TRL-TOC CONFIGURATIONS
JUNE 2014, ANKARA
Bülent ATAMER
TRL-TOC-SS
Single Shot TOC– Not upgradable with autosampler– Direct TOC not possible
SS CONFIGURATIONS
p/n: 99-0348-2 Laboratory TC/TOC Analyzer; TRL-TOC-SS
Single shot analyzer; not upgradeable with an autosampler; includes: main unit, USB cable to connect to PC, start-up kit including 25 g catalyst and 5 ea quartz sample boats ;required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor); for 220 VAC, 50 Hz operation; additional one set of consumables kit is recommended for approximately one year operation
p/n: 99-0349-2 Laboratory TC/TOC+IC Analyzer; TRL-TOC-SS+IC
Single shot analyzer; not upgradeable with an autosampler; includes: main unit, USB cable to connect to PC, start-up kit including 25 g catalyst, 5 ea quartz sample boats and 5 ea 40 mL vial ;required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220 VAC, 50 Hz operation; additional one set of consumables kit is recommended for approximately one year operation
p/n: 99-0350-2 Laboratory TC+TN Analyzer; TRL-TOC-SS+TNSingle shot analyzer; not upgradeable with an autosampler; includes: main unit and TN unit, USB cable to connect to PC, start-up kit including 25g catalyst and 5ea combustion boats; required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220VAC, 50 Hz operation; additional one set of consumables kit is recommended for approximately one year operation
p/n: 99-0351-2 Laboratory TC/TOC+TN+IC Analyzer; TRL-TOC-SS+IC+TNSingle shot analyzer; not upgradeable with an autosampler; includes: main unit and TN unit, USB cable to connect to PC, start-up kit including 25 g catalyst, 5 ea quartz sample boats and 5 ea 40 mL vial, communication cable between PC and and TRL-TOC ;required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220 VAC, 50 Hz operation; additional one set of consumables kit is recommended for approximately one year operation
SS CONFIGURATIONS-continued
TRL-TOC-AS
TOC with or possibly with AUTOSAMPLER
AS CONFIGURATIONS
p/n: 99-0989-2 Laboratory TC/TOC Analyzer; TRL-TOC-AS-SSSingle shot analyzer; upgradeable with an autosampler; includes: main unit, USB cable to connect to PC, start-up kit including 25 g catalyst and 5 ea quartz sample boats ;required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor); for 220VAC, 50 Hz operation; additional one set of consumables kit and more quartz sample boats are recommended for approximately one year operation
p/n: 99-0990-2 Laboratory TC/TOC Analyzer; For solids sample boats only; TRL-TOC-AS-S
Includes autosampler; not included: IC function and liquid pump; upgradeable to universal configuration; includes: main unit and autosampler, USB cable to connect to PC, start-up kit including 25 g catalyst, 5 ea quartz sample boats; required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220VAC, 50 Hz operation; additional one set of consumables kit and more quartz sample boats are recommended for approximately one year operation
p/n: 99-0991-2 Laboratory TC+TOC+IC Analyzer; Universal; TRL-TOC-ASIncludes autosampler; universal configuration that handles both solid and liquid samples; TC-TOC-IC all included; includes: main unit and autosampler, USB cable to connect to PC, start-up kit including 25 g catalyst, 5 ea quartz sample boats and 5 ea 40mL vial ; required but not included items: PC, gas(either analytical grade air cylinder and pressure regular or air compressor) required; for 220VAC, 50 Hz operation; additional one set of consumables kit, more quartz sample boats and vials are recommended for approximately one year operation
AS CONFIGURATIONS-continued 1
p/n: 99-0992-2 Autosampler UpgradeFactory trained service person required for field upgrade; to convert TRL-TOC-AS-SS to TRL-TOC-AS-S
p/n: 99-0353-2 TN ModuleEasy to start up; includes: TRL-TN module with ozone generator and chemiluminescence detector, USB connection cable and power cable
p/n: 99-993-2 Universal UpgradeFactory trained service person required for field upgrade; to convert TRL-TOC-AS-S to TRL-TOC-AS
AS CONFIGURATIONS-continued 2
PERIPHERALS
p/n: 95-0653-1 PC min configuration: window 7, intel Core 3i, 1GB RAM, 100GB HDD, CD-ROM, 2xUSB port
p/n: 95-0654-1 Balance 0,01 mgr readability; 25 gr capacity; data transfer capabilityp/n: 95-0656-1 TOC Gas Generator Generates CO2 and hydrocarbon free air at steady 2 bars
pressure and continuous 3L/min flowrate, includes a noiseless and oil-free compressor
p/n: 95-0657-1 Communication Cable; PC to TRL-TOC USB to USP cable, 1mp/n: 95-0658-1 Flow Calibrator BIOS Model Defender 510, NIST traceable tested under
ISO17025 GLP; flow range: 50-5000mL/min; accuracy: 1% of full range
CONSUMABLES FOR TRL-TOC-SS
96-0449-1 Consumables kit for TC/TOC and TC/TOC+TN configurations
Includes: 1 btl (25gr) catalyst; 25 ea quartz sample boats; 1 ea dryer, permeation; 1 set of HT furnace inlet o-rings (set of 3); 1 set of HT furnace closure o-rings (set of 2)
96-0450-1 Consumables kit for IC configurations
Includes: 25 ea 40 mL sample vial, 5 ea septa, 5 ea screw cap; 1 ea dryer, permeation; 1 ea IC needle
97-0659-1 Catalyst, 25 gr in colored bottle97-0141-1 Dryer, permeation01-0299-1 Pyrex liquid separator97-0272-1 Sampling nozzle, 1/25, standard97-0347-1 Quartz sample boat, for single shot loader car only, 12mL97-0171-1 IC sample vial, 40 mL, without septa and screw cap97-0172-1 A set of septa and screw cap for 40 mL IC sample vial
CONSUMABLES FOR TRL-TOC-AS
96-0994-1 Consumables kit for TRL-TOC-AS-SS configuration Includes: 1 btl (25gr) catalyst; 5 ea quartz sample boats; 1 ea
dryer, permeation; 1 set of HT furnace inlet o-rings (set of 3); 1 set of HT furnace closure o-rings (set of 2)
96-0995-1 Consumables kit for TRL-TOC-AS-S configurations Includes: 25 ea sample vial with septa and screw cap; 1 ea dryer,
permeation; 1 ea IC needle 97-0659-1 Catalyst, 25 gr in colored bottle97-0141-1 Dryer, permeation01-0299-1 Pyrex liquid separator97-0272-1 Sampling nozzle, 1/25, standard97-1015-1 Quartz sample boat, for autosampler, 12mL97-0171-1 Sample vial, 40 mL, without septa and screw cap97-0172-1 A set of septa and screw cap for 40 mL IC sample vial
PRICING
Net Transfer Price($) Distributor's Discount End User Price($)
1000 30% 1.429
500 20% 625
100 10% 111