Single Pole (One Location) Wireless Occupancy Sensor...
Transcript of Single Pole (One Location) Wireless Occupancy Sensor...
Dip Switch Settings:NOTE: To access dip switch settings, lift up the bottom of the switch pad.
Single Pole Wiring Application: • WSS10ReceiverControlSwitchisonlyintendedasa
SinglePoledevice.Multiple Location Wiring Application: • WSS0SWirelessRemoteSwitchcanbeusedfor
additionalswitches(3-wayand4-way),nowiresnecessary.
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWERatcircuitbreakerorfuseandtestthatpowerisoffbeforewiring!
SinglePole(OneLocation)Wireless Occupancy Sensor Products
Cat.No.WSS10,WSC04,WSC15,andWSS0SIncandescent:800W@120V–Ballast:1200VA@120V,2700VA@277V
120-277VAC,50/60Hz,Motor:1/4HP@120VINSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:•Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.•Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.•WSS10-GDxproductsdonotrequireaneutralwire,thereisaminimumrequirementof25wattsfortheseproducts.
Tools needed DescriptionSlotted/PhillipsScrewdriver ElectricalTape PliersPencilCutters Ruler WireNuts
Push in side at tab to release
Line up tabs and press in side to attach
ColorchangeoptionsareavailablefromLeviton,consultyoulocalLevitonDistributor.Tochangecolorofframe,proceedasfollows:
Changing the color of your Switch
InstallationNOTE:UsecheckboxeswhenStepsarecompleted.√
Step 1
Step 3
Step 4
Step 2 Identifying your wiring application (most common):NOTE:Ifthewiringinyourwallboxdoesnotresemblethisconfiguration,consultanelectrician.
Single Pole1. Line2. Neutral3. Ground4. Load
2
4
3
1
WIRING SWITCH: Connect wires per WIRING DIAGRAM below as follows:• Connect(Hot)wirefromwallboxtoblackwireonswitch.• Connect(Load)wireinwallboxtobluewireonswitch.• Connect(Neutral)wireinwallboxtowhitewireonswitch. NOTE:ForNoNeutralmodel,whitewirewillnotbeavailable.
BK WH
2 Black wire (BK)
Blue wire (BL)
White wire (WH)
1
3
4
BK WH
BL
Switch
Black
White
Load
Neutral (White)
Line120-277VAC,
50/60 Hz
Hot (Black)
Auto ON / Auto Off mode:Automodecanbeenabledusingthedipswitches,productcomesfromthefactoryinManualOn/AutoOff.Walk-through:canbeusedonlyinAuto-ONmodeandisrecommendedonlywhenusingbatteriesorlowvoltagepowerconnection.Timeout:2(test),10,20,30min;(Longertimedelayisrecommendedforcontinuousselfpoweringofthesensorandtoensurepacketsaresenttothereceiverswitch).
DIP SWITCH SETTINGS
-
-X
3
34
12
4
34
34
Dip Switch
10 Min Time-Out
30 Min Time-Out
20 Min Time-Out
2 Min Time-Out
ON Position
ON Position
-ON Position
ON PositionX-
ON PositionXX
Manual ON/Auto OFFWalk Through ON
X
X-
OFF Position
OFF Position
OFF Position
XOFF Position
OFF Position
-X
--
Auto ON/Auto OFFWalk Through OFF
Dip switches 1-4
Cat.No.WSS10isthereceiverswitch.Thisswitchhasasingleswitchpadthattogglestherelayanditscorrespondingload,ONandOFF.IftherelayisOFF,therelaywillturnONwhenthepush-buttonispressed,andvice-versa.TheIndicatorLEDwillblinkRedwhenaflag/packetisreceivedfromthesensororremoteswitch.NOTE: the no-neutralversionhasaminimumloadrequirementof25watts.Cat.No.WSCxxisthesensor(s).TheSensorUnitsendsaflag/packetwiththepresenceofmotiontothereceiverswitchwhichthenkeepstheloadON.Intheabsenceofmotion,theSensorUnitwillstopsendingflag/packetstothereceiverswitch;whenthereceiverswitchnolongerreceivesapacket,theTimeOutwillstart,thentime-outandturntherelayOFF.TimeDelaystartsasofthelastmotiondetectedinthespace.TheMotionIndicatorLEDwillblinkRed(1blinkperminute)everytimemotionisdetected,sendingaflag/packettothereceiver.• WSCxx & WSS10 (together):InManual-ON/Auto-Offmode,the
buttonmustbepressedtoturnthelightsON.Intheabsenceofflags/packetssentfromthesensor,thereceiverswitchwillTime-OutandturnthelightsOFF.
• WSCxx & WSS10 (together):InAuto-ON/Auto-Offmode,thesensorwillsendaflag/packettothereceivertoturnthelightsON.Intheabsenceofflags/packetssentfromthesensor,thereceiverswitchwillTime-OutandturnthelightsOFF.NOTE:ThesensormustsensemotionandsendapackettostartthetimedelayandenableAuto-Off.
• WSCxx & WSS10 (together):Theyallowthe30secondvacancyconfirmationfeaturewhichexiststoturntherelaybackONincaseoffalseOFF.
Self Powered Products:ThesensorandremoteswitchareselfpowereddevicesusingEnOceantechnology.• TheSensorutilizesasolarpanelwhichpowersthesensorfromthe
roomsambientlight.Thesensorwillstarttofunctionwithinaminuteofexposuretolight.Thetotalchargetimeforthesensorwillvarydependingonintensityoflightandlengthofexposuretolight.Theminimumlightrequirementforthesensoris40LUX(4FC).
• Theremoteswitchutilizeskineticenergyfromthemechanicalswitchwhenpushingthepad.Thisfrictionthenstoresenoughenergytotransmitanothersignalonthenextpressactionofthepad,testedover50,000cycles.
Battery option:Theuseof(3)AAAbatteries(notincluded)isnotrequiredbutcanusedinareaswherenolightisexpectedforlongperiodsoftime.Low Voltage option:The5-24VDCconnection,isprovidedandrecommendedwhenusedinareaswherenolightisexpectedforlongperiodsoftime.
Factory settings:WSS10:ManualOn/AutoOff,Walkthru=disabled,Timedelay=10min.WSCxx:Range(PIRsensitivity)=75%Factory setting operation: Whenenteringtheroom,thewirelessreceivercontrolswitchwillneedtobemanuallyturnedON.Oncelearnedintothereceiverswitch,theWirelessoccupancysensorwillsendflag/packetstothereceiverswitch,keepingthelightsonuntiltheroomisvacant.Oncethesensorstopssendingflag/packets,thereceivertimeoutwillstart,thenturnthelightsOFFaftertimeoutperiod.Time-Outs:TheSensorhasfourtime-outsettings:2(test),10,20,or30min.(longertimeoutisrecommendedforselfpoweringindarkspaces).Thevaluesoftime-outisuserselectedthroughtheuseoftheDipSwitchSettings. NOTE:Sincethesensorisonlysendingapacketeveryminute,the2minutetimedelayisnotsufficientfornormaloperation.Walk-Through Time Delay: Thewalk-throughfeatureisonlyactiveintheAuto-On/Auto-Offmodewithtimedelayof10,20or30min,isusefulwhenaroomismomentarilyoccupied.Withthisfeature,theSensorwillturnthelightsOFFshortlyafterthepersonleavestheroom.Thewalk-throughfeatureworksinthefollowingmanner:Whenapersonenterstheroom,thelightswillturnON.Ifthepersonleavestheroombeforethewalk-throughtime-outof2.5minutes,theSensorwillturnthelightsOFFwithin2.5minutesofnooccupancydetected.Iftheroomisoccupiedforlongerthan2.5minutes,theSensorwillentertheOccupiedModewiththetime-outdurationspecifiedbytheDipSwitchsetting.
WARNINGS AND CAUTIONS:•Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingfixture.•Usethisdeviceonlywithcopperorcoppercladwire.•Recommendedminimumwallboxdepthis2-1/2”. PK-93664-10-00-0B
FCC COMPLIANCE STATEMENT Thisdevicecomplieswithpart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.AnychangesormodificationsnotexpresslyapprovedbyLevitoncouldvoidtheuser’sauthoritytooperatethisequipment.
LEARN MODE (to Learn devices):WhenusingtheWirelessOccupancyProductstogether,theymustbepairedtotheotherdevicestoperformasdesired.• WSC04 and WSC15-WirelessOccupancySensor(s)–haslearn
buttonondevice,underfrontplastictab• WSS10-WirelessReceiverControlSwitch-useswitchpadfor
learning• WSS0S-WirelessRemoteSwitch-useswitchpadforlearningSTEP A) Toenterprogramming,pressandholdtheReceiverControl
Switch(WSS10)switchpadfor15seconds.ThereceiverwillthenenterprogrammingandflashAMBER.
Thereare2modesinprogramming,LEARNandCLEARmodes. Tap the switch pad to toggle between the two programmingmodes
• 1AMBERLEDflash=LEARNmode • 2AMBERLEDflashes=CLEARmodeSTEP B)Selectthedesiredprogramming(LEARNorCLEAR)mode,
pressandholdthepadfor5secondstoENTERthedesiredmode (continue to step C or D).
STEP C)Pressthelearnbuttonsoneachofthedevicesyouwanttolearnintothereceiverswitch.
• Remoteswitch,youmustpresstheswitchpadtosendasignalforlearning.
• Occupancysensor,youmustpressthelearnbuttononthefrontofthesensorunderplastictabtosendasignalforlearning.
• AMBERLEDonfor2seconds=acknowledgement,deviceislearned.
NOTE:Pressthelearnbuttononcetolearn.Pressingitmorethanoncewillunlearnthedevice.
LED feedback/indicators in learn mode: • 1Redflash=nolearneddevices • 1Greenflash=1learneddevices • 2Greenflashes=2learneddevices • 3Greenflashes=3learneddevices • Etc.(upto6devices)To Un-Learn a single device:Presstheremoteswitchoroccupancysensorlearnbuttonagainandtheaddresswillberemoved. • GREENLEDonfor2seconds=deviceisunlearnedTo EXIT:(programming/learn/clear)Wait15secondsandthedevicewillautomaticallyexit.CLEAR MODE (to clear All Devices): • StartatthebeginningwithSTEPSAandBabove. • 1Redflash=nolearneddevices • MultipleGreenflashes=devicesexistSTEP D)Pressandholdtheswitchpadformorethan5seconds.After
thebuttonisreleased,theLEDwillflashredtoconfirmalllearneddeviceshavebeenclearedandthenthedevicewillexitprogramming.
NOTE: Productwillleavetheprogramminglearnorclearmodes,withoutchange,after15secondsofinactivity.
Restore Power:Restorepoweratcircuitbreakerorfuse. Installation is complete. ©2009LevitonMfgCo.,Inc. PK-93364-10-00-0B
CoveredbyoneormoreUS&ForeignPatentsandpatentspendingAllRightsIncludingTradeDressRightsReserved
For additional information, contact Leviton’s Techline at 1-800-959-6004 or visit Leviton’s website at www.leviton.com
LE
AR
N
RA
NG
E
WSC04/WSC15
WSS10
WSS0S
Push pad
Locator light
LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenefitofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforfiveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchfiveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melvile, New York 11747.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,but ifany impliedwarranty is requiredby theapplicable jurisdiction, thedurationofanysuch impliedwarranty, includingmerchantabilityandfitness foraparticularpurpose, is limited tofiveyears.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
Programming: Step 5
Step 8
• Positionallwirestoprovideroominoutletwallboxfordevice.
• Ensurethattheword“TOP”isfacingupondevicestrap.
• Partiallyscrewinmountingscrewsinwallboxmountingholes.
Testing your Switch prior to mounting in wall box:
NOTE:Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.
• Restorepoweratcircuitbreakerorfuse.
• PresspaduntillocatorlightisOFF.LightsshouldturnON.
If lights do not turn ON, refer to the TROUBLESHOOTING section.
Step 6
Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.
Switch Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 7
Troubleshooting• Lights Flickering - Lamphasabadconnection. - Wiresnotsecuredfirmlyunderterminalscrewsofswitch
and/orremote.• Light does not turn ON and Locator LED does not turn ON - Circuitbreakerorfusehastripped. - Lampisburnedout. - LampNeutralconnectionisnotwired.
OperationNOTE:ThelocatorlightwillilluminatewhentheloadisintheOFFpositiontofacilitateaccessinthedark.Charge time:2-4minutesdependingonstrengthoflightsourceOccupancy Sensor minimum light requirement:40LUXMin25W(Noneutralversion)Auto ON:willfunctionwith(3)AAAbatteriesindefinitelywhenambientlightispresentintheroomformorethan30minutesperday.Push Pad (Default settings)Turn ON from OFF position: Tap–LightsturnON.Turn OFF from ON position: Tap–LightsturnOFF.Cleaning:Cleanwithadampcloth.DO NOTusechemicalcleaners.