NYC Department of Education Building Condition Assessment Survey 2019-2020 R881 Architectural Inspection Inspection Type Last Edited Time In InspectionId PETRIDES COMPLEX - (BLDG H) - S.I., 715 OCEAN TERRACE, STATEN ISLAND, NY, 10301 School: 4930 2020-07-14 08:20AM 2020-07-20 04:06PM ARCHITECTURAL - ASSOCIATE 4955 2020-07-14 10:32AM 2020-07-23 06:37PM ARCHITECTURAL - SENIOR Asset Data Question Answer Was the Building Fully Accessible for Inspection? Yes Principal(s) Information Principal Name Joanne Buckheit Principal Organization NA Meeting with Principal? No Principal Feedback No Feedback from Principal Custodian David Pedersen Fireman Anthony Nagliocco and Thomas Bickerton Building Square Footage 10,000 Comments on the Area (Square Feet) None Comments on the Stories (Floors) plus Basements 1 (No Basement) Comments on the Year Built 1967 Comments on the Student Population 0 Comments on the Staff Population NA Comments on the Number of Classrooms 0 Weather Fair Facade Photo Safety City Boulevard - Northwest View Main Entrance Photo Facade A Roof Photo Not taken Have any Systems/Major Building Components been upgraded? Systems: New Roof and interior upgrades for DOE use. Page 1 of 12 Print Date: 9/11/2020 Mobile Validity Version 2.0 (P)

Transcript of PETRIDES COMPLEX - (BLDG H) - S.I., 715 OCEAN ...NYC Department of Education Building Condition...

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Inspection Type Last EditedTime InInspectionId

    PETRIDES COMPLEX - (BLDG H) - S.I., 715 OCEAN TERRACE, STATEN ISLAND, NY, 10301School:

    4930 2020-07-14 08:20AM 2020-07-20 04:06PMARCHITECTURAL - ASSOCIATE

    4955 2020-07-14 10:32AM 2020-07-23 06:37PMARCHITECTURAL - SENIOR

    Asset DataQuestion Answer

    Was the Building Fully Accessible for Inspection? Yes

    Principal(s) Information

    Principal Name Joanne Buckheit

    Principal Organization NA

    Meeting with Principal? No

    Principal Feedback No Feedback from Principal

    Custodian David Pedersen

    Fireman Anthony Nagliocco and Thomas Bickerton

    Building Square Footage 10,000

    Comments on the Area (Square Feet) None

    Comments on the Stories (Floors) plus Basements 1 (No Basement)

    Comments on the Year Built 1967

    Comments on the Student Population 0

    Comments on the Staff Population NA

    Comments on the Number of Classrooms 0

    Weather Fair

    Facade Photo

    Safety City Boulevard - Northwest View

    Main Entrance Photo

    Facade A

    Roof Photo Not taken

    Have any Systems/Major Building Components been upgraded? Systems: New Roof and interior upgrades for DOE use.

    Page 1 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural InspectionYears: 2016

    Have there been any New Building Additions? No New Construction

    Tandem No Tandem

    Leased Space? No

    Priority ConditionExist

    Last Year?

    Priority

    Category

    Condition

    Description

    Component

    Affected

    Location

    Description

    Person(s)

    Notified

    Person(s)

    Title

    Photo

    Image

    No condition recorded

    Structural Engineer Required

    Structural

    Condition Type

    Condition

    Description

    Component

    Affected

    Location

    Description

    Person(s)

    Notified

    Person(s)

    Title

    Photo

    Image

    No condition recorded

    Accessibility

    Accessibility Status Question Response

    Is the Primary or secondary entrance on an accessible route? Yes

    Is the building a multi-story building? No

    Do any of the following spaces exist? Classroom, Art Room, Auditorium, Cafeteria,

    Computer, Gymnasiums, Library, Multipurpose Room, Science Labs

    No

    Are ALL occupied Spaces on the accessible route? Yes

    Are there accessible toilets In the building? No

    Physical Breakdown Structure Exists Complies Required DeficiencyAudio

    Induction

    System

    Fire

    Alarm

    Strobe

    FUNCTIONAL ACCESSIBILITY

    Exterior Routes

    YesExterior Entrances & Exits

    NoNoExterior H/C Lifts

    NoNoExterior Ramps and Railings

    Interior Routes

    NoNoCorridor and Lobby H/C Lifts

    YesYesInterior Corridor Doors And

    Hardware

    YesInterior Corridors & Lobbies

    NoInterior Elevators

    YesInterior Lobby Doors And Hardware

    NoInterior Ramps

    Rooms & Spaces

    NoArt Rooms

    NoAuditorium

    NoCafeteria

    NoClassrooms

    NoComputer Rooms

    NoGymnasium

    NoLibrary

    NoMain Office

    NoMulti-purpose Room

    NoNurse's Office

    NoPool

    NoScience Lab

    NoToilet Rooms (boys)

    NoToilet Rooms (girls)

    Toilet Rooms (staff)

    Page 2 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Physical Breakdown Structure Exists Complies Required DeficiencyAudio

    Induction

    System

    Fire

    Alarm

    Strobe

    Yes No1st Floor (Men's and

    Women's)

    INSUFFICIENT LATCH

    CLEARENCE

    WATER CLOSET

    ARRANGEMENT

    Building Template

    Inspection

    Question Response

    Architectural

    ATHLETIC FIELDS Does not exist

    EXTERIOR Inspected

    Does not existAREAWAY

    InspectedAWNINGS AND CANOPIES

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    Does not existCHIMNEY

    Does not existCOPING

    Does not existCORNICE

    InspectedDOORS

    InspectedDOOR HARDWARE

    Condition 3- Fair

    No deficiencies recordedDeficiency

    InspectedDOORS AND FRAMES

    Condition 4- Between Fair and Poor

    METAL:DETERIORATED DOOR AND FRAME - MAJOR

    DETERIORATION

    Deficiency

    Deficiency Location/Instance

    1Deficiency Quantity

    Page 3 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    EXTERIOR

    DOORS

    DOORS AND FRAMES

    Quantity Uom EACH

    Potential Action REPLACE

    PRIORITY 4Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Facade C

    Violations No violations recorded

    METAL:DETERIORATED DOOR - MINOR DETERIORATIONDeficiency

    Deficiency Location/Instance

    2Deficiency Quantity

    Quantity Uom EACH

    Potential Action MAINTENANCE

    PRIORITY 3Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Facade A

    Violations No violations recorded

    Does not existLINTELS

    Does not existTRANSOM/SIDE LIGHT

    Does not existEXTERIOR SOFFITS

    InspectedEXTERIOR WALLS

    SteelMaterial Type(s)

    4,000Replacement Quantity

    Replacement Uom S.F.

    Instance on All Facades Inspected

    4- Between Fair and PoorInstance Condition

    Instance Quantity 4,000

    Instance Quantity Uom S.F.

    METAL PANEL:DAMAGED TRIMDeficiency

    Page 4 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    EXTERIOR

    EXTERIOR WALLS

    Roof Plan Reference

    Elevation

    Elevation Reference Facade A

    25Deficiency Quantity

    Quantity Uom L.F.

    Potential Action REPLACE

    PRIORITY 4Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Facade C at Corner of Facade B

    Violations No violations recorded

    METAL PANEL:SEVERE DENTSDeficiency

    Roof Plan Reference

    Elevation

    Elevation Reference Facade A, B and D

    100Deficiency Quantity

    Quantity Uom S.F.

    Potential Action REPLACE

    PRIORITY 4Urgency of Action

    LEVEL 2Purpose of Action

    Page 5 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    EXTERIOR

    EXTERIOR WALLS

    Deficiency Photo 1

    Facade A

    Violations No violations recorded

    METAL PANEL:MINOR RUSTINGDeficiency

    Roof Plan Reference

    Elevation

    Elevation Reference Facade D

    80Deficiency Quantity

    Quantity Uom S.F.

    Potential Action MAINTENANCE

    PRIORITY 3Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Facade B

    Violations No violations recorded

    Does not existLOADING DOCK

    InspectedLOUVER

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    Does not existPARAPETS

    Does not existPLAZA DECK

    InspectedROOF

    InspectedROOFING

    Replacement Quantity 10,000

    Replacement Uom S.F.

    InspectedLEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS

    4- Between Fair and PoorCondition

    DAMAGED/MISSINGDeficiency

    Page 6 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    EXTERIOR

    ROOF

    ROOFING

    LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS

    Deficiency Location/Instance

    200Deficiency Quantity

    Quantity Uom L.F.

    Potential Action REPLACE

    PRIORITY 4Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Facade D

    Deficiency Photo 2

    Corner of Facade A and B

    Violations No violations recorded

    Does not existROOF BARRIER

    Does not existROOF CAGE

    Does not existROOF FENCE

    Does not existROOF HATCH/SMOKE HATCH

    InspectedROOFING

    Instance on Metal:Roof 1 Inspected

    1- GoodInstance Condition

    Instance Quantity 10,000

    Instance Quantity Uom S.F.

    “Does the roof have major mechanical equipment sitting on Dunnage

    Steel less than 18" above the Roofing?"

    No

    Installation Year 2016

    Source of Installation Year Documented

    No deficiencies recordedDeficiency

    Does not existROOFING DRAINS

    InspectedSPECIALTIES

    Does not existBULKHEAD/PENTHOUSE

    Does not existCUPOLA/ SPIRES/ TOWERS

    Does not existDORMER

    Does not existDUNNAGE STEEL

    Does not existROOF/GRAVITY TANK

    Page 7 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    EXTERIOR

    ROOF

    SPECIALTIES

    Does not existSKYLIGHT/ROOF VENT

    InspectedSTAIRS/RAMPS: EXTERIOR

    Does not existBUILDING CHEEK/FLANK WALLS

    Does not existRAILINGS

    InspectedSTAIRS/RAMPS

    Condition 3- Fair

    CONCRETE:CRACKS/SPALLING - MINORDeficiency

    Deficiency Location/Instance

    12Deficiency Quantity

    Quantity Uom S.F.

    Potential Action REPAIR

    PRIORITY 3Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Facade C

    Violations No violations recorded

    InspectedWINDOWS

    1,000Replacement Quantity

    Replacement Uom S.F.

    Does not existEXTERIOR GUARDS

    Does not existLINTELS

    InspectedWINDOWS

    Material Type(s) Aluminum

    Instance on Aluminum - Other:Facade B and D Inspected

    5- PoorInstance Condition

    Instance Quantity 1,000

    Instance Quantity Uom S.F.

    Installation Year 1966

    Source of Installation Year Inspector Estimate

    ALUMINUM - OTHER:DETERIORATEDDeficiency

    Roof Plan Reference

    Page 8 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    EXTERIOR

    WINDOWS

    WINDOWS

    Elevation

    Elevation Reference All Facades

    500Deficiency Quantity

    Quantity Uom S.F.

    Potential Action REPLACE WINDOW

    PRIORITY 5Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Room 101 - Facade B

    Violations No violations recorded

    ALUMINUM - OTHER:BROKEN PANEDeficiency

    Roof Plan Reference

    Elevation

    Elevation Reference Facade D

    5Deficiency Quantity

    Quantity Uom S.F.

    Potential Action MAINTENANCE

    PRIORITY 5Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Carpenter Shop

    Violations No violations recorded

    Page 9 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    INTERIOR Inspected

    Does not existAUDITORIUM

    Does not existCAFETERIA

    InspectedCLASSROOMS/CORRIDORS/ADMIN SPACES

    InspectedCeiling

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    InspectedDoor(s)

    Condition 3- Fair

    WOOD:DETERIORATED DOORDeficiency

    Room 101Deficiency Location/Instance

    1Deficiency Quantity

    Quantity Uom EACH

    Potential Action MAINTENANCE

    PRIORITY 3Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Room 101

    Violations No violations recorded

    InspectedFloor Finish

    Condition 2- Between Good and Fair

    CONCRETE:CRACKSDeficiency

    Room 117Deficiency Location/Instance

    25Deficiency Quantity

    Quantity Uom S.F.

    Potential Action REPLACE

    PRIORITY 3Urgency of Action

    LEVEL 2Purpose of Action

    Violations No violations recorded

    Does not existSpecialties

    InspectedWalls

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    Does not existGYMNASIUM

    InspectedINTERIOR DOOR HARDWARE

    Condition 3- Fair

    No deficiencies recordedDeficiency

    Does not existINTERIOR GUARDS

    Does not existKITCHEN

    Does not existLIBRARY

    Does not existLOCKER ROOM

    Does not existMULTI-PURPOSE ROOM

    Does not existPOOLS

    Does not existSCIENCE DEMO ROOM

    Does not existSCIENCE LAB

    Does not existSCIENCE PREP ROOM

    Does not existSHOWER ROOM

    Does not existSTAIRS/RAMPS: INTERIOR

    Page 10 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    INTERIOR

    InspectedSTRUCTURAL

    InspectedCOLUMNS/BEAMS/BEARING WALLS

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    InspectedFLOOR STRUCTURE

    Condition 3- Fair

    CONCRETE SLAB ON GRADE:MINOR CRACKSDeficiency

    1st FloorDeficiency Location/Instance

    75Deficiency Quantity

    Quantity Uom S.F.

    Potential Action REPAIR

    PRIORITY 3Urgency of Action

    LEVEL 5Purpose of Action

    Deficiency Photo 1

    Electrical Shop

    Violations No violations recorded

    InspectedFOUNDATION WALLS

    Material Type(s) Concrete

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    InspectedROOF STRUCTURE

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    Does not existVAULTS-BUNKERS

    InspectedTOILET ROOMS - STAFF

    InspectedCeiling

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    InspectedDoor(s)

    Condition 5- Poor

    METAL:DAMAGED LOUVERDeficiency

    Room H-4Deficiency Location/Instance

    1Deficiency Quantity

    Quantity Uom EACH

    Potential Action MAINTENANCE

    PRIORITY 3Urgency of Action

    LEVEL 2Purpose of Action

    Deficiency Photo 1

    Room H-4

    Violations No violations recorded

    Page 11 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)

  • NYC Department of Education

    Building Condition Assessment Survey 2019-2020

    R881Architectural Inspection

    Question Response

    INTERIOR

    TOILET ROOMS - STAFF

    InspectedFloor Finish

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    InspectedStalls

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    InspectedWalls

    Condition 2- Between Good and Fair

    No deficiencies recordedDeficiency

    Does not existTOILET ROOMS - STUDENTS

    LIFE SAFETY Inspected

    Does not existF.D. HOLDING AREA

    Does not existSTEEL STAIRS

    SITE Not required

    Page 12 of 12 Print Date: 9/11/2020Mobile Validity Version 2.0 (P)