• Fugitive Emissions & Why We Control Them

• What is Smart LDAR?

• The Smart LDAR Instrument

• Regulatory Issues with Smart LDAR

• Next Steps

Page 3: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

33

Fugitive EmissionsFugitive Emissions

• Routine leakage from valves, pumps, flanges, connectors, etc.

• Can aggregate to significant tonnage

• Can be hazardous air pollutants with direct health impact

• Can be controlled by equipment design or,more commonly, leak detection & repair programs

Page 4: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

44

Most current LDAR programsrequire visiting every component

regularly (e.g.. monthly).

Page 5: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

55

0102030405060708090

100

0-99ppm

500-999ppm

10,000-49,999ppm

>100,000ppm

%Total Count

% Total Emissions

Most equipmentdoesn’t

leak

84% of emissions come from

0.13% ofcomponents

Taback et al., 1997, API Publ 310, “Analysis of Refinery Screening Data”

Page 6: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

66

What Is What Is Smart LDARSmart LDAR??

• Smart Leak Detection And Repair is nothing more than the efficient locating and repair of the relatively small number of leaky valves, pumps, connectors, etc., in a large population of process equipment.

Page 7: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

77

Smart LDAR Conceptual Smart LDAR Conceptual FrameworkFramework

• Use remote sensing technology to quickly & economically identify significant leakers

• Scan often enough to catch significant leakers before emissions accumulate

• Repair (same as existing program)

Page 8: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

88

Smart LDAR Conceptual Smart LDAR Conceptual Framework (cont.)Framework (cont.)

• Tradeoffs include:– More frequent detection scans but fewer

repairs(don’t repair little leakers)

– More expensive equipment but less manpower for inspection and less repair cost (?)

Page 9: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

99

Smart LDAR InstrumentSmart LDAR Instrument

• API helping develop (with DOE & EPA)Backscatter Absorption Gas Imaging (BAGI) by LIS– BAGI scans laser over imaged area– Reflected laser captured by camera to form

image of area– Target gas absorbs laser and image appears

black

Page 10: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1010

Page 11: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1111

Page 12: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1212

Instrument DevelopmentInstrument Development

• Commercial product: – GasVue from Laser Imaging Systems

– Uses CO2 laser to see SF6

• Being adapted by Sandia National Labs– Changing to PPLN laser to look at H-C bond

stretch(periodically-polled Lithium Niobate)

– Making man-portable and intrinsically safe• Issues include laser power, battery life, weight

– Largely paid for by DOE & EPA

Page 13: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1313

Shoulder-mounted camera

Shoulder-mounted camera

Backpack power/control unit

Page 14: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1414

Page 15: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1515

Does Instrument Work?Does Instrument Work?

• 1998 petrochem plant test

• 1999 refinery test

• 2001 laboratory tests

• 2002 refinery test delayed due to instrument problems– Various glitches & gremlins in the system

• Fully expect to establish reliable field detection limit

Page 16: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1616

Smart LDAR Regulatory Smart LDAR Regulatory ProgressProgress

• 2000 report established “equivalence” criteria between Smart LDAR and Method 21– Required sophisticated Monte Carlo analysis – Determined relationship between frequency of

scan and required reliable detection limit

Page 17: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1717

Open Issues / Next StepsOpen Issues / Next Steps

• Reliability in field use

• Detection limit and subjectivity of interpretation

• Standardized Procedures &Recordkeeping

• Commercial availability of BAGI units

• Alternative technologies development

Page 18: Smart LDAR: October 30, 2002 Dave Markwordt, Bill Grimley, Tom Logan.

1818

SummarySummary

• Significant incentives exist to continue developing Smart LDAR technologies & regulations

• Laser BAGI technology poised to achieve field demonstration status for a man-portable unit

• All participants in this multi-stakeholder, multi-disciplinary effort are optimistic of a successful conclusion.