Tubos MBT y Su Colocacion en La Molares

10
victory series™ buccal tubes MBT™ System Prescription 3Unitek 24 Upper 2 nd Non-Convertible Single - Funneled Torque Offset .018 in. L/R .022 in. -19° UL 3 067-873 1 3 067-973 1 -19° UR 3 067-872 2 3 067-972 2 Upper 1 ST Convertible Double Combination - Occlusal Headgear Torque Offset .018 in. L/R .022 in. -14° 10° L .045 068-893 068-993 -14° 10° R .045 068-894 068-994 -14° 10° L .051 068-895 068-995 -14° 10° R .051 068-896 068-996 Head Gear Upper 1 ST Convertible Single Torque Offset .018 in. L/R .022 in. -14° 10° L 3 068-897 1 3 068-997 1 -14° 10° R 3 068-898 2 3 068-998 2 Upper 1 ST Convertible Double Combination - Gingival Headgear Torque Offset .018 in. L/R .022 in. Head Gear -14° 10° L .045 068-885 068-985 -14° 10° R .045 068-886 068-986 -14° 10° L .051 068-887 068-987 -14° 10° R .051 068-888 068-988 Upper 1 ST Convertible Triple Combination - Occlusal Headgear Torque Offset .018 in. L/R .022 in. Head Gear -14° 10° L .045 068-889 068-989 -14° 10° R .045 068-890 068-990 -14° 10° L .051 068-891 068-991 -14° 10° R .051 068-892 068-992 Base Base 4 Buccal Tube is available with a bondable base. 3 2 1 3 Appliance is available in APC™ II Adhesive Coated Appliance System. Note APC™ II Brackets sold in units of five. Measurements are in millimeters unless otherwise noted. APC™ II Adhesive Coated Appliance System Upper 2 ND Non-Convertible Single - Distal Notch Torque Offset .018 in. L/R .022 in. -14° 10° L 3 067-857 1 3 067-957 1 -14° 10° R 3 067-858 2 3 067-958 2 Upper 1 ST Non-Convertible Single - Funneled Torque Offset .018 in. L/R .022 in. -14° 10° UL 3 067-879 1 3 067-979 1 -14° 10° UR 3 067-878 2 3 067-978 2

Transcript of Tubos MBT y Su Colocacion en La Molares

Page 1: Tubos MBT y Su Colocacion en La Molares

victory series™ buccal tubesMBT™ System Prescription

3Unitek24

Upper 2nd Non-Convertible Single - Funneled

Torque Offset .018 in.L/R .022 in.

-19° 8° UL 3 067-873 1 3 067-973 1-19° 8° UR 3 067-872 2 3 067-972 2

Upper 1ST Convertible Double Combination - Occlusal Headgear

Torque Offset .018 in.L/R .022 in.

-14° 10° L .045 068-893 068-993-14° 10° R .045 068-894 068-994-14° 10° L .051 068-895 068-995-14° 10° R .051 068-896 068-996

Head Gear

Upper 1ST Convertible Single

Torque Offset .018 in.L/R .022 in.

-14° 10° L 3 068-897 1 3 068-997 1-14° 10° R 3 068-898 2 3 068-998 2

Upper 1ST Convertible Double Combination - Gingival Headgear

Torque Offset .018 in.L/R .022 in.Head Gear

-14° 10° L .045 068-885 068-985-14° 10° R .045 068-886 068-986-14° 10° L .051 068-887 068-987-14° 10° R .051 068-888 068-988

Upper 1ST Convertible Triple Combination - Occlusal Headgear

Torque Offset .018 in.L/R .022 in.Head Gear

-14° 10° L .045 068-889 068-989-14° 10° R .045 068-890 068-990-14° 10° L .051 068-891 068-991-14° 10° R .051 068-892 068-992

Bas

e

Bas

e

4 Buccal Tube is availablewith a bondable base.3213 Appliance is available in APC™ II Adhesive

Coated Appliance System.

Note

APC™ II Brackets sold in units of five. Measurements are in millimeters unless otherwise noted.

APC™ II Adhesive Coated Appliance System

Upper 2ND Non-Convertible Single - Distal Notch

Torque Offset .018 in.L/R .022 in.

-14° 10° L 3 067-857 1 3 067-957 1-14° 10° R 3 067-858 2 3 067-958 2

Upper 1ST Non-Convertible Single - Funneled

Torque Offset .018 in.L/R .022 in.

-14° 10° UL 3 067-879 1 3 067-979 1-14° 10° UR 3 067-878 2 3 067-978 2

Page 2: Tubos MBT y Su Colocacion en La Molares

victory series™ buccal tubesMBT™ System Prescription

USA and PR 800.423.4588Canada 800.443.1661

25

Lower 1ST Convertible Double

Torque Offset .018 in.L/R .022 in.

-20° 0° L 3 067-861 3 3 067-961 3-20° 0° R 3 067-860 4 3 067-960 4

Lower 1ST Convertible Single

Torque Offset .018 in.L/R .022 in.

-20° 0° L 3 067-819 3 3 067-919 3-20° 0° R 3 067-820 4 3 067-920 4

Lower 2ND Non-Convertible Single - Distal Notch

Torque Offset .018 in.L/R .022 in.

-10° 0° L 3 067-816 3 3 067-916 3-10° 0° R 3 067-815 4 3 067-915 4

Lower 1ST Non-Convertible Single - Funneled

Torque Offset .018 in.L/R .022 in.

-20° 0° LL 3 067-877 3 3 067-977 3-20° 0° LR 3 067-876 4 3 067-976 4

Lower 1ST Non-Convertible Single

Torque Offset .018 in.L/R .022 in.

-20° 0° L 3 067-867 3 3 067-967 3-20° 0° R 3 067-868 4 3 067-968 4

Bas

e

APC™ II Adhesive Coated Appliance System

Bas

e

Upper

Buccal Tubes for Partially Erupted Second Molars

Torque Offset .018 in.L/R .022 in.

-14° 0° L 3 066-407 1 3 066-507 1-14° 0° R 3 066-408 2 3 066-508 2

Lower

Torque Offset .018 in.L/R .022 in.

-10° 0° L 3 066-403 3 3 066-503 3-10° 0° R 3 066-404 4 3 066-504 4

Bas

e

Bas

e

APC™ II Adhesive Coated Appliance System

4 Buccal Tube is availablewith a bondable base.3213 Appliance is available in APC™ II Adhesive

Coated Appliance System.

Note

APC™ II Brackets sold in units of five. Measurements are in millimeters unless otherwise noted.

Page 3: Tubos MBT y Su Colocacion en La Molares

victory series™ 2nd bicuspid tubesMBT™ System Prescription

3Unitek26

Metal Injection Molded,including integral hook

No need for ligatures to keepwire in place

No tie-wings to comeinto occlusion

Ligature wire channel(patent pending)

Chamfered tubeopening to assist inwire insertion

Same in-out dimensionas Victory Series™ 2nd Bicuspid brackets

Micro-Etched base

There is less chance ofocclusal interferencefrom tubes

• Ligation Free – no added sliding friction

• No Tie-Wings – less chance for occlusal interference

• Chamfered Tube Opening to assist in wire insertion

• Micro-Etched Base

• Available in APC™ Adhesive Coated Appliance System

• Offset Base Option

Off

set

Bas

e

AP

C™

PL

US

AP

C™

II

3 5 058-801 0 Lower Left 2nd Bicuspid Tube .018 Slot (-17° torque, 2° angulation)

3 5 058-802 0 Lower Right 2nd Bicuspid Tube .018 Slot (-17° torque, 2° angulation)

3 5 058-803 0 Upper Left / Right 2nd Bicuspid Tube .018 Slot (-7° torque, 0° angulation)

3 5 058-901 0 Lower Left 2nd Bicuspid Tube .022 Slot (-17° torque, 2° angulation)

3 5 058-902 0 Lower Right 2nd Bicuspid Tube .022 Slot (-17° torque, 2° angulation)

3 5 058-903 0 Upper Left / Right 2nd Bicuspid Tube .022 Slot (-7° torque, 0° angulation)

Note

APC™ II and APC™ PLUS Brackets sold inunits of five.

Measurements are in millimeters unless otherwise noted.

3 Use this prefix to order APC™ II AdhesiveCoated Appliance System. 5 Use this prefix to order APC™ PLUS Adhesive Coated

Appliance System with color change adhesive.

Available in APC™ II AdhesiveCoated Appliance System

Available in APC™ PLUS AdhesiveCoated Appliance System

Page 4: Tubos MBT y Su Colocacion en La Molares

Adhesión de tubosen las molares

Adhesión de tubosen las molares

Técnica MBTLPPV

Page 5: Tubos MBT y Su Colocacion en La Molares

PRIMERA MOLAR INFERIOR• En el centro de la corona. El bordeEn el centro de la corona. El bordeoclusaloclusal del tubo debe ser paralelo aldel tubo debe ser paralelo alborde lingual de la banda.borde lingual de la banda.

•• El tubo bucal debe estar paralelo aEl tubo bucal debe estar paralelo ala líneala línea intercrestaintercresta. Altura: 2.5mm.. Altura: 2.5mm.

Trevisi Hugo. Smartclip Tratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.

Posicionamiento Axial

PosicionamientoHorizontal

Page 6: Tubos MBT y Su Colocacion en La Molares

Posicionamiento vertical

••Muchas vecesMuchas veces la posición della posición deltubo setubo se veve comprometidacomprometida porporlas sobremordidas o por lalas sobremordidas o por lafuerte inclinación Lingualfuerte inclinación Lingualdebido a la Curva de Wilson.debido a la Curva de Wilson.

Considerando lasConsiderando las bandas, es recomendablebandas, es recomendablesoldar los tubos bucales más para distal,soldar los tubos bucales más para distal,dándole paralelismo condándole paralelismo con el borde lingual deel borde lingual dela banda, cementándola de acuerdo con lala banda, cementándola de acuerdo con laanatomíaanatomía deldel diente.diente.

Considerando lasConsiderando las bandas, es recomendablebandas, es recomendablesoldar los tubos bucales más para distal,soldar los tubos bucales más para distal,dándole paralelismo condándole paralelismo con el borde lingual deel borde lingual dela banda, cementándola de acuerdo con lala banda, cementándola de acuerdo con laanatomíaanatomía deldel diente.diente.

Page 7: Tubos MBT y Su Colocacion en La Molares

Error del posicionamiento horizontaldel tubo bucal en el sentido mesial,propiciando la rotación del molar.

Trevisi Hugo. SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.

Así debe ser

Page 8: Tubos MBT y Su Colocacion en La Molares

SEGUNDA MOLAR INFERIOR•• En el centro de la corona , bordeEn el centro de la corona , borde oclusaloclusaldel tubo paralelo al borde lingual de ladel tubo paralelo al borde lingual de labanda.banda.

•• El tubo bucal debe estar paralelo a la líneaEl tubo bucal debe estar paralelo a la líneaintercrestaintercresta. Altura : 2.5 mm. Altura : 2.5 mm..

Trevisi Hugo. SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.

Page 9: Tubos MBT y Su Colocacion en La Molares

PRIMERA MOLAR SUPERIOR•• En el centro de la corona clínica a laEn el centro de la corona clínica a laaltura de 3 mm.altura de 3 mm.

•• El centro del tubo debe coincidir conEl centro del tubo debe coincidir conel surcoel surco vestibularvestibular..

•• BordeBorde oclusaloclusal del tubo paralelo a ladel tubo paralelo a lalínealínea vestibularvestibular intercrestaintercresta..

•• En el centro de la corona clínica a laEn el centro de la corona clínica a laaltura de 3 mm.altura de 3 mm.

•• El centro del tubo debe coincidir conEl centro del tubo debe coincidir conel surcoel surco vestibularvestibular..

•• BordeBorde oclusaloclusal del tubo paralelo a ladel tubo paralelo a lalínealínea vestibularvestibular intercrestaintercresta..

Page 10: Tubos MBT y Su Colocacion en La Molares

SEGUNDA MOLAR SUPERIOR•• En el centro de la coronaEn el centro de la coronaclínica a la altura de 2 mm.clínica a la altura de 2 mm.

•• El centro del tubo debeEl centro del tubo debecoincidir con el surcocoincidir con el surcovestibularvestibular..

•• BordeBorde oclusaloclusal del tubodel tuboparalelo a la líneaparalelo a la línea vestibularvestibularintercrestaintercresta..

•• En el centro de la coronaEn el centro de la coronaclínica a la altura de 2 mm.clínica a la altura de 2 mm.

•• El centro del tubo debeEl centro del tubo debecoincidir con el surcocoincidir con el surcovestibularvestibular..

•• BordeBorde oclusaloclusal del tubodel tuboparalelo a la líneaparalelo a la línea vestibularvestibularintercrestaintercresta..

Trevisi Hugo.SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.