Plunger Lift Reference Guide Base Mgmt Tes t Viper Ring Pad Brush Conventio nal Soli d Multi- Stage Sand Iron Soap Operation The liquid aeration plunger removes the liquid load more efficiently and at higher velocities by jetting gas through orifices in the top of the plunger. The gas jetted through the plunger, as it travels upward, aerates the liquid above the plunger. Name: Liquid Aeration Plunger Manufacturer: PCS Example Wells: · Paschall 4-21 · State c3-28 · Hampton 2-18 · Coblentz b3-1 Name: Two-Pad Manufacturer: PCS Name: Single Pad Manufacturer: IPS Example Wells: · Austin 5- 13 · Heitner 4- 13 · Picaro 2- 36 Example Wells: · James 4-24 · Mcalester 6- 22 · State c1-28 · Hampton 3-18 · Kinnkin Pate 1-3 Name: Triple Pad Manufacturer: PCS Example Wells: · Nan 1-15 · Simon 3- 27 Operation The Pad plunger works as a typical conventional plunger and is available in 1, 2, and 3 pad models. The spring loaded pads press against the tubing wall in order to create a highly efficient seal bringing more fluid to the surface and avoiding liquid flowback. Name: Standard Solid Plunger Manufacturer: PCS Operation The solid plungers are heavy and able to cut through paraffin with faster fall velocities. The plunger has no moving parts and is durable. Name: Viper Manufacturer : Well Master Example Wells: · Smith 7-20 · State c2-28 · Dunagan 1-13 · Hampton 2-18 · Yourman 7-15 · Foster 1 Operation The Viper plunger is a useful deliquification plunger in wells producing formation or frac sand. This conventional plunger is a solid plunger with a hollow core. The hollow core is connected to radial holes on the exterior that direct turbulent gas to the tubing wall pressure washing the wall on the upstroke. The radial grooves in the bottom create spinning action on the upstroke and down stroke. Name: Spiral Sand Plunger Manufacturer: PCS Example Wells: · Varnum, Guy 4-25 Gas Exi t Jet s Operation The sand plunger operates similar to the Wellmaster Viper. The sand plunger from PCS offers grooves at the bottom of the plunger that creates a spinning turbulent seal. Also, the sand plunger allows gas to flow into the plunger and clean out grooves to prevent sand from sticking the plunger. Name: Wobble Washer Manufacturer: PCS Operation The Ring plunger is similar to the triple pad plungers. Shifting rings keep continuous contact against the tubing walls producing a highly effective seal as well as wiping the tubing before the paraffin can harden. The seal is affected due to the movement of gas by the specially shaped washer held against the tubing wall with eccentric springs. Example Wells: · Sunflower 3 · Anderson 3 · Orr 7 Name: Brush Manufacturer: PCS Operation The brush plunger is a solid mandrel wound with flexible brush fibers. Most of the time these plungers are constructed with undercuts ensuring descalling of the tubing. Operation The plungers come with a stationary plunger, retrieval plunger, traveling plunger, and drop off plunger. The traveling device is able to collect data in a shut-in or flowing well and is cycled just as any other plunger and caught in the lubricator. The Drop Off plunger attaches to the fishneck of the stationary plunger and is dropped in the well. When the two plungers reach the bottom the thermocouple activates at a predetermined temperature and the plungers separate. The Drop off plunger is cycled to the surface. When the stationary plunger is ready to come out, the retrieval plunger is dropped in the well, and an overshot grabs the stationary plunger and the two are cycle to the surface. Example Wells: · Myton 18 · Foster 1-7 · Martin C 7 Name: Smart Plunger Manufacturer: PCS Name: Shuttle Plunger Manufacturer: Go Tek Example Wells: · Topping State 1-9 Name: Multi Stage Tool Manufacturer: PCS Operation The multi stage plunger creates bottom hole pressure by staging the well. The multi stage tool is usually landed between 40-70% of the way down the well. The bottom stage is a traditional plunger setup with a downhole spring, stop, and conventional plunger. When the well is open the bottom stage moves fluid up the hole and the gas bubble above it provides energy to the second stage. The top plunger lifts the column of fluid to the surface as the bottom plunger arrives at the multi stage assembly with a load for the next trip. When the well shuts, the top and bottom plungers fall simultaneously. 1 Ball and Seat (Flow Cage) – maintains the one way flow of liquids up the tubing and keeps liquids from the bottom stage until the top plunger can retrieve it. 2 Seal Element (Pack Off) – Seals as fluids are delivered keeping fluid above the flow cage. 3 Resettable locking mechanism – Holds the tool in open position for an easy installation and then sets to the closed position when depth is reached. 4 Collar stop 5 Bumper Spring – absorbs the impact of the arriving plunger. Cody Hopkins | Summer Intern 2010 | Arkoma Asset | Base Mgmt Well Velocity Below 10ft/s 1 3 4 5 2 Stationa ry Travel ing Drop Off Retrieval High Speed Non- Conventional Pacemak er By Pass Name: Pacemaker Manufacturer: IPS Operation The two pieces of the plunger begin the cycle on the down hole assembly with plunger and ball traveling together as one unit as shown in Fig. 1. The differential pressure below the unit holds the two pieces together as the well begins to flow. Then as one unit, the plunger lifts accumulated fluid to the surface. In the lubricator at the surface, a shifting rod awaits the arrival of the plunger (Fig 2). The shifting rod separates the ball and sleeve, as in figure 3. The ball begins to fall back to the bottom-hole assembly, while the sleeve is held in place by the shifting rod. The auto-adjust controller determines when the motor valves close the well control valves to shut in the well and allow the plunger to fall through the wellhead. The well remains shut in for a short period for the plunger to pass through the wellhead and then resumes production while the plunger body falls back to the bottom. Example Wells: · Dungeon 2- 13 · Fazekas 6- 17 · Yourman 6- 15 Name: Center By Pass Manufacturer: PCS Name: Ring Frictionless By Pass Manufacturer: PCS Name: Rapid Drop Manufacturer: IPS Example Wells: · Fazekas 2- 17 · Circle F 2-25 Flow Through Ports Shift ing Rod Operation The By-Pass plungers with pads allow for the seal of a pad plunger for better fluid recovery, while offering flow through the plunger. The trip rods that open the plunger and allow flow can be located in the lubricator or on the plunger. Well Velocity Below 15 Ft/s Plung er Shifting Rod Standing Valve and Spring Assembly Ba ll Adjustments to control the by pass area Operation Drop Phase: The traveling dart is in the open position below the flow ports allowing high rates of gas and liquid to flow through the plunger. Bottom Phase: The plunger falls to bottom and the traveling dart shifts to the closed position preventing flow through the plunger. Lifting Phase: After the dart moves to the closed position and flow no longer goes through it, the plunger will travel to the surface, lifting all liquids above it. Top Phase: Once the fluid and plunger have arrived at the surface, a rod in the lubricator will shift the dart off seat and allow the plunger to fall for another cycle. Shiftin g Rod/Dar t Port s Hollow center Port s By Pass with Pad Name: Stingray Manufacturer: Well Master Name: Padded Sleeve By-Pass Manufacturer: PCS Ports Ports Pads Shiftin g Rod Adjustment to Control By Pass Area Pads Ports Shiftin g Rod Pads By Pass Non- Conventional Ga s Ex it Je ts Small Orifices Where Gas Exits Gas Enters Snak e Name: Snake Manufacturer: PCS Example Wells: · Quinton 3- 20 Operation The snake plunger operates as a normal conventional plunger. It offers a flexible core that allows for bending and movement through tubing irregularities. Operation The Shuttle Plunger contains a temperature gauge, pressure gauge, and collar locator. Unlike the Smart plunger which is available in many different styles, the shuttle plunger is a traveling plunger and only available in a solid plunger style. The Shuttle plunger can be downloaded via usb to a laptop in the field for evaluation. Example Wells: · Orr 2 Lubricator: Pacemaker Fall Time: 700- 900 ft/m Example Wells: · None Lubricator: Quick Drop Fall Time: 600- 800 ft/m Lubricator: Quick Drop Fall Time: 600- 800 ft/m Lubricator: Pacemaker Fall Time: 600-800 ft/m Example Wells: · None Example Wells: · None Example Wells: · None Lubricator: Quick Drop Fall Time: 500- 750 ft/m Lubricator: Quick Drop Fall Time: 500- 750 ft/m Lubricator: Conventional Fall Time: 450- 500 ft/m Lubricator: Conventional Fall Time: 150- 250 ft/m Lubricator: Conventional Fall Time: 450- 500 ft/m Lubricator: Conventional Fall Time: 400- 500 ft/m Lubricator: Conventional Fall Time: 400- 500 ft/m Lubricator: Conventional Fall Time: 200- 350 ft/m Lubricator: Conventional Fall Time: 300- 400 ft/m Lubricator: Conventional Fall Time: 300- 350 ft/m Example Wells: · None Example Wells: · None Lubricator: Conventional Fall Time: 450- 500 ft/m Lubricator: Conventional Fall Time: 400- 500 ft/m Lubricator: Conventional Fall Time: 350- 450 ft/m Lubricator: Conventional Fall Time: 350- 450 ft/m Testi ng Paraffin Deviat ed Wells Sand/ Solids Liquid Unloading Low Pressure and/or Marginal Well Operation Drop Phase: The plunger falls and allows fluid and gas to flow between the outer body and internal rod. Some of the exit ports can be closed to restrict the flow through the plunger to help achieve the most efficient cycle time. Bottom Phase: The plunger falls to bottom and the rod shifts to the closed position preventing gas or liquid from flowing through the plunger. Lifting Phase: After the plunger closes and flow no longer moves through it, the plunger will travel to the surface, lifting all fluid above it. Top Phase: Once the fluid and plunger have arrived at the surface, the internal rod will shift to the open position to allow the plunger to fall for another cycle. Operation Drop Phase: The plunger has a sliding sleeve that while in the open position allows gas and liquid to flow through an inner mandrel and exit the flow port at the top of the mandrel. Bottom Phase: The plunger falls to bottom and the sliding sleeve falls to the closed position preventing gas and liquid from flowing through the plunger. Lifting Phase: After the sleeve closes and flow no longer travels through the plunger, the plunger will travel to the surface, lifting all liquids above it. Top Phase: Once the fluid and plunger have arrived at the surface, the sleeve will be shifted to the open position to allow the plunger to fall for another cycle.

Transcript of Plunger Lift Reference Guide Base Mgmt Test Viper Ring Pad Brush Conventional Solid Multi-Stage Sand...

Page 1: Plunger Lift Reference Guide Base Mgmt Test Viper Ring Pad Brush Conventional Solid Multi-Stage Sand Iron Soap Operation The liquid aeration plunger removes.

Plunger Lift Reference GuideBase Mgmt

Test Viper

Ring Pad

Brush

Conventional

Solid

Multi-Stage SandIron

Soap

OperationThe liquid aeration plunger removes the liquid load more efficiently and at higher velocities by jetting gas through orifices in the top of the plunger. The gas jetted through the plunger, as it travels upward, aerates the liquid above the plunger.

Name: Liquid Aeration PlungerManufacturer: PCSExample Wells:· Paschall 4-21· State c3-28· Hampton 2-18· Coblentz b3-1

Name: Two-PadManufacturer: PCS

Name: Single PadManufacturer: IPSExample Wells:· Austin 5-13· Heitner 4-

13· Picaro 2-36

Example Wells:· James 4-24· Mcalester 6-22· State c1-28· Hampton 3-18· Kinnkin Pate 1-

3

Name: Triple PadManufacturer: PCSExample Wells:· Nan 1-15· Simon 3-

27

OperationThe Pad plunger works as a typical conventional plunger and is available in 1, 2, and 3 pad models. The spring loaded pads press against the tubing wall in order to create a highly efficient seal bringing more fluid to the surface and avoiding liquid flowback.

Name: Standard Solid PlungerManufacturer: PCS

OperationThe solid plungers are heavy and able to cut through paraffin with faster fall velocities. The plunger has no moving parts and is durable.

Name: ViperManufacturer: Well Master

Example Wells:· Smith 7-20· State c2-28· Dunagan 1-13· Hampton 2-18· Yourman 7-15· Foster 1

OperationThe Viper plunger is a useful deliquification plunger in wells producing formation or frac sand. This conventional plunger is a solid plunger with a hollow core. The hollow core is connected to radial holes on the exterior that direct turbulent gas to the tubing wall pressure washing the wall on the upstroke. The radial grooves in the bottom create spinning action on the upstroke and down stroke.

Name: Spiral Sand PlungerManufacturer: PCSExample Wells:· Varnum,

Guy 4-25Gas Exit Jets

OperationThe sand plunger operates similar to the Wellmaster Viper. The sand plunger from PCS offers grooves at the bottom of the plunger that creates a spinning turbulent seal. Also, the sand plunger allows gas to flow into the plunger and clean out grooves to prevent sand from sticking the plunger.

Name: Wobble WasherManufacturer: PCS

OperationThe Ring plunger is similar to the triple pad plungers. Shifting rings keep continuous contact against the tubing walls producing a highly effective seal as well as wiping the tubing before the paraffin can harden. The seal is affected due to the movement of gas by the specially shaped washer held against the tubing wall with eccentric springs.

Example Wells:· Sunflower

3· Anderson 3· Orr 7

Name: BrushManufacturer: PCS

OperationThe brush plunger is a solid mandrel wound with flexible brush fibers. Most of the time these plungers are constructed with undercuts ensuring descalling of the tubing.

OperationThe plungers come with a stationary plunger, retrieval plunger, traveling plunger, and drop off plunger. The traveling device is able to collect data in a shut-in or flowing well and is cycled just as any other plunger and caught in the lubricator. The Drop Off plunger attaches to the fishneck of the stationary plunger and is dropped in the well. When the two plungers reach the bottom the thermocouple activates at a predetermined temperature and the plungers separate. The Drop off plunger is cycled to the surface. When the stationary plunger is ready to come out, the retrieval plunger is dropped in the well, and an overshot grabs the stationary plunger and the two are cycle to the surface.

Example Wells:· Myton 18· Foster 1-

7· Martin C

7

Name: Smart PlungerManufacturer: PCS

Name: Shuttle PlungerManufacturer: Go Tek

Example Wells:· Topping State 1-

9

Name: Multi Stage ToolManufacturer: PCS

OperationThe multi stage plunger creates bottom hole pressure by staging the well. The multi stage tool is usually landed between 40-70% of the way down the well. The bottom stage is a traditional plunger setup with a downhole spring, stop, and conventional plunger. When the well is open the bottom stage moves fluid up the hole and the gas bubble above it provides energy to the second stage. The top plunger lifts the column of fluid to the surface as the bottom plunger arrives at the multi stage assembly with a load for the next trip. When the well shuts, the top and bottom plungers fall simultaneously. 1 Ball and Seat (Flow Cage) – maintains the one way

flow of liquids up the tubing and keeps liquids from the bottom stage until the top plunger can retrieve it.2 Seal Element (Pack Off) – Seals as fluids are delivered keeping fluid above the flow cage.3 Resettable locking mechanism – Holds the tool in open position for an easy installation and then sets to the closed position when depth is reached.4 Collar stop5 Bumper Spring – absorbs the impact of the arriving plunger.

Cody Hopkins | Summer Intern 2010 | Arkoma Asset | Base Mgmt

Well Velocity Below 10ft/s

1

3

4

5

2

Stationary

Traveling

Drop Off

Retrieval

High Speed Non-Conventional

Pacemaker

By Pass

Name: PacemakerManufacturer: IPS

OperationThe two pieces of the plunger begin the cycle on the down hole assembly with plunger and ball traveling together as one unit as shown in Fig. 1. The differential pressure below the unit holds the two pieces together as the well begins to flow. Then as one unit, the plunger lifts accumulated fluid to the surface. In the lubricator at the surface, a shifting rod awaits the arrival of the plunger (Fig 2). The shifting rod separates the ball and sleeve, as in figure 3. The ball begins to fall back to the bottom-hole assembly, while the sleeve is held in place by the shifting rod. The auto-adjust controller determines when the motor valves close the well control valves to shut in the well and allow the plunger to fall through the wellhead. The well remains shut in for a short period for the plunger to pass through the wellhead and then resumes production while the plunger body falls back to the bottom.

Example Wells:· Dungeon 2-13· Fazekas 6-17· Yourman 6-15

Name: Center By PassManufacturer: PCS

Name: Ring Frictionless By PassManufacturer: PCS

Name: Rapid DropManufacturer: IPS

Example Wells:· Fazekas 2-17· Circle F 2-25

Flow Through Ports

Shifting Rod

OperationThe By-Pass plungers with pads allow for the seal of a pad plunger for better fluid recovery, while offering flow through the plunger. The trip rods that open the plunger and allow flow can be located in the lubricator or on the plunger.

Well Velocity Below 15 Ft/s

Plunger

Shifting Rod

Standing Valve and Spring Assembly

Ball

Adjustments to control the by pass area

OperationDrop Phase: The traveling dart is in the

open position below the flow ports allowing high rates of gas and liquid to flow through the plunger.

Bottom Phase: The plunger falls to bottom and the traveling dart shifts to the closed position preventing flow through the plunger.

Lifting Phase: After the dart moves to the closed position and flow no longer goes through it, the plunger will travel to the surface, lifting all liquids above it.

Top Phase: Once the fluid and plunger have arrived at the surface, a rod in the lubricator will shift the dart off seat and allow the plunger to fall for another cycle.

Shifting Rod/Dart

Ports

Hollow centerPorts By Pass with PadName: Stingray Manufacturer: Well Master

Name: Padded Sleeve By-PassManufacturer: PCS

Ports

Ports

Pads

Shifting Rod

Adjustment to Control By Pass Area

Pads

Ports

Shifting Rod

Pads

By Pass Non-Conventional

Gas Exit Jets

Small Orifices Where Gas

Exits

Gas Enters

SnakeName: Snake

Manufacturer: PCSExample Wells:· Quinton 3-20

OperationThe snake plunger operates as a normal conventional plunger. It offers a flexible core that allows for bending and movement through tubing irregularities.

OperationThe Shuttle Plunger contains a temperature gauge, pressure gauge, and collar locator. Unlike the Smart plunger which is available in many different styles, the shuttle plunger is a traveling plunger and only available in a solid plunger style. The Shuttle plunger can be downloaded via usb to a laptop in the field for evaluation.

Example Wells:· Orr 2

Lubricator: PacemakerFall Time: 700-900 ft/m

Example Wells:· None

Lubricator: Quick DropFall Time: 600-800 ft/m

Lubricator: Quick DropFall Time: 600-800 ft/m

Lubricator: PacemakerFall Time: 600-800 ft/m

Example Wells:· None

Example Wells:· None

Example Wells:· None

Lubricator: Quick DropFall Time: 500-750 ft/m

Lubricator: Quick DropFall Time: 500-750 ft/m

Lubricator: ConventionalFall Time: 450-500 ft/m

Lubricator: ConventionalFall Time: 150-250 ft/m

Lubricator: ConventionalFall Time: 450-500 ft/m

Lubricator: ConventionalFall Time: 400-500 ft/m

Lubricator: ConventionalFall Time: 400-500 ft/m

Lubricator: ConventionalFall Time: 200-350 ft/m Lubricator:

ConventionalFall Time: 300-400 ft/m

Lubricator: ConventionalFall Time: 300-350 ft/m

Example Wells:· None

Example Wells:· None

Lubricator: ConventionalFall Time: 450-500 ft/m

Lubricator: ConventionalFall Time: 400-500 ft/m

Lubricator: ConventionalFall Time: 350-450 ft/m

Lubricator: ConventionalFall Time: 350-450 ft/m

Testing

ParaffinDeviated Wells

Sand/Solids

Liquid Unloading

Low Pressure and/or Marginal Well

OperationDrop Phase: The plunger falls and allows

fluid and gas to flow between the outer body and internal rod. Some of the exit ports can be closed to restrict the flow through the plunger to help achieve the most efficient cycle time.

Bottom Phase: The plunger falls to bottom and the rod shifts to the closed position preventing gas or liquid from flowing through the plunger.

Lifting Phase: After the plunger closes and flow no longer moves through it, the plunger will travel to the surface, lifting all fluid above it.

Top Phase: Once the fluid and plunger have arrived at the surface, the internal rod will shift to the open position to allow the plunger to fall for another cycle.

OperationDrop Phase: The plunger has

a sliding sleeve that while in the open position allows gas and liquid to flow through an inner mandrel and exit the flow port at the top of the mandrel.

Bottom Phase: The plunger falls to bottom and the sliding sleeve falls to the closed position preventing gas and liquid from flowing through the plunger.

Lifting Phase: After the sleeve closes and flow no longer travels through the plunger, the plunger will travel to the surface, lifting all liquids above it.

Top Phase: Once the fluid and plunger have arrived at the surface, the sleeve will be shifted to the open position to allow the plunger to fall for another cycle.

Page 2: Plunger Lift Reference Guide Base Mgmt Test Viper Ring Pad Brush Conventional Solid Multi-Stage Sand Iron Soap Operation The liquid aeration plunger removes.

Plunger Lift Reference GuideBase Mgmt

Life Cycle of the WellStage 1:

Well is flowing above critical rate with all flow in mist flow, no liquid gradient at anytime.• No deliquification Required

Stage 2:

Well begins to bubble and slug when rates fall below critical. •If velocity > 15ft/s the well is a candidate for a high speed non-conventional plunger such (i.e. pacemaker).

•The wells normally still have high Gas to Liquid Ratios, meaning that they do not require and shut in time. The high GLR also allows for flow of gas to sales after the arrival of the plunger at the lubricator (after-flow).

•The after-flow allows the two pieces of the plunger to distance themselves, creating a large by-pass area and reducing shut-in time. The reduced shut-in time, means more trips per-day and more water brought to surface.

Stage 3:

Well begins to have difficulty maintaining seal due to velocity getting below 15ft/s but greater than 10ft/s.•Candidate for by-pass style, non-convention al plunger

•These wells may still require a lot of trips to remain unloaded, but need little or no flow time after each trip. Pacemaker wells running with significant off time or wells that have just begun “slug – flow” conditions are indicators of this life cycle stage.

•These non-conventional plungers can reach the bottom almost as quick as the pacemaker, but do not require any after- flow since it is one piece.

Stage 4:

Well has velocity < 10ft/s •Candidate for conventional style plunger (i.e. iron soap, pad, viper, etc).

•This stage of the life cycle occurs when GLR decrease and pressure build up is required to trip the plunger.

•The conventional plunger comes in many different styles in order to adapt to well conditions such as: sand, fluid load, tubing irregularities, or scale.

Stage 5:

Well has such low bottom-hole pressure that a conventional plunger doesn’t work.•Candidate for multi stage plunger

•This is the final stage in a wells life, when the GLR drops so low that a conventional plunger won’t cycle.

•The Multi-Stage plunger stages the well into parts and creates bottom hole pressure by reducing the distance any single plunger has to travel.

2-7/ 8" Tubing (ID 2.441")

0

500

1000

1500

2000

0 100 200 300 400 500 600 700 800 900 1000

Wellhead Pressure (psi)

Flow

Rat

e (M

cf/d

ay)

Critical Flow 15 ft/ s 10 ft/ s Poly. (Critical Flow)

2-3/ 8", 4.7 ppf Tubing (ID 1.995")

0200400600800

100012001400160018002000

0 200 400 600 800 1000

Wellhead Pressure (psi)

Flow

Rat

e (M

cf/d

ay)

Critical Flow 15 ft/ s 10 ft/ s Poly. (Critical Flow)

3-1/ 2" Tubing (ID 2.992")

0

500

1000

1500

2000

2500

0 100 200 300 400 500 600 700

Wellhead Pressure (psi)

Flow

Rat

e (M

cf/d

ay)

Critical Flow 15 ft/ s 10 ft/ s Poly. (Critical Flow)

Common Plunger Lift Setup

In this range for actual production, the recommendation would be to install a high speed non-conventional plunger (i.e. pacemaker).

In this range, the recommendation would be to run a bypass style non-conventional plunger

At lower flow rates (below 10ft/s), a conventional style of plunger would be recommended

Surface Equipment

Fazekas #5

Lubricator

Controller / Motor Valve

Flow Line to Sales

Master Valve

Cody Hopkins | Summer Intern 2010 | Arkoma Asset | Base Mgmt

Lubricators

Cap

Catcher

Outlet

Spring

IPS Pace Maker Lubricator

PCS Conventional

Lubricator

Bumper Spring AssemblyThe lubricator is installed on top of the tree or master valve to cushions the plunger upon arrival into the wellhead to prevent damage. The spring inside absorbs the impact of the plunger. The catcher holds the plunger in place and allows for safe removal of the plunger or inspection. All lubricators are available with on or two outlets.

PCS Bumper Spring Features:

• Standard Fishing Neck• Tapered body• Spring

-Helps prevent down hole damage due to plunger fall

4.Mandrel5.Standing Valve Cage

- ball and seat are used to hold liquid in the tubing

6.“No-Go”-prevent fall through seating nipple

7.Cups-sits in the seating nipple

8. Locking Mechanism8.Orifice

- allows flow through the bumper spring assembly

Standing valves

In this set-up the shifting rod is inserted into the spring. During the operation the spring and rod will be assembled as shown inside the lubricator.

Cap

Catcher (once plunger is at the surface, it can be caught by shifting the handle)

Outlet

Threaded to Remove Plunger

Bumper plate

Spring

Shifting Rod

Catcher

Outlet

Threaded to Remove Plunger

Bumper plate

Spring

Pace Maker text is right side up, indicating it is for use with the pace maker

Pace Maker text is upside down

Ledges to hold the spring or shifting rod in the lubricator.

Pace Maker Setup Conventional Setup Top View

To change from the Pace Maker setup to this conventional setup, the upper portion must be unscrewed and flipped around. The shifting rod also must be pulled out and a second bumper spring ( not pictured) must be placed inside the existing spring.