SIAF SIAFF industry and lighting SIAF/THT SIAF/GL-POL … · The data and sketches of this...

1
The data and sketches of this technical leaflet are not binding and can be varied as a consequence of modifications and/or improvements deemed necessary by the manufacturer. Tollerances on weights and diameters + _ 5% TECNO FUTURE ® CHARACTERISTICS CHARACTERISTICS 24 high temperature industry and lighting Section mm Max. diam. of strands mm Thickness of insulation mm Outer diameter mm Copper weight kg/Km Cable weight kg/Km TYPE B 1 0,21 2,5 6,3 9,6 54,8 Section mm Max. diam. of strands mm Thickness of insulation mm Thickness of outer sheath mm Outer diameter mm Copper weight kg/Km Cable weight kg/Km TYPE C1, C2 1 0,21 2,5 0,9 8,1 9,6 85,4 Operating temperature -60 ÷ +180 °C Rated voltage 500V Conductor bare, tin or nickel plated copper Insulation material silicone Also SIAF/VDE: VDE approved SIAF/THT: operating temperature -60 ÷ +250 °C SIAF/GL: fiberglass braid SIAF/POL: polyester braid SIAFF: extra flexible copper 0,05 / 0,07 / 0,10 / 0,15 mm dia. Avaiable in bare, tin or nickel plated copper SIAF Section mm 2 Max. diam. of strands mm Thickness of insulation mm Outer diameter mm Copper weight kg/km Cable weight kg/km Section mm Max. diam. of strands mm Thickness of insulation mm Outer diameter mm Copper weight kg/km Cable weight kg/km 0,25 0,21 0,6 1,8 2,4 6,1 25 0,41 1,4 10 240 326,7 0,35 0,21 0,6 1,9 3,2 6,8 35 0,41 1,4 11,2 336 438,8 0,5 0,21 0,6 2,1 4,8 9,6 50 0,41 1,6 13,3 480 624 0,75 0,21 0,6 2,4 7,2 13,3 70 0,51 1,6 15,4 672 860,2 1 0,21 0,6 2,5 9,6 15,9 95 0,51 1,8 17,8 912 1161 1,5 0,26 0,6 2,8 14,4 21,9 120 0,51 1,8 19,8 1152 1456,2 2,5 0,26 0,7 3,4 24 34,7 150 0,51 2 21,5 1440 1784,8 4 0,31 0,8 4,2 38,4 54,4 185 0,51 2,2 24,4 1776 2233,4 6 0,31 0,8 5,2 57,6 82,3 240 0,51 2,4 26,8 2304 2828,6 10 0,41 1 6,4 96 131,9 300 0,51 2,6 29,6 2880 3508,2 16 0,41 1,2 8 153,6 209,1 Conductor tin plated copper Insulation material silicone Operating temperature TYPE B: -60 ÷ +180 °C TYPE C1: -20 ÷ +90 °C TYPE C2: -20 ÷ +90 °C Rated voltage 10 Kv impulse Also TYPE C1: PVC outer sheat TYPE C2: halogen free compound outer sheat TYPE B TYPE C1 TYPE C2 TF_Catalogo.indd 24 29-07-2008 13:53:31

Transcript of SIAF SIAFF industry and lighting SIAF/THT SIAF/GL-POL … · The data and sketches of this...

The data and sketches of this technical leaflet are not binding and can be varied as a consequence of modificationsand/or improvements deemed necessary by the manufacturer. Tollerances on weights and diameters +_ 5%TECNOFUTURE®

CHARACTERISTICS

CHARACTERISTICS

24

hig

h t

em

pera

ture

• i

nd

ust

ry a

nd

lig

hti

ng

Sectionmm

Max. diam.of strands

mm

Thicknessof insulation

mm

Outerdiameter

mm

Copperweightkg/Km

Cableweightkg/Km

TYPE

B

1 0,21 2,5 6,3 9,6 54,8

Sectionmm

Max. diam.of strands

mm

Thicknessof insulation

mm

Thickness ofouter sheath

mm

Outerdiameter

mm

Copperweightkg/Km

Cableweightkg/Km

TYPE

C1,

C2

1 0,21 2,5 0,9 8,1 9,6 85,4

Operating temperature -60 ÷ +180°C

Rated voltage 500V

Conductor bare, tin or nickel plated copper

Insulation material silicone

Also SIAF/VDE: VDE approved SIAF/THT: operating temperature -60 ÷ +250°C SIAF/GL: fiberglass braid SIAF/POL: polyester braid SIAFF: extra flexible copper 0,05 / 0,07 / 0,10 / 0,15 mm dia. Avaiable in bare, tin or nickel plated copper

SIAF SIAFFSIAF/THT SIAF/GL-POL

SIAF

Sectionmm2

Max. diam.of strands

mm

Thicknessof insulation

mm

Outerdiameter

mm

Copperweightkg/km

Cableweightkg/km

Sectionmm

Max. diam.of strands

mm

Thicknessof insulation

mm

Outerdiameter

mm

Copperweightkg/km

Cableweightkg/km

0,25 0,21 0,6 1,8 2,4 6,1 25 0,41 1,4 10 240 326,7

0,35 0,21 0,6 1,9 3,2 6,8 35 0,41 1,4 11,2 336 438,8

0,5 0,21 0,6 2,1 4,8 9,6 50 0,41 1,6 13,3 480 624

0,75 0,21 0,6 2,4 7,2 13,3 70 0,51 1,6 15,4 672 860,2

1 0,21 0,6 2,5 9,6 15,9 95 0,51 1,8 17,8 912 1161

1,5 0,26 0,6 2,8 14,4 21,9 120 0,51 1,8 19,8 1152 1456,2

2,5 0,26 0,7 3,4 24 34,7 150 0,51 2 21,5 1440 1784,8

4 0,31 0,8 4,2 38,4 54,4 185 0,51 2,2 24,4 1776 2233,4

6 0,31 0,8 5,2 57,6 82,3 240 0,51 2,4 26,8 2304 2828,6

10 0,41 1 6,4 96 131,9 300 0,51 2,6 29,6 2880 3508,2

16 0,41 1,2 8 153,6 209,1

Conductor tin plated copper

Insulation material silicone

Operating temperature TYPE B: -60 ÷ +180°C TYPE C1: -20 ÷ +90°C TYPE C2: -20 ÷ +90°C

Rated voltage 10 Kv impulse

Also TYPE C1: PVC outer sheat TYPE C2: halogen free compound outer sheat

SIAF/HT - EN 50143TYPE B

TYPE C1

TYPE C2

TF_Catalogo.indd 24 29-07-2008 13:53:31