the ambient option. Check the thermostat is at the set point. Make sure the machine is not in direct sunlight or a room with a high ambient temperature (32ºC +). Ensure the heater/compressor switch is on. If none of the prior then assume standard refrigeration fault finding procedures.

11. uV failure. Make sure the lamp is connected to the PCB board, check if the lamp is functioning, checking the ballast. Change the UV lamp.

Note. Fault finding of Waterlogic 2500 must only be carried out by trained personnel.

Page 12: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

22 23

Waterlogic 2500 Technical Manual - Issue B, October 2013

CAuTIONSubject to the standard terms and conditions of sale (a copy of which has been provided to you), neither Waterlogic International Limited (“Waterlogic”), nor any affiliated companies shall be liable for any damage which could affect, directly or indirectly, any person or property. Please be aware that any warranties accompanying the sale of our products will be invalidated by any of the following:

• Incorrect installation• Incorrect use of the WL2500• Unsuitable electrical and water supply• Major short-coming of maintenance• Technical interventions or alterations of an unauthorized nature• Adoption and use of unapproved spare parts• Engagement of untrained personnel

Waterlogic has a policy of constant and continual improvement and thereforereserves the right to change specifications without prior notice, other than in thecase of significant changes.

safety and Warranty Information

Page 13: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

24 25

Waterlogic 2500 Technical Manual - Issue B, October 2013

Wetted parts IllustrationWetted Parts List

N° Part Description

1 JG Bulkhead Connector Union 1/4" * 1/4"2 JG LLD PE Tube - Blue O.D.1/4"3 Valved Twist Filter Head4 Carbon GAC Filter5 JG LLD PE Tube - Blue O.D.1/4"6 JG Equal Tee Connector 1/4"7 Solenoid Valve DC24V 1000mm8 JG Reducing Elbow Connector 5/16" * 1/4"9 JG LLDPE Tube - Blue 8mm10 UV Cold Tank Ass'y 4L with UV Holder11 JG LLDPE Tube - Blue 8mm

12

Faucet HC & CAFacuet Nipple BlueStainless Steel Insert for FaucetNatural Faucet O-Ring (Silicon White)Stainless Steel Gauze for Faucet

13 Silicon Tube 5/16"14 JG LLD PE Tube - Blue O.D.1/4"15 JG Equal Tee Connector 1/4"16 Silicon Tube 5/16"17 Solenoid Valve DC24V 1000mm18 JG Reducing Elbow Connector 5/16" * 1/4"19 JG LLDPE Tube - Blue 8mm20 Drawn Hot Tank Ass'y 1.5L 220V/50Hz 800w21 Silicon Tube 5/16"22 Silicon Tube 5/16"

13

5

2

4

199

8

20

6 7

10

12

11

22

1415

14

13 16

1817

21

Page 14: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

26 27

Waterlogic 2500 Technical Manual - Issue B, October 2013

Main parts IllustrationFree Standing Model

spare parts Numbers

1

2345

8

11

12

13

14

15

16

22 23

24

25

273549

47

46

45

4344 38

48

41423940

2827

29 30

3132

33

34

26

17 18 19 20

21

910

6

7

3736

N° Part Description

1 WL2000 Top Cover Black2 Thermostat3 WL2000 FS Silver Back Panel4 Switch - Power (Red)5 Fuse Holder & Fuse6 Socket for Plug Connection7 Gasket for Power Socket8 FS Silver Side Panel9 Plastic Cap for 1/4" Bulkhead Fitting10 JG Bulkhead Connector Union 1/4" * 1/4"11 Compressor (R134a 1/8HP) 230V/50Hz thermally protected12 Down Base13 Unit Control Rubber Feet14 Bolt M6*3015 Filter Bracket16 JG Reducing Elbow Connector 5/16" * 1/4"17 Solenoid Valve DC24V 1000mm18 JG Equal Tee Connector 1/4"19 Solenoid Valve DC24V 1000mm20 JG Reducing Elbow Connector 5/16" * 1/4"21 Cushion for Solenoid Valve22 Filter Clip 3"23 Valved Twist Filter Head24 Carbon GAC Filter25 Front Down Panel

Page 15: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

28 29

Waterlogic 2500 Technical Manual - Issue B, October 2013

N° Part Description

26 Front Down Insert Panel with paint

27

Faucet HC & CAFacuet Nipple BlueStainless Steel Insert for Faucet WL850Natural Faucet O-Ring (Silicon White)Stainless Steel Gauze for Faucet

28 Front Panel for Drip Tray Insert29 WL2500 Display PCB HC30 Silicon Button Key Mat HC31 WL2000 Front Hatch Panel Charcoal32 Button Label HC & CA33 Drip Tray Grill34 Drip Tray Body Charcoal35 FS Silver Side Panel36 UV Lamp Fixing Rubber (Silicon)37 UV Lamp Retaining Threaded Nut38 UV Lamp 8W Philips39 O-ring (Black Quartz Sleeve)40 Quartz Sleeve D310mm for 8W Lamp41 Main PCB Fixing Bracket (FS)

42Main PCB HCPlastic PCB Support

43 Power Transformer UV 220V/50Hz44 Chinese Ballast Metal Cover 220V/50Hz45 Upper Base46 Hot Tank Fixing Bracket47 Drawn Hot Tank Ass'y 1.5L 220V/50Hz (Sensor) 800w48 UV Cold Tank Assembly 4L with UV Holder49 Wire Condenser

Main pCb schematic DiagramHot and Cold

Page 16: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

30 31

Waterlogic 2500 Technical Manual - Issue B, October 2013

Main pCb schematic DiagramCold only

Main pCb schematic DiagramCold and Ambient

Page 17: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

32 33

Waterlogic 2500 Technical Manual - Issue B, October 2013

Technical specifications

Description WLHCW2500 WLCW2500 WLMHCW2500 WLMCW2500

Width Depth Height 345W*367D*1030H 345W * 367D * 480H

Water Connection 1/4" Hose 1/4” Hose 1/4” Hose 1/4” Hose

Cold Water Temp 5 - 8°C 5 - 8°C 5 - 8°C 5 - 8°C

Hot Water Temp 85 - 95°C 85 - 95°C 85 - 95°C 85 - 95°C

Weight 29kg 27kg 27kg 25kg

Power Supply 230Volt / 50Hz 230Volt / 50Hz 230Volt / 50Hz 230Volt / 50Hz

Control & Unit 4.2 Amp 4.2 Amp 4.2 Amp 4.2 Amp

Heater 800W N/A 800W N/A

Refrigeration Gas 65g 65g 65g 65g

Page 18: WL2500 Technical Manual - Waterlogic · A UV sensor alarm is fitted which will alert the customer in the unlikely ... pCb The PCB (Printed Circuit Board) ... The PCB has a power on

34

EN

G03

94-

20/1

1/13

WLI Trading Ltd.Suite 4, 2nd Floor Beacon Court, Sandyford, Dublin 18, Ireland

www.waterlogic.com

Waterlogic usA, 11710 Stonegate Circle, Omaha, NE 68164

Speak to a Water Expert rest of the world

[email protected] + 353 1 293 1960

usA, Canada and Mexico

[email protected] + 1 402 884 7212