Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in...

52
Drive Technology \ Drive Automation \ System Integration \ Services Operating Instructions Safety-Related BST Brake Module for Control Cabinet Installation Edition 10/2011 19357214 / EN

Transcript of Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in...

Page 1: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

Drive Technology \ Drive Automation \ System Integration \ Services

Operating Instructions

Safety-Related BST Brake Modulefor Control Cabinet Installation

Edition 10/2011 19357214 / EN

Page 2: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

SEW-EURODRIVE—Driving the world

Page 3: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

Contents

Contents1 General Information ............................................................................................ 5

1.1 How to use this documentation................................................................... 51.2 Structure of the safety notes ....................................................................... 5

1.2.1 Meaning of the signal words ........................................................ 51.2.2 Structure of the section-related safety notes ............................... 51.2.3 Structure of the embedded safety notes...................................... 5

1.3 Right to claim under warranty ..................................................................... 61.4 Exclusion of liability..................................................................................... 61.5 Copyright..................................................................................................... 61.6 Product names and trademarks.................................................................. 61.7 Applicable documentation........................................................................... 6

2 Safety Notes ........................................................................................................ 72.1 Preliminary information ............................................................................... 72.2 General information .................................................................................... 72.3 Target group ............................................................................................... 82.4 Designated use ........................................................................................... 82.5 Transport..................................................................................................... 82.6 Installation/assembly................................................................................... 82.7 Startup/operation ........................................................................................ 92.8 Inspection/maintenance .............................................................................. 92.9 Disposal ...................................................................................................... 9

3 Integrated Safety Technology.......................................................................... 103.1 Safe condition ........................................................................................... 103.2 Safety concept .......................................................................................... 10

3.2.1 Block diagram BST.................................................................... 113.3 Safety function .......................................................................................... 113.4 Restrictions ............................................................................................... 12

4 Safety-Relevant Conditions ............................................................................. 134.1 Permitted unit combinations...................................................................... 134.2 Requirements on the installation............................................................... 144.3 Requirements on external safety controller .............................................. 16

4.3.1 Sample circuit for a "safety switching device"............................ 174.4 Requirements on startup........................................................................... 174.5 Requirements on the operation................................................................. 18

5 Unit Design ........................................................................................................ 195.1 Nameplate, type designation .................................................................... 19

5.1.1 Example: Type designation ....................................................... 195.1.2 Example: Nameplate ................................................................. 19

5.2 Scope of delivery of BST .......................................................................... 205.3 Safety-related BST brake module............................................................. 205.4 Terminal assignment................................................................................. 20

Operating Instructions – Safety-Related BST Brake Module

3
Page 4: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

4

Contents

6 Installation ......................................................................................................... 216.1 Mechanical Installation.............................................................................. 21

6.1.1 Support rail mounting................................................................. 216.2 Electrical Installation ................................................................................. 23

6.2.1 Information on electrical installation........................................... 236.2.2 Double-pole safe disconnection................................................. 246.2.3 Single-pole safe disconnection .................................................. 25

7 Startup................................................................................................................ 267.1 Operating states........................................................................................ 26

7.1.1 Brake module control under normal operating conditions, e.g. automatic operation of the plant ................................................ 26

7.1.2 Brake module control under special operating conditions, e.g. teach or jog mode...................................................................... 27

7.1.3 Operating state display .............................................................. 27

8 Inspection/Maintenance ................................................................................... 288.1 Inspection and maintenance intervals....................................................... 288.2 Checking the brake function ..................................................................... 288.3 Service ...................................................................................................... 298.4 Unit replacement....................................................................................... 29

9 Applications....................................................................................................... 309.1 Disconnection of single drives via inverter (example MOVIDRIVE® B) .... 319.2 Disconnection of single drives via inverter and DFS11B/21B fieldbus

interface .................................................................................................... 329.3 Disconnection of group drives................................................................... 33

10 Technical Data................................................................................................... 3410.1 General technical data .............................................................................. 3410.2 Safety-related control voltage ................................................................... 3510.3 Safety characteristics of BST brake modules ........................................... 3510.4 Dimension drawing of BST in control cabinet design................................ 36

11 Address List ...................................................................................................... 37

Index................................................................................................................... 48

Operating Instructions – Safety-Related

BST Brake Module
Page 5: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

1How to use this documentationGeneral Information

Safety-Rated BST Brake Module 1 General Information1.1 How to use this documentation

The documentation is part of the product and contains important information. Thedocumentation is for everyone who works with this product.

The documentation must be accessible and legible. Make sure that persons responsiblefor the system and its operation, as well as persons who work independently with thesoftware and the connected units from SEW-EURODRIVE, have read through the doc-umentation carefully and understood it. If you are unclear about any of the informationin this documentation, or if you require further information, contact SEW-EURODRIVE.

1.2 Structure of the safety notes1.2.1 Meaning of the signal words

The following table shows the grading and meaning of the signal words for safety notes,notes on potential risks of damage to property, and other notes.

1.2.2 Structure of the section-related safety notesSection safety notes do not apply to a specific action, but to several actions pertainingto one subject. The used symbols indicate either a general or a specific hazard.

This is the formal structure of a section safety note:

1.2.3 Structure of the embedded safety notesEmbedded safety notes are directly integrated in the instructions just before the descrip-tion of the dangerous action.

This is the formal structure of an embedded safety note:

• SIGNAL WORD Nature and source of hazard.

Possible consequence(s) if disregarded.

– Measure(s) to prevent the danger.

Signal word Meaning Consequences if disregardedDANGER Imminent danger Severe or fatal injuries

WARNING Possible dangerous situation Severe or fatal injuries

CAUTION Possible dangerous situation Minor injuries

NOTICE Possible damage to property Damage to the drive system or its environment

INFORMATION Useful information or tip: Simpli-fies the handling of the drive system.

SIGNAL WORDType and source of danger.

Possible consequence(s) if disregarded.• Measure(s) to prevent the danger.

Operating Instructions – Safety-Related BST Brake Module

5
Page 6: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

6

1 ight to claim under warrantyeneral Information

1.3 Right to claim under warrantyA requirement of fault-free operation and fulfillment of any rights to claim under limitedwarranty is that you adhere to the information in the documentation at hand. Therefore,read the documentation before you start working with the software and the connectedunits from SEW-EURODRIVE.

Make sure that the documentation is available to persons responsible for the machineryand its operation as well as to persons who work independently on the devices. Alsoensure that the documentation is legible.

1.4 Exclusion of liabilityYou must adhere to this documentation and the documentation of the connecteddevices from SEW-EURODRIVE to ensure safe operation and to achieve the specifiedproduct characteristics and performance features.

SEW-EURODRIVE assumes no liability for injury to persons or damage to equipment orproperty resulting from non-observance of the documentation. In such cases, any liabil-ity for defects is excluded.

1.5 Copyright© 2011 – SEW-EURODRIVE. All rights reserved.

Unauthorized duplication, modification, distribution or any other use of the whole or anypart of this documentation is strictly prohibited.

1.6 Product names and trademarksAll brands and product names in this documentation are trademarks or registered trade-marks of their respective titleholders.

1.7 Applicable documentationObserve the following applicable documents:

• Certificates and characteristic safety values

Make sure you always use the latest documentation and software version.

Our documentation is available in various languages for download from the SEWhomepage (www.sew-eurodrive.com). If you are unclear about any of the information inthis documentation, or if you require further information, please contact SEW-EURODRIVE.

If required, you can order printed copies of the documentation from SEW-EURODRIVE.

RG

Operating Instructions – Safety-Related BST Brake Module

Page 7: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

2Preliminary informationSafety Notes

2 Safety NotesThe following basic safety notes must be read carefully to prevent injury to persons anddamage to property. The operator must ensure that the basic safety notes are read andadhered to. Make sure that persons responsible for the plant and its operation, as wellas persons who work independently on the unit, have read through the operating instruc-tions carefully and understood them. If you are unclear about any of the information inthis documentation, or if you require further information, please contact SEW-EURODRIVE.

2.1 Preliminary informationThis document contains safety-related conditions for the operation of the safety-relevantBST brake module with safe disconnection of the brake.

The classification to category 3 according to EN 954-1, or performance level d accordingto EN ISO 13849-1 applies to the control and not to the brake.

2.2 General informationNever install or start up damaged products. Submit a complaint to the shipping companyimmediately in the event of damage.

All work related to transportation, storage, setup/mounting, connection, startup, mainte-nance and repair may only be carried out by qualified personnel, in strict observance of:

• The relevant detailed operating instructions

• The warning and safety signs

• All other project planning documents, operating instructions and wiring diagramsrelated to the drive

• The specific regulations and requirements for the system

• The national/regional regulations governing safety and the prevention of accidents

The requirements for the safety switching device and the permitted circuit variants arespecified in detail in section "Requirements for external safety switching devices"(page 16) and must be strictly observed.

The system/machine manufacturer must perform a system/machine-specific riskassessment. This is to take into account the safety-relevant BST brake module as wellas the mechanical brake design.

Removing covers without authorization, improper use as well as incorrect installation oroperation may result in severe injuries to persons or damage to property.

Refer to the documentation for additional information.

Operating Instructions – Safety-Related BST Brake Module

7
Page 8: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

8

2 arget groupafety Notes

2.3 Target groupOnly qualified personnel is allowed to perform installation, startup, fault repair andservicing (observe IEC 60364 or CENELEC HD 384 or DIN VDE 0100 and IEC 60664or DIN VDE 0110 as well as national accident prevention guidelines).

Qualified electricians in the context of these basic safety notes are persons familiar withinstallation, assembly, startup and operation of the product who possess the requiredqualifications.

Any activities regarding transportation, storage, operation, and disposal must be carriedout by persons who have been instructed appropriately.

2.4 Designated useThe safety-relevant BST brake module is responsible for the power supply and controlof disk brakes from SEW-EURODRIVE. For the permitted combination of safety-relatedBST brake module and SEW disk brake, refer to the section "Permitted unit combina-tions" in the "Safety-Relevant Conditions" chapter. The safety-relevant BST brakemodule is intended for industrial systems and may only be used in accordance with theinformation provided in SEW-EURODRIVE's technical documentation and the informa-tion given on the nameplate.

2.5 TransportInspect the shipment for any damage that may have occurred in transit as soon as youreceive the delivery. Inform the shipping company immediately. It may be necessary topreclude startup.

2.6 Installation/assemblyObserve the notes in chapter "Mechanical Installation" (page 21).

TS

Operating Instructions – Safety-Related BST Brake Module

Page 9: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

2Startup/operationSafety Notes

2.7 Startup/operation• When the safety-related control voltage V24 V safe / functional control voltage V24 V in

is disconnected, the DC link voltage VDC link is still present at the brake module.

• The safety concept is only suitable for performing mechanical work on the system/machine components.

• All poles must be disconnected from the supply system when work is carried out onthe electrical section of the system. Dangerous voltages may still be present for upto 10 minutes after disconnection from the power supply system.

• You have to take into account that, in case of a fault, the application time of theconnected brake is longer, which means the drive might coast.

– For maximum brake application times, refer to chapter "Technical Data" of theoperating instructions for the BST and SEW disk brakes.

– Note: If coasting to a halt results in application-dependent hazards, take addi-tional protective measures (e.g. movable covers with closure), which cover thehazardeous area until persons are no longer in danger.

– The additional protective covers must be designed and integrated to meet therequirements stipulated in EN ISO 12100:2010 and the requirements determinedfor the machine based on the risk assessment.

– After activating the stop command, access to the machine must remain blockeduntil the drive has reached standstill, or the access time has to be determined toensure that an adequate safety distance is maintained.

• The states of LED V1 and LED V2 must not be regarded as safety-relevant. The factthat the LED V1 and LED V2 are no longer illuminated does not indicate that thesafety-relevant BST brake module is de-energized and the brake is applied. Even ifLED V1 and LED V2 are not illuminated, DC link voltage VDC link might be present atthe BST brake module.

• The safety-related BST brake module does not detect a mechanical fault (such asbrake lining wear) of the disk brakes of SEW-EURODRIVE.

2.8 Inspection/maintenanceObserve the notes in chapter "Inspection/Maintenance" (page 28).

2.9 DisposalDispose the BST in accordance with the material structure and the regulations in forcefor instance as:

• Iron

• Copper

• Aluminum

• Plastic

Operating Instructions – Safety-Related BST Brake Module

9
Page 10: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

10

3 afe conditiontegrated Safety Technology

3 Integrated Safety TechnologyThe safety technology of the safety-related BST brake module described in this docu-ment has been developed and tested in accordance with the following safety require-ments:

• Category 3 according to EN 954-1

• Performance level d according to EN ISO 13849-1

This was certified by TÜV Nord. A copy of the TÜV certificate can be obtained fromSEW-EURODRIVE.

3.1 Safe conditionSafety-relevant use of the BST brake module means the de-energized condition ofthe connected brake is defined as safe condition. This is the basis of the safetyconcept.

3.2 Safety concept• The safety-related BST brake module enables the connection of an external fail-safe

safety switching device/safety controller. The safety switching device disconnectsthe safe control voltage V24 V safe when a connected control device (e.g. emergencystop device) is activated.

• Disconnecting the safe control voltage V24 V safe means the connected brake isdisconnected from the power supply. The power supply required for releasing theconnected brake is interrupted safely.

• Instead of separating the brake control galvanically from the power supply usingcontactors or switches, the disconnection procedure described here prevents thepower semiconductors in the safety-related BST brake module from being activated,in this way ensuring safe disconnection. This means that all connected brakes arede-energized although the supply voltage is still present at the safety-related BSTbrake module.

SIn

Operating Instructions – Safety-Related BST Brake Module

Page 11: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

3Safety functionIntegrated Safety Technology

3.2.1 Block diagram BST

3.3 Safety functionThe following drive-related safety function can be used:

• SBC (Safe Brake Control according to IEC 61800-5-2)

The SBC function safely de-energizes the connected brake by disconnecting thesafety-related control voltage V24 V safe. The safety-related control voltage must bedisconnected using a suitable external safety switching device/safety controller.

9007201124185483

[1] DC link voltage input VDC link (terminal 1/2)[2] Brake output (terminals 13/14/15)[3] Functional control voltage input V24 V in (terminal 3/4)[4] Safety-related control voltage input V24 V safe (terminal 5/6)

34

56

13

14

15

1 2

[1]

[4]

[3]

[2]

INFORMATIONSafety-related brake control must be carried out using the safety-related controlvoltage V24 V safe (terminal 5/6) only.

Operating Instructions – Safety-Related BST Brake Module

11
Page 12: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

12

3 estrictionstegrated Safety Technology

3.4 Restrictions

WARNINGVoltage is still present at the DC link connection of the frequency inverter even whendisconnecting the safety-related control voltage V24 V safe / functional control voltageV24 V in.

Severe or fatal injuries from electric shock.• If work is carried out on the electrical section of the brake system, the supply

voltage must be disconnected using an external maintenance switch.

INFORMATION• The safety concept is only suitable for performing mechanical work on the system/

machine components.• A system/machine-specific risk assessment must be carried out by the system/

machine manufacturer and be observed when using the drive system with BST.

RIn

Operating Instructions – Safety-Related BST Brake Module

Page 13: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

4Permitted unit combinationsSafety-Relevant Conditions

4 Safety-Relevant ConditionsThe safety function of BST can only be used for safe operation of the system/machineif it is integrated correctly in an application-specific, higher-level safety function or safetysystem. It is essential that the system/machine manufacturer conducts a system/machine-specific risk assessment (e.g. according to EN ISO 12100) and validates therequired safety conditions and functions prior to startup. The system/machine manufac-turer and the operator are responsible for compliance of the system/machine withapplicable safety regulations.

The following requirements are mandatory when installing and operating the BST brakemodule in safety-related applications.

The conditions are divided into the following sections:

• Approved device combinations

• Installation requirements (page 14)

• Requirements for the external safety controller (page 16)

• Startup requirements (page 17)

• Operation requirements (page 18)

4.1 Permitted unit combinationsThe following BST unit types are permitted for safety-related applications:

Type designation Part number Approved SEW disk brakes

BST 0.6S-460V-00 0 829 971 4 All brake coils with a coil voltage of AC 460 V and a coil power ≤ 120 W.Several brake coils can be connected for redundant systems. In this case, the total power must not exceed 120 W.

BST 0.7S-400V-00 1 300 077 2 All brake coils with a coil voltage of AC 400 V and a coil power ≤ 120 W.Several brake coils can be connected for redundant systems. In this case, the total power must not exceed 120 W.

BST 1.2S-230V-00 1 300 133 7 All brake coils with a coil voltage of AC 230 V and a coil power ≤ 120 W.Several brake coils can be connected for redundant systems. In this case, the total power must not exceed 120 W.

Operating Instructions – Safety-Related BST Brake Module

13
Page 14: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

14

4 equirements on the installationafety-Relevant Conditions

Only SEW disk brakes may be connected to the BST module.

4.2 Requirements on the installationThe line between the safety switching device/safety controller and the safety-relatedBST brake module, terminal 5/6 (V24 V safe) is referred to as safety-related control line(for safe disconnection).

Observe the following requirements on the installation:

• Power lines and safety-related control lines have to be installed in separate cables.

• The total cable length between the safety switching device/safety controller and thesafety-related BST brake module is limited to a maximum length of 100 m for EMCreasons.

• The total cable length between the safety-related BST brake module and theconnected brake must not exceed 200 m.

• Wiring must comply with EN 60204-1.

• The installation space (control cabinet) must have at least degree of protection IP54.

• The safety-related control lines must be routed according to EMC guidelines and asfollows:

– Outside an electrical installation space: Shielded cables must be routed perma-nently (fixed) and protected against external damage, or other equivalentmeasures.

– Individual conductors can be routed inside an electrical installation space.Observe the respective regulations governing the application.

– It is essential that you apply the shielding at both ends on the housing.

• The safety-related control voltage V24 V safe may not be used for feedback.

Asynchronous motor type

Brake type1)

1) Brakes of the type BM or BM(G) 05 – 30 can be combined.

DR.71 DR.80 DR.90 DR.100 DR.112 DR.132 DR.160 DR.180 DR.200 DR.225

BE05 x x

BE1 x x x

BE2 x x x

BE5 x x x x

BE11 x x x

BE20 x x

BE30 x x x

BE32 x x x

Synchronous motor type

Brake type1)

1) Brakes of the type B can be combined.

CMP.71 CMP.80 CMP.100

BY2 x

BY4 x

BY8 x

RS

Operating Instructions – Safety-Related BST Brake Module

Page 15: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

4Requirements on the installationSafety-Relevant Conditions

• You have to make sure that there is no transient coupling to the safety-related controlvoltage V24 V safe.

• Observe the values specified for safety components when designing the safetycircuits.

• Use only voltage sources with safe disconnection (SELV/PELV) according toEN 60204-1 for any DC 24 V voltage supply (safety-related control voltage V24 V safeand functional control voltage V24 V in) of the safety-related BST brake module.

In case of a single fault, the voltage between the outputs or between any output andgrounded parts must not exceed DC 60 V.

• Do not interconnect brake cables of several brake control systems.

• For disconnection of group drives, observe the switching capacity of the safetyswitching device and the maximum permitted voltage drop on the safety-relatedcontrol voltage V24 V safe.

• Adhere to the technical data of the BST module and the brake.

• Adhere to the general installation regulations in the "Installation" chapter.

The following figure shows EMC compliant installation.

9007199397615115

Operating Instructions – Safety-Related BST Brake Module

15
Page 16: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

16

4 equirements on external safety controllerafety-Relevant Conditions

4.3 Requirements on external safety controllerA safety relay can be used as an alternative to a safety controller. The following require-ments apply analogously.

• The safety controller and all other safety-related subsystems must be approved forat least that safety class which is required in the overall system for the application-related safety function. The following table shows an example of the required safetyclass of the safety controller.

• The wiring of the safety controller must be suitable for the required safety class, (seemanufacturer documentation). The safety-related control voltage V24 V safe can besafely disconnected either at the positive, or the positive and negative pole. SEW-EURODRIVE recommends bipolar disconnection.

• The values specified for the safety controller must be strictly adhered to whendesigning the circuit.

• The switching capacity of the safety relays or the relay outputs of the safety controllermust correspond at least to the maximally permitted, limited output current of thesafety-relevant control voltage V24 V safe. Observe the manufacturer's instructionsconcerning the permitted contact loads and fusing that my be required for thesafety contacts. If there are no manufacturer's instructions for fusing, thecontacts must be protected with 0.6 times the nominal value of the maximumcontact rating specified by the manufacturer.

• To ensure protection against unintended restart in accordance with EN 1037, thesafety controllers must be designed and connected in such a way that resetting thecontrol device alone does not lead to a restart. A restart may only be carried out aftera manual reset of the safety circuit.

• The input of the safety-relevant control voltage V24 V safe of the safety-relevant BSTbrake module (terminal 5/6) is equipped with a serial polarity protection diode and abuffer capacitor with C = 6 μF. This must be considered as load when dimensioningthe switching output.

• When switching off the BST with tested safe outputs, the switch-off test pulses mustnot exceed 1 ms. The next pulse blanking cannot reoccur earlier than after 20 ms.

Application Safety controller requirements

Category 3 according to EN 954-1 Category 3 according to EN 954-1Performance level d according to EN ISO 13849-1SIL 2 according to EN 61508

Performance level d according to EN ISO 13849-1 Performance level d according to EN ISO 13849-1SIL 2 according to EN 61508

RS

Operating Instructions – Safety-Related BST Brake Module

Page 17: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

4Requirements on startupSafety-Relevant Conditions

4.3.1 Sample circuit for a "safety switching device"

The following figure shows the basic connection of an external safety switching device(according to the before mentioned requirements).

Observe the information in the respective manufacturer's data sheets for connection.

4.4 Requirements on startup• Startup must be documented and the functionality of the safety functions must be

demonstrated. Observe the limitations for the safety functions of the BST brakemodule in chapter "Restrictions" for the verification of the safety functions. Non-safety-relevant parts and components that affect the result of the verification test(e.g. brake rampe of a frequency inverter) must be deactivated, if necessary.

• For using the BST brake module in safety-relevant applications, it is essential thatyou perform and record startup checks for the disconnecting device and correctwiring.

• During the startup procedure/function test, the correct assignment of the respectivevoltage supply connection must be checked by means of a measurement.

– Safety-relevant control voltage V24 V safe: Terminal 5/6

– Functional control voltage V24 V in: Terminal 3/4

• The function check must be carried out separately for all potentials.

• Observe the notes in the "Startup" chapter.

Safety-related

control voltage V

of the safety switching device

Safety switching device

Fuses according to the

specifications of the

safety switching device

manufacturerDC 24 V

GND

DC 24 V voltage supply

Approved

emergency stop device

Reset button

24 V safe

9007199399082635

Operating Instructions – Safety-Related BST Brake Module

17
Page 18: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

18

4 equirements on the operationafety-Relevant Conditions

4.5 Requirements on the operation• Operation is only allowed within the limits specified in the data sheets. This applies

to both the external safety relay as well as the BST.

• You must check the safety functions on a regular basis to ensure proper functioning.The the test intervals should be specified in accordance with the risk assessment.

• Also observe the information in the "Inspection/Maintenance" chapter.

RS

Operating Instructions – Safety-Related BST Brake Module

Page 19: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

5Nameplate, type designationUnit Design

5 Unit Design5.1 Nameplate, type designation5.1.1 Example: Type designation

The following characteristic unit data can be read from the type designation:

5.1.2 Example: NameplateThe following figure shows a nameplate of BST 0.6S-460V-00:

BST 0.6 S - 460V - 00Version/type

Brakevoltage

460 V = AC 460 V (DC 190 V)400 V = AC 400 V (DC 167 V)230 V = AC 230 V (DC 96 V)

Design S = Control cabinet module

Nominal output current 0.6 = DC 0.6 A0.7 = DC 0.7 A1.2 = DC 1.2 A

Series

18014398652394507

[1] Output current (Ibrake warm) in warm condition[2] Functional control voltage (Vin) and safety-related control voltage (Vsafe)[3] DC link voltage (VDC link)[4] Type designation[5] Serial number[6] Part number[7] Nominal output current (IN) and brake voltage (VB)[8] Safety characteristics[9] Degree of protection (IP) and ambient temperature (T)

CE mark to state compliance with European guidelines, such as the Low Voltage Directive.

UL logo to confirm that the component is UL (Underwriters Laboratory) tested, also valid for CSA in conjunction with register number 2D06.

+ + +- - -U Uz PEB

rd wh bu

DBI24 DGND SVI24 S0V24

IN = 0.6A DC (UB=190V DC / 460V AC)

08299714.11110004642

350 . . . 750V DCTyp : BST 0.6S−460V −00Uz=

24V DC Usafe = 24V DCUin=

Ibreak warm= 0.5A DC

13 14 15 3 4 5 NC 6 1 NC 2

WHEN USED WITH LISTED DRIVE SERIES:

MOVIDRIVE MOVITRAC

EN ISO 13849-1 Kat. 3 / PL d

IP 20 T= -15 ... +60°C

MANUFACTURED BY SEW-EURODRIVE ML 0001

[1]

[2][3][4]

[6][5]

[9] [8]

[7]

USUS

LISTEDLISTED

®

Operating Instructions – Safety-Related BST Brake Module

19
Page 20: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

20

5 cope of delivery of BSTnit Design

5.2 Scope of delivery of BSTThe scope of delivery includes:

• 1 safety-related BST brake module with installed holding fixture for support railmounting

• 4 attached plug connectors for terminal connections

5.3 Safety-related BST brake moduleThe following figure shows the unit design of BST x.xS-xxxV-00:

5.4 Terminal assignment

9007199397613451

[1] LED V1 for indicating the operating state[2] LED V2 for indicating the operating state[3] Terminals 13/14/15: Brake connection[4] Terminals 3/4 : For connecting the functional control voltage V24 V in[5] Terminals 5/6 : For connecting the safety-related control voltage V24 V safe[6] Terminals 1/2 : DC link voltage connection VDC link[7] PE connection[8] Retaining plate / shield plate

13/14 /15 1/ NC /23/4 5/NC/6

[3] [4] [5] [6]

[8]

[7]

[1] [2]

Terminal Function

12

+UZ- UZ

DC link voltage input Vz

56

SVI24S0V24

Safety-related control voltage V24 V safe inputReference potential for safety-related control voltage V24 V safe

34

DBI24DGND

Functional control voltage input V24 V inReference potential for functional control voltage V24 V in

131415

RDWHBU

Brake output

� Protective grounding

SU

Operating Instructions – Safety-Related BST Brake Module

Page 21: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

6Mechanical InstallationInstallation

6 Installation6.1 Mechanical Installation6.1.1 Support rail mounting

The BST module is mounted onto a support rail in the control cabinet.

Mounting

1. The upper holding fixture of the BST [3] is spring-loaded. First, insert the BST intothe upper support rail edge [5] with the upper holding fixture only.

2. Next, press the BST downward towards the support rail until the notch [4] clicks intoplace on the lower support rail edge [6].

The spring at the upper holding fixture causes the lower support rail edge to bepressed into the notch so that the BST [1] is secured onto the support rail [2].

137090187

1887424139

[1] Safety-related BST brake module[2] Support rail[3] Upper holding fixture of the BST[4] Notch, lower holding fixture of the BST[5] Upper support rail edge[6] Lower support rail edge

[1]

[2]

[3]

[4]

[6]

[5]

Operating Instructions – Safety-Related BST Brake Module

21
Page 22: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

22

6 echanical Installationstallation

Removal 1. Press onto the BST from the top. This causes the lower support rail edge [6] to comeoff the notch [4]. At the same time, remove the BST from the lower holding fixture.

2. You can remove the BST from the support rail once the lower lock unfastens.

Minimum clearance and mounting position

• Leave 30 mm clearance at the top, 70 mm at the bottom and 15 mm at the sides foroptimum cooling. Make sure air circulation in the clearance is not impaired by cablesor other installation equipment.

• Ensure unobstructed cooling air supply and make sure that the units are notsubjected to heated air from nearby components.

• Install the units vertically only. Do not install the units horizontally, tilted or upsidedown.

All dimensions in mm (in).

18014398646570507

15 15

70

30(1

.18)

(2.7

6)

(0.59) (0.59)

MIn

Operating Instructions – Safety-Related BST Brake Module

Page 23: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

6Electrical InstallationInstallation

6.2 Electrical Installation

6.2.1 Information on electrical installationSupply cable (terminal 1/2)

The supply cable must meet the following conditions:

• The supply cables to the BST carry a high DC voltage (max. DC 970 V). The ratedvoltage of the cable must amount to at least V0/V = 300 V / 500 V (in accordance withDIN VDE 0298).

• The inverter supply system must have a grounded star point (TT/TN). The operationis not permitted for IT systems or systems grounded via an outer conductor.

• Cable cross section: 0.75 mm2 – 2.5 mm2 (AWG 19 – AWG 13)

• Max. cable length: 100 m (328 ft)

• When several BST are connected to one DC link, the input power of the inverter mustbe taken into account.

• All poles of the supply cable are protected with two corresponding DC fuses F1/F2(recommended 1000 V/4 A).

Functional control cable (terminal 3/4)

The functional control cable must meet the following conditions:

• Cable cross section of 0.5 mm2 – 1.5 mm2 (AWG 20 – AWG 16)

• Max. cable length: 100 m (328 ft)

Safety-related control cable (terminal 5/6)

The safety-related control cable must meet the following conditions:

• Cable cross section of 0.5 mm2 – 1.5 mm2 (AWG 20 – AWG 16)

• Max. cable length: 100 m (328 ft)

Brake cable (terminal 13/14/15)

• Cable cross section of 0.75 mm2 – 2.5 mm2 (AWG 19 – AWG 13)

• Max. cable length: 200 m (656 ft)

INFORMATION• The safety-related BST brake module cannot be operated with sine-shaped power

regeneration.• All poles must be disconnected from the supply system when work is carried out

on the electrical section of the system. Dangerous voltages may still be present forup to 10 minutes after disconnection from the power supply system.

INFORMATIONThe fuses may not be required in compliance with IEC 60364-4-43 ((VDE 100 part430) and EN 60204-1 if the supply cable to the BST is protected by the input fuselocated in front of the inverter, or if the following conditions are met:• The cable length to the BST must not exceed 3 m.• Do not lay cables in the vicinity of inflammable substances.• Reduce the risk of short cirucits to a minimum.• Use the greatest possible cable cross section.

Operating Instructions – Safety-Related BST Brake Module

23
Page 24: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

24

6 lectrical Installationstallation

6.2.2 Double-pole safe disconnection

The following figure shows the wiring inside the installation space:

The following figure shows the wiring outside the installation space:

9007199388524427

5

6

Installation space

BST

DC 24 V

Safety

switching device

SVI24

S0V24

N.C.

Safety-related

control voltage

V24V safe

5

6

Installation spaceInstallation space

BST

Outside

installation space

Safety-related

voltage supply

24 VN.C.

+U24V safe

-U24V safe

Safety

switching device

9007199388555019

EIn

Operating Instructions – Safety-Related BST Brake Module

Page 25: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

6Electrical InstallationInstallation

6.2.3 Single-pole safe disconnection

The following figure shows the wiring inside the installation space:

The following figure shows the wiring outside the installation space:

9007199388553355

5

6

Installation space

BST

DC 24 V N.C.

SVI24

S0V24

Safety switching

device

Safety-related

control voltage

V24V safe

5

N.C.

6

Installation space

BST

Outside install. space

SVI24

S0V24

Safety switching

device

DC 24 V

Installation space

Safety-related

control voltage

V24V safe

9007199388551691

INFORMATIONSafe single-pole disconnection is only permitted when short circuits in the safety-relevant control cable between safety relay and BST can be ruled out (fault eliminationaccording to EN ISO 13849-2).

SEW-EURODRIVE recommends bipolar disconnection.

Operating Instructions – Safety-Related BST Brake Module

25
Page 26: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

26

7 perating statestartup

7 Startup7.1 Operating states

• The brake is activated with the functional control voltage V24 V in when the DC linkvoltage VDC link and the safety-related control voltage V24 V safe are present.

V24 V in is present � Brake released.

V24 V in is not present � Brake applied.

• If the safety-related control voltage V24 V safe is disconnected, the brake is safely de-energized (SBC).

• If the DC link voltage VDC link is disconnected, the brake is de-energized.

The brake is released with high-sped excitation. Rapid brake application (DC and ACswitch-off) occurs when it is controlled using the V24 V in functional control voltage or theV24 V safe safety-related control voltage.

The response time for releasing and applying the brake results from the response timeof the BST tR ≤ 6 ms and the response or application time of the brake connected. Forinformation on response or application times, refer to the applicable operating instruc-tions for motors.

7.1.1 Brake module control under normal operating conditions, e.g. automatic operation of the plantWith a brake coil power of P ≥ 70 W, you must ensure a timeout of at least 1 second forbrake control.

INFORMATIONFast disconnection (cut-off in the DC circuit) of the brake by the BST module is not partof the safety function (SBC). The brake application time for cut-off in the AC circuitmust therefore be used.

NOTICEThe brake module might be damaged if required off periods are not adhered to.

Damage to the drive system.• Adhere to the required off periods for the brake module.

2950935051

toff

1s

toff

1s

toff

1s

toff

1s

tontontonton

t/s

Brake

control

signal

OS

00

I

Operating Instructions – Safety-Related BST Brake Module

Page 27: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

7Operating statesStartup

7.1.2 Brake module control under special operating conditions, e.g. teach or jog modeFor teach or jog mode, for example, timeouts shorter than 1 second are possible. After20 control pulses, a timeout of minimum 3 min is mandatory in this case.

7.1.3 Operating state displayLEDs V1 and V2 indicate the operating state of the control inputs.

• LED V1: State of the safety-relevant control voltage V24 V safe.

• LED V2: State of the brake when the DC link voltage VDC link is present.

2951034251t

toff min. 180 s

max. 20 pulsesBrake

control

signal

LED V1 LED V2 V24 V safe V24 V in Operating state

Off Off Off Off Brake de-energized

Off Off Off On Brake de-energized

Lights up orange Off On Off Brake de-energized

Lights up orange Lights up green On On Brake energized when VDC link is present

INFORMATION• The states of LED V1 and LED V2 must not be regarded as safety-relevant.• The fact that the LED V1 and LED V2 are no longer illuminated does not indicate

that the safety-relevant BST brake module is de-energized and the brake isapplied.

• Even if LED V1 and LED V2 are not illuminated, DC link voltage VDC link might bepresent at the BST brake module.

Operating Instructions – Safety-Related BST Brake Module

00

I

27

Page 28: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

28

8 spection and maintenance intervalsspection/Maintenance

8 Inspection/Maintenance

8.1 Inspection and maintenance intervalsThe required inspection/maintenance intervals must be calculated by the systemmanufacturer according to the specific project planning documents for individual appli-cations, in accordance with the regionally valid standards.

8.2 Checking the brake functionThe brake function must be checked according to the instructions of the systemmanufacturer after inspection/maintenance work.

WARNINGRisk of crushing if the hoist falls.

Severe or fatal injuries.• Secure or lower hoist drives (danger of falling)• Isolate the inverter, the motor and the brake from the power supply before starting

work, safeguarding them against accidental startup.• Only use genuine spare parts in accordance with the valid parts list.• Always install a new brake controller at the same time as replacing the brake coil.• Observe the notes in the operating instructions for AC motors and brakemotors.• Only qualified personnel may perform maintenance for the brake.

WARNINGThere may still be dangerous voltages inside the unit and at the terminal strips for upto 10 minutes after the BST has been disconnected from the power supply.

Severe or fatal injuries from electric shock.• Disconnect the BST from the power supply and ensure that the unit cannot be

switched on unintentionally.• Wait for 10 minutes before carrying out any maintenance or inspection work.• Prior to maintenance or inspection work, make sure that the BST is de-energized.

CAUTIONThe surface of the safety-related BST brake module can be very hot during operation.

Danger of burns.• Let the BST cool down before you start working on it.

InIn

Operating Instructions – Safety-Related BST Brake Module

Page 29: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

8ServiceInspection/Maintenance

8.3 ServiceHave the following information available when you require assistance from the SEW-EURODRIVE service:

• Nameplate data (complete)

• Type and extent of the problem

• Time the problem occurred and any accompanying circumstances

• Assumed cause

8.4 Unit replacementProceed as follows to replace a BST:

• Observe the notes regarding inspection/maintenance work for the BST.

• DANGER There may still be dangerous voltages inside the unit and at the terminalstrips for up to 10 minutes after the BST has been disconnected from the powersupply.

Severe or fatal injuries from electric shock.

– Disconnect the BST from the power supply and ensure that the unit cannot beswitched on unintentionally.

– Wait for 10 minutes before carrying out any maintenance or inspection work.

– Prior to maintenance or inspection work, make sure that the BST is de-energized.

• Compare the data on the nameplate of the BST to be replaced with the new one.

• Remove all connecting terminals.

• Disconnect the PE and the shield clamps.

• Push lightly on the opposite side of the connection terminals and remove the BSTfrom the support rail.

• Install the new BST on the support rail. Observe chapter "Mechanical Installation".

• Connect the PE and the shield.

• Connect all connection terminals.

Operating Instructions – Safety-Related BST Brake Module

29
Page 30: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

30

9 pplications

9 Applications

The following figures show the wiring diagrams for SBC with simultaneous STO(Safe Torque Off).

INFORMATION• For safe single- and double-pole disconnection, refer to chapter "Electrical Instal-

lation"• DC fuses F1/F2 are not required if the before mentioned requirements for the

supply cable are met.• Observe chapter "Electrical Installation".

A

Operating Instructions – Safety-Related BST Brake Module

Page 31: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

9Disconnection of single drives via inverter (example MOVIDRIVE® B)Applications

9.1 Disconnection of single drives via inverter (example MOVIDRIVE® B)

18014398643152907

X13:

X2

:

X4

:

MOVIDRIVE B

Safety-ratedbrake module - BST

®

654

Enable/stop

/Controller inhibit

Reference potential binary signals

87

WVUPE

Uz+

Uz-

1

4

7

DIØØ

DIØ3

X17:

DC+24 V input

Reference potential binary signals

DC+24 V output

Reference potential DC+24 V input

1

2

3

4

DGND

VO24

SOV24

SVI24

DCOM

DC link connection

DC link connection

2

1

Uz-

N.C.

Uz+

X10:Regerence potential binary signals

/Brake

2

3

DGND

DBØØ

6

5

S0V24

N.C.

SVI24

blue

white

red

4

3

DGND

DBI24

15

14

13

BU

WH

RD

M

B

Fe

ed

ba

ck

em

erg

en

cy s

top

Re

se

t

DC 24 V

StartStop

Emergency

stop

~

GND

=CPU

Higher-levelcontroller

DI DO

Safetyrelay

~

F1/F2

LED V2

LED V1

Reference potential V24 V safe

V24 V safe

Reference potential V24 V in

V24 V in

Operating Instructions – Safety-Related BST Brake Module

31
Page 32: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

32

9 isconnection of single drives via inverter and DFS11B/21B fieldbus inter-pplications

9.2 Disconnection of single drives via inverter and DFS11B/21B fieldbus interface

18014399290419595

X13:

X2

:

X4

:

MOVIDRIVE B®

654

/Controller inhibit

Reference potential for binary signals

87

WVUPE

Uz+

Uz-

1

7

DIØØ

X17:

DC+24 V input

Reference potential binary signals

DC+24 V output

Reference potential DC+24 V input

1

2

3

4

DGND

VO24

SOV24

SVI24

DCOM

X10:Reference potential binary signals

/Brake

2

3

DGND

DBØØ

X30:

X31:1

2

3

4

5

6 24V_PS

24V_LS

GND

GND

F_DO_P

F_DO_M

M

B

CPU

F_CPU

Higher-levelcontroller

DI

F_DI

DO

F_DO

PR

OF

IBU

S

PR

OF

INE

T

PR

OF

Isafe

DFS11B/21B

F1/F2

~

Safety-relatedbrake module - BST

DC link connection

DC link connection

2

1

Uz-

N.C.

Uz+

6

5

S0V24

N.C.

SVI24

blue

white

red

4

3

DGND

DBI24

15

14

13

BU

WH

RD

LED V2

LED V1

~

GND

=

DC 24 V

Reference potential V24 V safe

V24 V safe

Reference potential V24 V in

V24 V in

DA

Operating Instructions – Safety-Related BST Brake Module

Page 33: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

9Disconnection of group drivesApplications

9.3 Disconnection of group drives

18014398643154571

X13:

X2

:

X4

:

MOVIDRIVE B®

654

Enable/stop

/Controller inhibit

Reference potential binary signals

87

WVUPE

Uz+

Uz-

1

4

7

DIØØ

DIØ3

X17:

DC+24 V input

Reference potential binary signals

DC+24 V output

Reference potential DC+24 V input

1

2

3

4

DGND

VO24

SOV24

SVI24

DCOM

X10:Reference potential binary signals

/Brake

2

3

DGND

DBØØ

M

B

B

Fe

ed

ba

ck

em

erg

en

cy s

top

Re

se

t

DC 24 V

StartStop

Emergency

stop

~

GND

=

CPU

Higher-levelcontroller

DI DO

Safetyrelay

F1/F2

~M~

Safety-relatedbrake module - BST

DC link connection

DC link connection

2

1

Uz-

N.C.

Uz+

6

5

S0V24

N.C.

SVI24

blue

white

red

4

3

DGND

DBI24

15

14

13

BU

WH

RD

LED V2

LED V1

Reference potential V24 V safe

V24 V safe

Reference potential V24 V in

V24 V in

Operating Instructions – Safety-Related BST Brake Module

33
Page 34: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

34

10 eneral technical dataechnical Data

10 Technical Data10.1 General technical data

Brake module BST 1.2S-230V-00 BST 0.7S-400V-00 BST 0.6S-460V-00

Part number 1300 1337 1300 0772 0829 9714

Interference immunity According to EN 61800-3

Interference emission with EMC-compliant installation According to EN 61800-3

Degree of protection IP20

Installation On support rail in control cabinet(control cabinet must have have at least degree of protection IP54)

Ambient temperature TA −15 °C to +60 °C

Climate class EN 60721-3-3, class 3K3

DC link voltageTerminal 1/2

VZ DC 350 V – 750 V (briefly up to DC 970 V)(at PA ≥ 95 W at least DC 450 V)

Power consumptionTerminal 1/2

PE 150 W, depending on brake typeShort-term: max. 800 W / 200 ms

Functional control voltageTerminal 3/4

V24 V in Signal level according to DIN EN 61131-2 type 1 DC +15 V to +30 V (> 2mA) => 1 / contact closed

DC −3 V to +5 V (< 2 mA) => 0 / contact openYou must only use grounded voltage sources with safe disconnection (PELV) according to

EN 60204-1 for the control input at terminals 3 and 4.

Brake voltageTerminal 13/15

VB DC 96 V DC 167 V DC 190 V

AC brake coil voltage AC 230 V AC 400 V AC 460 V

Nominal output currentTerminal 13/15

IN DC 1.2 A DC 0.7 A DC 0.6 A

Output currentTerminal 13/15

Ibrake warm DC 1.0 A DC 0.6 A DC 0.5 A

With PA = 120 W, the nominal output current reduces in warm condition.

Acceleration currentTerminal 13/14

IB 4 – 8.5 times the holding current depending on the brake type

Max. output power Pout Pout ≤ 120 W

Brake outputTerminal 13/14/15

The figures relate to SEW standard brake coils (two-coil system)Holding coil: Terminal 13red / 15blue

Accelerator coil: Terminal 13red / 14whiteSeveral brake coils can be connected for redundant systems. The sum of the individual

power levels must not exceed the max. output power.

Disconnection Cut-off in the DC and AC circuits (rapid application of the brake)

Supply cableTerminal 1/2

VZ Rated cable voltage: min. V0 / V = 300 V / 500 V (to DIN VDE 0298)Cable cross section: 0.75 mm2 – 2.5 mm2 (AWG 19 – AWG 13)

Max. cable length: 100 m (328 ft)

Functional control cableTerminal 3/4

V24 V in Cable cross section: 0.5 mm2 – 1.5 mm2 (AWG 20 – AWG 16)Max. cable length: 100 m (328 ft)

Brake cableTerminal 13/14/15

Cable cross section of 0.75 mm2 – 2.5 mm2 (AWG 19 – AWG 13)Max. cable length: 200 m (656 ft) at min. 1.5 mm2 (AWG 16)

Power loss PV Max. 30 W

Storage temperature −20 °C to +70 °C (EN 60721-3-3, class 3K3)

Dimensions W × H × D 134 mm × 70 mm × 135 mm (5.28 in × 2.76 in × 5.31 in)

Weight About 0.79 kg (1.7 lb)

GT

Pi

fkVA

Hz

n

Operating Instructions – Safety-Related BST Brake Module

Page 35: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

10Safety-related control voltageTechnical Data

10.2 Safety-related control voltageThe following table shows the technical data for safety-related control voltage V24 V safeat terminals 5/6:

10.3 Safety characteristics of BST brake modules

Safety-related control voltage V24 V safe Min. Typical Max.

Input voltage rangeaccording to DIN EN 61131-2 DC 24 V

DC 20.4 V DC 24 V DC 28.8 V

Input current 50 mA

Input capacitance 4.7 μF 6 μF

Switch-on/switch-off threshold DC 10 V

Input voltage for OFF state(brake de-energized) DC 6 V

Duration from switching off the safety-related control voltage at BST until switching off the brake voltage VB plus the brake application time of the connected brake.1)

1) The brake application time for cut-off in the AC circuit must be used.

6 ms

Safety-related control cable

• Cable length 100 m (328 ft)

• Cable cross section 0.5 mm2 (AWG 20)

1.5 mm2 (AWG 16)

Characteristic values to EN ISO 13849-1

Classification/underlying standards PL d

System structure Category 3

Probability of dangerous failure per hour (PFH value)

0 (fault exclusion)

Mission time / service life 20 years

Safe condition Brake de-energized

Safety function SBC (safe brake control) according to IEC 61800-5-2

Operating Instructions – Safety-Related BST Brake Module

Pi

fkVA

Hz

n

35

Page 36: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

36

10 imension drawing of BST in control cabinet designechnical Data

10.4 Dimension drawing of BST in control cabinet designThe following figure shows the dimension drawings of BST in control cabinet design:

All dimensions in mm (in).

9007199388556683

89

10

1

13

5

70

99

121.5

74

135 (5.31)

(4.78)

(2.7

6)

(5.3

1)

(3.9

8)

(3.5

0)

(3.9

0)

(2.91)

DT

Pi

fkVA

Hz

n

Operating Instructions – Safety-Related BST Brake Module

Page 37: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

11Address List

11 Address List

Germany

HeadquartersProductionSales

Bruchsal SEW-EURODRIVE GmbH & Co KGErnst-Blickle-Straße 42 D-76646 BruchsalP.O. BoxPostfach 3023 • D-76642 Bruchsal

Tel. +49 7251 75-0Fax +49 7251 75-1970http://[email protected]

Production / Indus-trial Gears

Bruchsal SEW-EURODRIVE GmbH & Co KGChristian-Pähr-Str.10D-76646 Bruchsal

Tel. +49 7251 75-0Fax +49 7251 75-2970

Service Compe-tence Center

Central SEW-EURODRIVE GmbH & Co KGErnst-Blickle-Straße 1 D-76676 Graben-Neudorf

Tel. +49 7251 75-1710Fax +49 7251 [email protected]

North SEW-EURODRIVE GmbH & Co KGAlte Ricklinger Straße 40-42 D-30823 Garbsen (near Hannover)

Tel. +49 5137 8798-30Fax +49 5137 [email protected]

East SEW-EURODRIVE GmbH & Co KGDänkritzer Weg 1D-08393 Meerane (near Zwickau)

Tel. +49 3764 7606-0Fax +49 3764 [email protected]

South SEW-EURODRIVE GmbH & Co KGDomagkstraße 5D-85551 Kirchheim (near München)

Tel. +49 89 909552-10Fax +49 89 [email protected]

West SEW-EURODRIVE GmbH & Co KGSiemensstraße 1D-40764 Langenfeld (near Düsseldorf)

Tel. +49 2173 8507-30Fax +49 2173 [email protected]

Electronics SEW-EURODRIVE GmbH & Co KGErnst-Blickle-Straße 42 D-76646 Bruchsal

Tel. +49 7251 75-1780Fax +49 7251 [email protected]

Drive Service Hotline / 24 Hour Service +49 180 5 SEWHELP+49 180 5 739435714 euro cents/min on the German land-line network. Max 42 euro cents/min from a German mobile network. Prices for mobile and international calls may differ.

Additional addresses for service in Germany provided on request!

France

ProductionSalesService

Haguenau SEW-USOCOME 48-54 route de Soufflenheim B. P. 20185F-67506 Haguenau Cedex

Tel. +33 3 88 73 67 00 Fax +33 3 88 73 66 00http://[email protected]

Production Forbach SEW-USOCOME Zone industrielle Technopôle Forbach SudB. P. 30269F-57604 Forbach Cedex

Tel. +33 3 87 29 38 00

AssemblySalesService

Bordeaux SEW-USOCOME Parc d'activités de Magellan62 avenue de Magellan - B. P. 182F-33607 Pessac Cedex

Tel. +33 5 57 26 39 00Fax +33 5 57 26 39 09

Lyon SEW-USOCOME Parc d'affaires RooseveltRue Jacques TatiF-69120 Vaulx en Velin

Tel. +33 4 72 15 37 00Fax +33 4 72 15 37 15

Operating Instructions – Safety-Related BST Brake Module

37
Page 38: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

38

11 ddress List

Nantes SEW-USOCOME Parc d’activités de la forêt4 rue des FontenellesF-44140 Le Bignon

Tel. +33 2 40 78 42 00Fax +33 2 40 78 42 20

Paris SEW-USOCOME Zone industrielle 2 rue Denis Papin F-77390 Verneuil I'Etang

Tel. +33 1 64 42 40 80Fax +33 1 64 42 40 88

Additional addresses for service in France provided on request!

Algeria

Sales Alger REDUCOM Sarl 16, rue des Frères ZaghnouneBellevue16200 El Harrach Alger

Tel. +213 21 8214-91Fax +213 21 [email protected]://www.reducom-dz.com

Argentina

AssemblySales

Buenos Aires SEW EURODRIVE ARGENTINA S.A.Centro Industrial Garin, Lote 35Ruta Panamericana Km 37,51619 Garin

Tel. +54 3327 4572-84Fax +54 3327 [email protected]://www.sew-eurodrive.com.ar

Australia

AssemblySalesService

Melbourne SEW-EURODRIVE PTY. LTD.27 Beverage DriveTullamarine, Victoria 3043

Tel. +61 3 9933-1000Fax +61 3 9933-1003http://[email protected]

Sydney SEW-EURODRIVE PTY. LTD.9, Sleigh Place, Wetherill Park New South Wales, 2164

Tel. +61 2 9725-9900Fax +61 2 [email protected]

Austria

AssemblySalesService

Wien SEW-EURODRIVE Ges.m.b.H. Richard-Strauss-Strasse 24A-1230 Wien

Tel. +43 1 617 55 00-0Fax +43 1 617 55 00-30http://[email protected]

Belarus

Sales Minsk SEW-EURODRIVE BYRybalkoStr. 26BY-220033 Minsk

Tel.+375 17 298 47 56 / 298 47 58Fax +375 17 298 47 54http://[email protected]

Belgium

AssemblySalesService

Brussels SEW-EURODRIVE n.v./s.a.Researchpark Haasrode 1060Evenementenlaan 7BE-3001 Leuven

Tel. +32 16 386-311Fax +32 16 386-336http://[email protected]

Service Compe-tence Center

Industrial Gears SEW-EURODRIVE n.v./s.a.Rue de Parc Industriel, 31BE-6900 Marche-en-Famenne

Tel. +32 84 219-878Fax +32 84 219-879http://[email protected]

Brazil

ProductionSalesService

Sao Paulo SEW-EURODRIVE Brasil Ltda.Avenida Amâncio Gaiolli, 152 - Rodovia Presi-dente Dutra Km 208Guarulhos - 07251-250 - SPSAT - SEW ATENDE - 0800 7700496

Tel. +55 11 2489-9133Fax +55 11 2480-3328http://[email protected]

France

A

Operating Instructions – Safety-Related BST Brake Module

Page 39: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

11Address List

Bulgaria

Sales Sofia BEVER-DRIVE GmbHBogdanovetz Str.1BG-1606 Sofia

Tel. +359 2 9151160Fax +359 2 [email protected]

Cameroon

Sales Douala Electro-ServicesRue Drouot AkwaB.P. 2024Douala

Tel. +237 33 431137Fax +237 33 [email protected]

Canada

AssemblySalesService

Toronto SEW-EURODRIVE CO. OF CANADA LTD. 210 Walker Drive Bramalea, ON L6T 3W1

Tel. +1 905 791-1553Fax +1 905 791-2999http://[email protected]

Vancouver SEW-EURODRIVE CO. OF CANADA LTD.Tilbury Industrial Park7188 Honeyman Street Delta, BC V4G 1G1

Tel. +1 604 946-5535Fax +1 604 [email protected]

Montreal SEW-EURODRIVE CO. OF CANADA LTD.2555 Rue Leger Lasalle, PQ H8N 2V9

Tel. +1 514 367-1124Fax +1 514 [email protected]

Additional addresses for service in Canada provided on request!

Chile

AssemblySalesService

Santiago de Chile

SEW-EURODRIVE CHILE LTDA.Las Encinas 1295Parque Industrial Valle GrandeLAMPARCH-Santiago de ChileP.O. BoxCasilla 23 Correo Quilicura - Santiago - Chile

Tel. +56 2 75770-00Fax +56 2 75770-01http://[email protected]

China

ProductionAssemblySalesService

Tianjin SEW-EURODRIVE (Tianjin) Co., Ltd.No. 46, 7th Avenue, TEDATianjin 300457

Tel. +86 22 25322612Fax +86 22 [email protected]://www.sew-eurodrive.com.cn

AssemblySalesService

Suzhou SEW-EURODRIVE (Suzhou) Co., Ltd.333, Suhong Middle RoadSuzhou Industrial ParkJiangsu Province, 215021

Tel. +86 512 62581781Fax +86 512 [email protected]

Guangzhou SEW-EURODRIVE (Guangzhou) Co., Ltd.No. 9, JunDa RoadEast Section of GETDDGuangzhou 510530

Tel. +86 20 82267890Fax +86 20 [email protected]

Shenyang SEW-EURODRIVE (Shenyang) Co., Ltd.10A-2, 6th RoadShenyang Economic Technological Develop-ment AreaShenyang, 110141

Tel. +86 24 25382538Fax +86 24 [email protected]

Wuhan SEW-EURODRIVE (Wuhan) Co., Ltd.10A-2, 6th RoadNo. 59, the 4th Quanli Road, WEDA430056 Wuhan

Tel. +86 27 84478388Fax +86 27 [email protected]

Operating Instructions – Safety-Related BST Brake Module

39
Page 40: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

40

11 ddress List

Xi'An SEW-EURODRIVE (Xi'An) Co., Ltd.No. 12 Jinye 2nd RoadXi'An High-Technology Industrial Development ZoneXi'An 710065

Tel. +86 29 68686262Fax +86 29 [email protected]

Additional addresses for service in China provided on request!

Colombia

AssemblySalesService

Bogotá SEW-EURODRIVE COLOMBIA LTDA. Calle 22 No. 132-60Bodega 6, Manzana BSantafé de Bogotá

Tel. +57 1 54750-50Fax +57 1 54750-44http://[email protected]

Croatia

SalesService

Zagreb KOMPEKS d. o. o.Zeleni dol 10HR 10 000 Zagreb

Tel. +385 1 4613-158Fax +385 1 [email protected]

Czech Republic

Sales Prague SEW-EURODRIVE CZ S.R.O.Business Centrum Praha Lužná 591CZ-16000 Praha 6 - Vokovice

Tel. +420 255 709 601Fax +420 220 121 237http://[email protected]

Denmark

AssemblySalesService

Copenhagen SEW-EURODRIVEA/SGeminivej 28-30DK-2670 Greve

Tel. +45 43 9585-00Fax +45 43 9585-09http://[email protected]

Egypt

SalesService

Cairo Copam Egypt for Engineering & Agencies33 EI Hegaz ST, Heliopolis, Cairo

Tel. +20 2 22566-299 +1 23143088Fax +20 2 22594-757http://www.copam-egypt.com/ [email protected]

Estonia

Sales Tallin ALAS-KUUL ASReti tee 4EE-75301 Peetri küla, Rae vald, Harjumaa

Tel. +372 6593230Fax +372 [email protected]

Finland

AssemblySalesService

Lahti SEW-EURODRIVE OYVesimäentie 4FIN-15860 Hollola 2

Tel. +358 201 589-300Fax +358 3 780-6211http://[email protected]

ProductionAssembly

Karkkila SEW Industrial Gears OyValurinkatu 6, PL 8FI-03600 Karkkila, 03601 Karkkila

Tel. +358 201 589-300Fax +358 201 [email protected]://www.sew-eurodrive.fi

Gabon

Sales Libreville ESG Electro Services GabunFeu Rouge Lalala1889 LibrevilleGabun

Tel. +241 741059Fax +241 [email protected]

China

A

Operating Instructions – Safety-Related BST Brake Module

Page 41: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

11Address List

Great Britain

AssemblySalesService

Normanton SEW-EURODRIVE Ltd.Beckbridge Industrial Estate NormantonWest Yorkshire WF6 1QR

Tel. +44 1924 893-855Fax +44 1924 893-702http://[email protected]

Drive Service Hotline / 24 Hour Service Tel. 01924 896911

Greece

Sales Athens Christ. Boznos & Son S.A.12, K. Mavromichali StreetP.O. Box 80136GR-18545 Piraeus

Tel. +30 2 1042 251-34 Fax +30 2 1042 251-59http://[email protected]

Hong Kong

AssemblySalesService

Hong Kong SEW-EURODRIVE LTD.Unit No. 801-806, 8th FloorHong Leong Industrial ComplexNo. 4, Wang Kwong Road Kowloon, Hong Kong

Tel. +852 36902200Fax +852 [email protected]

Hungary

SalesService

Budapest SEW-EURODRIVE Kft.H-1037 BudapestKunigunda u. 18

Tel. +36 1 437 06-58Fax +36 1 437 [email protected]

India

Registered OfficeAssemblySalesService

Vadodara SEW-EURODRIVE India Private LimitedPlot No. 4, GIDCPOR Ramangamdi • Vadodara - 391 243Gujarat

Tel. +91 265 3045200, +91 265 2831086Fax +91 265 3045300, +91 265 2831087http://[email protected]

AssemblySalesService

Chennai SEW-EURODRIVE India Private LimitedPlot No. K3/1, Sipcot Industrial Park Phase IIMambakkam VillageSriperumbudur - 602105Kancheepuram Dist, Tamil Nadu

Tel. +91 44 37188888Fax +91 44 [email protected]

Ireland

SalesService

Dublin Alperton Engineering Ltd. 48 Moyle RoadDublin Industrial EstateGlasnevin, Dublin 11

Tel. +353 1 830-6277Fax +353 1 [email protected]://www.alperton.ie

Israel

Sales Tel-Aviv Liraz Handasa Ltd. Ahofer Str 34B / 22858858 Holon

Tel. +972 3 5599511Fax +972 3 5599512http://[email protected]

Italy

AssemblySalesService

Solaro SEW-EURODRIVE di R. Blickle & Co.s.a.s.Via Bernini,14 I-20020 Solaro (Milano)

Tel. +39 02 96 9801Fax +39 02 96 799781http://[email protected]

Operating Instructions – Safety-Related BST Brake Module

41
Page 42: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

42

11 ddress List

Ivory Coast

Sales Abidjan SICASociété industrielle & commerciale pour l'Afrique165, Boulevard de Marseille26 BP 1115 Abidjan 26

Tel. +225 21 25 79 44Fax +225 21 25 88 [email protected]

Japan

AssemblySalesService

Iwata SEW-EURODRIVE JAPAN CO., LTD 250-1, Shimoman-no,IwataShizuoka 438-0818

Tel. +81 538 373811Fax +81 538 373855http://[email protected]

Kazakhstan

Sales Almaty ТОО "СЕВ-ЕВРОДРАЙВ"пр.Райымбека, 348050061 г. АлматыРеспублика Казахстан

Тел. +7 (727) 334 1880Факс +7 (727) 334 1881http://[email protected]

Latvia

Sales Riga SIA Alas-KuulKatlakalna 11CLV-1073 Riga

Tel. +371 6 7139253Fax +371 6 7139386http://[email protected]

Lebanon

Sales Beirut Gabriel Acar & Fils sarlB. P. 80484Bourj Hammoud, Beirut

Tel. +961 1 510 532Fax +961 1 494 [email protected]

JordanKuwaitSaudi ArabiaSyria

Beirut Middle East Drives S.A.L. (offshore)Sin El Fil.B. P. 55-378Beirut

Tel. +961 1 494 786Fax +961 1 494 [email protected]://www.medrives.com

Lithuania

Sales Alytus UAB IrsevaStatybininku 106CLT-63431 Alytus

Tel. +370 315 79204Fax +370 315 [email protected]://www.sew-eurodrive.lt

Luxembourg

AssemblySalesService

Brussels SEW-EURODRIVE n.v./s.a.Researchpark Haasrode 1060Evenementenlaan 7BE-3001 Leuven

Tel. +32 16 386-311Fax +32 16 386-336http://[email protected]

Malaysia

AssemblySalesService

Johore SEW-EURODRIVE SDN BHD No. 95, Jalan Seroja 39, Taman Johor Jaya81000 Johor Bahru, JohorWest Malaysia

Tel. +60 7 3549409Fax +60 7 [email protected]

Mexico

AssemblySalesService

Quéretaro SEW-EURODRIVE MEXICO SA DE CVSEM-981118-M93Tequisquiapan No. 102Parque Industrial QuéretaroC.P. 76220Quéretaro, México

Tel. +52 442 1030-300Fax +52 442 1030-301http://[email protected]

A

Operating Instructions – Safety-Related BST Brake Module

Page 43: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

11Address List

Morocco

SalesService

Mohammedia SEW EURODRIVE SARLZ.I. Sud Ouest - Lot 282ème étageMohammedia 28810

Tel. +212 523 32 27 80/81Fax +212 523 32 27 [email protected]://www.sew-eurodrive.ma

Netherlands

AssemblySalesService

Rotterdam VECTOR Aandrijftechniek B.V. Industrieweg 175 NL-3044 AS RotterdamPostbus 10085NL-3004 AB Rotterdam

Tel. +31 10 4463-700Fax +31 10 4155-552Service: 0800-SEWHELPhttp://[email protected]

New Zealand

AssemblySalesService

Auckland SEW-EURODRIVE NEW ZEALAND LTD. P.O. Box 58-428 82 Greenmount driveEast Tamaki Auckland

Tel. +64 9 2745627Fax +64 9 2740165http://[email protected]

Christchurch SEW-EURODRIVE NEW ZEALAND LTD. 10 Settlers Crescent, FerrymeadChristchurch

Tel. +64 3 384-6251Fax +64 3 [email protected]

Norway

AssemblySalesService

Moss SEW-EURODRIVE A/SSolgaard skog 71N-1599 Moss

Tel. +47 69 24 10 20Fax +47 69 24 10 40http://[email protected]

Pakistan

Sales Karachi Industrial Power DrivesAl-Fatah Chamber A/3, 1st Floor Central Com-mercial Area,Sultan Ahmed Shah Road, Block 7/8, Karachi

Tel. +92 21 452 9369Fax +92-21-454 [email protected]

Peru

AssemblySalesService

Lima SEW DEL PERU MOTORES REDUCTORES S.A.C.Los Calderos, 120-124Urbanizacion Industrial Vulcano, ATE, Lima

Tel. +51 1 3495280Fax +51 1 3493002http://[email protected]

Poland

AssemblySalesService

Lodz SEW-EURODRIVE Polska Sp.z.o.o.ul. Techniczna 5 PL-92-518 Łódź

Tel. +48 42 676 53 00Fax +48 42 676 53 49http://[email protected]

Service Tel. +48 42 6765332 / 42 6765343Fax +48 42 6765346

Linia serwisowa Hotline 24HTel. +48 602 739 739

(+48 602 SEW SEW)[email protected]

Portugal

AssemblySalesService

Coimbra SEW-EURODRIVE, LDA.Apartado 15 P-3050-901 Mealhada

Tel. +351 231 20 9670Fax +351 231 20 3685http://[email protected]

Operating Instructions – Safety-Related BST Brake Module

43
Page 44: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

44

11 ddress List

Romania

SalesService

Bucharest Sialco Trading SRL str. Madrid nr.4 011785 Bucuresti

Tel. +40 21 230-1328Fax +40 21 230-7170 [email protected]

Russia

AssemblySalesService

St. Petersburg ZAO SEW-EURODRIVE P.O. Box 36 195220 St. Petersburg Russia

Tel. +7 812 3332522 +7 812 5357142Fax +7 812 3332523http://[email protected]

Senegal

Sales Dakar SENEMECA Mécanique GénéraleKm 8, Route de Rufisque B.P. 3251, Dakar

Tel. +221 338 494 770Fax +221 338 494 [email protected]://www.senemeca.com

Serbia

Sales Beograd DIPAR d.o.o.Ustanicka 128aPC Košum, IV spratSRB-11000 Beograd

Tel. +381 11 347 3244 / +381 11 288 0393Fax +381 11 347 [email protected]

Singapore

AssemblySalesService

Singapore SEW-EURODRIVE PTE. LTD. No 9, Tuas Drive 2 Jurong Industrial Estate Singapore 638644

Tel. +65 68621701Fax +65 68612827http://[email protected]

Slovakia

Sales Bratislava SEW-Eurodrive SK s.r.o.Rybničná 40SK-831 06 Bratislava

Tel. +421 2 33595 202Fax +421 2 33595 [email protected]://www.sew-eurodrive.sk

Žilina SEW-Eurodrive SK s.r.o.Industry Park - PChZulica M.R.Štefánika 71SK-010 01 Žilina

Tel. +421 41 700 2513Fax +421 41 700 [email protected]

Banská Bystrica SEW-Eurodrive SK s.r.o.Rudlovská cesta 85SK-974 11 Banská Bystrica

Tel. +421 48 414 6564Fax +421 48 414 [email protected]

Košice SEW-Eurodrive SK s.r.o.Slovenská ulica 26SK-040 01 Košice

Tel. +421 55 671 2245Fax +421 55 671 [email protected]

Slovenia

SalesService

Celje Pakman - Pogonska Tehnika d.o.o.UI. XIV. divizije 14SLO - 3000 Celje

Tel. +386 3 490 83-20Fax +386 3 490 [email protected]

South Africa

AssemblySalesService

Johannesburg SEW-EURODRIVE (PROPRIETARY) LIMITEDEurodrive House Cnr. Adcock Ingram and Aerodrome RoadsAeroton Ext. 2Johannesburg 2013P.O.Box 90004Bertsham 2013

Tel. +27 11 248-7000Fax +27 11 494-3104http://[email protected]

A

Operating Instructions – Safety-Related BST Brake Module

Page 45: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

11Address List

Cape Town SEW-EURODRIVE (PROPRIETARY) LIMITED Rainbow ParkCnr. Racecourse & Omuramba RoadMontague GardensCape TownP.O.Box 36556Chempet 7442 Cape Town

Tel. +27 21 552-9820Fax +27 21 552-9830Telex 576 [email protected]

Durban SEW-EURODRIVE (PROPRIETARY) LIMITED2 Monaco PlacePinetownDurbanP.O. Box 10433, Ashwood 3605

Tel. +27 31 700-3451Fax +27 31 [email protected]

Nelspruit SEW-EURODRIVE (PTY) LTD.7 Christie CrescentVintoniaP.O.Box 1942Nelspruit 1200

Tel. +27 13 752-8007Fax +27 13 [email protected]

South Korea

AssemblySalesService

Ansan-City SEW-EURODRIVE KOREA CO., LTD. B 601-4, Banweol Industrial Estate 1048-4, Shingil-DongAnsan 425-120

Tel. +82 31 492-8051Fax +82 31 492-8056http://[email protected]

Busan SEW-EURODRIVE KOREA Co., Ltd.No. 1720 - 11, Songjeong - dongGangseo-kuBusan 618-270

Tel. +82 51 832-0204Fax +82 51 [email protected]

Spain

AssemblySalesService

Bilbao SEW-EURODRIVE ESPAÑA, S.L. Parque Tecnológico, Edificio, 302E-48170 Zamudio (Vizcaya)

Tel. +34 94 43184-70Fax +34 94 43184-71http://[email protected]

Sweden

AssemblySalesService

Jönköping SEW-EURODRIVE ABGnejsvägen 6-8S-55303 JönköpingBox 3100 S-55003 Jönköping

Tel. +46 36 3442 00Fax +46 36 3442 80http://[email protected]

Switzerland

AssemblySalesService

Basel Alfred lmhof A.G.Jurastrasse 10 CH-4142 Münchenstein bei Basel

Tel. +41 61 417 1717Fax +41 61 417 1700http://[email protected]

Thailand

AssemblySalesService

Chonburi SEW-EURODRIVE (Thailand) Ltd.700/456, Moo.7, DonhuarohMuang Chonburi 20000

Tel. +66 38 454281Fax +66 38 [email protected]

Tunisia

Sales Tunis T. M.S. Technic Marketing ServiceZone Industrielle Mghira 2Lot No. 392082 Fouchana

Tel. +216 79 40 88 77Fax +216 79 40 88 66http://[email protected]

South Africa

Operating Instructions – Safety-Related BST Brake Module

45
Page 46: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

46

11 ddress List

Turkey

AssemblySalesService

Istanbul SEW-EURODRIVE Hareket Sistemleri San. ve Tic. Ltd. Sti. Gebze Organize Sanayi Bölgesi 400.Sokak No:401TR - 41480 Gebze, Instanbul

Tel. +90 262 999 1000 http://[email protected]

Ukraine

AssemblySalesService

Dnepropetrovsk SEW-EURODRIVEStr. Rabochaja 23-B, Office 40949008 Dnepropetrovsk

Tel. +380 56 370 3211Fax +380 56 372 2078http://[email protected]

United Arab Emirates

SalesService

Sharjah Copam Middle East (FZC)Sharjah Airport International Free ZoneP.O. Box 120709Sharjah

Tel. +971 6 5578-488Fax +971 6 [email protected]

USA

ProductionAssemblySalesService

Southeast Region

SEW-EURODRIVE INC. 1295 Old Spartanburg Highway P.O. Box 518Lyman, S.C. 29365

Tel. +1 864 439-7537Fax Sales +1 864 439-7830Fax Manufacturing +1 864 439-9948Fax Assembly +1 864 439-0566Fax Confidential/HR +1 864 949-5557http://[email protected]

AssemblySalesService

Northeast Region

SEW-EURODRIVE INC. Pureland Ind. Complex 2107 High Hill Road, P.O. Box 481Bridgeport, New Jersey 08014

Tel. +1 856 467-2277Fax +1 856 [email protected]

Midwest Region SEW-EURODRIVE INC.2001 West Main Street Troy, Ohio 45373

Tel. +1 937 335-0036Fax +1 937 [email protected]

Southwest Region

SEW-EURODRIVE INC.3950 Platinum Way Dallas, Texas 75237

Tel. +1 214 330-4824Fax +1 214 [email protected]

Western Region SEW-EURODRIVE INC. 30599 San Antonio St.Hayward, CA 94544

Tel. +1 510 487-3560Fax +1 510 [email protected]

Additional addresses for service in the USA provided on request!

Venezuela

AssemblySalesService

Valencia SEW-EURODRIVE Venezuela S.A.Av. Norte Sur No. 3, Galpon 84-319Zona Industrial Municipal NorteValencia, Estado Carabobo

Tel. +58 241 832-9804Fax +58 241 838-6275http://[email protected]@cantv.net

Vietnam

Sales Ho Chi Minh City All sectors except for ports, mining and off-shore:Nam Trung Co., Ltd250 Binh Duong Avenue, Thu Dau Mot Town, Binh Duong ProvinceHCM office: 91 Tran Minh Quyen StreetDistrict 10, Ho Chi Minh City

Tel. +84 8 8301026Fax +84 8 [email protected]@[email protected]

A

Operating Instructions – Safety-Related BST Brake Module

Page 47: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

11Address List

Ports, mining and offshore:DUC VIET INT LTDIndustrial Trading and Engineering ServicesA75/6B/12 Bach Dang Street, Ward 02,Tan Binh District, 70000 Ho Chi Minh City

Tel. +84 8 62969 609Fax +84 8 62938 [email protected]

Hanoi Nam Trung Co., LtdR.205B Tung Duc Building22 Lang ha StreetDong Da District, Hanoi City

Tel. +84 4 37730342Fax +84 4 [email protected]

Vietnam

Operating Instructions – Safety-Related BST Brake Module

47
Page 48: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

48

Index

Index

AApplicable documentation........................................6Applications

Disconnection of group drives............................33Disconnection of single drives via inverter and DFS11B/21B fieldbus interface..........................32Disconnection of single drives via MOVIDRIVE® B inverter ...............................................................31

BBlock diagram

BST ....................................................................11Brake function

Checking ............................................................28BST

Block diagram ....................................................11Dimension drawings...........................................36Nameplate..........................................................19Safety characteristics.........................................35Technical data....................................................34Type designation................................................19Unit replacement................................................29Unit structure......................................................20

CCopyright..................................................................6

DDesignated use ........................................................8Dimension drawings

BST ....................................................................36Disposal ...................................................................9Documentation, applicable.......................................6Double-pole safe disconnection.............................24

EElectrical installation...............................................23

Double-pole safe disconnection.........................24Information .........................................................23Single-pole safe disconnection ..........................25

Embedded safety notes ...........................................5Exclusion of liability ..................................................6External safety controller

Requirements.....................................................16

IInformation on electrical installation

Brake cable (terminal 13/14/15).........................23Functional control cable (terminal 3/4)...............23Safety-related control cable (terminal 5/6).........23Supply cable (terminal 1/2) ................................23

Inspection ..............................................................28Inspection intervals ................................................28Installation

electrical.............................................................23Mechanical.........................................................21Requirements ....................................................14

Integrated safety technology..................................10

LLiability.....................................................................6Liability for defects ...................................................6

MMaintenance ..........................................................28Maintenance intervals............................................28Mechanical installation...........................................21

NNameplate BST .....................................................19Notes

Designation in the documentation .......................5

OOperating states ....................................................26Operation

Requirements ....................................................18

PPermitted unit combinations ..................................13Product names.........................................................6

RRequirements

External safety controller ...................................16Installation..........................................................14Operation ...........................................................18Startup ...............................................................17

Restrictions ............................................................12

Operating Instructions – Safety-Related

BST Brake Module
Page 49: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

Index

SSafe condition ........................................................10Safe disconnection

double-pole ........................................................24single-pole..........................................................25

Safety concept .......................................................10Safety control, external

Requirements.....................................................16Safety notes .............................................................7

Designation in the documentation........................5Structure of the embedded safety notes ..............5Structure of the section-related safety notes .......5

Safety switching deviceSample circuit ....................................................17

Safety technologyIntegrated...........................................................10

Safety-relevant conditions......................................13SBC safety function (Safe Brake Control) according

to IEC 61800-5-2................................................11SBC, safety function according to IEC 61800-5-2..11Scope of delivery

BST ....................................................................20Section-related safety notes ....................................5Service ...................................................................28Signal words in the safety notes ..............................5Single-pole safe disconnection ..............................25

Startup ...................................................................26Startup requirements .........................................17

Support rail mounting.............................................21Minimum clearance and mounting position .......22Mounting BST onto a support rail ......................21Removing BST from the support rail..................22

TTarget group ............................................................8Technical data

BST....................................................................34General ..............................................................34Safety characteristics.........................................35Safety-related control voltage ............................35

Terminal assignmentBST....................................................................20

Trademarks..............................................................6Transport .................................................................8Type designation BST ...........................................19

UUnit combinations

Permitted ...........................................................13Unit design

Safety-relevant BST brake module....................19Unit structure

BST....................................................................20

Operating Instructions – Safety-Related BST Brake Module

49
Page 50: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related
Page 51: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related
Page 52: Safety-Related BST Brake Module / Operating Instructions ... · 10.4 Dimension drawing of BST in control cabinet design..... 36 11 Address List ... Operating Instructions – Safety-Related

SEW-EURODRIVE—Driving the world

SEW-EURODRIVEDriving the world

www.sew-eurodrive.com

SEW-EURODRIVE GmbH & Co KGP.O. Box 3023D-76642 Bruchsal/GermanyPhone +49 7251 75-0Fax +49 7251 [email protected]