Level sensors from ifm

24
The right choice for your application. Level sensors from ifm. www.ifm.com Level sensors years W A R R A N T Y o n i f m p r o d u c t s

Transcript of Level sensors from ifm

Page 1: Level sensors from ifm

The right choicefor your application.

Level sensorsfrom ifm.

ww

w.if

m.c

om

Leve

l sen

sors

years

W

ARRANTY

on ifm products

Page 2: Level sensors from ifm

2

Systems for level monitoring.The optimum solution for every requirement.

Impedancespectroscopy

Point level

Continuouslevel measurement

Capacitivein contact withthe medium

Capacitivewithout contact

Capacitivecontinuous

Guidedwave radar

Hydrostatic

Photoelectric

Accessories

Alternative tovibrating forksSuppression ofresidues and foam

For contact withthe mediumOverflow protectionLeakage monitoring

For the detectionthrough non-metallictanks

For applicationson hydraulic andcoolant tanks

For industrial andhygienic applications

For industrial andhygienic applicationsOn tanks andin free-flowingwaterways

For long distanceswithout contactto the medium

Adapters forlevel sensors inindustrial andhygienic applications

Page 3: Level sensors from ifm

3

Imp

edan

cesp

ectr

osc

op

y

Senso

r typ

e

Max

. mea

surin

g range [

cm]

Analogue o

utput

4 - 5LMT –

EHEDG3A

FDAEC1935WHGATEX

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

6 - 7LI – WHG

Cap

acit

ive

wit

ho

ut

con

tact

8 - 9KG, KI, KQ –

Cap

acit

ive

con

tin

uo

us

10-11LK, LT 73 WHG

Gu

ided

wav

e ra

dar

12-15LR 200

EHEDG3A

FDAEC1935WHG

Hyd

rost

atic

16-19PG, PI,PA, PS, PN –

EHEDG3A

FDAEC1935ATEX

Pho

toel

ectr

ic

20-21O1D 980

Acc

esso

ries

22-23

Switc

hing o

utput

Approva

ls

Page 4: Level sensors from ifm

G 1/2 11 LMT100 LMT191 –

Reliable detection:Suppression of residues,splashing water or foam.

Better than a tuning fork:No mechanical components, fullycompatible regarding installationand function.

Immediately ready for use:Factory settings for themost common media.

Adaptable using IO-Link:Adaptation to and differentiationof media configurable.

More transparency:Read process values to optimisethe application.

Hygienic design:High-grade stainless steelhousing with PEEK sensor tipand maintenance-free sealingconcept.

4

For hygienic areasand viscous media

Type LMTlevel sensor

Flexible mountingthanks to orienta-tion-independentinstallation.

Shock and vibra-tion resistant in arobust stainlesssteel housing.

Hygienic approvalsEHEDG, 3A andFDA.

Versions availableas overflowprotection.

Complementaryswitching outputs.

Processconnection

Installationlength[mm]

Order no. Order no. Order no.

Approvals

Preset to aqueous media

Hygienic WHG* ATEX

G 1/2 38 LMT102 LMT192 –

G 1/2 153 LMT104 LMT194 –

G 1/2 253 LMT105 LMT195 –

G 3/4 28 LMT202 LMT292 –

G 1 38 LMT302 LMT392 –

G 1/2 11 LMT110 – –

Preset to oils, fats, powder

G 1/2 11 LMT121 – –

Preset to sugary media

G 1/2 11 – – LMT01A

G 1/2 153 – – LMT03A

G 1/2 253 – – LMT04A

* German Federal Water Act

Page 5: Level sensors from ifm

Manholemonitoring

Fullmonitoring

Emptymonitoring

Run-dryprotection

Point level detection with impedance spectroscopy.The reliable and fast alternative to tuning forks.

5

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

esFor adapterssee pages22 - 23

Page 6: Level sensors from ifm

Ready in no time:Easy mounting adjustment.

Flexible:Normally closed / normally openprogrammable.

Clear:Clearly visible indication ofthe switch points.

Variable use:Installation depths of132 to 737 mm.

Certified:Approval as overflow protectionor leakage sensor to theGerman Federal Water Act.

For industrialapplications

Type LIpoint level sensor

Optimised for usein hydraulic oilsand coolants.

Modular mount-ing concept forflexible use.

It only takes onepush of a buttonto adjust andset the outputfunction.

6

132 0...35 (0...65)1) 0...65 LI5141

Rod length

[mm]

Watertemperature

[°C]

Oiltemperature

[°C]

Order no.

1 switching output, normally closed / normally open programmable

1 switching output, normally closed

Overflow protection to the WHG*

273 0...35 (0...65)1) 0...65 LI5142

481 0...35 (0...65)1) 0...65 LI5143

737 0...35 (0...65)1) 0...65 LI5144

132 0...35 0...65 LI2141

273 0...35 0...65 LI2142

481 0...35 0...65 LI2143

Leakage sensor to the WHG*

132 0...35 0...65 LI2241

273 0...35 0...65 LI2242

481 0...35 0...65 LI2243

* German Federal Water Act1) in connection with climatic tube, see accessories page 23

Page 7: Level sensors from ifm

Capacitive point level.In contact with the medium –protection against overflow and leakage.

7

Order now.

0800 16 16 16 4 or

in the e-shop at

www.ifm.com

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

esFor adapterssee pages22 - 23

Page 8: Level sensors from ifm

Convenient:Many functions such as binaryswitching output, timer functionsas output, damping function aswell as NC / NO function.

Communicative:Process values, parameter settingdata and diagnostic informationcan be transmitted via IO-Link.

Easy:Parameter setting via IO-Linkbefore installation, as an alter-native also via pushbuttons onthe sensor.

Repeatable:Simple parameter setting ofmany sensors via “copy & paste”in the LINERRECORDER SENSORsoftware or via a memory plug.

Clear:Clearly visible LEDs indicate theswitching status.

Type KG / KIpoint level sensors

Capacitive sensorsin cylindrical M18or M30 housing.

8

For industrialapplications

8 nf Cable • KG50691)

Sensingrange[mm]

Connection Teachfunction

Order no.

DC PNP

M18 housing, plastic

15 nf M12connector – KI5052

M30 housing, plastic

20 nf M12connector • KI5083

8 f M12connector • KI5085

M30 housing, metal

15 nf M12connector • KI5087

8 nf M12connector

– KG5057

• KG5071

12 nf M12connector • KG5066

1) Housing, white PPf: flush installation nf: non-flush installation

Page 9: Level sensors from ifm

9

Capacitive point level.Detection through non-metallic tank walls.

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

es

Sensingrange[mm]

Connection Order no.

DC PNP

12 nfCable 2 m KQ6002

Cable 10 m KQ6007

12 nf Cable plugM8 KQ6004

12 nf Cable plugM12 KQ6005

Type KQpoint level sensor

Capacitive sensorsin small plasticrectangularhousing.

Easy installationwith mountingadapters andfixing straps.

DC NPN

12 nf

12 nf

Cable 2 m KQ6006

Cable plugM12 KQ6016

DC PNP

12 nf

12 nf

Cable 2 m KQ5100

Cable plugM12 KQ5101

12 nf Cable plugM8 KQ5102

f: flush installation nf: non-flush installation

Page 10: Level sensors from ifm

Professional:For industrial applications.

Manifold:Versions with 2 or 4 switchingoutputs or analogue output4...20 mA / 0...10 V.

Safe:Type LK12 with approval asoverflow protection.

Combined:Type LT for level and temperaturemonitoring.

Type LKlevel sensor

Display and hand-ling directly onthe unit.

As an option withanalogue outputor up to fourswitching outputs.

Suitable for oiltemperatures upto 70 °C.

Versions to theGerman FederalWater Actavailable.

For industrialapplications

264 LK1022

Rod length

[mm]

Version Order no.

2 switching outputs

1 switching output, 1 analogue output 4...20 mA, 0...10 V

472 LK1023

728 LK1024

264 WHG* LK1222

472 WHG* LK1223

728 WHG* LK1224

10

264 LK3122

472 LK3123

728 LK3124

2 switching outputs

264Automatic

medium detection

LK7022

472 LK7023

728 LK7024

4 switching outputs

264 LK8122

472 LK8123

728 LK8124

* German Federal Water Act

Page 11: Level sensors from ifm

Continuous capacitive level measurement.For applications on hydraulic and coolant tanks.

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

es

Type LTlevel sensor

For level andtemperature.

Suitable for oils upto 70 °C.

11

264 For level and temperature LT8022

Rod length

[mm]

Version Order no.

2 x 2 switching outputs level / temperature

472 For level and temperature LT8023

728 For level and temperature LT8024

For adapterssee pages22 - 23

Page 12: Level sensors from ifm

Versatile:Modular sensor concept, flexiblein use.

Variable:Rods can be cut to size asrequired.

Reliable:Measuring principle independentof temperature influences.

Optional outputs:Versions with two or fourswitching outputs or analogueoutput 4...20 mA / 0...10 V.

Selectable:Designs with and withoutdisplay.

Type LRlevel sensor

Display and hand-ling on the unit orvia IO-Link.

As an option withanalogue outputor up to fourswitching outputs.

Rod lengthsfreely selectablebetween10...200 cm.

Versions to theGerman FederalWater Actavailable.

G 3/4 male LR2050

Processconnection

Order no.

2 switching outputs or 1 switching output and1 analogue output 4...20 mA

G 3/4 male LR7000

3/4" NPT LR7300

Processconnection

Order no.

2 switching outputs

G 3/4 male LR9020

Processconnection

Order no.

1 analogue output 4...20 mA or 0...10 V

G 3/4 male LR3000

3/4" NPT LR3300

1 switching output and1 analogue output 4...20 mA or 0...10 V

For industrialapplications

For hygienic areasand viscous media

12

Type LRlevel transmitter

For industrialapplications.

Analogue outputscalable4...20 mA / 0...10 V.

Protection ratingIP 69K.

Easily adjustablevia IO-Link.

G 3/4 male LR8000

3/4" NPT LR8300

4 switching outputs

G 3/4 male LR80101)

4 switching outputs / WHG*

* German Federal Water Act1) Only in connection with rod and coaxial pipe,

see page 14

Page 13: Level sensors from ifm

Continuous level measurement with guided microwave.For industrial and hygienic applications.

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

esAseptoflex Vario G1 LR2750

Processconnection

Order no.

2 switching outputs or 1 switching output and1 analogue output 4...20 mA

Type LR27hygienic levelsensor

Display and hand-ling on the unit orvia IO-Link.

Medium tempera-ture -40...150 °C.

Pressure-resistantup to 40 bar.

Rod lengthsof 15...200 cmselectable.

13

For rods andcoaxial pipessee pages14 - 15

For adapterssee pages22 - 23

Page 14: Level sensors from ifm

G 3/4

G 3/4

14

For industrialapplications

For hygienic areasand viscous media

700 E43205

Length

[mm]

Order no.

Level sensor3/4" NPTType LR3300Type LR7300Type LR8300

800 E43337

1000 E43207

1200 E43208

1400 E43209

1600 E43210

2000 E433532)

2) Only for type LR2050 sensor

150 E43225

Length

[mm]

Order no.

210 E43351

240 E43203

265 E43352

300 E43226

450 E43204

500 E43227

Rods for LR levelsensors with 3/4"NPT oder G 3/4male, industrialapplications

Material:high-gradestainless steel(1.4404 / 316L)

1) Only in connectionwith rod andcoaxial pipe

Level sensorG 3/4 maleType LR2050Type LR3000Type LR7000Type LR8000Type LR80101)

Type LR9020

150 E43230

Processconnection

Length

[mm]

Order no.

210 E43354

240 E43211

265 E43355

300 E43228

450 E43212

500 E43229

700 E43213

800 E43336

1000 E43214

1200 E43215

1400 E43216

1600 E43217

2000 E433562)

700, slotted E43333

1200, slotted E43334

2) Only for type LR2050 sensor

Coaxial pipes forLR level sensorswith G 3/4 male,industrialapplications

Material:high-gradestainless steel(1.4301 / 304)

Page 15: Level sensors from ifm

15

Continuous level measurementwith guided microwave.Rods and coaxial pipes.

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

es

3/4" NPT

450 E43218

Processconnection

Length

[mm]

Order no.

700 E43219

1000 E43220

1200 E43223

1400 E43224

1600 E43221

150 E43345

Length

[mm]

Order no.

300 E43346

500 E43340

700 E43347

1000 E43341

1500 E43348

2000 E43342

Type LR2750hygienic levelsensor

Rods for levelsensor typeLR2750, hygienicapplications

Material:high-gradestainless steel(1.4404 / 316L)

For a wide

selection of other

accessories visit

www.ifm.com

For adapterssee pages22 - 23

Page 16: Level sensors from ifm

16

Robust:Overload-protected measuringprinciples with a good long-termstability.

Versatile:Compact sensors with andwithout display.

Precise:Ceramic-capacitive andpiezoresistive measuring cells.

For industrialapplications

Type PApressure sensor

2-wire pressuretransmitter.

Ceramic-capacitivemeasuring cell.

G 1/4 female 0...1000 0...1000 PA9027

Processconnection

Relative pressuremeasuring range

[mbar]

Relative pressuremeasuring range

[mbar]

Order no.

Analogue output 4...20 mA Analogue output 0...10 V

Type PSsubmersiblepressuretransmitter

PUR or FEP cablefor high resistanceto media.

Version with ATEXapproval forgroup I cat. M1and group IIcat. 1G and 1D.

Pressure compen-sation via inter-nally vented cable.

Order no.

PA3027

G 1/4 female 0...250 0...250 PA9028PA3028

G 1/4 male 0...250 PA3528

G 1/4 male 0...100 PA3589

0.25 FEP, 5 PS4208

Relative pressuremeasuring range

[mbar]

Cable

[m]

Order no.

For high resistance to media, CE approval

0.6 FEP, 10 PS4407

1 FEP, 15 PS4417

0.25 FEP, 5 PS308A

For hazardous areas, CE, Ex, GL approvals

0.6 FEP, 10 PS307A

1 FEP, 15 PS317A

0.25 PUR, 5 PS3208

Relative pressuremeasuring range

[mbar]

Cable

[m]

Order no.

For standard applications, CE approval

0.6 PUR, 10 PS3407

0.6 PUR, 15 PS3427

0.6 PUR, 30 PS3607

1 PUR, 15 PS3417

1 PUR, 30 PS3617

Page 17: Level sensors from ifm

17

Continuous hydrostatic level measurementin industrial applications.For use on tanks and in free-flowing waterways.

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

es

Processconnection

Relative pressuremeasuring range

[mbar]

Relative pressuremeasuring range

[mbar]

Order no.

2 switching outputs 1 switching output and1 analogue outp. 4...20 mA / 0...10 V

Order no.

G 1/4 female 0...1000 0...1000 PN3097PN7097

G 1/4 male 0...1000 0...1000 PN3597PN7597

2 switching outputs or 1 switching output and1 analogue output 4...20 mA / 0...10 V, scalable

G 1/4 female 0...1000 -12.5...250 PN2098PN2097

G 1/4 male 0...1000 -12.5...250 PN2598PN2597

G 1/4 female -500...500 PN2169

G 1/4 male -500...500 PN2569

Type PN pressuresensor

Programmable2-colour display,clearly visibleswitch-point LEDs.

Rotatable processconnection.

Operation via3 raised push-buttons.

Type PGpressure sensor

Optimumlegibility due tothe electronicpointer display.

Rotatable display.

Display of thetrend or of theminimum andmaximum values.

Processconnection

Relative pressuremeasuring range

[mbar]

1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable

Order no.

G 1/2 male 0...1000 PG2457

G 1/2 male 0...250 PG2458

G 1/2 male 0...100 PG2489

For adapterssee pages22 - 23

Page 18: Level sensors from ifm

18

G1 maleAseptoflex Vario

-0.01...0.1 PG2789

Hygienic:Ingress resistance, materialand approvals according tohygiene requirements.

Robust:Overload-resistant ceramic-capacitive measuring cells withlong-term stability.

Versatile:Variable process connections.

Precise:High overall accuracy (0,2 %).

For CIP / SIP applications:High temperature resistanceand electronic temperaturecompensation.

For hygienic areasand viscous media

Type PGpressure sensor

Optimumlegibility due tothe electronicpointer display.

Rotatable display.

Display of thetrend or of theminimum andmaximum values.

Processconnection

Measuringrange[bar]

Order no.

1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable

-0.01...0.25 PG2798

-0.05...1 PG2797

-1...1 PG2799

G1 malesealing cone

-0.01...0.1 PG2889

-0.01...0.25 PG2898

-0.05...1 PG2897

-1...1 PG2899

Page 19: Level sensors from ifm

19

Continuous hydrostatic level measurementin hygienic areas.For applications on large tanks.

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

esG1 male

Aseptoflex Vario

-0.01...0.1 PI2789

Type PIpressure sensor

Programmableanalogue outputin 2-wireoperation.

Additionalswitching outputin 3/4-wireoperation.

Processconnection

Measuringrange[bar]

Order no.

1 switching output and1 analogue output 4...20 mA / 20...4 mA

-0.01...0.25 PI2798

-0.05...1 PI2797

-1...1 PI2799

G1 malesealing cone

-0.01...0.1 PI2889

-0.01...0.25 PI2898

-0.05...1 PI2897

-1...1 PI2899

For adapterssee pages22 - 23

Page 20: Level sensors from ifm

20

Longest distances:Photoelectric level detectionof bulk materials and non-transparent liquids, for levelsup to 9.8 m.

Convenient:Scalable detection range withwindow function.

Reliable detection:Can be used in applicationsneeding background suppression.

Flexible mounting:Extensive range of fixingcomponents.

For industrialapplications

0.2...9.8 M12connector < 15 x 15

Measuringrange

[m]

Connection Light spot diameter

[mm]

2 switching outputs or 1 switching output and1 analogue output 4...20 mA / 0...10 V, scalable

Type O1D photo-electric distancesensor with timeof flight tech-nology

Resistant to extra-neous light up to100,000 lux.

2 switching out-puts; one outputcan be configuredas analogueoutput.

4-digit alpha-numeric display.

Order no.

O1D300

Order now.

0800 16 16 16 4 or

in the e-shop at

www.ifm.com

Page 21: Level sensors from ifm

21

Continuous photoelectric level measurement.For long distances without contact to the medium.

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

es

Accessories

No. Version Order no.

1 Mounting brackethigh-grade stainless steel (1.4404 / 316L) E21120

2 Clamp mounting set for rod mountØ 12 mm E2D101

3 Mounting adapter withprocess connection G1 male E21224

4 Mounting rod, 100 mm, Ø 12 mm,M10 thread, stainless steel E20938

5 Mounting rod, 200 mm, Ø 12 mm,M10 thread, stainless steel E20940

6 Cube for mounting on an aluminium profile,M10 thread, stainless steel E20951

Mounting accessories

7Protective cover, glass E21171

Device protection

8 Cooling box E21248

Protective cover, PMMA E21133

1

8

7

654

3

2

Page 22: Level sensors from ifm

E43315

E43309

E43310

E43311

E43312

1

2

Clamp 1 - 1.5"

Processconnection

No. Order no. Order no. withleakage port

E33401

Mounting adapters for industrial and hygienic applications

22

For industrialapplications

For hygienic areasand viscous media

Clamp 2" E33402

Pipe fitting DN25 E43304

Pipe fitting DN40 E43305

3Varivent type F DN25, D = 50 E43306

Varivent type N DN40...150, D = 68 E43307

4 Screw-in adapter G 1 E43303

Screw-in adapter G 3/4 E43302

5 Pipe fitting DN25 SMS E33430

Sealing plug G 1/2 E43308

Screw-in adapter 3/4" NPT E43313

6 Collar G 1/2 Ø 45 mm E30056

Welding adapters for industrial and hygienic applications

7 Ball G 1/2 Ø 35 mm E30055

9 Long design G 1/2 Ø 50 mm E43319

10 Welding mandrel G 1/2 E43314

8For tanks G 1/2 Ø 30 mm E43300

For pipes G 1/2 Ø 29 mm E43301

11

T-piece DN25 E43316

T-pieces for industrial and hygienic applications

T-piece DN40 E43317

T-piece DN50 E43318

12Clamp adapter for type LMT1041) E43349

Variable clamp adapters

Clamp adapter for type LMT1051) E43322

1) Only in connection with G 1/2 female adapter

Adapters G 1/2for type LMT 1

2

3

45

6

7

8

9

10

11

12Adapters fortypes LR, LK

22

23

For a wideselection of otheraccessories visitwww.ifm.com

Page 23: Level sensors from ifm

16 –Flange DRD, D = 65 E33242

E33228

E3322915

Varivent type F DN25, D = 50 E33221

Varivent type N DN40...150, D = 68 E33222

E33208

E33209

E33304

23

Accessories.Adapters for level sensors inindustrial and hygienic applications.

Imp

edan

cesp

ectr

osc

op

y

Cap

acit

ive

inco

nta

ct w

ith

the

med

ium

Cap

acit

ive

wit

ho

ut

con

tact

Cap

acit

ive

con

tin

uo

us

Gu

ided

wav

e ra

dar

Hyd

rost

atic

Pho

toel

ectr

icA

cces

sori

es

13

14

Clamp 1 - 1.5"

Processconnection

No. Order no. Order no. withleakage port

E33201

Mounting adapters for industrial and hygienic applications

Clamp 2" E33202

Pipe fitting DN32 E33211

Pipe fitting DN50 E33213

Pipe fitting DN40 E33212

Universal process adapter Rd52 E33340

Pipe fitting DIN 11864-1 A-BS –

Adapters G1 male /Aseptoflex Variofor typesPG, PI, LR

E30130

17 Welding adapter Ø 50 mm E30122

Welding adapters for industrial and hygienic applications

Sealing plug E30128

No. Version Order no.

18 Mounting clamp Ø 16 mm E43000

19 Welding adapter Ø 50 mm E43002

Mounting adapters

21Climatic tube, 264 mm long E43100

Device protection

Climatic tube, 728 mm long E43102

Climatic tube, 472 mm long E43101

Mounting adapter G 3/4 E43003

20 Mounting adapter G 1 E43004

Mounting adapter 3/4" NPT E43012

Climatic tube, 132 mm long E43103

No. Version Order no.

22Flange plate 73 - 90 / G 3/4 E43201

Flange plate 65 - 80 / G 3/4 E43202

Mounting adapters

23 Protective cover E43910

Device protection

Find the

suitable socket:

www.ifm.com

13

14

15

16

17

18

19

20

21

Adapters fortypes LI, LK, LT

Page 24: Level sensors from ifm

Visit our website:

www.ifm.com

ifm electronic gmbhFriedrichstraße 145128 EssenTel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200E-mail [email protected]

Over 70 locations worldwide –at a glance at www.ifm.com

Position sensors

Sensors formotion control

Industrial imaging

Safety technology

Process sensors

Condition monitoringsystems

Industrialcommunication

Identification systems

Systems formobile machines

Connectiontechnology

Overviewifm product range:

Accessories

ifm a

rtic

le n

o. 7

8001

767

· We

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

· Pr

inte

d in

Ger

man

y on

non

-chl

orin

e bl

each

ed p

aper

. 11/

15