Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008)...

7
www.tridonic.com 1 Subject to change without notice. Data sheet 11/11-LED017-1 U – LED modules, converters and systems GENERAL ILLUMINATION Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board technololgy Beam characteristic: 140° Uniform distribution of light Attached with M3 screws Connection: Cable 300 mm Built-in LED module Cooling required Technical data Weight 8 g Typ. power at 350 mA 26 13.3 W Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT P310-2 umodule SPOT 36 33 tc Ø 3.2 NTC 1 Minimal reflector diameter 2 Maximum reflector diameter Ø23.5 1 Ø32 2 1.65 2.00 typ. 3 3 Ordering data Colour temperature Type Article number 3,000 K LED P310-2 3000K 36x33 89601100 3,000 K LED P310-2 3500K 36x33 89601360 4,000 K LED P310-2 4000K 36x33 89601101 5,000 K LED P310-2 5000K 36x33 89601355 Packaging: 20 pieces/carton Specific technical data Type Min. luminous flux at 350 mA 23 Typ. luminous flux at 350 mA 23 Typ. forward current 45 Max. forward current 45 Min. forward voltage 26 Typ. forward voltage 26 Max. forward voltage 26 Colour rendering index CRI LED P310-2 3000K 36x33 800 lm 900 lm 350 mA 700 mA 33.3 V 38 V 44.8 V > 80 LED P310-2 3500K 36x33 810 lm 900 lm 350 mA 700 mA 33.3 V 38 V 44.8 V > 80 LED P310-2 4000K 36x33 900 lm 1.000 lm 350 mA 700 mA 33.3 V 38 V 44.8 V > 80 LED P310-2 5000K 36x33 950 lm 1.050 lm 350 mA 700 mA 33.3 V 38 V 44.8 V > 80 1 If the maximum temperature limits are exceeded, the life of the module will be greatly reduced or the module may be damaged. The temperature of the umodule SPOT at the tc point in the thermally stable state by mean of a temperature sensor or temperature-sensitive sticker as per EN 60598-1. For the precise position of the tc point see the drawing above. 2 At tc = 65 °C 3 Tolerance range for optical data: ±15 %. 4 Permitted current range see diagram on page 4. Exceeding the maximum operating current leads to an overload of the umodule SPOT. This may in turn result in a significant reduction of lifetime or even in damage of the umodule SPOT. 5 Max. permissible surge current: 1.25 A, duration max. 10 μs 6 Tolerance range for electrical data: ±15 %. All values for ta = 25 °C. PHASED OUT

Transcript of Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008)...

Page 1: Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT

www.tridonic.com 1Subject to change without notice.

Data sheet 11/11-LED017-1

U – LED modules, converters and systemsGENERAL ILLUMINATION

Product description

•Spotlights

•Downlights

•High-flux LED module

•Narrow colour temperature tolerance band

•Compact design

•Excellent thermal management1

•NTC for temperature control

•High-power LED in chip-on-board technololgy

•Beam characteristic: 140°

•Uniform distribution of light

•Attached with M3 screws

•Connection: Cable 300 mm

•Built-in LED module

•Cooling required

Technical dataWeight 8 g

Typ. power at 350 mA2 6 13.3 W

Risk group (EN 62471:2008) 0

ÈStandards, page 3

Colour temperatures and tolerances, page 6, 7

Umodule SPOT P310-2umodule SPOT

36

33

tc

Ø 3.

2

NTC

1 Minimal reflector diameter2 Maximum reflector diameter

Ø23.

5 1

Ø32

2

1.652.00 typ.3

3

Ordering dataColour temperature Type Article number

3,000 K LED P310-2 3000K 36x33 89601100

3,000 K LED P310-2 3500K 36x33 89601360

4,000 K LED P310-2 4000K 36x33 89601101

5,000 K LED P310-2 5000K 36x33 89601355Packaging: 20 pieces/carton

Specific technical dataType Min. luminous flux

at 350 mA2 3Typ. luminous flux

at 350 mA2 3Typ. forward current4 5

Max. forward current4 5

Min. forward voltage2 6

Typ. forward voltage2 6

Max. forward voltage2 6

Colour rendering index CRI

LED P310-2 3000K 36x33 800 lm 900 lm 350 mA 700 mA 33.3 V 38 V 44.8 V > 80

LED P310-2 3500K 36x33 810 lm 900 lm 350 mA 700 mA 33.3 V 38 V 44.8 V > 80

LED P310-2 4000K 36x33 900 lm 1.000 lm 350 mA 700 mA 33.3 V 38 V 44.8 V > 80

LED P310-2 5000K 36x33 950 lm 1.050 lm 350 mA 700 mA 33.3 V 38 V 44.8 V > 801 If the maximum temperature limits are exceeded, the life of the module will be greatly reduced or the module may be damaged.

The temperature of the umodule SPOT at the tc point in the thermally stable state by mean of a temperature sensor or temperature-sensitivesticker as per EN 60598-1. For the precise position of the tc point see the drawing above.

2 At tc = 65 °C

3 Tolerance range for optical data: ±15 %.

4 Permitted current range see diagram on page 4.Exceeding the maximum operating current leads to an overload of the umodule SPOT.This may in turn result in a significant reduction of lifetime or even in damage of the umodule SPOT.

5 Max. permissible surge current: 1.25 A, duration max. 10 μs

6 Tolerance range for electrical data: ±15 %.

All values for ta = 25 °C.

PHASED

OUT

Page 2: Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT

www.tridonic.com 2Subject to change without notice.

Data sheet 11/11-LED017-1

U – LED modules, converters and systemsGENERAL ILLUMINATION

Converter / controls matrix – Umodule SPOT P310-2

Converter REMOTE LCI Controls IN-BUILT

TypeLCAI 15 W350 mA one4all

LCAI 30 W700 mAone4all

LCI 15 W350 mA

LCI 30 W700 mA

LCCI 16 W350 mA

C350-2 4-Channel C350 dim C700 dim

Article number 86458899 86458900 24166312 24166314 86459210 86458693 86458944 86458945

Assignable converter Assignable controls

Type Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.

Umodule SPOT P310-2 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1

PHASED

OUT

Page 3: Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT

www.tridonic.com 3Subject to change without notice.

Data sheet 11/11-LED017-1

U – LED modules, converters and systemsGENERAL ILLUMINATION

Typical heat sink surface

NotesValues valid for: natural convection, heat sink material: aluminium ≥ 1 mm thick, Rth, hs-a = required thermal resistance of heat sink

The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule SPOT and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary.Additionally the umodule SPOT has to be fixed on the heat sink with M3 plastic screws to optimise the thermal connection.

Umodule SPOT P310-2, 350 mAta tc Rth, hs-a typical heat sink surface25 °C 65 °C 4.36 K/W 153 cm²30 °C 65 °C 3.79 K/W 176 cm²40 °C 65 °C 2.66 K/W 251 cm²50 °C 65 °C 1.53 K/W 436 cm²

For umodule SPOT P310-2 a tc temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time.

Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application.

Mounting instruction

umodule SPOT from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 plastic screws.

The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease.

None of the components of the umodule SPOT (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses.

For further information please refer to to the brochure entitled “u installation instructions and guidelines”.

Temperature controlAn NTC resistor is on the board of the umodule SPOT P310-2 to control the tc temperature during the operation.Exact position see drawing on page 1.The details of the 220 kΩ NTC (order number B57431V2223J062) you can find in the data sheet of the manufacturer AVX (Nr. NB12QØØ224).

T R25 = 220 kΩ, B25 / 100 = 4,500 K

RT / R25 α

25 °C 1.0000 4.8 % / K

30 °C 0.78759 4.7 % / K

35 °C 0.62406 4.6 % / K

40 °C 0.49737 4.5 % / K

45 °C 0.39863 4.4 % / K

50 °C 0.32123 4.3 % / K

55 °C 0.26022 4.2 % / K

60 °C 0.21186 4.1 % / K

65 °C 0.17334 4.0 % / K

70 °C 0.14249 3.9 % / K

75 °C 0.11767 3.8 % / K

80 °C 0.097598 3.7 % / K

85 °C 0.081300 3.6 % / K

Thermal design and heat sinkThe rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule SPOT will be greatly reduced or the umodule SPOT may be destroyed.

Therefore the umodule SPOT P310-2 needs to be mounted onto a heat sink.

Tridonic’s excellent thermal design for the umodule SPOT products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time.

tc point, ambient temperature and lifetimeThe temperature at tc reference point is crucial for the light output and life time of a u product.

Thermal behaviour

storage temperature -30 – 85 °Coperating temperature -30 – 50 °Ctc max. (at typ. current) 85 °C

0

200

400

600

800

1000

1200

1400

1600

0 10 20 30 40 50 60 70 80 90 100Tc [°C]

If [m

A]

StandardsEN 62031EN 62471

Umodule SPOT P310-2, 700 mAta tc Rth, hs-a typical heat sink surface25 °C 65 °C 2.09 K/W 318 cm²30 °C 65 °C 1.81 K/W 368 cm²40 °C 65 °C 1.24 K/W 536 cm²50 °C 65 °C 0.68 K/W 982 cm²

f(soldering time) for the modules

Temperature Max. timewithout heat sink

Max. timewith optimized heat sink

330 °C 15 s –340 °C 12 s –350 °C 10 s –360 °C 5 s 15 s370 °C 3 s 12 s380 °C 2 s 10 s390 °C 1 s 5 s

Matrix temperature

The values apply for soldering without heat sink. To reduce the duration of soldering it is recommended to pre-heat the module at ta max., e.g. on a plate.

PHASED

OUT

Page 4: Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT

www.tridonic.com 4Subject to change without notice.

Data sheet 11/11-LED017-1

U – LED modules, converters and systemsGENERAL ILLUMINATION

Electrical supply/choice of converterumodule SPOT from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a converter which complies with the relevant standards. The use of u converters from Tridonic in combination with umodule SPOT guarantees the necessary protection for safe and reliable operation.

If a converter other than Tridonic uconverter is used, it must provide the follow-ing protection:•Short-circuitprotection•Overloadprotection•Overtemperatureprotection

umodule SPOT P310-2 must be supplied by a constant current converter.Operation with a constant voltage converter will lead to an irreversible damage of the module.

Wrong polarity can damage the umodule SPOT P310-2.

WiringCable: AWG24; length 300 mm

colour red black grey greyfunction + - NTC NTC

tc temperature in °C luminous flux in % lifetime in h

2580 29,00070 47,00050 91,000

4580 28,00070 45,00050 87,000

6580 26,00070 42,00050 81,000

7580 23,00070 35,00050 75,000

8580 15,00070 22,00050 49,000

Lifetime

EOS/ESD safety guidelines

The device / module contains components that are sensitive to electro-static discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation prac-tice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp

PHASED

OUT

Page 5: Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT

www.tridonic.com 5Subject to change without notice.

Data sheet 11/11-LED017-1

U – LED modules, converters and systemsGENERAL ILLUMINATION

The diagrams based on statistic values.The real values can be different.

0,97

0,98

0,99

1

1,01

1,02

1,03

1,04

1,05

20 30 40 50 60 70Tc [°C]

rel.

volta

ge [a

.u.]

80 85

0,92

0,94

0,96

0,98

1

1,02

1,04

1,06

1,08

1,1

1,12

1,14

30 40 50 60 85Tc [°C]

rel.

lum

inou

s flu

x [a

.u.]

20 8070

0,6

0,8

1,0

1,2

1,4

1,6

1,8

400200 800 900600current [mA]

rel.

volta

ge [a

. u.]

Relative forward voltage at tc = 65 °C

300 500 700100

2,0

0,20

0,40

0,60

0,80

1,00

1,20

1,40

1,60

100 200 300 400 500 600 700 800 900

current [mA]

rel.

lum

inou

s flu

x [a

.u.]

Relative luminous flux at tc = 65 °C

Relative forward voltage and relative luminous flux

Optical characteristics Umodule SPOT P310-2

The optical design of the umodule SPOT product line ensures optimumhomogenity for the light distribution.

20

20

-20 40

40

60

60

80

100

80 100-40-60-80-100

10°-10° 20°-20°-30°

-40°

-50°

-60°

30°

40°

50°

60°

70°

80°

90°-90°0

rela

tive

inte

nsity

Iv/Iv

, max

Umodule SPOT P310-2 140°: Light distribution

PHASED

OUT

Page 6: Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT

www.tridonic.com 6Subject to change without notice.

Data sheet 11/11-LED017-1

U – LED modules, converters and systemsGENERAL ILLUMINATION

Coordinates and tolerances according to CIE 1964

The specified colour coordinates are measured by a current impulse of 350 mA and a duration of 100 ms.The ambient temperature of the measurement is ta = 25 °C.The measurement tolerance of the colour coordinates are ± 0.01.

MacAdam ellipse: 5SDCM

MacAdam ellipse: 5SDCM

0,3700

0,3750

0,3800

0,3850

0,3900

0,3950

0,4000

0,4050

0,4100

0,3950

0,4000

0,4050

0,4100

0,4150

0,4200

0,4250

0,4300

0,4350

0,3800

0,3850

0,3900

0,3950

0,4000

0,4050

0,4100

0,4150

0,4200

0,4250

0,4300

0,4350

0,4400

0,4450

0,4500

0,4550

0,4600

0,4650

3,000 Kx0 y0

Centre 0,4460 0,3990

3,500 Kx0 y0

Centre 0,4160 0,3900

380 420 460 500 540 580 620 660 700 740 780

wave length [nm]

norm

. int

ensi

ty [%

]

0

20

40

60

80

100

380 420 460 500 540 580 620 660 700 740 780wave length [nm]

norm

. int

ensi

ty [%

]

0

20

40

60

80

100

PHASED

OUT

Page 7: Umodule SPOT P310-2 umodule SPOT OUT PHASEDTyp. power at 350 mA26 13.3 W Risk group (EN 62471:2008) 0 È Standards, page 3 Colour temperatures and tolerances, page 6, 7 Umodule SPOT

www.tridonic.com 7Subject to change without notice.

Data sheet 11/11-LED017-1

U – LED modules, converters and systemsGENERAL ILLUMINATION

MacAdam ellipse: 5SDCM

0,3450

0,3500

0,3550

0,3600

0,3650

0,3700

0,3750

0,3800

0,3350

0,3400

0,3450

0,3500

0,3550

0,3600

0,3650

0,3700

0,3750

0,3400

5,000 Kx0 y0

Centre 0,3530 0,3590

380 420 460 500 540 580 620 660 700 740 780wave length [nm]

norm

. int

ensi

ty [%

]

0

20

40

60

80

100

MacAdam ellipse: 5SDCM

0.3600

0.3650

0.3700

0.3750

0.3800

0.3850

0.3900

0.3950

0.4000

0.3650

0.3700

0.3750

0.3800

0.3850

0.3900

0.3950

0.4000

0.4050

4,000 Kx0 y0

Centre 0,3860 0,3780

380 420 460 500 540 580 620 660 700 740 780

wave length [nm]

norm

. int

ensi

ty [%

]

0

20

40

60

80

100

PHASED

OUT