SHEAR TEST.pdf

3
OIS pIc were supplied with a low alloy test ring, internallyclad with Inconeland were requested to perform shear tests in accordance with ASTM A264-94a. Theresults were asfollows: Width of Test 1 2 3 Shear Stress (MPa) Width of Cladding (W) Load (kN) 71.80 82.23 87.24 598 595 626 4.64mrn 5.52mrn 5.57mrn 25.85mm 25.03mm 25.01mm

Transcript of SHEAR TEST.pdf

Page 1: SHEAR TEST.pdf

OIS pIc were supplied with a low alloy test ring, internally clad with Inconel and were requested toperform shear tests in accordance with ASTM A264-94a. The results were as follows:

Width ofTest

123

ShearStress (MPa)Width of Cladding (W) Load (kN)

71.8082.2387.24

598595626

4.64mrn5.52mrn5.57mrn

25.85mm25.03mm25.01mm

Page 2: SHEAR TEST.pdf

~

Page 3: SHEAR TEST.pdf