Upflow/Horizontal Gas Furnace

9
MAN-SS-R801P-0116 intensity.mx Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E.† Input Rates 50-150 kBTU A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.

Transcript of Upflow/Horizontal Gas Furnace

Page 1: Upflow/Horizontal Gas Furnace

MAN-SS-R801P-0116intensity.mx

Upflow/Horizontal Gas FurnaceR801P- Upflow/Horizontal Series

80% A.F.U.E.†Input Rates 50-150 kBTU

A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance withDepartment of Energy test procedures.

Page 2: Upflow/Horizontal Gas Furnace

TABLE OF CONTENTSStandard & Optional Equipment ......................................................................3Model Features/Physical Data & Specifications..................................................4Model Number Identification ............................................................................5Dimensional Data ........................................................................................6-7Blower Performance Data ................................................................................8Accessories....................................................................................................9

• 80% residential Gas Furnace CSA certified• 3 way multi poise design UF / HZ• PlusOne™ Diagnostics — 7 Segment LED all units• PlusOne™ Ignition System – DSI for reliability and longevity• Heat exchanger is removable for improved serviceability.

Aluminized steel construction provides maximum corrosionresistance and thermal fatigue reliability.

• Solid doors provide quiet operation• Solid bottom• Insulated blower compartment

• Low profile 34" cabinet ideal for space constrainedinstallations

• Blower shelf design – serviceable in all furnace orientations• Hemmed edges on cabinets and doors• 1/4 turn door knobs for tool less access• Integrated Control board features dip switches for easy

system set up• QR code for quick access to product information from your

smart phone or tablet

intensity.mx2

Table of ContentsR801P (UF/HZ) Series

Page 3: Upflow/Horizontal Gas Furnace

Standard & Optional EquipmentR801P (UF/HZ) Series

3

WARNINGTHIS FURNACE IS NOT APPROVED

OR RECOMMENDEDFOR USE IN MOBILE HOMES

DIRECT SPARK IGNITOR

IN-SHOT BURNERS

DRAFT INDUCER MOTOR

PATENTED HEAT EXCHANGER

INTEGRATEDFURNACECONTROL

STANDARD EQUIPMENTCompletely assembled and wired; induced draft; pressure switch;redundant main gas control; blower compartment door safety switch;solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas;transformer; direct drive multi-speed blower motor. Furnaces areequipped with cooling/heating relay and transformer (40VA) ready forair conditioning applications. (Please note: a thermostat is notincluded as standard equipment.) Flame sensor diagnostics.

OPTIONAL EQUIPMENTSide and bottom filter frame assembly. Return air cabinet for all sizes.NOTE: Furnace is not listed for use with fuels other than natural or L.P.

(propane) gas.The complete terms of limited and other warranties are available at oursales office, or through local installer.All models can be converted by a qualified Intensity distributor or localservice dealer to use L.P. (propane) gas without changing burners.Factory approved kits must be used to convert from natural to L.P.(propane) gas and may be ordered as optional accessories from aIntensity parts distributor.For L.P. (propane) operation, refer to Conversion Kit Index Form.NOTE: For natural and L.P. (propane) gas models, direct spark ignitionis 100% safety lockout type.

intensity.mx

Page 4: Upflow/Horizontal Gas Furnace

Model Features/Physical Data & SpecificationsR801P (UF/HZ) Series

MODEL NUMBERS R801P SERIES R801PA050314M*A R801PA075317M*A R801PA075417M*A R801PA100417M*A R801PA100521M*A R801PA125524M*A R801PA150524M*A

Input-BTU/Hr 50,000 75,000 75,000 100,000 100,000 125,000 150,000

Heating Capacity BTU/Hr 40,000 60,000 60,000 80,000 80,000 100,000 120,000

Heat Ext. Static Pressure .18 .20 .20 .28 .28 .28 .28

Blower (D x W) 11 x 6 11 x 7 11 x 7 11 x 7 11 x 10 11 x 10 11 x 10

Motor H.P.–Speed–Type 1/3-4-PSC 1/2-4-PSC 1/2-4-PSC 1/2-4-PSC 1/2-4-PSC 3/4-4-PSC 3/4-4-PSC

Motor Full Load Amps 5.7 6.7 7.8 7.8 7.5 8.4 9.3

Heating Speed Med-Low Med-High Med-High Med-High Med-Low Med-High Med-High

Cooling Speed High Med-High High High High High High

Cooling CFM @ 70" W.C. E.S.P. 1164 1198 1657 1582 1807 1742 1916

Max. E.S.P. (In. W.C.) 0.8 0.8 0.8 0.8 0.8 0.8 0.8

Temperature Rise Range °F 25-55 25-55 25-55 35-65 35-65 35-65 45-75

Max. Outlet Air Temp. °F 155 155 155 165 180 165 190

Approx. Shipping Weight (Lbs.) 110 110 125 110 140 150 160

AFUE 80.0% 80.0% 80.0% 80.0% 80.0% 80.0% 80.0%

NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1/2" N.P.T.In accordance with D.O.E. test procedures.See Conversion Kit Index Form for high altitude derate.

* S = Standard, X = Low Nox

• 80% residential Gas Furnace CSA certified• 3 way multi poise design UF / HZ• PlusOne™ Diagnostics — 7 Segment LED all units• PlusOne™ Ignition System – DSI for reliability and longevity• Heat exchanger is removable for improved serviceability.

Aluminized steel construction provides maximum corrosionresistance and thermal fatigue reliability.

• Solid doors provide quiet operation• Solid bottom• Insulated blower compartment

• Low profile 34" cabinet ideal for space constrained installations

• Blower shelf design serviceable in all furnace orientations• Hemmed edges on cabinets and doors• 1/4 turn door knobs for tool less access• Integrated Controls board features dip switches for easy

system set up• QR code for quick access to product information from your

smart phone or tablet

Model Features

Physical Data and Speci�cations

intensity.mx4

Page 5: Upflow/Horizontal Gas Furnace

R 80 1 P A 075 4 17 M S A

80 =80% AFUE

1 = Single Stage P = PremiumPSC

Design SeriesA = 1st Design

InputBTU/HR [kW]050 = 50,000075 = 75,000100 = 100,000125 = 125,000150 = 150,000

3 = Up to3 Ton

4 = 21/2 to4 Ton

5 = 31/2 to5 Ton

CabinetWidth

14 = 14".017 = 17.5"21 = 21".024 = 24.5"

M = Multi X = Low NOx

S = StandardRevision-Marketing

(A – First TimeRelease)

5intensity.mx

Model Number IdentificationR801P (UF/HZ) Series

Page 6: Upflow/Horizontal Gas Furnace

Dimensional DataR801P (UF/HZ) Series

6

Up�ow Application

MODELR801P- A B C D E F

MINIMUM CLEARANCE (IN.) SHIPWGTS.(LBS.)

LEFTSIDE

RIGHTSIDE BACK TOP FRONT VENT

050 141/2 1227/32 105/8 111/2 17/8 0 4 0 1 3 6 85075/

100417 171/2 1611/32 123/8 151/2 21/2 0 3 0 1 3 6 105

100521 211/2 1927/32 141/8 181/2 21/2 0 0 0 1 3 6 120125 241/2 2311/32 157/8 221/2 21/2 0 0 0 1 3 6 140150 241/2 2311/32 157/8 221/2 21/2 0 0 0 1 3 6 150.

NOTES: May require a 3" to 4" or 3" to 5" adapter. May be 0" with type B vent.May be 1" with type B vent.

Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance withlocal codes.

Dimensional Data: Up�ow Model

intensity.mx6

Page 7: Upflow/Horizontal Gas Furnace

Dimensional DataR801P (UF/HZ) Series

Horizontal Application

MODELR801P- A B C D E F

MINIMUM CLEARANCE (IN.) SHIPWGTS.(LBS.)

SUPPLYAIR SIDE

RETURNAIR SIDE BACK TOP FRONT VENT

050 141/2 1227/32 105/8 111/2 17/8 0 4 0 1 3 6 85075/

100417 171/2 1611/32 123/8 151/2 21/2 0 3 0 1 3 6 105

100521 211/2 1927/32 141/8 181/2 21/2 0 0 0 1 3 6 120125 241/2 2311/32 157/8 221/2 21/2 0 0 0 1 3 6 140150 241/2 2311/32 157/8 221/2 21/2 0 0 0 1 3 6 150.

NOTES: May require a 3" to 4" or 3" to 5" adapter. May be 0" with type B vent.May be 1" with type B vent.

Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance withlocal codes.

Dimensional Data: Horizontal Model

WARNINGTHIS FURNACE IS NOT APPROVED

OR RECOMMENDED FOR INSTALLATIONON ITS BACK, WITH ACCESS DOORS

FACING UPWARDS.

7intensity.mx

Page 8: Upflow/Horizontal Gas Furnace

Blower Performance DataR801P (UF/HZ) Series

MODELMOTOR H.P. [W]

BLOWER SIZE IN

SPEEDTAP

CFM AIR DELIVERYEXTERNAL STATIC PRESSURE INCHES WATER COLUMN

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

(-)801PA050314M*A 1/311 x 6

LowMed. LoMed. Hi

High

823103011291361

803101811321353

787100611121331

732976

10871297

718929

10541264

691897

10281232

651850971

1164

593808919

1117

(-)801PA075317M*A 1/211 x 7

LowMed. LoMed. Hi

High

1008121514211668

977118114081648

935113313721633

893109813261580

854106512991545

823102312471481

777975

11981442

735937

11521373

(-)801PA075417M*A 1/211 x 7

LowMed. LoMed. Hi

High

1229130815531969

1200126715421924

1181126615161893

1155123314911840

1120120414511803

1078117614171728

1013111313581657

970106213061570

(-)801PA100417M*A 1/211 x 7

LowMed. LoMed. Hi

High

1211130515201874

1183126114981810

1148122514641767

1116118514271686

1077115713871678

1040111313401650

984106812921582

953101212261497

(-)801PA100521M*A 1/211 x 10

LowMed. LoMed. Hi

High

1209143819022071

1182142018832037

1131138618442001

1112135018171962

1051132017531905

976129317001856

929124816361807

867118615471709

(-)801PA125524M*A 3/411 x 10

LowMed. LoMed. Hi

High

1358154117992015

1354151717741989

1331147617461929

1301145317121902

1250141616911862

1224137116291815

1154133915541742

1089127714951665

(-)801PA150524M*A 3/411 x 10

LowMed. LoMed. Hi

High

1411160618892178

1395157918912160

1370156918492105

1334153718282067

1310149917642024

1252146817171976

1220140716591916

1150134616091832

Note:Bold data is factory heating tap.Table represents blower performance data WITHOUT �lters.

Blower Performance Data

intensity.mx8

Page 9: Upflow/Horizontal Gas Furnace

AccessoriesR801P (UF/HZ) Series

9

FILTER RACK FILTER SIZES* INCHES

MODELRXGF-CB

(UPFLOW/HORIZONTAL)

RXGF-CD(UPFLOW)

SIDE RETURN

R801PA050 121/4 x 25 153/4 x 25

R801PA075/R801PA100417 153/4 x 25 153/4 x 25

R801PA100521 191/4 x 25 153/4 x 25R801PA125 223/4 x 25 153/4 x 25R801PA150 223/4 x 25 153/4 x 25

WARNING: IMPORTANT NOTICEA SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THEFURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TOINSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TOBE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLYHAZARDOUS CONDITIONS.

FURNACE SOLID BASE BASEWIDTH BOTTOM PLATE NO. PLATE SIZE

.NI.ON TIK.NI141/2 RXGB-D14 AE-61874-01 115/8 x 239/16

171/2 RXGB-D17 AE-61874-02 151/8 x 239/16

211/2 RXGB-D21 AE-61874-03 185/8 x 239/16

241/2 RXGB-D24 AE-61874-04 255/8 x 239/16

FOR HIGH ALTITUDES:OPTION CODE FOR HIGH ALTITUDE: U.S. & CanadaNone required for high altitudes.HIGH ALTITUDE CONVERSION KITS: U.S. & CanadaNone required for high altitudes.80+ HIGH ALTITUDE INSTRUCTIONS CAUTION:Always follow National Fuel Gas Code (NFGC) guidelineswhen converting for high altitudes.High altitude option codes are not required for these models.However, the burner ori�ce size needs to be recalculated and veri�edat elevations above 2000 ft. See Installation Instructions for moreinformation.NOTE: For Canadian installations only, an optional derate (manifold

gas pressure reduction) method may be used to adjust thefurnace for altitude. See Installation Instructions for moreinformation. This optional method may NOTbe used for U.S.installations.

SIDE RETURN FILTER RACK:RXGF-CDBOTTOM RETURN FILTER RACK FORUPFLOW APPLICATION:RXGF-CB

INDOOR COIL CASINGS

MODEL NUMBER

RXBC-D14AIRXBC-D17AIRXBC-D21AIRXBC-D21BIRXBC-D24AI

4" FLUE ADAPTER:RXGW-C01