Case presentation (lab analytical quality assurance problem )
Quality assurance of sampling and analytical instruments
description
Transcript of Quality assurance of sampling and analytical instruments
![Page 1: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/1.jpg)
IH&S 725 Dr. Myers, C.I.H.
Quality assurance of sampling and analytical instruments
Lecture Notes
![Page 2: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/2.jpg)
IH&S 725 Dr. Myers C.I.H.
Three basic sources of variability
Workplace
Sampling
Analytical
![Page 3: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/3.jpg)
IH&S 725 Dr. Myers C.I.H.
Sampling Variability Results fromtwo types of error
Random or Statistical Errors
Systematic Errors
![Page 4: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/4.jpg)
IH&S 725 Dr. Myers C.I.H.
Workplace
Random
Systematic
![Page 5: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/5.jpg)
IH&S 725 Dr. Myers C.I.H.
Sampling Train
Random
Systematic
![Page 6: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/6.jpg)
IH&S 725 Dr. Myers C.I.H.
Analytical
Random
Systematic
![Page 7: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/7.jpg)
IH&S 725 Dr. Myers C.I.H.
Managing and minimizing systematic error
Most important for IH to control Calibrate
Check sampling train integrity Use blanks and control samples Periodic employee sampling Sample different conditions
![Page 8: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/8.jpg)
IH&S 725 Dr. Myers C.I.H.
Flow Calibration
Primary standards - Best
Secondary standards – OK
![Page 9: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/9.jpg)
IH&S 725 Dr. Myers C.I.H.
Check sampling train integrity
Properly assembled filter cassettes Tight connections Tubing with no leaks Pump diaphragms intact, etc…
![Page 10: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/10.jpg)
IH&S 725 Dr. Myers C.I.H.
Blanks and control samples
Field blank
![Page 11: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/11.jpg)
IH&S 725 Dr. Myers C.I.H.
Blanks and control samples
Media blank
![Page 12: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/12.jpg)
IH&S 725 Dr. Myers C.I.H.
Blanks and control samples
Reagent blank
Spikes
![Page 13: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/13.jpg)
IH&S 725 Dr. Myers C.I.H.
Preparing spikes – Problem # 1
To complete the sampling campaign you've undertaken you desire to collect a “spiked” sample in your lab at a known SO2 concentration and send it to the analytical lab with your field samples. In order to do this you must create a volume of air having a known SO2 concentration. What volume of SO2 gas must you add to a 100-liter gas-sampling bag to produce a SO2 concentration of 500 ppm?
![Page 14: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/14.jpg)
IH&S 725 Dr. Myers C.I.H.
Solution for problem #1
![Page 15: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/15.jpg)
IH&S 725 Dr. Myers C.I.H.
Preparing spikes – Problem # 1b
What mass of SO2 would you expect the lab to report back to you for this sample if you had sampled 10 liters of the “standard SO2 mixture” on the spiked filter?
![Page 16: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/16.jpg)
IH&S 725 Dr. Myers C.I.H.
Solution to Problem # 1b
![Page 17: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/17.jpg)
IH&S 725 Dr. Myers C.I.H.
Preparing spikes – Problem #2
We are sampling for methylene chloride and want to prepare a series of spiked samples that range in concentrations of 10% and 50% of the PEL value for a sample volume of 1L.
We need to prepare a volume of methylene chloride at known concentration
![Page 18: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/18.jpg)
IH&S 725 Dr. Myers C.I.H.
Solution to problem #2
![Page 19: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/19.jpg)
IH&S 725 Dr. Myers C.I.H.
![Page 20: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/20.jpg)
IH&S 725 Dr. Myers C.I.H.
Periodic employee sampling
Regular intervals e.g. every 6 months Randomly select employees of the same
SEG Sample as many workers as the budget
allows – not 1 or 2 unless your budget restricts you to that
Sample highest priority SEGs
![Page 21: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/21.jpg)
IH&S 725 Dr. Myers C.I.H.
Sample different conditions
Sample different shifts and different days of the week especially if weekend shifts are different from those used during the week
Sample different times of the year Sample under different run capacities within
what is considered normal, etc…
![Page 22: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/22.jpg)
IH&S 725 Dr. Myers C.I.H.
Managing and minimizing random errors
Can’t eliminate so we account for them in statements of uncertainty
Use coefficients of variability Confidence intervals, etc…
![Page 23: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/23.jpg)
IH&S 725 Dr. Myers C.I.H.
Cumulative Error or Total Coefficient of Variation
CV CV CV CVT 12
22
n2
Typical CV for a sampling pump is assumed to be .05
![Page 24: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/24.jpg)
IH&S 725 Dr. Myers C.I.H.
Example of using CVT
If the NIOSH method 1005 for methylene chloride reports a method overall precision (CVA) of 0.076 and we assume a pump CVP of 0.05 then the total CVT will be?
![Page 25: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/25.jpg)
IH&S 725 Dr. Myers C.I.H.
Solution for CVT example
![Page 26: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/26.jpg)
IH&S 725 Dr. Myers C.I.H.
Application of the CVT
You sample methylene chloride for 4 hrs at a flow rate of .15LPM and have a reported mass of 35ug. Report your concentration and its relative standard deviation.
![Page 27: Quality assurance of sampling and analytical instruments](https://reader030.fdocuments.in/reader030/viewer/2022020111/56815c0c550346895dc9ec78/html5/thumbnails/27.jpg)
IH&S 725 Dr. Myers C.I.H.
Answer