PCU-N-LD 40

5
Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018. PCUNLD40TECHAU01.01 PRECISE CONTROL UNITS PCU-N-LD 40 Technical Data Airflow Supply Air 4000 l/s (nominal) Outside Air 0 - 100% as per project requirements Refrigeration Cooling Capacity Sized to project requirements Supply Air Moisture Content >5 g/kg dry air Cooling Stage 1 DX or CHW Coil (modulating) Cooling Stage 2 DX Coil (modulating) Reheat Stage Hot Gas Reheat Coil (modulating) Compressor Type Variable Speed Scroll (BLDC or PMSM Inverter) Refrigerant R-410A Reverse Cycle Available upon request Fans Type EC Plug Total Fans x4 (nominal selection*) Nominal Power 2.5 kW ea. (nominal selection*) Fan Diameter 350 mm (nominal selection*) Fan Speed (max.) 2970 RPM (nominal selection*) Motor Efficiency Class IE4 Ingress Protection Class IP54 Impeller Construction Non-metallic Composite Max. External Static Press. Approx. 1000 Pa @ 4000 l/s Speed Control Integrated Constant Volume Control or via External Speed Signal Supply Air Fans Type EC Axial Total Fans x4 (nominal selection ) Nominal Power 3.1 kW ea. (nominal selection ) Fan Diameter 800 mm (nominal selection ) Fan Speed (max.) 1100 RPM (nominal selection ) Motor Efficiency Class IE4 Ingress Protection Class IP54 Speed Control Integrated Head Pressure Control Electrical & Controls Electrical Input 415 V / 3 ph / 50 Hz Full Load Amps Refer to PCU-N-LD 40 electrical page Controls ClimaSync Control System included (refer to PCU ClimaSync page) Cabinet Weatherproof Yes Panel Construction 50 mm PIR Sandwich Panel (FM Approved 4880/4881 - Class 1) Panel Finish Colorbond “Surfmist” Panel R-Value 2.63 K.m 2 /W Panel Joiner Material UV Resistant Polymer Base Frame Galvanised Steel RHS with Lifting Lugs Condenser Configurations Split or Packaged Filter Section Optional with Split Configuration Optional with Packaged Configuration Filtration Grade As per project requirements Condenser Air * Supply air fan selection options are available. Condenser fan selection is dependent on the required DX cooling capacity. DX/CHW Coil DX Coil Reheat Coil Outside air and return air intake Air is precisely cooled to the required moisture content (>5g/kg dry air) Air is precisely reheated to the required dry-bulb temperature Contact your Air Change representative for a psychrometric unit selection Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz

Transcript of PCU-N-LD 40

Page 1: PCU-N-LD 40

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.PCUNLD40TECHAU01.01

PRECISE CONTROL UNITS

PCU-N-LD 40Technical Data

Airflow

Supply Air 4000 l/s (nominal)

Outside Air 0 - 100% as per project requirements

Refrigeration

Cooling Capacity Sized to project requirements

Supply Air Moisture Content >5 g/kg dry air

Cooling Stage 1 DX or CHW Coil (modulating)

Cooling Stage 2 DX Coil (modulating)

Reheat Stage Hot Gas Reheat Coil (modulating)

Compressor Type Variable Speed Scroll

(BLDC or PMSM Inverter)

Refrigerant R-410A

Reverse Cycle Available upon request

Fans

Type EC Plug

Total Fans x4 (nominal selection*)

Nominal Power 2.5 kW ea. (nominal selection*)

Fan Diameter 350 mm (nominal selection*)

Fan Speed (max.) 2970 RPM (nominal selection*)

Motor Efficiency Class IE4

Ingress Protection Class IP54

Impeller Construction Non-metallic Composite

Max. External Static Press. Approx. 1000 Pa @ 4000 l/s

Speed Control Integrated Constant Volume Control

or via External Speed Signal

Supp

ly A

ir

Fans

Type EC Axial

Total Fans x4 (nominal selection†)

Nominal Power 3.1 kW ea. (nominal selection†)

Fan Diameter 800 mm (nominal selection†)

Fan Speed (max.) 1100 RPM (nominal selection†)

Motor Efficiency Class IE4

Ingress Protection Class IP54

Speed Control Integrated Head Pressure Control

Electrical & Controls

Electrical Input 415 V / 3 ph / 50 Hz

Full Load Amps Refer to PCU-N-LD 40 electrical page

Controls ClimaSync Control System included

(refer to PCU ClimaSync page)

Cabinet

Weatherproof Yes

Panel Construction 50 mm PIR Sandwich Panel

(FM Approved 4880/4881 - Class 1)

Panel Finish Colorbond “Surfmist”

Panel R-Value 2.63 K.m2/W

Panel Joiner Material UV Resistant Polymer

Base Frame Galvanised Steel RHS with Lifting Lugs

Condenser Configurations Split or Packaged

Filter Section Optional with Split Configuration

Optional with Packaged Configuration

Filtration Grade As per project requirements

Cond

ense

r A

ir

* Supply air fan selection options are available. † Condenser fan selection is dependent on the required DX cooling capacity.

DX/CHW Coil DX Coil Reheat Coil

Outside air and return air intake

Air is precisely cooled to the required

moisture content (>5g/kg dry air)

Air is precisely reheated to the

required dry-bulb temperature

Contact your Air Change representative for a psychrometric unit selection

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz

Page 2: PCU-N-LD 40

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.PCUNLD40TECHAU01.01

PRECISE CONTROL UNITS

PCU-N-LD 40Dimensions

Indicative Packaged Configuration Dimensions

Required DX Cooling Capacity80 kWr

(1st stage CHW)130 kWr

(full DX system)180 kWr

(full DX system)

Overall Depth (mm) 3750 4400 4700

Body Depth (mm) 3550 4200 4500

Overall Width (mm) 2300 2300 2300

Body Width (mm) 2300 2300 2300

Overall Height (mm) 2150 2250 2300

Body Height (mm) 1700 1850 1850

Weight (kg) 2250

* Dimensions and weight are subject to change, depending on the required DX cooling capacity, design conditions, and other project requirements. Refer to project certified drawings for finalised details.

Bod

y W

idth

Body Depth

Overall Depth

Ove

rall

Wid

th

PLAN VIEW

Min LHS Clearance:800mm

Min RHS Clearance:800mm

Fan & CoilAccess

Bod

y H

eigh

t

Ove

rall

Hei

ght

SA Spigot550 1770

CompressorAccess

CondenserCoil

Spigot size & location can be revised accordingto project requirements (within design limitations)

150

CondenserAccess

50

SA Spigot1400

120

OA

& R

A

Spig

ot 1

345

215

OA & RA Spigot 1550

RIGHT SIDE VIEW BACK VIEWFRONT VIEW

Packaged Configuration (Optional Filter Section Not Shown)*

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz

Page 3: PCU-N-LD 40

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.PCUNLD40TECHAU01.01

PRECISE CONTROL UNITS

PCU-N-LD 40Dimensions

Overall Depth2600

Body Depth2400

Body

Wid

th23

00

Ove

rall

Wid

th23

00

PLAN VIEW

Min LHS Clearance:800mm

Min RHS Clearance:800mm

Fan & CoilAccess

Pipe Connections

Ove

rall

Hei

ght

1800

Body

Hei

ght

1700

Compressor Access

100

SA Spigot900

350

SA S

pigo

t90

0

400

Spigot size & location can be revised according to project requirements (within design limitations)

50

OA & RA Spigot1550

140

OA

& R

A

Spig

ot 1

340

RIGHT SIDE VIEW BACK VIEWFRONT VIEW

Overall Width

Ove

rall

Dep

th

Min Back Clearance:500mm

Min LHS Clearance:500mm

Min Front Clearance:500mm

Body

Hei

ght

Ove

rall

Hei

ght

Pipe Connections

PLAN VIEW

FRONT VIEWLEFT SIDE VIEW

Indicative Condensing Unit Dimensions

Required DX Cooling Capacity80 kWr

(1st stage CHW)130 kWr

(full DX system)180 kWr

(full DX system)

Overall Depth (mm) 1500 1400 1550

Overall Width (mm) 2300 3900 4600

Overall Height (mm) 1400 1350 1400

Body Height (mm) 1100 1100 1100

Weight (kg) 900

* Dimensions and weight are subject to change, depending on the required DX cooling capacity, design conditions, and other project requirements. Refer to project certified drawings for finalised details.

Indicative AHU weight: 1350

Split Configuration AHU (Optional Filter Section Not Shown)*

Split Configuration Condensing Unit*

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz

Page 4: PCU-N-LD 40

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.PCUNLD40TECHAU01.01

PRECISE CONTROL UNITS

PCU-N-LD 40Electrical

Indicative Electrical Input details†

Required DX Cooling Capacity80 kWr (1st stage CHW) 130 kWr (full DX system) 180 kWr (full DX system)

Voltage / Phases / Frequency 415 V / 3 ph / 50 Hz 415 V / 3 ph / 50 Hz 415 V / 3 ph / 50 Hz

Full Load Amps 86 A 158 A 158 A

*Connection details are subject to change, depending on project requirements. Refer to project certified electrical diagrams for finalised details.†Power details are subject to change, depending on the required DX cooling capacity and other project requirements. Refer to project certified electrical diagrams for finalised details.

Wiring Diagram — Packaged Configuration*

Wiring Diagram — Split Configuration*

Electrical Input

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz

Page 5: PCU-N-LD 40

Air Change Australia Pty Ltd accept no responsibility for possible errors in catalogues, brochures and other printed material. Air Change Australia Pty Ltd reserves the right to alter its products without notice. © Air Change Australia Pty Ltd 2018.PCUNLD40TECHAU01.01

PRECISE CONTROL UNITS

PCU-N-LD 40Airflow & Noise

4000l/s @ 300Pa External Static Pressure Inlet

Frequency (Hz) sum 63 125 250 500 1000 2000 4000 8000

A-weighted (dB) 82 45 55 76 76 73 75 71 68

Non A-weighted (dB) 86 71 70 84 79 73 74 70 69

Outlet

Frequency (Hz) sum 63 125 250 500 1000 2000 4000 8000

A-weighted (dB) 87 47 58 77 77 83 81 77 72

Non A-weighted (dB) 89 73 73 85 80 83 80 76 73 † Noise data considers supply air fans only, excluding compressor noise and condenser fan noise. Noise attenuation by the cabinet is also not

considered. Filter pressure drop to be factored into the 300Pa external static pressure.

* Fan curve makes allowance for internal pressure drop of unit (excluding filters). This pressure drop is subject to change, depending on project requirements. Supply air fan selection options are available.

Supply Air Fan Curve*

Supply Air Fan Acoustics (Sound Power)†

0

200

400

600

800

1000

1200

1400

1600

0 1000 2000 3000 4000 5000 6000

Exte

rnal

Sta

tic P

ress

ure

(Pa)

Airflow (l/s)

2970 RPM (Max.) 2249 RPM (4000 l/s @ 300 Pa external static pressure)

Max.airflow

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz