Urgent - Pennsylvania State University · 2015-10-15 · – According to Energy Matters, a...
Transcript of Urgent - Pennsylvania State University · 2015-10-15 · – According to Energy Matters, a...
10/4/2015 1 KCF Technologies, Inc. -- Copyright 2014
Urgent Vibration Applications in Oil & Gas
and Industrial Manufacturing
Jeremy Frank, PhD President, KCF Technologies, Inc.
April 27, 2015
Impact of Poor Maintenance Practices
• $750 Billion/year wasted (poor repair and maintenance) – According to Energy Matters, a magazine published by the DoE
• $2,400 Billion/year wasted (collateral damage) - According to DoE’s Advanced Manufacturing Office
10/4/2015 KCF Technologies, Inc. Proprietary & Confidential -- Copyright 2014 2
Vibration Expertise is in Need
10/4/2015 KCF Technologies, Inc. Proprietary & Confidential -- Copyright 2014 3
Easy (but lower value) 10 sensors 1 minute setup 1 hrs/month
Challenging (but higher value) 100 sensors 50 minute setup >100 hrs/month
Most Maintenance Programs are Flawed
10/30/2013 KCF Technologies, Inc. Proprietary & Confidential -- Copyright 2013 4
(Source: Wheeler, “Align Facilities Engineering Objectives with Business Goals to Improve Results and Eliminate Wasted Time and Money,” 2007)
• Fallacy of Preventive Maintenance
Example: Paper/Pulp Liquor Pumps
• Problem: Premature motor/pump failure
• Solution: Detect Root Cause (Process Change)
Alarm Shut-Down
Paper Coating: Re-Reeler
Rereeler Data – Actionable Information
7
Benefits of Information
1. Quantify suspect condition (noise/vibration)
2. Localize and diagnose areas of concern (gearbox axial)
3. Enable and confirm redesign (collaborate)
4. Optimize preventive maintenance
#7 Paper Machine – Center Roll Gearbox
8
Gear Mesh Sideband (load, backlash, wear)
Oil & Gas – Pressure Pumping Site
10/4/2015 9 KCF Technologies, Inc. -- Copyright 2014
Damage/Vibration Comparison Between Fleets
KCF Technologies, Inc. Proprietary & Confidential -- Copyright 2014 10/4/2015 10
Fluid End – Failure @ 50 hours
10/4/2015 11 KCF Technologies, Inc. -- Copyright 2014
“…fluid end has less than 50 hours on it, and the surface where the side cap seals on the middle suction bore is worn. This is causing leaking during the stage, which means it’s sucking air through this hole and causing cavitation.”
• Running pumps in 4th gear results in much higher vibration and is suspected to have caused iron mount bolt failures.
Pumps in 4th Gear = Increased Damage
KCF Technologies, Inc. Proprietary & Confidential -- Copyright 2014 10/4/2015 12
Example of a pump which ran in 3rd gear for and then was changed to 4th gear, which may have caused an iron mount failure.
Improved Safety in the Marcellus – Reduction of Incidents (NPT)
KCF Technologies, Inc. Proprietary & Confidential -- Copyright 2014 10/4/2015 13
Fluid End Hours
Pump Truck Hours/Baseline##01 112%##02 145%##03 120%##04 240%##05 14%##06 266%##07 206%##08 121%##09 135%##10 69%##11 257%##12 203%##13 302%##14 200%##15 160%
Average 170%