UPRIGHT TANK - austria-email.com
Transcript of UPRIGHT TANK - austria-email.com
UPRIGHT TANK
HIGH-PERFORMANCEHEAT EXCHANGER UPRIGHT TANKHRS 200HRS 300HRS 400HRS 500HRS 750HRS 900
HIGH-PERFORMANCE HEAT EXCHANGER UPRIGHT TANK - HRS 200, 300, 400, 500
This is Austria Email’s answer to the growing demand for low return temperatures in the heating cir-cuit: a cylinder with very large heating surfaces. With its double-coiled straight-tube heat exchanger providing an exceptionally high transfer performance, this water heater is the first choice for energy-conscious applications, such as zero-energy homes or heat pump systems.
Thermometer
500 litres as shown200 litres,300 litres and 400 litres approximately 60mm thread
Adjustable feet 3x120°
Sensorchannel
PU insulation
Magnesium anode 500 lt. Magnesium anode 200, 300 lt. and 400 lt.
Max.Installation length
HRS 200, 300, 400, 500
n Internal boiler enamelled according to DIN 4753 T3 n Operating pressure: max. 10 barn Operating temperature: max. 95 °Cn Straight-tube heat exchanger with very large heating sur-
facesn Energy-saving 50 mm PU insulationn Foil jacket packed separately (silver-grey)n Circulation: 3/4“ male thread for HRS 200-400, 1“ male thread for HRS 500n Variable sensor position (sensor channel)n High-quality dial thermometer attachedn DIN 4753 T3-compliant magnesium sacrificial anoden 6/4‘‘ sleeve for SH screw-in heater for electrical backup
heating (sealed)n Adjustable feet
ACCESSORIES:
n Mounted thermometer charge pump controller combina-tion ATR
n Flange immersion heater, 180 mmn 6/4“ screw-in heater, "SH" seriesn Impressed current anode (add-on kit)n Finned tube heat exchangern For more information, please see our accessories
brochure
HRS 300
HRS 400
HRS 500
HRS 200 kW
kW
kW
kW
l/h
l/h
l/h
l/h
70°C 70°C 70°C 70°C 80°C 80°C 80°C 80°C 70°C 70°C 70°C 70°C 80°C 80°C 80°C 80°C45°C 45°C 45°C 45°C 45°C 45°C 45°C 45°C 60°C 60°C 60°C 60°C 60°C 60°C 60°C 60°C10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C
500l/h 1000l/h 2000l/h 3000l/h 500l/h 1000l/h 2000l/h 3000l/h 500l/h 1000l/h 2000l/h 3000l/h 500l/h 1000l/h 2000l/h 3000l/h
19,748624,760827,868428,6704
30,274438,795246,8115147,91178
4098558
142772
177175
1845
45110769,7171588,5217791,82258
24,861030,374433,883034,4846
37,893048,8119957,6141759
1451
50,4123975
184594
231294
2312
56,8139689,72207115,52841114,72820
16,227820,53532441324,9429
24,441931,253738,566340689
32551457755798260
1033
366195391369
118871,81236
22,238227,146630,953131,8548
33,75804374052,490153,1914
4577464
110282
141282
1412
50,987476,51316100,2172599,41712
Supply temperature
Hot water temperatureCold water temperatureHeating circuit flow rate
Throughput performance in kW
ø DH
1295143518001806
A
HRS 300
HRS 400
HRS 500
B C E F G I
610680680760
305320320350
78084010001040
84099012601290
1057116015251500
305345345370
1067115615211498
980105013301360
1450159519301970
2,53,55,06,0
16,222,632,239,6
115170212254
6142124
520590590670
HRS 200 375450450530
Diagonal height in mm
Type
Pipe array
heatingsurface
in m2
Pipearraycapa-cityin l
Weightin kg
NLnumber
ETE2)
in mm
Dimensions in mm
ETF1)
in mm
2) Installation depth of screw-in heater steeve for SH heating1) Installation depth of flange (for built-in heater of finned tube heat exchanger)
HIGH-PERFORMANCE HEAT EXCHANGER UPRIGHT TANK - HRS 750, 900
Sensorchannel(2x)
THHotwater
Supply
Circulation
Return
Cold water
G3/4‘‘ Impressedcurrent anode
EH
HRS 750, 900
n Internal boiler enamelled according to DIN 4753 T3 n Operating pressure: max. 10 barn Operating temperature: max. 95 °Cn Straight-tube heat exchanger with very large heating sur-
facesn With new, 100 mm ECO SKIN insulationn Circulation: 5/4‘‘n Variable sensor position (sensor channel)n High-quality dial thermometer attachedn With built-in impressed current anoden 6/4‘‘ sleeve for SH screw-in heater for electrical backup
heating (sealed)
ACCESSORIES:
n Mounted thermometer charge pump controller combination ATRn Flange immersion heater, 240 mmn 6/4‘‘ screw-in heater, "SH" seriesn Impressed current anode (add-on kit)n Finned tube heat exchangern For more information, please see our accessories brochure
Diagonal height in mmø DH
18822228
A
Type
HRS 750
HRS 900
B C E F
Pipe array
heatingsurface
in m2
Pipearraycapa-cityin l
Weightin kg
NLnumber
ETE2)
in mm
790790
12651445
10001180
11651345
13101490
15801920
19602300
6,07,5
39,649,7
317374
3442
850850
Dimension in mm
H with insulation
20002350
ETF1)
in mm
850850
2) Installation depth of screw-in heater steeve for SH heating1) Installation depth of flange (for built-in heater of finned tube heat exchanger)
HRS 900
HRS 750 kW
kWl/h
l/h
70°C 70°C 70°C 70°C 80°C 80°C 80°C 80°C 70°C 70°C 70°C 70°C 80°C 80°C 80°C 80°C45°C 45°C 45°C 45°C 45°C 45°C 45°C 45°C 60°C 60°C 60°C 60°C 60°C 60°C 60°C 60°C10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C 10°C500l/h 1000l/h 2000l/h 3000l/h 500l/h 1000l/h 2000l/h 3000l/h 500l/h 1000l/h 2000l/h 3000l/h 500l/h 1000l/h 2000l/h 3000l/h
28,570030,5765
46,8114954,51347
71,3175284,92097
87,42147103,42555
3586036,9912
59,1145266,31639
92,12262104,72588
1142801128,53174
22,639027468
34,459146,7811
49,785570,51223
59,4102184,81471
2950034,6601
48,483261,21061
72,1124095,11650
87,41503116,12014
Supply temperatureHot water temperature
Cold water temperatureHeating circuit flow rate
Throughput performance in kW
WE MANUFACTUREIN AUSTRIA ANDDELIVER TO EUROPE ©
ww
w.a
gent
ur-s
char
f.at –
240
.828
– 1
5091
5 –
HR
S –
Prin
ted
on e
nviro
nmen
tally
frie
ndly
pap
er fr
ee fr
om c
hlor
ine.
Tec
hnic
al c
hang
es a
nd m
ispr
ints
rese
rved
.
Head office and factory: Austria Email AGA-8720 Knittelfeld, Austriastrasse 6 Phone (03512) 700-0, Fax (03512) 700-239 Internet: www.austria-email.at E-mail: [email protected]
Customer Service: Phone (03512) 700-297E-mail: [email protected]
Sales offices Germany:
Germany North/East D-14770 Brandenburg, Beetzseeufer 3Phone 0049/(0)3381 / 766-0Fax 0049/(0)3381 / 766-244 E-mail: [email protected]
Germany South D-92637 Weiden/Opf., Parksteiner Strasse 49Phone 0049/(0)961 / 63 490-0Fax 0049/(0)961 / 63 490-30E-mail: [email protected]
XLXXLXXL3XL3XL4XL
1,672,082,452,722,562,87
ECO DESIGN - LABELING
HRS 200HRS 300HRS 400HRS 500HRS 750HRS 900
200300400500750900
69,6 86,7102,1113,3106,7119,6
CCCC--
Type
in kWh/24h Zapf Profilein Watt
Heat loss in EN 12897 EnergyEfficiency
ClassContentin litres