Wide I/P Voltage and O/P Voltage Regulation

Wide input voltage range*: -40~20%, reduces the chance of using the battery.

Voltage regulation:Output voltage regulation < ± 1 %, provides stable power supply.

7

This design allows the UPS to operate in harsh electrical environments and provide a stable power supply.

* Note: Full load: -25%~+20%

• Over Voltage• Transient

• Output Voltage (±1% regulation)

Availability

Delta Confidential

DSP Intelligent Control

8

Simplification of the control circuit to enhance the flexibility and stability

Reduction in the number of electronic components to lower failure rate

Increased reliability achieved by fail-safe detection of DSP allowing to automatically transfer to static bypass when DSP failed.

* Note: Digital Signal Processor

Faster computation capability to enhance system stability and provide precise voltage to load

Availability

Delta Confidential

Inbuilt Manual Bypass

9

The design ensures system availability during service maintenance.

AC/DC

BYPASS INPUT

MAIN INPUT

OUTPUTDC/AC

UPS

MaintenanceManually switch to bypass source to avoid downtime during service maintenance.

Availability

Delta Confidential

Dual Input Design andRedundant Aux. Power

10

Dual input design to allow input from 2 different sources of power supply for higher availability

Redundant auxiliary power to deliver high system reliability

Single Aux. Power failure won’t affect the output load.

Availability

Delta Confidential

User Benefits

1111

PowerPerformance& Efficiency

Availability

Flexibility Manageability

Delta Confidential

Excellent Operating Efficiency

12

One of the most energy-efficient UPS in its class AC-AC efficiency up to 96% ECO mode efficiency up to 99% The significant savings in operational costs

PowerPerformance& Efficiency

100,000 €

110,000 €

120,000 €

130,000 €

140,000 €

150,000 €

160,000 €

170,000 €

180,000 €

Altron HPH Legacy UPS

Power consumption comparison

UltronHPH

Legacy UPS

Power provided during day 30 30,00 kWAdditional losses as efficiency difference 0% 4%Total consumption increased by losses 30 31,25 kWDay consumption, considered 14 hours 420 437 kWh

Power provided During night ....50% 15 15 kWAdditional losses by efficiency diff.erence 0% 6%Total consumption increased by losses 15 15,96 kWNight consumption considered 10 hours 150 159,57 kWh

Total (day + night) consumption 570 597 kWYearly consumption - per 360 Days 205.200 214.947 kWLifetime consumption per 8 years 1.641.600 1.719.574 kWhLifetime Bill for Power 0,1EUR/kWh 164.160 171.957 EURPower saving per 8 years operation 77.974 kWhMoney saving per 8 years operation 7.797 EUR

Delta Confidential13

PF = 1 PF = 0.9 PF = 0.8

40KW 36KW 32KW

40kVA 40kVA 40kVA

11% less25% less

Noderating

No derating with any loads (leading or lagging). Permanent 100% kW. No over-sized UPS for any loads. More output power than legacy UPS. High inverter reliability to support full power to any loads.

UPS A UPS BDelta Ultron HPH

Output Power Factor = 1 kVA=KW Power

Performance& Efficiency

Delta Confidential14

Lower Harmonic Distortion

THDv

Optimal generator size can be chosen

Initial investment cost and installation cost can be reduced

THDi

THDi <3%

Better power quality Less heat to prevent low performance

and short life of load

THDv <2%

Optimize generator sizing & mains

transformer

Low pollution (iTHD < 3%) to upstream power

Lower THDvfor better power quality

PowerPerformance& Efficiency

Delta Confidential15

Smaller Footprint for longerbackup application

Smaller footprint than competitor’s products Better space utilization and saved space for revenue-

producing equipment

Dimensions (mm) Footprint(mm2)H W D

Delta UltronHPH 800 380 800 304,000

Competitor A 1400 600 825 495,000

Competitor B 1490 523 838 438,300

Competitor C 823 523 854 446,600

30/40kW configuration

PowerPerformance& Efficiency

Delta Confidential16

Intelligent Fan Speed Controland Failure Detection

3 stages of fan speed control to maximize efficiency and significantly reduce audible noise

Automatically adjusts the fan speed based on the change of load percentage

Fan failure detection and easy replacement design to simplify the maintenance process and reduce MTTR

Load 0% 40% 70% 100%

Slow Fast Fan Speed

PowerPerformance& Efficiency

Delta Confidential

User Benefits

1717

Flexibility

AvailabilityPower

Performance& Efficiency

Manageability

Delta Confidential

Parallel Expansion

18

Parallel expansion without extra hardware allows quick capacityupgrades to meet business growth.

Add more UPSs when more facilities are expanded.

Parallel Expansion Up to 4 units

Maximum Capacity = 160KW

Loads Loads Loads

Flexibility

Delta Confidential19

A Wide Choice of Configurations

Stand Alone

N+X redundancy

Load

Up to 4 units in a parallel configuration to provide redundancy for reliability

Load

Hot Stand-By

Load

Normal mains

By pass mains

Flexibility

Delta Confidential

User Benefits

2020

Manageability

AvailabilityPower

Performance& Efficiency

Flexibility

Delta Confidential

• Flexible length of string enable optimal battery selection• Battery remaining capacity displayed in percentage• Over charge protection• Deep discharge protection• Float/boost stage charge• Auto/manual battery test• Battery remaining capacity warning• Battery reverse detection• Compatibility with the SMF/VRLA/Ni-Cd/LATB batteries

Intelligent Battery Management

21

Prevents battery from overcharge and deep discharge situations to sustain battery lifespan.

Manageability

Delta Confidential22

Intelligent Battery Management

Adjustable charging currentEven at full load conditions, Ultron HPH offers up to 9A charging current for 40kW model and 5A for 20/30kW model. Optionaly 9A.

Flexible battery voltage Adjustable battery voltage range 456V~504V and charging voltage from 254V to 291V adapt to different types of batteries

Flexible arrangement of battery quantityChangeable battery quantity from 36 to 42 pcsto optimize battery investment

9A Max. charging capability: 9A

5A1

2

3

Manageability

Delta Confidential

50%SpaceSaving

Batterycabinet #1

23

Common Battery Configuration

Customers can save installation space and reduce battery cost via common battery configuration in parallel mode.

Save 50% Space!!

Manageability

Batterycabinet #2

Delta Confidential24

Mini Slot Provides the cost-effective

alternative for multiple mini-size cards such as Mini SNMP, Mini Relay I/O, Mini USB, Mini ModBus or Mini TVSS cards.

SNMP IPv4, IPv6 Card Monitors and controls the status of

the UPS via a network system. The SNMP IPv6 version adds the

security protocols to response requirements, and it is the next generation of internet protocol standard.

ModBus CardProvides continuous and reliable remote monitoring of a UPS system through Industrial Automation System (IAS) and Building Management System.

Relay I/O CardIncreases the quantity of dry contacts.

Smart Slot Accepts multiple communications cards

1 2

1

2

Connectivity & Manageability

Ultron HPH 20 kW Rear View

Manageability

Delta Confidential25

RS232 PortConnects the UPS to a computer

Parallel PortsFor UPS parallelcommunication

REPOFor remote emergency shutdown

Charger Detection PortTo connect with an external charger box

Output / Input Dry Contacts Provides 6 sets of programmable output

dry contacts for receiving UPS events Provides 2 sets of input dry contacts

1 3

4

5 6

Connectivity & Manageability

2

Parallel SwitchActivates UPS parallel function

Ultron HPH 20 kW Rear View

Manageability

Delta Confidential26

• Insight Power ManagerCentralized monitoring system over networks.

• UPSentry 2012Communicates with UPS through RS232 and USB for UPS managementWorks with ShutdownAgent to protect a group of PCs, workstations or servers

• Webserver on SNMP card IPv4• Advanced web server monitoring on SNMPcard IPv

• ShutdownAgent 2012Cooperates with SNMP card or UPSentry 2012 to shutdown multi-servers in various operating systems and virtual machine gracefully to prevent possible data corruption

Management Software

NetworkSerial

UPSentry 2012

ShutdownAgent2012

HUB

ShutdownAgent2012

ShutdownAgent2012

InsightPowerSNMP card

Manageability

Delta Confidential27

Control and Display Panel

Excellent local communications through LCD panel

Power On /Off Keys

Online/Battery/Bypass Mode / Fault LED Indicator

Function keys

EPO Key

This LCD panel displays the operating status of the UPS and the relevant monitoring data.

Manageability

Delta Confidential

Why Ultron HPH Series?

AvailabilityAvailability

• Wide input voltage tolerance

• DSP design• High overload

protection• Dual input

• Redundant Aux. power

• In-built manual bypass

FlexibilityFlexibility

• A wide choice of configurations:N+X redundancy, stand alone, hot stand-by,and more.

• Parallel expansion up to 4 units

• O/P PF = 1• THDi<3% ; THDv<2%• AC-AC efficiency

up to 96%

• ECO mode efficiency up to 99%

• Small footprint

Power Performance &

Efficiency

Power Performance &

Efficiency

28

Best-in-class performance

and power protection for

mission critical applications

ManageabilityManageability

• Multi-connectivity interface

• Advanced UPS management & software

• Intelligent battery management

• Common battery configuration

To learn more about Delta MCIS, please visitwww.deltapowersolutions.com

Mission Critical Infrastructure Solutions(MCIS)

The power behind competitiveness