TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset...

10
1 TLP Pro 525C Series • Setup Guide Overview The Extron TLP Pro 525C is a 5-inch Cable Cubby touchpanel. It has a flip-up, 800x480 (WVGA), LCD touchscreen with 24-bit color depth. The TLP Pro 525C NC is a streamlined model, with a set of features that adhere to government and military security protocols. These touchpanels are suitable for any AV application requiring a Cable Cubby touchpanel with a customizable interface. This guide provides instructions for experienced installers to mount and install these touchpanels. For more complete instructions, see the TLP Pro 525C and 725C Series User Guide at www.extron.com. Setup Checklist Get Ready Download and install the latest version of the following software: GUI Designer — For designing layouts for Extron TouchLink ® Pro touchpanels and third party touch interfaces. Global Configurator ® Professional and Global Configurator Plus — For setting up and configuring the control processor and touchpanel. Toolbelt — Provides device discovery, device information, firmware updates, and configuration of network settings, system utilities, and user management for TouchLink Pro devices. Global Scripter ® — Provides an integrated development environment for Extron control systems programming. NOTE: All four software programs are available from www.extron.com. Obtain the following network information from your network administrator: DHCP status — (on or off). If DHCP is off, you must also obtain: IP address Subnet mask Gateway User name — This can be either admin or user. Password — The factory configured passwords for all accounts on this device have been set to the device serial number. Passwords are case sensitive. NOTE: If the device is reset to default settings, the password will be the default password configuration. The default password is extron (for either admin or user). Make a note of the touchpanel MAC address. Make sure you are familiar with all the included parts and have all the necessary Tools Required for Installation (see page 4) for installing the cable cubby. Included Parts Check that all the following parts are included: 3/8” Hole Plug (4) 1/4” Hole Plug (1) #6-32 Screw (4) #6 Star Washer (4) TLP Pro 525C or TLP Pro 525C NC (1) 2-space MAAP Frame (1) TLP Pro 525C Connectivity Bracket (1) Short Clevis Pin (1) Cotter Pin (1) HDMI Lockit (1) Tie wrap (1) 5-cable Pass-through Plate (1) Figure 1. TLP Pro 525C Included Parts NOTE: Active or passive MAAPs must be purchased separately (see www.extron.com).

Transcript of TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset...

Page 1: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

1

TLP Pro 525C Series • Setup Guide

OverviewThe Extron TLP Pro 525C is a 5-inch Cable Cubby touchpanel. It has a flip-up, 800x480 (WVGA), LCD touchscreen with 24-bit color depth. The TLP Pro 525C NC is a streamlined model, with a set of features that adhere to government and military security protocols.These touchpanels are suitable for any AV application requiring a Cable Cubby touchpanel with a customizable interface.This guide provides instructions for experienced installers to mount and install these touchpanels. For more complete instructions, see the TLP Pro 525C and 725C Series User Guide at www.extron.com.

Setup Checklist

Get Ready � Download and install the latest version of the following software:

� GUI Designer — For designing layouts for Extron TouchLink® Pro touchpanels and third party touch interfaces.

� Global Configurator® Professional and Global Configurator Plus — For setting up and configuring the control processor and touchpanel.

� Toolbelt — Provides device discovery, device information, firmware updates, and configuration of network settings, system utilities, and user management for TouchLink Pro devices.

� Global Scripter® — Provides an integrated development environment for Extron control systems programming.

NOTE: All four software programs are available from www.extron.com.

� Obtain the following network information from your network administrator:

� DHCP status — (on or off). If DHCP is off, you must also obtain: � IP address � Subnet mask � Gateway

� User name — This can be either admin or user.

� Password — The factory configured passwords for all accounts on this device have been set to the device serial number. Passwords are case sensitive.

NOTE: If the device is reset to default settings, the password will be the default password configuration. The default password is extron (for either admin or user).

� Make a note of the touchpanel MAC address.

� Make sure you are familiar with all the included parts and have all the necessary Tools Required for Installation (see page 4) for installing the cable cubby.

Included PartsCheck that all the following parts are included:

3/8” Hole Plug (4)1/4” Hole Plug (1)

#6-32 Screw (4)#6 Star Washer (4)

TLP Pro 525C orTLP Pro 525C NC (1)

2-spaceMAAP Frame (1)

TLP Pro 525CConnectivityBracket (1)

Short Clevis Pin (1) Cotter Pin (1)

HDMI Lockit (1)Tie wrap (1)

5-cable Pass-throughPlate (1)

Figure 1. TLP Pro 525C Included Parts

NOTE: Active or passive MAAPs must be purchased separately (see www.extron.com).

Page 2: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

2

TLP Pro 525C Series • Setup Guide (Continued)

Mount and Cable All Devices

ATTENTION:• Do not power on the touchpanels until you have read the attention notification in the “Base Features” section of the

TLP Pro 525C and 725C Series User Guide.• Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde de la section « Base Features » du TLP Pro 525C and

725C Series User Guide.

� Cut a hole in the table (see Step 1 — Verify Cut-out Dimensions on page 4 and Step 2 — Cut the Surface on page 5).

� Run cables to the cable cubby (see Step 3 — Run all Cables on page 5).

� Install modules into the Cable Cubby enclosure. Multiple optional modules can be installed in the TLP Pro 525C Cable Cubby in a variety of configurations. Decide which modules and which configuration best serve your needs. Options include:

• Cable Retractors (see Step 4 — Install Cable Retractors (Optional) on page 5).• Pass-through Cable Modules (see Step 5 — Assemble the Pass-through Cable Module (Optional) on page 6).• AAP Modules (see Step 6 — Assemble the MAAP Module (Optional) on page 6).• Power Modules (see Step 7 — Install Modules on page 7).

� Use the setup menu for initial configuration of the touchpanel (see Setup Menu on page 10).

� Mount the units (see Step 8 — Mounting the Enclosure on page 9).

� Connect the touchpanel to a Power over Ethernet (PoE) injector (see figure 13 on page 10).

� Connect the power injector to the LAN and power it on (see figure 13).

Set up the Touchpanels for Network Communication � Connect the PC that you are using for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.

� Use the Setup Menu (see page 10) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway, and related settings for the touchpanel.

Configure the TouchpanelsThe GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a project and configuration.

Global Scripter provides an Extron-exclusive Python library (ControlScript®) and Global Scripter modules to get you started.

Page 3: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

3

Front Panel FeaturesA LCD screen — The TLP Pro 525C series has a 5-inch

touchscreen with a 800x480 resolution.

B Motion sensor — Detects motion between three to five feet from the touchpanel, and at least 15° from the center axis.

• When no motion has been detected for a user-defined period of time, the touchpanel enters sleep mode.

• When motion is detected by the sensor, the screen display is restored and active.

C Communication LED — This LED shows the configuration and connection status of the touchpanel:

• Unlit during normal operation (the touchpanel is configured and connected to an IP Link Pro control processor).

• Blinks red if the touchpanel has been configured but is not connected to an IP Link Pro control processor.

• Permanently lit if the touchpanel has not been configured and is not connected to an IP Link Pro control processor.

The indicator can be toggled between enabled and disabled, using the Setup Menu (see page 10).

D Light sensor — This sensor monitors ambient light level and adjusts screen brightness, based on the settings configured using the Setup Menu.

figure 2

AAA

BBBCCCDDDBBB

FFF

EEE

Figure 2. TLP Pro 525C Front Panel and Enclosure Features

Enclosure Features

E Activation switch – The left side of the lid hinge mechanism contains a switch. When the lid is closed, the switch sends the screen into sleep mode. When the lid is opened, the screen display is restored and active.

When the lid is shut, the screen is not activated by motion near the touchpanel.

F Speaker — A single speaker, located on the side of the enclosure, provides audible feedback for the user.

Base Panel FeaturesThese features are accessed from underneath the touchpanel.

A Menu button — Pressing the Menu button activates the setup menu (see Setup Menu).

B Reset button — Pressing the Reset button allows the unit to be reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10).

C Reset LED — Provides feedback about the reset status when the user presses the Reset button (see Reset Modes: a Brief Summary).

D USB port — Compatible with USB 2.0.

E LAN/PoE port — The TLP Pro 525C must be powered through this port (see Step 9 — Connecting the Power to the Touchpanel on page 10 for details).

figure 3

MENU RESET

USB

275 mA

LAN / PoE

DDD EEEAAABBBCCC

Figure 3. TLP Pro 525C Base Panel

ATTENTION:• Do not power on the touchpanel until you have read the attention notification in the “Base Features” section of the TLP Pro

525C and 725C Series User Guide.• Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde de la section « Base Features » du TLP Pro 525C and

725C Series User Guide.

NOTE: Once the enclosure is permanently mounted, the Menu and Reset buttons are under the table and may be difficult to access. Use the setup menu to configure the TLP Pro 525C before mounting the unit.

Page 4: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

4

TLP Pro 525C Series • Setup Guide (Continued)

Installation Overview

Tools Required for InstallationThe installer must provide the following tools, required for installation:

Safety Glasses Phillips Screw DriverTape Measure Marking Pen

Vacuum Cleaner

Figure 4. Tools Required for Installation

Planning � Before making any cuts, select the best location for the touchpanel.

� Ensure that the edge that opens on the lid is oriented correctly.

� Ensure there is enough space for all the system cables and components, including cable retractors, if they are to be installed. The space requirements for retractors are shown in the TLP Pro 525C and 725C Series User Guide, which is available at www.extron.com.

� Decide on the method for cutting a hole in the table:

• Hand router and template• CNC wood router• Jigsaw and paper template

� Verify that you have the correct template or dimensions.

� Check all relevant regulations.

� Ensure that the installation complies with local, state, and national building and electrical codes.

� Ensure that the installation complies with the Americans with Disabilities Act or other accessibility requirements.

Step 1 — Verify Cut-out Dimensions

ATTENTION:

• The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care to prevent scarring or damaging the furniture.

• L’ouverture dans la table pour le Cable Cubby doit être coupée uniquement par un ouvrier détenteur d’une licence. Veillez à ne pas laisser de marques ni à détériorer le mobilier.

• Use the appropriate metal Extron routing template or refer to the surface cutout dimensions before cutting a hole in the furniture or other surface. Pay special attention to the direction the unit will face. The connector access side is underlined (see Using a CNC wood router on the next page). Extron is not responsible for miscut mounting holes.

• Utilisez le gabarit de détourage métallique approprié ou reportez-vous aux dimensions de découpe de la surface indiquées ci-après avant de découper le meuble ou la surface. Faites particulièrement attention à la direction dans laquelle l’unité sera dirigée. Le côté pour accéder au connecteur est souligné. Extron décline toute responsabilité en cas d’erreurs de coupe.

• Ensure that the orientation of the Cable Cubby and the hole dimensions are correct before cutting the table.

• Assurez vous que la position du Cable Cubby et les dimensions du trou soient correctes avant de couper la table.

• Ensure the table surface is at least 0.375 inch (9.5 mm) thick.

• Assurez vous que la surface de la table est au moins 9,5 mm (0,375 pouce) d’épaisseur.

If using a hand router, you should purchase the appropriate Extron routing template (see “Installation Routing Templates for Cable Cubby Series/2 Enclosures” at www.extron.com).If using a CNC wood router, use the exact cut-out dimensions (see Using a CNC wood router on the next page).If using a reciprocating saw or jigsaw, use the paper cut-out template (available under the Downloads tab on the TLP Pro 525C product page at www.extron.com).

Page 5: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

5

Step 2 — Cut the Surface

CAUTION: Risk of personal injury: Wear safety glasses when operating power equipment.ATTENTION : Risque de dommages corporels: Portez des lunettes de sécurité lorsque vous utilisez l’équipement

électrique.

Be certain the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table” in the TLP Pro 525C and 725C Series User Guide). There are three methods for cutting the hole in the table:

USER ACCESS

EXTRON ELECTRONICS

TLP 710CV ROUTER GUIDE - ALL MODELS

STANDARD

0.625 IN OUTSIDE DIAMETER GUIDE BUSHING

0.500 IN CUT DIAMETER STRAIGHT ROUTER BIT

METRIC

16 MM OUTSIDE DIAMETER GUIDE BUSHING

12 MM OR 12.7 MM CUT DIAMETER STRAIGHT ROUTER BIT

ANDA

Figure 5. Using a Hand Router

Using a hand routerRecommended method — Use the appropriate Extron routing template (see “Installation Routing Templates” at www.extron.com). Refer to the Routing Template User Guide, available at www.extron.com, to prepare the template and use the template to cut the hole.

NOTE: The metal routing template must be purchased separately. It is reusable and should not be discarded when the installation is complete.

Using a CNC wood routerRecommended method — Use the exact cut-out dimensions:7.50 +0.00/-0.02 inches W x 6.00 +0.00/-0.02 inches D(191 +0.0/-0.1 mm W x 152 +0.00/-0.1 mm D)

NOTE: The underlined dimension is the connector or AAP access side for the unit.

Using a reciprocating saw or jigsawAcceptable method — Use the paper cut-out template (available under the Downloads tab on the TLP Pro 525C product page at www.extron.com).

Cut-Out Template for the Extron

TLP Pro 720C and TLP Pro 725C

1. Confirm the product to be installed.

2. Double-check the print settings,

before printing, and make sure

the page is not scaled.

3. Remove the surface cut-out area

(gray) from the template by cutting

along the red line.

DO NOT CUT the gray dotted lines.

4. Measure the cutout and template.

Make sure the dimensions are the

same as those shown.

5. Place the template and mark the

position on the mounting surface

where the RWM 2 is being installed.

6. Double check position and

dimensions, then cut the opening

in the wall.

68-2179-02 Rev. B

Trim Ring Outer Edge

(Do not cut this line.)

Page size: 11" x 17"

Print scale 1:1Do not shrink.

User Access

User Access

R = 0.25" (6.4 mm)

7.10" (180 mm)

8.90" (226 mm)

+ 0.00" (0.00 cm)

- 0.02" (0.05 cm)

SURFACE CUT-OUT AREA

Trim Ring LipWidth = 0.325" (8.3 mm)

Trim Ring O

Trim

r Edger Edger Edter EduterE

(Do not cut

(Do

his line.hisl hislithislithisl this

)

Figure 6. Using a Reciprocating Saw or JigsawStep 3 — Run all Cables

Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the cables below the table and through the hole that was cut in Step 2 — Cut the Surface (see above). Leave enough slack in the cables to connect or route them before the cubby is installed in the table. Leave enough space under the TLP Pro 525C enclosure for the external power supply and connection of AV cables and the network connection.

Step 4 — Install Cable Retractors (Optional)If required, Extron cable retractors must be purchased separately. It is difficult to mount the Cable Cubby into the table after the retractors have already been installed so Extron recommends installing the empty retractor bracket at this point. The bracket should be secured using the lowest level of mounting holes inside the touchpanel enclosure.A 525C module can accommodate two retractors. A triple-space module can accommodate three retractors.The retractors should be added to the bracket after Step 8 — Mounting the Enclosure on page 9. For complete information about retractors and how to install them, see the TLP Pro 525C and 725C Series User Guide and Retractors User Guide at www.extron.com.

Page 6: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

6

TLP Pro 525C Series • Setup Guide (Continued)

Step 5 — Assemble the Pass-through Cable Module (Optional)1. Insert the cable into the grommet plate (see figure 7, 1).

Step 6 — Assemble the MAAP Module (Optional)Figure 8 shows how to mount the double-space USB HUB4 MAAP. Mount two single-space MAAPs in a similar way.

NOTE: If required, MAAPs must be purchased separately. Go to www.extron.com to see the full range of products that are available.

1. Insert cables through the bottom of the connectivity module and connect them to the MAAP (figure 8, 1).

2. Secure two single-space or one double-space MAAPs in the provided MAAP frame, using the provided #4-40 screws (2).If you are using one single-space MAAP, fill the unused space with a blank MAAP plate.

3. Slot the two projections of the MAAP frame into the two outside holes at the top of the connectivity module (3).

4. Secure the MAAP frame to the connectivity module, using the screw (4) that is provided with the MAAP frame.

To secure the MAAP module to the touchpanel enclosure, see Step 7 — Install Modules.

e

21-918

12

3

Figure 7. Installing a Pass-through Cable Module for the TLP Pro 525C

2. Pass the cables through the connectivity module from the bottom.

3. Fill any unused holes with the provided plugs.4. Slot the four projections of the grommet plate into the four

holes at the bottom of the connectivity module (2).5. Secure the grommet plate to the connectivity module using

the screw (3) that is provided with the grommet plate.Figure 7 shows the grommet plate attached to the bottom of the connectivity module. To attach it to the top of the module, turn over the grommet plate and insert the two outer projections into the holes at the top of the module (see figure 8, below).To secure the pass-through cable module to the touchpanel enclosure, see Step 7 — Install Modules on page 7.

USB HUB4 MAAP

ACTIVITY

Mini Type BUSB

ExtronUSB HUB4 MAAPUSB Hub

(4) #4 - 40 Screws

111

222

333

444

Figure 8. Assemble the MAAP Module

Page 7: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

7

Step 7 — Install ModulesSeveral types of modules can be installed in the touchpanel Cable Cubby. In addition to retractors, MAAPs, and pass-through modules, power modules are also available. Power modules must be purchased separately. See the Extron website (www.extron.com) to select a power module that is suitable for your location.

ATTENTION:• For units that are used in North America, only use AC power modules that are UL Listed Model “Cable Cubby AC Power

Module”.• Pour les unités qui sont utilisées en Amérique du Nord, utilisez seulement les modules d’alimentation secteur qui sont

listés UL, modèle « Cable Cubby AC Power Module ».

• The unit is not UL Listed if it uses any AC power module other than Model “Cable Cubby AC Power Module”.• L’unité n’est pas certifiée UL si elle utilise tout autre module d’alimentation secteur autre que le modèle «Cable Cubby AC

Power Module ».

The holes to secure the 525C modules to the Cable Cubby are only in the longer sides of the module. Because of this, the modules can only be installed at the ends of the enclosure. The TLP Pro 525C can also accommodate Quad modules or the larger triple-space modules. The mounting holes for these modules allow them to be installed in the center of the enclosure.Extron recommends either of the possible configurations shown in figure 9, although several other configurations are possible.

e e

AC Power Module + 525C Module Cable Quad Brackets (2) + 525C Module

Figure 9. Recommended Module Configurations in the TLP Pro 525C

Installing a triple space moduleFigure 10 shows how to install a power module in the TLP Pro 525C. Quad modules and other three-space modules are installed in a similar way.If you are installing pass-through or AAP modules, the modules should be assembled in advance (see the TLP Pro 525C and 725C Series User Guide at www.extron.com).1. Slide the module into the enclosure from underneath (1).

Ensure the mounting holes on the module are aligned with the holes on the front of the enclosure.

2. Secure the module with the provided #6-32 screws and #6 star washers (2).

CAUTION: Risk of electric shock: To ensure proper electrical grounding, use the provided grounding screws and star washers.

ATTENTION : Risque de décharge électrique: Afin d’assurer une mise à la terre correcte, utilisez les fixations de mise à la terre et les rondelles en étoile fournies.

e

21-525-01LF

21-525-01LF

21-526-01LF

21-526-01LF

TOP

125V50-60Hz 12A MAX TOTAL

~

Slide the moduleinto the enclosureas shown(either side).

1

Secure the modulewith the includedscrews and washers.

2

Figure 10. Installing a Power Module in the TLP Pro 525C

Page 8: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

8

TLP Pro 525C Series • Setup Guide (Continued)

Installing a 525C moduleFigure 11 shows how to install a 525C module, with retractors, in the TLP Pro 525C enclosure.The 525C module accommodates up to two retractors.It is difficult to insert the Cable Cubby into the table once retractors are installed. Extron recommends installing the enclosure with a empty module. Once the enclosure is in position, the retractors can be added.525C Modules must be installed at the ends of the enclosure (see figure 11).1. Slide the module into the enclosure from underneath (1).

Ensure the mounting holes on the module are aligned with the holes on the sides of the enclosure.

NOTE: Multiple mounting holes in the enclosure allow the module to be mounted at several different levels. Ensure the module is low enough to avoid the cable connectors coming in contact with, and damaging the touchscreen.

2. Secure the module with the provided #6-32 screws and #6 star washers (2).

3. Mount the TLP Pro 525C into the table (see Step 8 — Mounting the Enclosure on page 9).

4. Insert the retractors into the module from underneath the table (3). Ensure the mounting slot in the retractors is aligned with the holes on the side of the module.

5. Secure the retractors with the included clevis pin (4).6. Secure the clevis pin with the cotter pin.7. Secure the locking screw on each retractor. Do not

overtighten the screw.

e

21-525-01LF

21-525-01LF

21-526-01LF

21-526-01LF

Insert Retractors into the bracket.

Slide the bracketinto the enclosureas shown(either side).

1

3

4

Secure the bracketwith the includedscrews and washers.

2

Secure the Retractorswith the includedmounting pin and clip

Secure the locking screw on each Retractor. Do not overtighten.

5

Figure 11. Installing a 525C Module in the TLP Pro 525C

Page 9: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

9

Step 8 — Mounting the Enclosure

NOTE: Once the enclosure is permanently mounted, the Menu button is under the table and may be difficult to access. Use the setup menu to configure the touchpanel before installing it (see Setup Menu on page 10).

1. Remove the edge grommet protecting the edges of the trim ring and the plastic film on the finished surfaces.

ATTENTION:• Do not use isopropyl alcohol or other solvents to clean the Cable Cubby. Strong solvents will ruin some finishes.

• Ne pas utiliser de l’alcool isoproprylique ou d’autres solvants pour nettoyer le Cable Cubby. Les solvants forts endommageront certaines finitions.

125V50-60Hz 12A MAX TOTAL

~

e

21-525-01LF

21-526-01LF

125V50-60Hz 12A MAX TOTAL

~

21-5

26-0

1

21-525-01LF

21-525-01LF

21-526-01LF

21-526-01LF

Rotate the side clamp outward and ensure that the lever is down.

Slide the clamp all the way up against the bottom of the table.

Ensure the Cable Cubby is �rmly seated in the table. Raise the lever to secure the Cable Cubby.

21 3

Lever

Figure 12. Mounting the TLP Pro 525C Enclosure

LockingPlate

NOTE: To lower the side clamp, turn the lever down, then press and hold the locking plate while sliding down the clamp.

2. Rotate the side clamps so that they are flush with the body of the enclosure.3. Carefully lower the enclosure into the hole cut in the table (see Step 2 — Cut the Surface on page 5). Ensure the trim ring

is flush with the top of the table.4. Once the enclosure is in position, rotate the side clamps outward (one on each side). Ensure the lever is pointing down (see

figure 12, 1).5. Slide the side clamps up until they are firmly against the bottom of the table (2).6. With the enclosure firmly seated, raise the levers to secure the TLP Pro 525C in place on both sides (3). 7. Use cable ties to secure cables under the table to prevent them becoming tangled.

Page 10: TLP Pro 525C Setup Guide · reset in any of three different modes (for an overview, see Reset Modes: a Brief Summary on page 10). C Reset LED — Provides feedback about the reset

10

For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website.For information about replacing and disposing of batteries, see the TLP Pro 525C and 725C Series User Guide at www.extron.com.

© 2019 - 2020 Extron Electronics — All rights reserved. www.extron.com All trademarks mentioned are the property of their respective owners.

Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876

TLP Pro 525C Series • Setup Guide (Continued)

Step 9 — Connecting the Power to the Touchpanel

The TLP Pro 525C is PoE compliant and must be powered through the LAN/PoE port (see figure 3, E, on page 3). Extron recommends the Extron XTP PI 100 power injector. Your power injector may look different.An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.

figure 13

100-240V ~ 50-60Hz0.4A MAX

XTP

PWR

XTP PWR

To network switch To touchpanel

111222

Figure 13. XTP PI 100 Power Injector

Reset Modes: a Brief SummaryThese touchpanels provide the following reset modes (see the TLP Pro 525C and 725C Series User Guide for complete information):

• Use Factory Firmware — With the unit powered off, press and hold the Reset button (see figure 3, B, on page 3) while reapplying power to the unit. Use this mode with Toolbelt software to replace firmware in the event of conflicts arising from uploading a firmware update.

• Reset All IP Settings — Press and hold the Reset button for 6 seconds. After the Reset LED (C) blinks twice, release and momentarily press the Reset button. Use this mode to reset all network settings without affecting user-loaded files.

• Reset to Factory Defaults — Press and hold the Reset button for 9 seconds. After the Reset LED blinks three times, release and momentarily press the Reset button. Use this mode to return the touchpanel to factory default settings.

NOTES:• The factory configured passwords for all accounts on this device have been set to the device serial number.

Passwords are case sensitive.• If the device is reset to default settings, the password will be the default password configuration. The default

password is extron (for either admin or user).

• Enable or Disable the DHCP Client — This mode toggles between DHCP enabled and DHCP disabled. Press the Reset button five times, consecutively. After the fifth press, do not press the button again within 3 seconds. If DHCP was enabled, it is now disabled and the Reset LED blinks three times. If DHCP was disabled, it is now enabled and the Reset LED blinks six times.

Setup Menu

NOTE: Once the enclosure is permanently mounted, the Menu and Reset buttons are under the table and may be difficult to access. Use the setup menu to configure the TLP Pro 525C before mounting the unit.

Press the Menu button (figure 3, A, on page 3) to

open the setup menu.Figure 14 shows the TLP Pro 525C Status screen.Select any of the five available screens (Status, Network, Display, Audio, and Advanced) by pressing the appropriate button in the navigation bar at the top of the screen (for more information, see the TLP Pro 525C and TLP Pro 725C Series User Guide).

Status Display Audio Advanced ExitNetwork

Info

Model: TLP Pro 525C

Part Number: 60-1560-02

FirmwareVersion: 1.02.0001-b001

Network

IP Address:DHCP:Host Name:

Off192.168.254.251

TLP-AB-CD-EF

Display

Resolution:GUI Project:Sleep Timer:

800x480N/A5 Minutes

Audio

Master Volume:Master Mute: Off

99

Advanced

Controller IP: N/AProject Size: N/A

BootloaderVersion: 1.03.0000

Figure 14. Setup Menu: Status Screen

ATTENTION:• Do not power on the touchpanel until you have read the Attention in the “Base

Features” section of the TLP Pro 525C and 725C Series User Guide.• Ne branchez pas l’écran tactile avant d’avoir lu la mise en garde dans la

section « Base Features » du TLP Pro TLP Pro 525C and 725C Series User Guide

1. Connect the touchpanel to a PoE power injector (not provided) using a twisted pair cable, terminated with an RJ-45 connector (see figure 13, 1).

2. Connect the power injector to the LAN through a network switch (2).

68-3319-51 Rev. B01 20