Rittal RiMatrixS presentatie
-
Upload
axi -
Category
Technology
-
view
137 -
download
1
description
Transcript of Rittal RiMatrixS presentatie
1 Filip Gosselin / Product Manager IT
2
Datacenter infrastructure
Standardisation or not?
Filip Gosselin / Product Manager IT
Rittal - Facts World leader in system solutions
Filip Gosselin / Product Manager IT
Founded in 1961
Over 10,000 employees worldwide
Over 60 subsidiaries
11 production sites
Member of the Friedhelm Loh Group
together with:
Eplan, LKH, Kiesling Cideon and Stahlo
Products and solutions:
Enclosures
Power distribution
Climate control
IT infrastructure
Software & services
4
Rittal - A powerful alliance with the Friedhelm Loh Group
Family- owned business
Filip Gosselin / Product Manager IT
Rittal - Facts World leader in system solutions
Filip Gosselin / Product Manager IT
Rittal Belgium
+/- 52 full-time employees
Distribution unit for Belgium
Inbound: 2 trucks/day
Outbound: 5 trucks/day
3700 M² warehouse
4068 pallet rack locations
2200 bin locations
Delivery of all regions, 2 times a week
Workshop for modification and
assembly
Rittal – Products and Solutions Complete product portfolio for data centre infrastructure solutions
Filip Gosselin / Product Manager IT
Product portfolio
Power
distribution
Monitoring Security
solutions
IT racks/
server racks
Service and
support
Climate control
Data centre
Rittal – Products and Solutions Market trends and future developments
Filip Gosselin / Product Manager IT
search engines mobile apps virtualisation
simulation
file sharing
social media
big data
rendering
weather
8
Datacenter infrastructure
Standardisation or not?
Filip Gosselin / Product Manager IT
9
Standardisation:
Standardisation is the process of developing and
implementing technical standards.
Standardisation can help to maximize compatibility,
interoperability, safety, repeatability, or quality.
It can also facilitate commoditization of formerly
custom processes and create a situation in which all
parties can realize mutual gains.
Source: Wikipedia
Filip Gosselin / Product Manager IT
10 Filip Gosselin / Product Manager IT
If it wasn't for standarisation, the most simple everyday
objects would not have existed in the form as we know
them now.
Data centre standardisation: A change of paradigm Is every data centre really unique?
Filip Gosselin / Product Manager IT
Data centre standardisation: A change of paradigm Is every data centre really unique?
Filip Gosselin / Product Manager IT
Existing data centre structures
Rack area with serverracks and networking racks
Cold/hot aisle containment
Cooling internal: Rack, inline, CRAC,…
Cooling external: Chillers, drycoolers, …
UPS room
Low-voltage power distribution
Question yourselves: does every data centre really need to
be unique?
Demands on IT managers Complexity – Flexibility – Costs – Security
Filip Gosselin / Product Manager IT
How can I react flexibly to the changing demands of internal and external customers?
How can I manage the constantly increasing complexity?
Which concrete measures can I take to combat increasing costs?
How can I ensure the availability of my IT services?
Demands on IT managers Complexity – Flexibility – Costs – Security
Filip Gosselin / Product Manager IT
Expandability, scalability
Expansion for efficiency measurement
Secure, reliable operation
Transparent and consistent IT management
Physical security
Early fire detection
Fire extinguishing
Access log
Increasing planning needs
IT infrastructures
Climate efficiency
Data centre infrastructure management
IT load over course of the day/month/quarter
Managed reports
Demands on IT managers Frustration? Or relaxed?
Filip Gosselin / Product Manager IT
Filip Gosselin / Product Manager IT
Complexity
Complexity in data centre design Keep IT simple?
Filip Gosselin / Product Manager IT
18 Filip Gosselin / Product Manager IT
The first mass-produced data centre
RiMatrix S
Complexity in data centre design Keep IT simple?
Filip Gosselin / Product Manager IT
Dimensions: LxWxH 7,000 x 2,750 x 2,710 mm = 19.25 m²
Electrical performance: 60 kW redundant
Usable U: 294
Cooling output: 60 kW redundant
Ready-for-connection
Integrated partitions
Power
technology/UPS
Power distribution
Fire
detection/fire
extinguishing
Cable duct
system Base system Cold aisle
containment
Climate control
technology
19" rack system
Complexity in data centre design IT Infrastructures
Filip Gosselin / Product Manager IT
Standard room Container Security rooms
Filip Gosselin / Product Manager IT
Flexibility
Complexity in data centre design Expandability - Flexibility
Filip Gosselin / Product Manager IT
Data centre module (bayed IT racks)
Basic data centre module
One bayed enclosure suite including
containment
Extended data centre module
Two bayed enclosure suites,
mirror symmetry
Design (for each module)
19” frame for max. packing density
Raised floor with supply channels for
power supply and cooling
Cable routes above the frame structure
Complexity in data centre design Expandability - scalability
Filip Gosselin / Product Manager IT
Modules
Complexity in data centre design Expandability - scalability
Filip Gosselin / Product Manager IT
Single 6,
60 kW n+1
Double 9,
180 kW n+1
Single 9,
90 kW n+1
Double 6,
120 kW n+1
Internal dimensions LxWxH
7,000 x 2,750 x 2,710 mm
Internal dimensions LxWxH
7,000 x 4,776 x 2,710 mm
Complexity in data centre design Expansion for efficiency measurement
Filip Gosselin / Product Manager IT
Modular UPS Redundant PDUs
Energy protection
Efficiency measurement intelligent PDU and LVMD
Power distribution
Complexity in data centre design Secure reliable operation
Filip Gosselin / Product Manager IT
Cooling
n+1 redundancy in cooling
Space-saving configuration
Chiller packages – Cooling container
Complexity in data centre design Secure reliable operation
Filip Gosselin / Product Manager IT
Climate area server: Max. server supply air
temperature within ASHRAE
limit threshold to increase
energy efficiency. Climate area UPS battery: A 10-year battery life-cycle is
normally specified for an
ambient temperature of 20ºC.
Using separate control of the air
volumes, lower supply air
temperatures can be achieved
compared to the server area
despite the same flow
temperature.
Flexibility in data centre design Transparent and consistent IT management
Filip Gosselin / Product Manager IT
Applications
▪ Server, storage, switches, router
▪ Applications, support, service level agreements
IT infrastructure
▪ Power and cooling supply
▪ Rack and room monitoring
Management software
(e.g. Tivoli, Nagios…) Management software (e.g. data centre
infrastructure management…)
Filip Gosselin / Product Manager IT
Costs
Costs in data centres Climate efficiency
Filip Gosselin / Product Manager IT
PUE
Costs in data centres Economic efficiency - PUE
Filip Gosselin / Product Manager IT
Exterior: 10°C
Flow: 22°C
Server supply air: 26°C
PUE: < 1,1
Fan speed: < 61%
delta T intake-side: < 18K
Guaranteed PUE
Costs in data centres Economic efficiency
Filip Gosselin / Product Manager IT
Source: © ASHRAE 2012 American Society of Heating, Refrigerating and Air-Conditioning Engineers © January 2012 by Ron Hughes-Data CentreDynamics
ASHRAE
Intelligent control algorithm, optimised system within the recommended values
Temperature 2004: 20ºC to 25ºC - recommended
2008: 18ºC to 27ºC - recommended
2011: 5ºC to 40ºC - permitted
Humidity 2004: 40% to 55% - recommended
2008: 35% to 60% - recommended
2011: 20% to 80% - recommended
Costs in data centres Data centre infrastructure management
Filip Gosselin / Product Manager IT
DCIM
Monitoring and visualisation of
all system-relevant parameters
Alarm management with e-mail
reports
Involvement in building services
management due to support
from OPC
Optional energy optimisation
* OPC = OLE (Object Linking and Embedding) for process control
Costs in data centres Data centre infrastructure management
Filip Gosselin / Product Manager IT
Server-out temperature (ºC)
IT load (kW)
Flow rate (l/min)
Infrastructure load (kW) Total load (kW)
Server-in temperature (ºC)
Delta p (Pa)
Filip Gosselin / Product Manager IT
Security
Security in data centres Early fire detection and fire extinguishing
Filip Gosselin / Product Manager IT
Automatic fire detection at a very early stage
Automatic alarm
Early fire detection
Fire extinguished by fire brigade
Fire warning and extinguishing system
Immediate and automatic extinction
Automatic fire detection at a very early stage
Automatic alarm
Security in data centres Physical security
Filip Gosselin / Product Manager IT
Fire Extinguishing
water
Corrosive
gases
Vandalism Unauthorised
access
Electromagn.
interference
Dust Falling debris Theft/
burglary
Standard room Container Security rooms
Unauthorised
access Falling debris Theft/
burglary
Fire Extinguishing
water
Security in data centres Simplified certification
Filip Gosselin / Product Manager IT
The data centre concept : RiMatrix S
The concept must accommodate any
availability claims by any customers.
This is based on the tier classification
(Tier I – IV).
Based on: DIN EN 50600-1;
VDE 0801-600-1:2012-01:2012-01
RiMatrix S systems are pre-certified so
that complete certifications are made
considerably more easily and more
quickly.
Pre-certified modules
Guaranteed quality!
Time-saving!
Predictable costs!
Filip Gosselin / Product Manager IT
Conclusion
Conclusion Standardisation = Flexibility + Costs + Efficiency + Security
Filip Gosselin / Product Manager IT
Security
A holistic organisation and high availability should be key factors for
the configuration of IT infrastructures and IT systems
Efficiency
Permanently increasing costs demand efficient planning and
efficient operation – with indices already available in the
planning/investment phase
Costs
An optimised IT infrastructure and control algorithms within the
ASHRAE recommended values help to combat increasing energy prices
Flexibility
Standardisation ensures faster availability of the IT infrastructure
and thus of the services / applications (time-to-market)
Technical and economic optimisation of design,
organisation and operation of data centres thanks to
RiMatrix S standardised data centre modules
Conclusion Motivation
Filip Gosselin / Product Manager IT
Conclusion Guaranteed performance
Filip Gosselin / Product Manager IT
PUE calculation already prior to implementation!
The data centre module:
It is a standard product
Efficiency performance curves have
been determined in the laboratory and
confirmed by TÜV
The PUE on the installation site can be
derived from these curves in relation to
the annual temperature curve
Guaranteed PUE, low absolute PUE
level up to € 27,000 at 60 kW, PUE 1.3
to 1.7
We guarantee the PUE rating!
Conclusion Guaranteed performance
Filip Gosselin / Product Manager IT
Single producer Turn-key delivery
Single contact For all questions
Financial framework Defined from the beginning, no additional costs
Pre-assembled modules Safety during installation
Planning security Minimisation of risks
Short assembly time Installation within 5 days
Planning costs halved Approx. € 5,000-10,000 at 60 kW
Operational safety Minimisation of risks
1:1 references Reference visits
Optimum operating features of the modules
Efficient operation
High availability
Thanks to pre-configured modules
Cost savings Reduced complexity Greater availability
Error-tolerant design
44 Filip Gosselin / Product Manager IT
Thank you!