Retaining Wall Buildsoft

12
Code Descriptions Unit be read in conjunction with preambles and specifications Retaining wall Excavation works A F131 Excavation; cut and dispose; earth m3 B F121 Excavation; cut to fill ; earth m3 C F141 Excavation; foundation; earth m3 D P111.1 m E F311 Filling; general; excavated material m2 F F410.1 m3 Concrete works G I111.1 m2 H I142 m3 J I145 m3 K I411.1 Formwork; sides; bases; rough finish m2 Item Ref The bills of quantities shall Drain excavation; in earth; depth not exceedng 1.5m; commencing from finished level; 300mm thick V-shape concrete drain Filling ancillaries; geotextiles; 19-40mm imported granite Insitu concrete designed mix; grade C15; blinding; 50mm thick Insitu concrete designed mix; grade C30; bases; 50mm thick Insitu concrete designed mix; grade C30; walls

description

wall

Transcript of Retaining Wall Buildsoft

Page 1: Retaining Wall Buildsoft

RETAINING WALL

Code Descriptions Unit

be read in conjunction with

preambles and specifications

Retaining wall

Excavation works

A F131 Excavation; cut and dispose; earth

m3

B F121 Excavation; cut to fill ; earthm3

C F141 Excavation; foundation; earth m3

D P111.1

m

E F311 Filling; general; excavated materialm2

F F410.1m3

Concrete works

G I111.1m2

H I142m3

J I145m3

K I411.1 Formwork; sides; bases; rough finishm2

Item Ref

The bills of quantities shall

Drain excavation; in earth; depth not exceedng 1.5m; commencing from finished level; 300mm thick V-shape concrete drain

Filling ancillaries; geotextiles; 19-40mm imported granite

Insitu concrete designed mix; grade C15; blinding; 50mm thick

Insitu concrete designed mix; grade C30; bases; 50mm thick

Insitu concrete designed mix; grade C30; walls

Page 2: Retaining Wall Buildsoft

L I414.1 Formwork; sides; walls; fair finishm2

RETAINING WALL

BQ/1

Page 3: Retaining Wall Buildsoft

RETAINING WALL

Code Descriptions Unit

be read in conjunction with

preambles and specifications

Concrete works (cont'd)

A I652.1

nr

B P250.1

m

C I523t

D 1525

t

Item Ref

The bills of quantities shall

Concrete ancillaries; inserts; other inserts; 200mm dameter; cast iron pipe; grouted into wall at 2.00 metres centre to centre

Surface drain; toe drain; concrete V-shape drain; 300mm x 300mm nominal size; 25mm thick lining

Reinforcement; high tensile bars; nominal diameter; 12mm

Reinforcement; high tensile bars; nominal diameter; 20mm

BQ/1

Page 4: Retaining Wall Buildsoft

RETAINING WALL

BQ/2

Page 5: Retaining Wall Buildsoft

RETAINING WALL

Code Descriptions Unit

Retaining wall

COLLECTION

Page No:BQ/1Page No:BQ/2

Item Ref

BQ/2

Page 6: Retaining Wall Buildsoft

RETAINING WALLBQ/3

Page 7: Retaining Wall Buildsoft

RETAINING WALL

Qty Rate (RM) Amount (RM)

2045

651

159

85

651

192

289

145

153

89

Page 8: Retaining Wall Buildsoft

765

To Collection RM

Page 9: Retaining Wall Buildsoft

RETAINING WALL

Qty Rate (RM) Amount (RM)

44

85

7

18

Page 10: Retaining Wall Buildsoft

To Collection RM

Page 11: Retaining Wall Buildsoft

RETAINING WALL

Qty Rate (RM) Amount (RM)

Page 12: Retaining Wall Buildsoft

To Summary RM