17D5565-0105 No. Browne McGregor Architects Inc 520 Post Oak Blvd Ste 880 Houston TX 77027 TO: 02/08/2017 DATE: 07 41 00-Flat Seam Metal Wall and Roof Panels RE: Mark Smith ATTN: Shop Drawings Letter Prints Change Order Plans Samples Specifications / Product Data Other: Approval Your Use As Requested Review and Comment Attached Separate Cover Via: Approved as Submitted Approved as Noted Returned After Loan Resubmit Submit Returned Returned for Corrections Due Date: 02/15/2017 WE ARE SENDING: SUBMITTED FOR: SENT VIA: ACTION TAKEN: TRANSMITTAL Dominique Galardo Signed: PROJECT: RKMS El Paso #3 LLC-NEC Site-Shell 02/08/2017 Date 07 41 00-01A Code Flat Seam Metal Wall and Roof Panels - Product Data Description Architect Review Status JOB: 17D5565 CC: Item Submittal 07 41 00 Package 1 Rev. Copies Ph/Fax: NOTES: 5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO 80111-4710 303-571-5377 303-629-7467 (fax) SUBMITTED GH Phipps Construction Companies GH Phipps Construction Companies has reviewed and hereby submits the attached documents in accordance with the contract documents. Note to Subcontractor/Material Supplier: Subcontractor/Material Supplier remains responsible for confirmation and correlation of dimensions at the job site, fabrication process and construction techniques; coordination of the work with the work of other trades; and satisfactory performances of the work. Dominique Galardo 02/08/2017

Transcript of TO: RE: ATTN: JOB: WE ARE SENDING: SUBMITTED …pix.ghphipps.com/projects/2016/16.0628/ProjDocs/06 -...

17D5565-0105No.

Browne McGregor Architects Inc520 Post Oak Blvd Ste 880 Houston TX 77027

TO:

02/08/2017DATE:

07 41 00-Flat Seam Metal Walland Roof Panels

RE:

Mark SmithATTN:

Shop Drawings

Letter

Prints

Change Order

Plans

Samples

Specifications / Product Data

Other:

Approval

Your Use

As Requested

Review and Comment

Attached

Separate Cover Via:

Approved as Submitted

Approved as Noted

Returned After Loan

Resubmit

Submit

Returned

Returned for Corrections

Due Date: 02/15/2017

WE ARE SENDING: SUBMITTED FOR:

SENT VIA:

ACTION TAKEN:

TRANSMITTAL

Dominique GalardoSigned:

PROJECT: RKMS El Paso #3 LLC-NEC Site-Shell

02/08/2017

Date

07 41 00-01A

Code

Flat Seam Metal Wall and Roof Panels- Product Data

Description

Architect Review

Status

JOB: 17D5565

CC:

Item

Submittal 07 41 00

Package

1

Rev. Copies

Ph/Fax:

NOTES:

5995 Greenwood Plaza Blvd.Suite 100Greenwood Village, CO 80111-4710303-571-5377303-629-7467 (fax)

SUBMITTEDGH Phipps

Construction Companies

GH Phipps Construction Companies hasreviewed and hereby submits the attacheddocuments in accordance with the contractdocuments.

Note to Subcontractor/Material Supplier:Subcontractor/Material Supplier remainsresponsible for confirmation and correlationof dimensions at the job site, fabricationprocess and construction techniques;coordination of the work with the work ofother trades; and satisfactory performancesof the work.

Dominique Galardo02/08/2017

SUBMITTAL TRANSMITTAL

Alexander Gonzalez 915-244-4992 [email protected]

x

NEIGHBORS EMERGENCY CARE #3

7876 N. MESA ST. EL PASO TX 79932

RKMS EL PASO #3 LLC

5850 SAN FELIPE ST 490

GH PHIPPS

5995 GREENWOOD PLAZA BLVD

WALL PANELS

7 07 41 00

SAMPLE

SAMPLE

Kynar 500® or Hylar 5000TM Limited Warranty

rev.030810 - 20YR Kynar Warranty

BERRIDGE MANUFACTURING COMPANY | 6515 Fratt Road, San Antonio, TX 78218 | P: (210) 650-3050 | F: (210) 650-0379

MATERIAL DESCRIPTION:

SOLD TO:

JOB NAME:

OWNER:

INVOICE NUMBER(S):

EFFECTIVE DATE:

DATE OF ISSUE:

Berridge Manufacturing Company warrants that Kynar 500® or Hylar 5000TM 70% full-strength Fluoropolymer finish will perform for twenty (20) years from date of installation as an effective surfacing material within the scope of the conditions and limitations defined in this warranty document:

EFFECTIVE SURFACING MATERIAL IS DEFINED TO MEAN:1. Freedom from cracking, chipping or peeling due to the deterioration

of the finish for a period of twenty (20) years from date of purchase, exclusive of mechanical damage or other abnormal contingencies. (See Para 2).

2. Freedom from any color changes in excess of 5 NBS Units (Using the NBS unit of color notation as measured on the MEECO Colormaster: ASTM-D-2244) for a period of twenty (20) years from date of purchase.

3. Freedom from chalking in excess of Number 8 Rating (ASTM-D-659-80) for a period of twenty (20) years from date of installation.

TERMS AND CONDITIONS OF WARRANTY:1. Berridge shall not have any obligation under this Warranty until

all invoices for installation, supplies and services have been paid in full to Berridge and to the Roofer.

2. BERRIDGE HAS NO OBLIGATION NOR RESPONSIBILITY FOR DAMAGE TO FINISH OR MATERIALS CAUSED BY THE FOLLOWING CONDITIONS:A. Materials installed in corrosive or aggressive environments

including, but not limited to, areas subject to marine conditions, salt water, salt water spray, chemicals, or harmful gases with the exception of normal air pollution.

B. Acts of God, falling objects, fire or external forces.C. Abnormal or harmful gases, fumes or chemicals other than

general air pollution.D. Physical damage after installation, intentional or unintentional,

whether caused by abuse, misuse, negligence, vandalism, or excessive foot traffic on roof area.

E. Any act or acts which damages finish after installation of materials on project.

F. Physical damage caused during the forming process due to machinery or roll forming process used.

G Slopes of the roof or sections with a pitch of less than one in twenty-four or otherwise as to allow puddling or staining.

H. Deterioration of finish or materials due to improper storage prior to or during installation process.

I. Deterioration of the finish or substrate caused by standing water or condensation.

J. Discoloration or damage to panel finish caused by failure to remove factory-applied protective strippable plastic film.

3. CUSTOMER MUST NOTIFY BERRIDGE MANUFACTURING COMPANY IN WRITING WITHIN THIRTY (30) DAYS FROM DISCOVERY OF THE CONDITION WHICH IS THE BASIS OF ANY CLAIM AND ALLOW AN INSPECTION OF THE MATERIALS DURING NORMAL BUSINESS HOURS.

4. BERRIDGE MANUFACTURING COMPANY’S OBLIGATION WITH RESPECT TO THIS WARRANTY IS LIMITED AS FOLLOWS:A. In the event of a valid claim, Berridge Manufacturing Company

shall, at its option: a.) assume the reasonable costs to restore the finish on the materials; b.) furnish replacement materials; or c.) refund the original purchase price paid to Berridge for the materials less five percent (5%) for each year which has lapsed since the date of purchase of the materials.

B. Berridge Manufacturing Company’s maximum liability for any claim under this Limited Warranty will be the lesser of the three amounts calculated pursuant to a, b, or c of paragraph 4A above.

C. It will be at the sole discretion of Berridge Manufacturing Company to determine which action will be taken with respect to any claim under this Limited Warranty.

D. In no event shall Berridge Manufacturing Company’s liability exceed the lesser of the cost of replacing or restoring the defective panels.

E. The warranty on any repaired or replaced product shall be for the remainder of the warranty period applicable to the original purchase.

F. EXCEPT AS SET FORTH HEREIN, BERRIDGE MANUFACTURING COMPANY MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND HEREBY EXPRESSLY DENIES THE SAME.

5. This warranty is tendered for the sole benefit of the original owner of the project named herein and is not transferable or assignable.

6. Berridge’s only liability and responsibility is to the terms and conditions of this Warranty. This Warranty supersedes and is in lieu of any and all other warranties (whether express or implied) that are either in addition to or in conflict with the term(s) and condition(s) stated herein.

7. In the event a court of competent jurisdiction rules that any portion of this Limited Warranty is unenforceable, the remainder of this Limited Warranty shall be construed and enforced as if the stricken portion was not a part hereof originally.

Optional seam lock feature.

Vented FW-12 & FW-1025 Panels provide 7.79 square inches of Net Free Vent Area (NFVA) per lineal foot of panel. Note: Berridge Manufacturing Company does not recommend this product in applications subject to aggressive atmospheres, marine environments or high humidity due to the corrosive nature of these environments on raw edges of steel.

Berridge FW-1025 & FW-12 PanelWall, Liner or Soffit Panels. Versatile, maintenance-free, prefinished metal wall panels for open spans.

Berridge FW-12 is a multipurpose wall and soffit panel as shown above.

With a 12” coverage, Berridge FW-12 panel is ideal for large soffit and ceiling applications.

24GA, FW-12, RECOMMENDED DESIGN LOAD IN PSF, PANEL WT = 1.40 PSF

SPAN (FT)

POSITIVE WIND LOAD (PSF)1-SPAN 2-SPAN 3-SPAN

4’ 94 86 1005’ 48d 55 64

24GA, FW-12, RECOMMENDED DESIGN LOAD IN PSF, PANEL WT = 1.40 PSF

SPAN (FT)

NEGATIVE WIND LOAD (PSF) WITH OPTIONAL SEAM-LOCK

24-Gauge2’ 67.57

2.5’ 61.513’ 55.45

3.5’ 49.384’ 43.32

4.5’ 37.265’ 31.20

NOTES:1. 22-Gauge, FW-12 Negative Wind Load with Optional Seam-Lock is 83 PSF at 2’ span. 2. All loads meet L/240 Deflection Criteria. (d) Deflection governs allowables.3. Positive values based on 1996 edition of AISI and good engineering practices.4. Negative values based on ASTM E1592 load testing.

SPECIFICATIONS(Complete specifications available at www.berridge.com)

PRODUCT:Furnish and install Berridge [FW-1025] or [FW-12] wall and soffit system as manufactured by Berridge Manufacturing Company, San Antonio, Texas.MANUFACTURE:[FW-1025] or [FW-12] provides a [12”] or [10 ¼”] coverage and a panel depth of 1½”. Panels are available from the factory in continuous lengths to a maximum of 40’-0”. Panel is available with optional vee grooves spaced at [3.4”] or [4”] o.c., optional stucco embossing, optional striations, or optional vented profile for soffit applications. ENGINEERING:Acceptable installation design over engineered framing or solid structural sheathing. Approved underlayment to cover sheathing (run horizontally starting at the sill and run up the wall, review Berridge underlayment details for complete installation instructions). MATERIALS, FINISH INFORMATION & CONSTRUCTION DETAILS:Reference web site: www.berridge.com

Berridge Manufacturing Company6515 Fratt RoadSan Antonio, Texas 78218(800) 669-0009 • www.berridge.com

Berridge FW-1025 & FW-12 Panels can be vented for soffit applications.

NEW PRODUCT

Printed in the USA - January 2017- 500 K

• Available in 24 & 22 gauge steel or 0.032 & 0.040 aluminum• Concealed fasteners• Optional vee-grooves• Seam lock feature (optional)• Striated profile (optional) • Optional stucco embossed texture• Panel may be vented• Soffit and vertical wall applications• Open framing or solid sheathing• ASTM air & water resistance tested*• ASTM E-1592*• Florida Product Approval*• Miami-Dade Approved • Texas Department of Insurance Listed* Unless otherwise noted, all testing is for steel only. *Approved for steel and aluminum

1 ½”(38 mm)

10 ¼” Coverage (260 mm)

3.4” (86 mm)

1 ½”(38 mm)

12” Coverage (305 mm)

4” (102 mm)

Available without grooves.

Available with striations.

Available with vents.

ALEXANDER G
Rectangle
ALEXANDER G
Accepted
ALEXANDER G
Highlight

BERRIDGE MANUFACTURING COMPANYKYNAR 500® HYLAR 5000™ COLOR FINISHES

TEAL GREEN

BRISTOL BLUECOLONIAL RED

MATTE BLACK

EVERGREEN

ZINC GREY

BURGUNDY

CITYSCAPE

HEMLOCK GREEN

DEEP RED

HARTFORD GREEN CHARCOAL GREY

FOREST GREENPATINA GREEN

SHASTA WHITE

MEDIUM BRONZE

AWARD BLUE COPPER-COTETM

LEAD-COTETM PREWEATHERED GALVALUME®

ANTIQUE COPPER-COTE

CHAMPAGNE

ZINC- COTETM

NATURAL WHITE

All colors except Award Blue, Charcoal Grey, Dark Bronze, Evergreen, Hartford Green, Matte Black and Teal Green comply with LEED® v3 & Energy Star requirements for roof slopes greater than 2:12.

Natural White complies with LEED® v3 & Energy Star requirements for low slopes less than or equal to 2:12.

AGED BRONZE

PARCHMENT

DARK BRONZECOPPER BROWN TERRA-COTTA

ROYAL BLUE

ALMOND

PREMIUM COLORS

ACRYLIC-COATED GALVALUME®

Berridge premium colors require a nominal surcharge.

METALLIC COLORS

STANDARD COLORS

Berridge metallic colors are premium finishes which require a nominal surcharge.Due to limitations in the printing process, please request actual color chips for accurate color viewing.

Due to limitations in the printing process, please request actual color chips for accurate color viewing.

NATURAL METAL FINISH

Berridge Acrylic-Coated Galvalume® is a coated sheet product that combines the corrosion resistance of GALVALUME® steel sheet with a clear, organic resin applied to the top side and bottom side of GALVALUME® substrate.

(210) 650-3050www.berridge.com

Energy Star is only valid in the United States.

SIERRA TAN BUCKSKIN

ALEXANDER G
Rectangle
ALEXANDER G
Accepted

KYNAR 500® HYLAR 5000TM SPECIFICATIONS FOR GALVALUME® AND ALUMINUM* COIL COATING APPLICATIONS:

BMC HOUSTONBRANCH FACILITY1720 Maury St.Houston, TX 77026713-223-4971Fax 713-236-9422

BMC SAN ANTONIOCORPORATE HQ6515 Fratt Rd.San Antonio, TX 78218210-650-3050Fax 210-650-0379

BMC DENVERBRANCH FACILITY7505 E 41st AveDenver, CO 80216303-322-3703Fax 303-322-3810

BMC CHICAGOBRANCH FACILITY1175 Carolina Dr.W. Chicago, IL 60185630-231-7495Fax 630-231-7520

BMC ATLANTABRANCH FACILITY319 Lee Industrial Rd.Austell, GA 30168770-941-5141Fax 770-941-7344

BERRIDGE CALIFORNIA SALES CORPORATION**18732 Corby Ave.Artesia, CA 90701562-402-2081Fax: 562-865-7878

BMC DALLASBRANCH FACILITY2015 California CrossingDallas, TX 75220972-506-8496Fax 972-506-8478

BMC SEGUINMANUFACTURING2201 Rudeloff Rd.Seguin, TX 78155830-401-5200Fax 830-303-0530

TESTED PROPERTY TESTING METHOD KYNAR 500® or HYLAR 5000™

Colors Available --- See color chart on reverse side

Specular Gloss ASTM D-523 Low and medium gloss only

Color Uniformity ASTM D-2244 Color controlled both instrumentally and visually

Dry Film Thickness ASTM D-7091, ASTM D-1005, NCCA 11-13, 11-14, 11-15 Primer 0.20 ± 0.05 mil, Topcoat 0.75 ± 0.05 mil

Hardness ASTM D-3363, NCCA 11-12, Eagle Turquoise Pencils HB Minimum

Adhesion (X-Cut) ASTM D-3359 No adhesion loss

Adhesion (Crosshatch) ASTM D-3359 No adhesion loss

Direct Impact Flexibility ASTM D-2794, Gardner Impact Tester, 1/10” Distortion Excellent, no removal

Reverse Impact Flexibility NCCA Spec. 11, ASTM D-2794, Gardner Impact Tester, 5/8” ball Impact force in inch pounds equal to metal thickness Excellent, no cracking or loss of adhesion

Formability ASTM D-4145, 180º T-Bend on 1/8 Mandrel No cracks or loss of adhesion

Salt Spray Resistance ASTM B-117 Passes 2000 hrs on Galvalume®

Passes 4000 hrs on Aluminum

Humidity Resistance ASTM D-2247 Passes 2000 hrs on Galvalume®

Passes 4000 hrs on Aluminum

Acid Resistance ASTM D-1308, Proc. 3.1.110% Sulfuric Acid spot test, 24 hr exposure Excellent, no effect

Alkali Resistance ASTM D-1308, Proc. 5.210% Sodium Hydroxide, 24 hr exposure Excellent, no effect

Abrasion Coefficient ASTM D-968 100 liters/mil topcoat

Detergent Resistance ASTM D-2248, 72 hrs immersion in 3% solution at 100ºF Excellent, no effect

Resistance to Acid Pollutants ASTM D-1308 Proc. 3.1.124 hr exposure 10% HNO3 vapors Excellent, no effect

Weathering - Color Retention ASTM D-2244, 20 yrs, 45º South Florida Maximum 5 NBS units color change

Weathering - Chalk Resistance ASTM D-4214, 20 yrs, 45º South Florida Not worse than No. 8 rating

Erosion 20 yrs, 45º South Florida Maximum 15% loss

Notes:1. ASTM - American Society for Testing Materials2. NCCA - National Coil Coaters Association3. Galvalume® is 55% Aluminum-Zinc alloy coated sheet steel and is a registered trademark of BIEC International, Inc.

BERRIDGE MANUFACTURING COMPANYwww.berridge.com**Berridge California and Florida Sales Corporations are separate entities from Berridge Manufacturing Company Summer 2016 Berridge Color Chart - 10M Printed in the U.S.A.

*Limited Availability for Aluminum, Consult Berridge

BMC PHOENIXBRANCH FACILITY5717 W. Washington St.Phoenix, AZ 85043602-385-1237Fax 210-650-0379

BMC KANSAS CITYBRANCH FACILITY1235 Southwest Blvd.Kansas City, KS 66103913-227-0855Fax 210-650-0379

BMC OKLAHOMA CITYBRANCH FACILITY1400 Exchange AveOklahoma City, OK 73108405-248-7404Fax 210-650-0379

BERRIDGE FLORIDASALES CORPORATION**8802 Venture CoveTampa, FL 33637813-335-4505Fax: 210-650-0379

RE

VIS

ION

HIS

TO

RY

REV ECR NO. DATE RELEASED BY

MATERIAL FINISH

DRAWN BY

DATE

CHECK BY

DATE

TOLERANCES PART NAME

SHEETPART NUMBER REVISION

0

1½" SSQ FLUSH WALL/SOFFITPANEL

FWQ-150 1 1 OF

AJB

11/30/2012

JD

01/07/2013

0 N/A .XX = `.01

.XXX = `.005

FRACTION = `1/32"

ANGLE = `1/2~

12 TO 22" [304.8mm to 558.8mm] PANEL WIDTH

1 1/2 [38.1]"1 15/32 [37.3]"

7/32 [5.6]"

1 3/8 [34.9]"

ADJUSTABLE REVEAL0" TO 3" IN 1/2" INCREMENTS

[0mm TO 76.2mm IN 12.7mm INCREMENTS]

89.0°`.5° 89.0°`.5°

NOTES:1. MATERIAL USAGE: 5" [127 mm]2. WHEN USING PERFORATOR:

MAXIMUM NET FREE AREA = 3.08SQUARE INCHES PER 12 INCHESOF PERFORATION[1987sq. mm / 304.8 mm]

3. MAXIMUM OF TWO PERFORATIONSPER PANEL.

4. DUAL DIMENSIONS: Inch [mm]

OPTIONAL SEALANT LOCATION

29/32 [23.0]"17/32 [13.2]"

5/16 [8.3]"

24ga BRILLIANCE RED

OPTIONAL PENCIL BEAD STRIATION

ALEXANDER G
Highlight
ALEXANDER G
Highlight
ALEXANDER G
Highlight
ALEXANDER G
Highlight
ALEXANDER G
Accepted
ALEXANDER G
Accepted
ALEXANDER G
Accepted
ALEXANDER G
Highlight
ALEXANDER G
Stamp
ALEXANDER G
Highlight