Level sensors from ifm
-
Upload
ifm-electronic-gmbh -
Category
Technology
-
view
323 -
download
3
Transcript of Level sensors from ifm
The right choicefor your application.
Level sensorsfrom ifm.
ww
w.if
m.c
om
Leve
l sen
sors
years
W
ARRANTY
on ifm products
2
Systems for level monitoring.The optimum solution for every requirement.
Impedancespectroscopy
Point level
Continuouslevel measurement
Capacitivein contact withthe medium
Capacitivewithout contact
Capacitivecontinuous
Guidedwave radar
Hydrostatic
Photoelectric
Accessories
Alternative tovibrating forksSuppression ofresidues and foam
For contact withthe mediumOverflow protectionLeakage monitoring
For the detectionthrough non-metallictanks
For applicationson hydraulic andcoolant tanks
For industrial andhygienic applications
For industrial andhygienic applicationsOn tanks andin free-flowingwaterways
For long distanceswithout contactto the medium
Adapters forlevel sensors inindustrial andhygienic applications
3
Imp
edan
cesp
ectr
osc
op
y
Senso
r typ
e
Max
. mea
surin
g range [
cm]
Analogue o
utput
4 - 5LMT –
EHEDG3A
FDAEC1935WHGATEX
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
6 - 7LI – WHG
Cap
acit
ive
wit
ho
ut
con
tact
8 - 9KG, KI, KQ –
–
–
–
Cap
acit
ive
con
tin
uo
us
10-11LK, LT 73 WHG
Gu
ided
wav
e ra
dar
12-15LR 200
EHEDG3A
FDAEC1935WHG
Hyd
rost
atic
16-19PG, PI,PA, PS, PN –
EHEDG3A
FDAEC1935ATEX
Pho
toel
ectr
ic
20-21O1D 980
Acc
esso
ries
22-23
Switc
hing o
utput
Approva
ls
G 1/2 11 LMT100 LMT191 –
Reliable detection:Suppression of residues,splashing water or foam.
Better than a tuning fork:No mechanical components, fullycompatible regarding installationand function.
Immediately ready for use:Factory settings for themost common media.
Adaptable using IO-Link:Adaptation to and differentiationof media configurable.
More transparency:Read process values to optimisethe application.
Hygienic design:High-grade stainless steelhousing with PEEK sensor tipand maintenance-free sealingconcept.
4
For hygienic areasand viscous media
Type LMTlevel sensor
Flexible mountingthanks to orienta-tion-independentinstallation.
Shock and vibra-tion resistant in arobust stainlesssteel housing.
Hygienic approvalsEHEDG, 3A andFDA.
Versions availableas overflowprotection.
Complementaryswitching outputs.
Processconnection
Installationlength[mm]
Order no. Order no. Order no.
Approvals
Preset to aqueous media
Hygienic WHG* ATEX
G 1/2 38 LMT102 LMT192 –
G 1/2 153 LMT104 LMT194 –
G 1/2 253 LMT105 LMT195 –
G 3/4 28 LMT202 LMT292 –
G 1 38 LMT302 LMT392 –
G 1/2 11 LMT110 – –
Preset to oils, fats, powder
G 1/2 11 LMT121 – –
Preset to sugary media
G 1/2 11 – – LMT01A
G 1/2 153 – – LMT03A
G 1/2 253 – – LMT04A
* German Federal Water Act
Manholemonitoring
Fullmonitoring
Emptymonitoring
Run-dryprotection
Point level detection with impedance spectroscopy.The reliable and fast alternative to tuning forks.
5
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
esFor adapterssee pages22 - 23
Ready in no time:Easy mounting adjustment.
Flexible:Normally closed / normally openprogrammable.
Clear:Clearly visible indication ofthe switch points.
Variable use:Installation depths of132 to 737 mm.
Certified:Approval as overflow protectionor leakage sensor to theGerman Federal Water Act.
For industrialapplications
Type LIpoint level sensor
Optimised for usein hydraulic oilsand coolants.
Modular mount-ing concept forflexible use.
It only takes onepush of a buttonto adjust andset the outputfunction.
6
132 0...35 (0...65)1) 0...65 LI5141
Rod length
[mm]
Watertemperature
[°C]
Oiltemperature
[°C]
Order no.
1 switching output, normally closed / normally open programmable
1 switching output, normally closed
Overflow protection to the WHG*
273 0...35 (0...65)1) 0...65 LI5142
481 0...35 (0...65)1) 0...65 LI5143
737 0...35 (0...65)1) 0...65 LI5144
132 0...35 0...65 LI2141
273 0...35 0...65 LI2142
481 0...35 0...65 LI2143
Leakage sensor to the WHG*
132 0...35 0...65 LI2241
273 0...35 0...65 LI2242
481 0...35 0...65 LI2243
* German Federal Water Act1) in connection with climatic tube, see accessories page 23
Capacitive point level.In contact with the medium –protection against overflow and leakage.
7
Order now.
0800 16 16 16 4 or
in the e-shop at
www.ifm.com
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
esFor adapterssee pages22 - 23
Convenient:Many functions such as binaryswitching output, timer functionsas output, damping function aswell as NC / NO function.
Communicative:Process values, parameter settingdata and diagnostic informationcan be transmitted via IO-Link.
Easy:Parameter setting via IO-Linkbefore installation, as an alter-native also via pushbuttons onthe sensor.
Repeatable:Simple parameter setting ofmany sensors via “copy & paste”in the LINERRECORDER SENSORsoftware or via a memory plug.
Clear:Clearly visible LEDs indicate theswitching status.
Type KG / KIpoint level sensors
Capacitive sensorsin cylindrical M18or M30 housing.
8
For industrialapplications
8 nf Cable • KG50691)
Sensingrange[mm]
Connection Teachfunction
Order no.
DC PNP
M18 housing, plastic
15 nf M12connector – KI5052
M30 housing, plastic
20 nf M12connector • KI5083
8 f M12connector • KI5085
M30 housing, metal
15 nf M12connector • KI5087
8 nf M12connector
– KG5057
• KG5071
12 nf M12connector • KG5066
1) Housing, white PPf: flush installation nf: non-flush installation
9
Capacitive point level.Detection through non-metallic tank walls.
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
es
Sensingrange[mm]
Connection Order no.
DC PNP
12 nfCable 2 m KQ6002
Cable 10 m KQ6007
12 nf Cable plugM8 KQ6004
12 nf Cable plugM12 KQ6005
Type KQpoint level sensor
Capacitive sensorsin small plasticrectangularhousing.
Easy installationwith mountingadapters andfixing straps.
DC NPN
12 nf
12 nf
Cable 2 m KQ6006
Cable plugM12 KQ6016
DC PNP
12 nf
12 nf
Cable 2 m KQ5100
Cable plugM12 KQ5101
12 nf Cable plugM8 KQ5102
f: flush installation nf: non-flush installation
Professional:For industrial applications.
Manifold:Versions with 2 or 4 switchingoutputs or analogue output4...20 mA / 0...10 V.
Safe:Type LK12 with approval asoverflow protection.
Combined:Type LT for level and temperaturemonitoring.
Type LKlevel sensor
Display and hand-ling directly onthe unit.
As an option withanalogue outputor up to fourswitching outputs.
Suitable for oiltemperatures upto 70 °C.
Versions to theGerman FederalWater Actavailable.
For industrialapplications
264 LK1022
Rod length
[mm]
Version Order no.
2 switching outputs
1 switching output, 1 analogue output 4...20 mA, 0...10 V
472 LK1023
728 LK1024
264 WHG* LK1222
472 WHG* LK1223
728 WHG* LK1224
10
264 LK3122
472 LK3123
728 LK3124
2 switching outputs
264Automatic
medium detection
LK7022
472 LK7023
728 LK7024
4 switching outputs
264 LK8122
472 LK8123
728 LK8124
* German Federal Water Act
Continuous capacitive level measurement.For applications on hydraulic and coolant tanks.
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
es
Type LTlevel sensor
For level andtemperature.
Suitable for oils upto 70 °C.
11
264 For level and temperature LT8022
Rod length
[mm]
Version Order no.
2 x 2 switching outputs level / temperature
472 For level and temperature LT8023
728 For level and temperature LT8024
For adapterssee pages22 - 23
Versatile:Modular sensor concept, flexiblein use.
Variable:Rods can be cut to size asrequired.
Reliable:Measuring principle independentof temperature influences.
Optional outputs:Versions with two or fourswitching outputs or analogueoutput 4...20 mA / 0...10 V.
Selectable:Designs with and withoutdisplay.
Type LRlevel sensor
Display and hand-ling on the unit orvia IO-Link.
As an option withanalogue outputor up to fourswitching outputs.
Rod lengthsfreely selectablebetween10...200 cm.
Versions to theGerman FederalWater Actavailable.
G 3/4 male LR2050
Processconnection
Order no.
2 switching outputs or 1 switching output and1 analogue output 4...20 mA
G 3/4 male LR7000
3/4" NPT LR7300
Processconnection
Order no.
2 switching outputs
G 3/4 male LR9020
Processconnection
Order no.
1 analogue output 4...20 mA or 0...10 V
G 3/4 male LR3000
3/4" NPT LR3300
1 switching output and1 analogue output 4...20 mA or 0...10 V
For industrialapplications
For hygienic areasand viscous media
12
Type LRlevel transmitter
For industrialapplications.
Analogue outputscalable4...20 mA / 0...10 V.
Protection ratingIP 69K.
Easily adjustablevia IO-Link.
G 3/4 male LR8000
3/4" NPT LR8300
4 switching outputs
G 3/4 male LR80101)
4 switching outputs / WHG*
* German Federal Water Act1) Only in connection with rod and coaxial pipe,
see page 14
Continuous level measurement with guided microwave.For industrial and hygienic applications.
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
esAseptoflex Vario G1 LR2750
Processconnection
Order no.
2 switching outputs or 1 switching output and1 analogue output 4...20 mA
Type LR27hygienic levelsensor
Display and hand-ling on the unit orvia IO-Link.
Medium tempera-ture -40...150 °C.
Pressure-resistantup to 40 bar.
Rod lengthsof 15...200 cmselectable.
13
For rods andcoaxial pipessee pages14 - 15
For adapterssee pages22 - 23
G 3/4
G 3/4
14
For industrialapplications
For hygienic areasand viscous media
700 E43205
Length
[mm]
Order no.
Level sensor3/4" NPTType LR3300Type LR7300Type LR8300
800 E43337
1000 E43207
1200 E43208
1400 E43209
1600 E43210
2000 E433532)
2) Only for type LR2050 sensor
150 E43225
Length
[mm]
Order no.
210 E43351
240 E43203
265 E43352
300 E43226
450 E43204
500 E43227
Rods for LR levelsensors with 3/4"NPT oder G 3/4male, industrialapplications
Material:high-gradestainless steel(1.4404 / 316L)
1) Only in connectionwith rod andcoaxial pipe
Level sensorG 3/4 maleType LR2050Type LR3000Type LR7000Type LR8000Type LR80101)
Type LR9020
150 E43230
Processconnection
Length
[mm]
Order no.
210 E43354
240 E43211
265 E43355
300 E43228
450 E43212
500 E43229
700 E43213
800 E43336
1000 E43214
1200 E43215
1400 E43216
1600 E43217
2000 E433562)
700, slotted E43333
1200, slotted E43334
2) Only for type LR2050 sensor
Coaxial pipes forLR level sensorswith G 3/4 male,industrialapplications
Material:high-gradestainless steel(1.4301 / 304)
15
Continuous level measurementwith guided microwave.Rods and coaxial pipes.
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
es
3/4" NPT
450 E43218
Processconnection
Length
[mm]
Order no.
700 E43219
1000 E43220
1200 E43223
1400 E43224
1600 E43221
150 E43345
Length
[mm]
Order no.
300 E43346
500 E43340
700 E43347
1000 E43341
1500 E43348
2000 E43342
Type LR2750hygienic levelsensor
Rods for levelsensor typeLR2750, hygienicapplications
Material:high-gradestainless steel(1.4404 / 316L)
For a wide
selection of other
accessories visit
www.ifm.com
For adapterssee pages22 - 23
16
Robust:Overload-protected measuringprinciples with a good long-termstability.
Versatile:Compact sensors with andwithout display.
Precise:Ceramic-capacitive andpiezoresistive measuring cells.
For industrialapplications
Type PApressure sensor
2-wire pressuretransmitter.
Ceramic-capacitivemeasuring cell.
G 1/4 female 0...1000 0...1000 PA9027
Processconnection
Relative pressuremeasuring range
[mbar]
Relative pressuremeasuring range
[mbar]
Order no.
Analogue output 4...20 mA Analogue output 0...10 V
Type PSsubmersiblepressuretransmitter
PUR or FEP cablefor high resistanceto media.
Version with ATEXapproval forgroup I cat. M1and group IIcat. 1G and 1D.
Pressure compen-sation via inter-nally vented cable.
Order no.
PA3027
G 1/4 female 0...250 0...250 PA9028PA3028
G 1/4 male 0...250 PA3528
G 1/4 male 0...100 PA3589
0.25 FEP, 5 PS4208
Relative pressuremeasuring range
[mbar]
Cable
[m]
Order no.
For high resistance to media, CE approval
0.6 FEP, 10 PS4407
1 FEP, 15 PS4417
0.25 FEP, 5 PS308A
For hazardous areas, CE, Ex, GL approvals
0.6 FEP, 10 PS307A
1 FEP, 15 PS317A
0.25 PUR, 5 PS3208
Relative pressuremeasuring range
[mbar]
Cable
[m]
Order no.
For standard applications, CE approval
0.6 PUR, 10 PS3407
0.6 PUR, 15 PS3427
0.6 PUR, 30 PS3607
1 PUR, 15 PS3417
1 PUR, 30 PS3617
17
Continuous hydrostatic level measurementin industrial applications.For use on tanks and in free-flowing waterways.
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
es
Processconnection
Relative pressuremeasuring range
[mbar]
Relative pressuremeasuring range
[mbar]
Order no.
2 switching outputs 1 switching output and1 analogue outp. 4...20 mA / 0...10 V
Order no.
G 1/4 female 0...1000 0...1000 PN3097PN7097
G 1/4 male 0...1000 0...1000 PN3597PN7597
2 switching outputs or 1 switching output and1 analogue output 4...20 mA / 0...10 V, scalable
G 1/4 female 0...1000 -12.5...250 PN2098PN2097
G 1/4 male 0...1000 -12.5...250 PN2598PN2597
G 1/4 female -500...500 PN2169
G 1/4 male -500...500 PN2569
Type PN pressuresensor
Programmable2-colour display,clearly visibleswitch-point LEDs.
Rotatable processconnection.
Operation via3 raised push-buttons.
Type PGpressure sensor
Optimumlegibility due tothe electronicpointer display.
Rotatable display.
Display of thetrend or of theminimum andmaximum values.
Processconnection
Relative pressuremeasuring range
[mbar]
1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable
Order no.
G 1/2 male 0...1000 PG2457
G 1/2 male 0...250 PG2458
G 1/2 male 0...100 PG2489
For adapterssee pages22 - 23
18
G1 maleAseptoflex Vario
-0.01...0.1 PG2789
Hygienic:Ingress resistance, materialand approvals according tohygiene requirements.
Robust:Overload-resistant ceramic-capacitive measuring cells withlong-term stability.
Versatile:Variable process connections.
Precise:High overall accuracy (0,2 %).
For CIP / SIP applications:High temperature resistanceand electronic temperaturecompensation.
For hygienic areasand viscous media
Type PGpressure sensor
Optimumlegibility due tothe electronicpointer display.
Rotatable display.
Display of thetrend or of theminimum andmaximum values.
Processconnection
Measuringrange[bar]
Order no.
1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable
-0.01...0.25 PG2798
-0.05...1 PG2797
-1...1 PG2799
G1 malesealing cone
-0.01...0.1 PG2889
-0.01...0.25 PG2898
-0.05...1 PG2897
-1...1 PG2899
19
Continuous hydrostatic level measurementin hygienic areas.For applications on large tanks.
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
esG1 male
Aseptoflex Vario
-0.01...0.1 PI2789
Type PIpressure sensor
Programmableanalogue outputin 2-wireoperation.
Additionalswitching outputin 3/4-wireoperation.
Processconnection
Measuringrange[bar]
Order no.
1 switching output and1 analogue output 4...20 mA / 20...4 mA
-0.01...0.25 PI2798
-0.05...1 PI2797
-1...1 PI2799
G1 malesealing cone
-0.01...0.1 PI2889
-0.01...0.25 PI2898
-0.05...1 PI2897
-1...1 PI2899
For adapterssee pages22 - 23
20
Longest distances:Photoelectric level detectionof bulk materials and non-transparent liquids, for levelsup to 9.8 m.
Convenient:Scalable detection range withwindow function.
Reliable detection:Can be used in applicationsneeding background suppression.
Flexible mounting:Extensive range of fixingcomponents.
For industrialapplications
0.2...9.8 M12connector < 15 x 15
Measuringrange
[m]
Connection Light spot diameter
[mm]
2 switching outputs or 1 switching output and1 analogue output 4...20 mA / 0...10 V, scalable
Type O1D photo-electric distancesensor with timeof flight tech-nology
Resistant to extra-neous light up to100,000 lux.
2 switching out-puts; one outputcan be configuredas analogueoutput.
4-digit alpha-numeric display.
Order no.
O1D300
Order now.
0800 16 16 16 4 or
in the e-shop at
www.ifm.com
21
Continuous photoelectric level measurement.For long distances without contact to the medium.
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
es
Accessories
No. Version Order no.
1 Mounting brackethigh-grade stainless steel (1.4404 / 316L) E21120
2 Clamp mounting set for rod mountØ 12 mm E2D101
3 Mounting adapter withprocess connection G1 male E21224
4 Mounting rod, 100 mm, Ø 12 mm,M10 thread, stainless steel E20938
5 Mounting rod, 200 mm, Ø 12 mm,M10 thread, stainless steel E20940
6 Cube for mounting on an aluminium profile,M10 thread, stainless steel E20951
Mounting accessories
7Protective cover, glass E21171
Device protection
8 Cooling box E21248
Protective cover, PMMA E21133
1
8
7
654
3
2
–
–
–
–
–
E43315
–
–
–
E43309
E43310
–
–
E43311
E43312
–
–
–
–
–
–
–
1
2
Clamp 1 - 1.5"
Processconnection
No. Order no. Order no. withleakage port
E33401
Mounting adapters for industrial and hygienic applications
22
For industrialapplications
For hygienic areasand viscous media
Clamp 2" E33402
Pipe fitting DN25 E43304
Pipe fitting DN40 E43305
3Varivent type F DN25, D = 50 E43306
Varivent type N DN40...150, D = 68 E43307
4 Screw-in adapter G 1 E43303
Screw-in adapter G 3/4 E43302
5 Pipe fitting DN25 SMS E33430
Sealing plug G 1/2 E43308
Screw-in adapter 3/4" NPT E43313
6 Collar G 1/2 Ø 45 mm E30056
Welding adapters for industrial and hygienic applications
7 Ball G 1/2 Ø 35 mm E30055
9 Long design G 1/2 Ø 50 mm E43319
10 Welding mandrel G 1/2 E43314
8For tanks G 1/2 Ø 30 mm E43300
For pipes G 1/2 Ø 29 mm E43301
11
T-piece DN25 E43316
T-pieces for industrial and hygienic applications
T-piece DN40 E43317
T-piece DN50 E43318
12Clamp adapter for type LMT1041) E43349
Variable clamp adapters
Clamp adapter for type LMT1051) E43322
1) Only in connection with G 1/2 female adapter
Adapters G 1/2for type LMT 1
2
3
45
6
7
8
9
10
11
12Adapters fortypes LR, LK
22
23
For a wideselection of otheraccessories visitwww.ifm.com
16 –Flange DRD, D = 65 E33242
E33228
E3322915
Varivent type F DN25, D = 50 E33221
Varivent type N DN40...150, D = 68 E33222
E33208
E33209
–
–
–
–
E33304
23
Accessories.Adapters for level sensors inindustrial and hygienic applications.
Imp
edan
cesp
ectr
osc
op
y
Cap
acit
ive
inco
nta
ct w
ith
the
med
ium
Cap
acit
ive
wit
ho
ut
con
tact
Cap
acit
ive
con
tin
uo
us
Gu
ided
wav
e ra
dar
Hyd
rost
atic
Pho
toel
ectr
icA
cces
sori
es
13
14
Clamp 1 - 1.5"
Processconnection
No. Order no. Order no. withleakage port
E33201
Mounting adapters for industrial and hygienic applications
Clamp 2" E33202
Pipe fitting DN32 E33211
Pipe fitting DN50 E33213
Pipe fitting DN40 E33212
Universal process adapter Rd52 E33340
Pipe fitting DIN 11864-1 A-BS –
Adapters G1 male /Aseptoflex Variofor typesPG, PI, LR
E30130
–
17 Welding adapter Ø 50 mm E30122
Welding adapters for industrial and hygienic applications
Sealing plug E30128
No. Version Order no.
18 Mounting clamp Ø 16 mm E43000
19 Welding adapter Ø 50 mm E43002
Mounting adapters
21Climatic tube, 264 mm long E43100
Device protection
Climatic tube, 728 mm long E43102
Climatic tube, 472 mm long E43101
Mounting adapter G 3/4 E43003
20 Mounting adapter G 1 E43004
Mounting adapter 3/4" NPT E43012
Climatic tube, 132 mm long E43103
No. Version Order no.
22Flange plate 73 - 90 / G 3/4 E43201
Flange plate 65 - 80 / G 3/4 E43202
Mounting adapters
23 Protective cover E43910
Device protection
Find the
suitable socket:
www.ifm.com
13
14
15
16
17
18
19
20
21
Adapters fortypes LI, LK, LT
Visit our website:
www.ifm.com
ifm electronic gmbhFriedrichstraße 145128 EssenTel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200E-mail [email protected]
Over 70 locations worldwide –at a glance at www.ifm.com
Position sensors
Sensors formotion control
Industrial imaging
Safety technology
Process sensors
Condition monitoringsystems
Industrialcommunication
Identification systems
Systems formobile machines
Connectiontechnology
Overviewifm product range:
Accessories
ifm a
rtic
le n
o. 7
8001
767
· We
rese
rve
the
right
to
mak
e te
chni
cal a
ltera
tions
with
out
prio
r no
tice.
· Pr
inte
d in
Ger
man
y on
non
-chl
orin
e bl
each
ed p
aper
. 11/
15