Pressure sensors from ifm 2016
-
Upload
ifm-electronic-gmbh -
Category
Technology
-
view
40 -
download
6
Transcript of Pressure sensors from ifm 2016
The right choice foryour application.
Pressure sensors from ifm.
ww
w.if
m.c
om
Pres
sure
sen
sors
years
W
ARRANTY
on ifm products
Gesamtkatalog EN 2015_Stilvorlage LK FrutigerOT_2010 DE_GB.qxd 17.11.14 12:50 Seite 3
2
Systems for pressure monitoringThe optimum solution for every requirement
Pressure sensors with displayfor industrial applications
Pressure sensorsfor mobile applications
Pressure sensors withanalogue displayfor hygienic applications
Pressure sensors with displayfor hygienic applications
Accessories
Pressure sensors without displayfor industrial applications
3
Ind
ust
rial
app
licat
ion
s w
ith
dis
pla
y
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
4 - 7
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
8 - 11
12 - 13
14 - 15
16 - 17
18 - 19
PN -1...600 -25...80
PT / PU 0...600 -40...125
PA -1...600 -25...90
PK -1...400 -25...80
PT / PU -1...600 -40...90
PS 0...1 0...60
PV 0...400 -25...80
PG24 -1...400 -25...80
PQ -1...10 0...60
Senso
r typ
e
Mea
surin
g range [
bar]
Med
ium
tem
perat
ure [°
C]
Display
IO-L
ink
Hydra
ulic ap
plicat
ions
Mac
hine t
ools
Hygien
ic ar
eas
Mobile
applic
atio
ns
Wat
er-b
ased
med
ia
Gases
Viscous m
edia
and m
edia
with
susp
ended
par
ticles
Hydro
static
leve
l mea
sure
men
t
Applications
PI -1...25 -25...125 /200
PG27/28 -1...25 -25...125
Unambiguous:Red / green colour change for the display (type PQ) or pointerdisplay with LED ring (type PG).
Simple:Setting via sensor menu or viaIO-Link (type PQ3).
Flexible:Analogue output, switching output and IO-Link (type PQ3).
4
For industrialapplications
Type PG pressuresensor
Optimum legibilitydue to the electro-nic pointer display.
Rotatable displaywith LED bargraph for switchpoint indication.
Display of thetrend or of the minimum and maximum values.
Output functionsprogrammable via LED displayand optical touchfields.
Factory settingmeasuring rangerelative pressure
[bar]
Process connection
G 1/2 maleOrder no.
0...400 PG2450
0...250 PG2451
0...100 PG2452
0...25 PG2453
0...10 PG2454
0...4 PG2455
0...2,5 PG2456
-1...1 PG2409
0...1 PG2457
0...0.25 PG2458
0...0.1 PG2489
1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable
Type PQ pressuresensor
Ideal for measur -ing compressedair.
Two-colour LEDdisplay for immediate statusdetection.
Moisture-proof silicon measuringcell.
Easy installationusing integratedmounting holesand accessories.
IO-Link (typePQ3xxx).
Pressure sensors with displayfor industrial applications
AccessoriesProcessadapterspages 18 - 19
5
Measuring rangerelative pressure
[bar]
Order no.Measuring rangerelative pressure
[bar]
2 switching outputs DC PNPrelative pressure
Order no.
1 switching output and 1 ana-logue output 4...20 mA, relativepressure, differential pressure
-1...10 PQ7834In
du
stri
alap
plic
atio
ns
wit
hd
isp
lay
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
-1...1 PQ7809
-1...10 PQ3834
-1...1 PQ3809
6
Type PN pressuresensor
Programmable2-colour display,clearly visibleswitch-point LEDs.
Captive laser typelabel.
IO-Link.
Robust:The ideal measuring cell forevery pressure range.
Red - green ranges:“Good ranges” or switchingstates can be identified quicklyvia the display colour.
Quick setting:Easy to use via 3 pushbuttons.
Optimum orientation:Process connection rotatable byapprox. 345°.
Universal application areas:High overload protection andprotection rating IP67 in pressureranges of -1...600 bar.
For industrialapplications
Factory settingmeasuring rangerelative pressure
[bar]
Process connection
G 1/4 female
Order no.
G 1/4 male
Order no.
G 1/4 female
Order no.
G 1/4 male
Order no.
Process connection
2 switching outputs 1 switching output and1 analogue output4...20 mA / 0...10 V
Measuring cell metal
0...600 PN7160 PN7560 PN3160 PN3560
Measuring cell ceramics
0...100 PN7092 PN7592 PN3092 PN3592
0...25 PN7093 PN7593 PN3093 PN3593
0...10 PN7094 PN7594 PN3094 PN3594
0...2.5 PN7096 PN7596 PN3096 PN3596
0...1 PN7097 PN7597 PN3097 PN3597
0...0.25
-1...1 PN7099 PN7599
-1...0 PN3129 PN3529
-0.5...0.5
0...400 PN7070 PN7570 PN3070 PN3570
0...250 PN7071 PN7571 PN3071 PN3571
7
Pressure sensors with displayfor industrial applications
Ind
ust
rial
app
licat
ion
s w
ith
dis
pla
y
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
AccessoriesProcessadapterspages 18 - 19
G 1/4 female
Order no.
G 1/4 male
Order no.
Process connection
2 switching outputsor 1 switching output
and 1 analogue output4...20 V / 0...10 V,
scalable
PN2160 PN2560
PN2092 PN2592
PN2093 PN2593
PN2094 PN2594
PN2096 PN2596
PN2097 PN2597
PN2098 PN2598
PN2099 PN2599
PN2169 PN2569
PN2070 PN2570
PN2071 PN2571
Type PA pressuretransmitter
Pressure transmit-ters with fixedmeasuring range.
High resistance tooverload due toceramic measuringcell.
Space-saving:Compact sensors without display.
Simple:Pressure transmitters with fixedranges; pressure sensors to beset via setting ring (type PK) orvia IO-Link (type PV).
Focussed:Ideal for industrial applications,such as hydraulic applications.
AccessoriesProcessadapterspages 18 - 19
8
For industrialapplications
Measuring rangerelative pressure
[bar]
Process connection
G 1/4 female
Order no.
G 1/4 male
Order no.
G 1/4 female
Order no.
Analogue output 4...20 mA 0...10 V
0...600 PA3060 PA9060
0...400 PA3020 PA9020
0...250 PA3021 PA3521 PA9021
0...100 PA3022 PA3522 PA9022
0...25 PA3023 PA3523 PA9023
0...10 PA3024 PA3524 PA9024
0...2.5 PA3026 PA3526 PA9026
-1...1 PA3509
-1...0 PA3029 PA9029
0...1 PA3027 PA9027
0...0.25 PA3028 PA3528 PA9028
0...0.1 PA3589
Type PK pressuresensor
Easy switch pointadjustment viatwo setting ringsallowing optimumread-out.
Mechanical lockingprevents inadver-tent switch pointmanipulation.
Stainless steelmeasuring cellwithout any seals.
Pressure sensors without displayfor industrial applications
9
Ind
ust
rial
app
licat
ion
s w
ith
dis
pla
y
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
Measuring rangerelative pressure
[bar]
2 x NO 1 x NO 2 switching outputs NC / NOcomplementary
Order no. Order no. Order no.
0...400 PK7520 PK5520 PK6520
0...250 PK7521 PK5521 PK6521
0...100 PK7522 PK5522 PK6522
0...25 PK7523 PK5523 PK6523
0...10 PK7524 PK5524 PK6524
Type PV pressuresensor
Programmablepressure sensorwith switchingoutputs.
Stainless steelmeasuring cellwithout any seals.
IO-Link.
Measuring rangerelative pressure
[bar]
2 switching outputs
Order no.
0...400 PV7000
0...250 PV7001
0...100 PV7002
0...60 PV7023
0...25 PV7003
0...10 PV7004
Available as of December 2016
Compact:Pressure transmitters withoutdisplay and with analogueoutput.
Robust:Stainless steel measuring cellwithout any seal.
Application-specific:Designs for level measurement(type PS), absolute pressuremeasurement (type PT05) andgeneral pressure measurement(type PT / PU).
10
Type PSsubmersible pres-sure transmitter
For level measure-ment.
PUR or FEP cablefor high resistanceto media.
Version withATEX approval forgroup I cat. M1and group II cat.1G and 1D.
Pressure compen-sation via inter nally vented cable.
Measuring rangerelative pressure
[mbar]
Cable
[m]
Order no.
For standard applications, CE approval
0.25 PUR, 5 PS3208
For high resistance to media, CE approval
0.25 FEP, 5 PS4208
For hazardous areas, CE, Ex, GL approvals
0.25 FEP, 5 PS308A
0.6 FEP, 10 PS307A
1 FEP, 15 PS317A
0.25 FEP, 10 PS4408
0.6 FEP, 10 PS4407
0.6 FEP, 20 PS4506
1 FEP, 15 PS4417
1 FEP, 30 PS4607
0.6 PUR, 10 PS3407
0.6 PUR, 15 PS3427
0.6 PUR, 30 PS3607
1 PUR, 15 PS3417
1 PUR, 30 PS3617
For industrialapplications
Type PU / PT pres-sure transmitter
Pressure transmit-ters with fixedmeasuring range.
Very fast responsetime of 1 ms.
Stainless steelmeasuring cellwithout any seal.
Pressure sensors without displayfor industrial applications
11
Ind
ust
rial
app
licat
ion
s w
ith
dis
pla
y
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
Measuring rangerelative pressure
[bar]
Order no. Order no.
Analogue output 4...20 mA 0...10 V
0...600 PU5460
0...400 PU5400
0...250 PU5401
0...160 PU5412
0...100 PU5402
0...60 PU5423
PT5460
PT5400
PT5401
PT5412
PT5402
PT5423
0...40 PU5443PT5443
0...25 PU5403PT5403
0...16 PU5414PT5414
0...10 PU5404PT5404
0...6 PU5415PT5415
-1...10 PT5494
Type PT pressuretransmitter
For absolutepressure measure-ment.
Transmitter withfixed measuringrange.
Stainless steelmeasuring cellwithout any seal.
Measuring rangeabsolute pressure
[bar]
Order no.
0...10 PT0504
0...4 PT0505
0...1.6 PT0517
0...1 PT0507
Analogue output 4...20 mA
AccessoriesProcessadapterspages 18 - 19
Compact:Pressure transmitters withoutdisplay and with analogueoutput.
Robust:Stainless steel measuring cellwithout any seal; shock andvibration resistance.
Flexible:Deutsch, AMP or M12 connector.
Temperature-resistant:-40…125 °C medium temperature.
Fast:Response time 2 ms.
Application-specific:Ideal for use in mobile hydraulicapplications.
12
Systems formobile machines
Type PU / PTpressure trans-mitter
For mobileapplications.
Processconnection
Measuring rangerelative pressure
[bar]
Order no. Order no. Order no.
Analogue output 4...20 mA
M12 DEUTSCH AMP
G 1/4 male
0...600 PT5560 PT5760 PT5660
Analogue output 0...10 V
G 1/4 male
0...600 PU5560 PU5760 PU5660
0...400 PU5500 PU5700 PU5600
0...250 PU5501 PU5701 PU5601
0...100 PU5502 PU5702 PU5602
0...25 PU5503 PU5703 PU5603
0...10 PU5504 PU5704 PU5604
0...400 PT5500 PT5700 PT5600
0...250 PT5501 PT5701 PT5601
0...100 PT5502 PT5702 PT5602
0...25 PT5503 PT5703 PT5603
0...10 PT5504 PT5704 PT5604
13
Ind
ust
rial
app
licat
ion
s w
ith
dis
pla
y
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
Pressure sensors without displayfor mobile applications
AccessoriesProcessadapterspages 18 - 19
Technical data
and prices?
www.ifm.com
Hygienic:Ingress resistance, materials andapprovals comply with hygienicrequirements.
Robust:Overload-resistant ceramic-capacitive measuring cells withlong-term stability.
Versatile:Variable process connections.
Precise:High total accuracy of 0.2 %.
Suitable for CIP/SIP:High temperature resistance andelectronic temperature compen-sation.
For hygienic areasand viscous media
Type PGpressure sensor
Optimum legibilitydue to the electro-nic pointer display.
Rotatable displaywith LED bargraph for switchpoint indication.
Display of thetrend or of theminimum andmaximum values.
Output functionsprogrammablevia LED displayand optical touchfields.
14
Factory settingmeasuring rangerelative pressure
[bar]
Process connection
G 1 male Aseptoflex VarioOrder no.
G 1 A sealing coneOrder no.
0...25 PG2793 PG2893
0...10 PG2794 PG2894
0...4 PG2795 PG2895
0...2.5 PG2796 PG2896
-1...1 PG2799 PG2899
0...1 PG2797 PG2897
0...0.25 PG2798 PG2898
0...0.1 PG2789 PG2889
1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable
Ind
ust
rial
app
licat
ion
s w
ith
dis
pla
y
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
Pressure sensors with analogue displayfor hygienic applications
15
Order now?
In the e-shop at
www.ifm.com
AccessoriesProcessadapterspages 18 - 19
Hygienic:Ingress resistance, materials andapprovals comply with hygienicrequirements.
Robust:Overload-resistant ceramic-capacitive measuring cells withlong-term stability.
Versatile:Variable process connections.
Precise:High total accuracy of 0.2 %.
Suitable for CIP/SIP:High temperature resistance andelectronic temperature compen-sation.
For hygienic areasand viscous media
16
Factory settingmeasuring rangerelative pressure
[bar]
Process connection
G 1 male Aseptoflex VarioOrder no.
G 1 A sealing coneOrder no.
0...25 PI2793 PI2893
1 switching output and 1 analogue output 4...20 mA / 20...4 mA
0...10 PI2794 PI2894
0...4 PI2795 PI2895
0...2.5 PI2796 PI2896
-1...1 PI2799 PI2899
0...1 PI2797 PI2897
0...0.25 PI2798 PI2898
0...0.1 PI2789 PI2889
Factory settingmeasuring rangerelative pressure
[bar]
Process connection
Clamp 1.5"Order no.
Clamp 2"Order no.
0...25 PI2203 PI2303
0...10 PI2204 PI2304
0...4 PI2205 PI2305
0...2.5 PI2206
PI2209
PI2306
-1...1 PI2309
PI22070...1 PI2308
Type PI pressuresensor
Programmableanalogue outputin 2-wire opera-tion.
Additionalswitching out-put in 3/4-wireoperation.
IO-Link.
PI type pressuretransmitter
Pressure trans-mitters with clampprocess connection.
For mediumtemperaturesup to 200 °C.
1 switching output and 1 analogue output 4...20 mA / 20...4 mA
Ind
ust
rial
app
licat
ion
s w
ith
dis
pla
y
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
Pressure sensors with displayfor hygienic applications
17
Order now?
In the e-shop at
www.ifm.com
AccessoriesProcessadapterspages 18 - 19
G 1/4 G 1/4 high-grade stainless steel (316L/1.4404) FKM
PN, PAwith
internalthread
E30143
Deviceconnection
Processconnection
Material For sensortype
Orderno.
Process adapters
G 1/4 G 1/2 stainless steel (303/1.4305), FPM (Viton) E30050
G 1/4 G 1/2 stainless steel (303/1.4305), FPM (Viton) E30000
G 1/4 G 1/2 high-gr. stainl. steel (316L/1.4404) FPM (Viton) E30002
G 1/4 M20 x 1.5 stainless steel (303/1.4305), FPM (Viton) E30010
G 1/4 SAE 7 / 16-20 high-gr. stainl. steel (316L/1.4404) FPM (Viton) E30087
G 1/4 1/4" NPT high-grade stainless steel (316Ti/1.4571) E30058
G 1/4 1/2" NPT high-grade stainless steel (316L/1.4404) E30133
G 1/4 DN16 stainless steel (304/1.4301) E30065
G 1/4 R 1/4 1.0718 (12L13) E30427
Accessories
For industrialapplications
For hygienic areasand viscous media
18
Adapters for industrial applications
Damping screw
PN
E30419
Description For sensortype
Order no.
Accessories for industrial applications
Protective cover E30420
Angle bracket E30421
Label tag E30422
PN, PK, PA35xxDamping screw for sensors with M5 internal thread E30057
Syphon G 1/4 E30140
Syphon G 1/2 E30141
PKProtective cover E30094
PS
Cable clamp fastener E30399
Filter element E30400
Splitter box with ventilation and terminal block E30401
Additional weight E30402
PQ
Connector QS-G 1/8-6 for tube with Ø 6 mm E30076
Connector QS-G 1/8-8 for tube with Ø 8 mm E30077
DIN rail clip E37340
Adapter R 1/8 - R 1/8 rotatable E37350
IO-Link interface E30396
Parameter setting tools
USB IO-Link master E30390
Memory plug, parameter memory for IO-Link sensors E30398
LINERECORDER SENSOR (USB stick) QA0001
G 1/4 G 1/2 high-grade stainless steel (316Ti/1.4571),FPM (Viton) E30135
Sensorswith G 1/4"
externalthread
Deviceconnection
Processconnection
Sealing Order no.with leakage port
For sensortype
Order no.Process adapters
Process adapters and mounting accessoriesfor pressure sensors
19
Ind
ust
rial
app
licat
ion
s w
ith
dis
pla
y
Mo
bile
app
licat
ion
s
Hyg
ien
icap
plic
atio
ns
wit
han
alo
gu
e d
isp
lay
Hyg
ien
icap
plic
atio
ns
wit
hd
isp
lay
Acc
esso
ries
Ind
ust
rial
app
licat
ion
sw
ith
ou
t d
isp
lay
High-grade stainless steel adapter (316L / 1.4435) for hygienic applications
G 1 maleAseptoflex
Vario
Clamp 1 - 1.5"Sealing ring
PG27xx,PI27xx
G 1 male sealing cone
PG28xx,PI28xx
E33201 E33208
Clamp 1 - 1.5" Metal-to-metal E33601 –
Pipe fittingDN40 (1.5") Metal-to-metal E33612 –
Varivent type NDN40...DN150
(1.5...6") D = 68Metal-to-metal E33622 –
Metal-to-metal E33701 –
High-grade stainless steel welding adapters for hygienic applications
G 1 maleAseptoflex
Vario
Welding adapterD50 Sealing ring PG27xx,
PI27xx
G 1 malesealing cone
Welding adapterD50
PG28xx,PI28xx
E30122 E30130
Metal-to-metal E30013 –
Sealing ring E30072 –
Adapter accessories for hygienic applications
G 1 maleAseptoflex
Vario
Sealing plug Sealing ringPG27xx,PI27xx
G 1 malesealing cone Sealing plug PG28xx,
PI28xx
E30128 –
FKM O-ring E30123
PEEK ring E30124
E30070
Clamp 2"Sealing ring E33202 E33209
Metal-to-metal E33702 –
Pipe fittingDN32 (1.25")
Sealing ring E33211 –
Metal-to-metal E33711 –
Pipe fittingDN40 (1.5")
Sealing ring E33212 –
Metal-to-metal E33712 –
Pipe fittingDN50 (2")
Sealing ring E33213 –
Metal-to-metal E33713 –
Varivent type FDN25 (1") D = 50
Sealing ring E33221 E33228
Metal-to-metal E33721 –
Varivent type NDN40...DN150
(1.5...6") D = 68
Sealing ring E33222 E33229
Metal-to-metal E33722 –
SMS DN40 (1.5") Metal-to-metal E33731 –
SMS DN50 (2") Metal-to-metal E33732 –
DRD flange D65 Sealing ring E33242 –
Universal adapterRd 52 Sealing ring E33340 –
DIN11864DN/OD33.7 Sealing ring E33304 –
G 1/2 Sealing ring E30131 –
Want to find
the suitable socket?
www.ifm.com
AdapterAccessories
Visit our website:
www.ifm.com
ifm electronic gmbhFriedrichstraße 145128 EssenTel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200E-mail [email protected]
Over 70 locations worldwide –at a glance at www.ifm.com
Position sensors
Sensors formotion control
Industrial imaging
Safety technology
Process sensors
Condition monitoringsystems
Industrialcommunication
Identification systems
Systems formobile machines
Connectiontechnology
Overviewifm product range:
Accessories
ifm a
rtic
le n
o. 7
8001
977
· We
rese
rve
the
right
to
mak
e te
chni
cal a
ltera
tions
with
out
prio
r no
tice.
· Pr
inte
d in
Ger
man
y on
non
-chl
orin
e bl
each
ed p
aper
. 05
/16