Tevatron Collider Status and Prospects

32
Tevatron Collider Status and Prospects Shameless outreach advertisement: Follow the Tevatron on Facebook and Twitter! Ron Moore Fermilab – AD / Tevatron Dept. APS DPF 2009 – Wayne State University

description

Tevatron Collider Status and Prospects. Ron Moore Fermilab – AD / Tevatron Dept. Shameless outreach advertisement: Follow the Tevatron on Facebook and Twitter!. Contents. Overview Luminosity Evolution Operational Considerations Prospects and Projections - PowerPoint PPT Presentation

Transcript of Tevatron Collider Status and Prospects

Page 1: Tevatron Collider Status and Prospects

Tevatron ColliderStatus and Prospects

Shameless outreach advertisement:

Follow the Tevatron on Facebook and Twitter!

Ron Moore

Fermilab – AD / Tevatron Dept.

APS DPF 2009 – Wayne State University

Page 2: Tevatron Collider Status and Prospects

Contents

• Overview

• Luminosity Evolution

• Operational Considerations

• Prospects and Projections

• References to other FNAL talks in the Accelerator sessions…– Vladimir Nagaslaev – Antiproton Production at Fermilab (Accelerator 3)

– Sasha Shemyakin – Antiproton Accumulation and Cooling at the Fermilab Recycler Ring (Accelerator 1)

– Phil Adamson – Fermilab Main Injector (Accelerator 3)

– Mary Convery – Optimization of Integrated Luminosity of the Fermilab Tevatron Collider (Accelerator 1)

APS DPF 2009 – Wayne State University

2R. Moore - FNAL

Page 3: Tevatron Collider Status and Prospects

Looking Down on the Fermilab Accelerator Complex

1 km

Main Injector

& Recycler

Tevatron

Pbar Debuncher & Accumulator

D0

CDF

Page 4: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 4

Tevatron Overview

• Synchrotron providing proton-pbar collisions @ 980 GeV beam energy

– Injection energy is 150 GeV

• Tevatron radius = 1 km revolution time ~ 21 s

• Virtually all of the Tevatron magnets are superconducting

– Cooled by liquid helium, operate at 4 K fun fact: ≈350 MJ stored energy!

• 36 bunches of proton and pbars circulate in single beampipe

– 3 trains of 12 bunches with 396 ns separation

– Electrostatic separators keep beams apart on helical orbits

• 8 Cu RF cavities to keep beam in bucket, provide acceleration

– 1113 RF buckets (53.1 MHz 18.8 ns bucket length)

• 2 low (small beam size) intersection points (CDF and D0)

Page 5: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 5

Tevatron

Tev dipole

Page 6: Tevatron Collider Status and Prospects

The Big Picture

APS DPF 2009 – Wayne State University

Record month Dec 2008 ≈ 250 pb-1

Record weekly delivered luminosity = 73.1 pb-1

6R. Moore - FNAL

Page 7: Tevatron Collider Status and Prospects

Record month Dec 2008 ≈ 250 pb-1

Record weekly delivered luminosity = 73.1 pb-1

The Logarithmic Big Picture

APS DPF 2009 – Wayne State University

7R. Moore - FNAL

Page 8: Tevatron Collider Status and Prospects

Tevatron Peak Luminosity

APS DPF 2009 – Wayne State University

each point is one store > 300 µb-1/s now routine

8R. Moore - FNAL

Page 9: Tevatron Collider Status and Prospects

Beam Intensities

APS DPF 2009 – Wayne State University

9R. Moore - FNAL

10000 109 278 109 / bunch 3000 109 83 109 / bunch

Page 10: Tevatron Collider Status and Prospects

Destroyed Collimators in Tevatron (2003)

APS DPF 2009 – Wayne State University

R. Moore - FNAL 10

Protons

prompted a faster quench protection system

tungsten

Stored beam energy

1013 protons @ 1 TeV ≈ 1.6 MJ

Damage done in ~10 ms

1.5 m long stainless steel

Page 11: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 11

Increasing Tevatron Luminosity

• Many gradual improvements

• Higher antiproton stacking rate → more antiprotons faster

• Recycler + Electron Cooling → more pbars with smaller emittances

• Smaller β* at CDF and D0 → smaller beam size (now down to ≈30μm)

• Improved beam lifetimes in Tevatron

– More separation between protons and antiprotons

• Better instrumentation, monitoring

• Better reliability, reproducibility

)()(2

**

z

ap

ap HNfN

L

• N = bunch intensities, f = collision frequency

• ε = transverse emittance (size), σz = bunch length

• H = “hour glass” factor (~0.6 for finite bunch length)

Page 12: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 12

Magnet Motion / Orbit Stabilization

V. Ranjbar

Orbit stabilization ON

E11 vert BPM [mm]

F17 horz BPM [mm]

D0 proton halo [Hz]

Proton vert tune

C4Q4 roll [μrad]

C4Q4 pitch [μrad]

Proton intensity [E9]

Store 4402

New BPM electronics help us see this motion!

Page 13: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 13

Strategy: Be Efficient, Be Consistent

• Big upgrades are done ⇒ Make the most of what we’ve got!

• Make HEP shot-setup more efficient– “One-shots” for Tevatron injection when needed – allows more pbar stacking cycles– Automation of tune, coupling, chromaticity measurements/settings– Working on faster proton injection → 2 bunches per shot instead of 1

• Increased/improved automation– Tune, coupling, chromaticity measurements/settings during shot-setup

– Orbit smooths during/between HEP stores• Reduce orbit drifts store-to-store, keeps optics consistent; sneak beam losses through IPs

– Faster scraping/halo removal– Beam-beam tune shift control

• Automated proton tune settings to account for varying pbar intensities shot-to-shot

• Monitor decrease in beam-beam tune shift during store, alert operators to nudge up

• Shorter HEP stores– Higher average pbar stacking rate → shorter stores for ≈ same initial lumi– More stores with higher average luminosity over store duration

Page 14: Tevatron Collider Status and Prospects

Stack, Stash, Store - Repeat

APS DPF 2009 – Wayne State University

our record week

Accumulator [1010]

Recycler [1010]

Tevatron Luminosity

[μb-1 / s]

Stack pbars in Accumulator shoot to Recycler stash

HEP stores

Shoot pbars from Recycler to Tev for HEP

14R. Moore - FNAL

Page 15: Tevatron Collider Status and Prospects

More Integrated Luminosity per Store

APS DPF 2009 – Wayne State University

- More integrated luminosity per store hour

- Running shorter stores ⇒ more stores / week

15R. Moore - FNAL

Page 16: Tevatron Collider Status and Prospects

Beam-Beam Effects

• Recall both beams circulate within a single beam pipe!– EM fields from one beam disrupts the other when passing

near/through it

• Head-on and long-range collisions (parasitic or “near-miss”) – Would like > 5σ separation between beams prior to collisions

• Not always possible

– Affects all aspects of operation – injection, acceleration, squeeze,…

• Highest antiproton intensities are problematic– Antiprotons 3-4x smaller transversely than protons

– High proton losses occasionally quench the Tevatron in squeeze

– Early in HEP proton lifetime can dominate lumi lifetime

– Occasionally back off beam intensities to sort out issues

APS DPF 2009 – Wayne State University

R. Moore - FNAL 16

Page 17: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 17

Head-On Beam-Beam Effects

• Head-on collisions: each beam acts as (non-linear) focusing lens

– Tune gets shifted up proportional to (N / beam size)

– Tune footprint also spreads out – unavoidably crossing resonances

– NP ≈ 250 (10)9 εP≈ 18π mm-mrad → ξA ≈ 0.020 (pbar shift from protons)

– NA ≈ 70 (10)9 εA≈ 5π mm-mrad → ξP ≈ 0.020 (proton shift from pbars)

– Beam-beam tune shift on protons ≈ pbars!

Nr

2

3 0• N = bunch intensity

• ε = transverse emittance

• r0 = classical radius of proton

Head-on beam-beam

tune shift parameter

2 collision

points

Page 18: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State UniversityR. Moore - FNAL 18

0 1 2 3

Beam-beam force Proton density Antiproton density

r/

Schematic of Beam-Beam Force on Proton Bunch

Round, gaussian bunchesproton pbar

x

y

A significant fraction of the proton bunches feel the strongest, non-linear beam-beam force from the smaller pbars

Arb

itrar

y un

its

Page 19: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 19

Beam-Beam Tune Shift Distributions

M. Syphers

Equal bunch sizes

Protonsbroad tune shift

Pbarspeaked

tune shiftσP = 2 σA

Δν / ξ

dN /

dR

for

a b

unch

Page 20: Tevatron Collider Status and Prospects

4/7 = 7th order

7/12 = 12th order

3/5 = 5th order

Beam-Beam Tune Spread

Tune spread caused by pbars causes

proton tunes to span strong resonances

→ higher beam loss and/or poorer lifetime

APS DPF 2009 – Wayne State University

20R. Moore - FNAL

This is just an “artist’s rendering” of the

beam-beam induced tune spread…

Page 21: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 21

Mitigating Beam-Beam Effects

• Since ~Feb 08 deliberately “blowing up” antiprotons by ≈25% at flattop

– Noise source on directional stripline

– Reduce the emittance mismatch → proton tune spread

– Helps beam losses in squeeze and in collisions

– Would like to optimize the scheme, account for bunch-by-bunch differences

• Also testing scraping higher intensity protons @ 8 GeV in Main Injector

– Bump beam into collimators, remove tails that would be lost in Tevatron

Page 22: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 22

Proton Loss in Squeeze vs Pbar Intensity

Long-range beam-beam effects: higher pbar intensity → higher proton loss

Page 23: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 23

Store 6908 – Comparison to Model without Beam-Beam Effects

Initial Lumi = 320 μb-1/s

only ~5% luminosity loss from beam-beam effects!

Protons suffer from beam-beam effects

Luminosity Integral Proton IntensityModelData

A. Valishev

Page 24: Tevatron Collider Status and Prospects

APS DPF 2009 – Wayne State University

R. Moore - FNAL 24

Beam Lifetimes during HEP• Pbar lifetime dominated by luminosity – good• Most protons lost in non-luminous processes – but better with larger pbar emittances

Luminosity[μb-1/s]

Pbar Lifetime

/ ExpectedLifetime from

Luminosity

Store 6203

Proton Lifetime

/ ExpectedLifetime from

Luminosity

1

0.75

0.5

0.25

0

300

225

150

75

0

Page 25: Tevatron Collider Status and Prospects

Reliability

APS DPF 2009 – Wayne State University

Year StoresNormal

Terminations%Normal

Terminations

Avg Store Hrs/Week (outside

of planned shutdowns)

2003 186 55 30% -

2004 166 110 66% 100

2005 243 170 69% 110

2006 171 107 63% 100

2007 220 177 80% 110

FY2008 304 262 86% 106

FY2009 275 244 88% 110

Improving

Reliability

25R. Moore - FNAL

Page 26: Tevatron Collider Status and Prospects

Prospects

• More pbars (faster) still most straightforward way to higher luminosity

• Believe Tevatron can deliver peak luminosity > 400 µb-1/s– As a stunt, since integrated lumi would fall off @ current stacking rates

• Squeeze losses still a concern, so still blow up pbars @ flat-top

– Identified aperture restriction on B-side of CDF (displaced beam pipe)

– During Oct 08 shutdown, found pipe misaligned as expected– Moved pipe successfully to open up aperture (though not quite

centered)

• All machines continue working on operational robustness, efficiency

• Quote from my boss (Roger Dixon) in Fermilab Today: – “…the Accelerator Division has no shortage of innovative people who get an

adrenalin rush from making unexpected improvements that could make our projections look silly.”

APS DPF 2009 – Wayne State University

26R. Moore - FNAL

Page 27: Tevatron Collider Status and Prospects

Luminosity Projections

• > 2.5 fb-1 / year is reasonable goal– No shutdowns, still need to be lucky

• 12 week shutdown began June 15– Install rest of new Booster correctors, poke holes in MI for NOνA– Find and fix known leaks in 8 of 24 Tevatron cryogenic houses

APS DPF 2009 – Wayne State University

27R. Moore - FNAL

• 200 pb-1 / month has become routine

Page 28: Tevatron Collider Status and Prospects

Luminosity Projection

APS DPF 2009 – Wayne State University

R. Moore - FNAL 28

currently 6.8 fb-1 delivered

real data for FY02-FY08

9.3 fb-1

7.8 fb-1

Inte

gra

ted

lu

min

osi

ty (

fb-1)

---------

FY04 FY05 FY06 FY07 FY08 FY09 FY10 FY11

~12 fb-1

have achieved design parameter goals of Run II

on track for ~12 fb-1 through FY11 even with no further

improvements

Page 29: Tevatron Collider Status and Prospects

Summary

• Tevatron and whole accelerator complex running great– delivered ≈ 3.5 fb-1 over last running period (Oct 07-Jun 09)

– now approaching 7 fb-1 total in Run 2

• Peak lumi > 300 µb-1/s and integrated > 200 pb-1/month routine

• Ongoing efforts to improve operational efficiencies and get more pbars/week and HEP stores with greater lumi/hr

• Could deliver > 9 fb-1 by end FY10 and nearly 12 fb-1 by end FY11– Let’s go all the way through FY11!

• Looking forward to physics results from both CDF and D0

APS DPF 2009 – Wayne State University

29R. Moore - FNAL

Page 30: Tevatron Collider Status and Prospects

Tevatron HEP Store Lengths

APS DPF 2009 – Wayne State University

30R. Moore - FNAL

Page 31: Tevatron Collider Status and Prospects

Collider Operational Model

APS DPF 2009 – Wayne State University

C. Gattuso

curr

ent r

egim

edepends on pbar stacking

rate and lumi lifetime

75 pb-1 ≈ consistent with our best week

Integrated luminosity optimized with 15-20 hr stores to build up stashes of 350-400 1010 pbars

at current stacking rates

31R. Moore - FNAL

Page 32: Tevatron Collider Status and Prospects

Making HEP Shot-Setup Faster

APS DPF 2009 – Wayne State University

- faster manipulations in Recycler- ongoing tweaking and automation in

Tevatron-recently started 2-bunch proton

injections- faster halo removal

32R. Moore - FNAL