PCU User Manual(06)

download PCU User Manual(06)

of 33

Transcript of PCU User Manual(06)

  • 7/22/2019 PCU User Manual(06)

    1/33

    PCU

    User Manual

    Issue 06

    Date 2013-10-23

    HUAWEI TECHNOLOGIES CO., LTD.

  • 7/22/2019 PCU User Manual(06)

    2/33

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    i

    Copyright Huawei TECHNOLOGIES Co., Ltd. 2013. All rights reserved.

    No part of this document may be reproduced or transmitted in any form or by any means without prior

    written consent of Huawei Technologies Co., Ltd.

    Trademarks and Permissions

    and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.

    All other trademarks and trade names mentioned in this document are the property of their respective

    holders.

    Notice

    The purchased products, services and features are stipulated by the contract made between Huawei and

    the customer. All or part of the products, services and features described in this document may not be

    within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,

    information, and recommendations in this document are provided "AS IS" without warranties, guaranteesor representations of any kind, either express or implied.

    The information in this document is subject to change without notice. Every effort has been made in the

    preparation of this document to ensure accuracy of the contents, but all statements, information, and

    recommendations in this document do not constitute the warranty of any kind, express or implied.

    Huawei Technologies Co., Ltd.

    Address: Huawei Industrial Base

    Bantian, Longgang

    Shenzhen 518129

    People's Republic of China

    Website: http://www.huawei.com

    Email: [email protected]

    http://www.huawei.com/mailto:[email protected]:[email protected]://www.huawei.com/
  • 7/22/2019 PCU User Manual(06)

    3/33

    PCU

    User Guide About This Document

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    ii

    About This Document

    Overview

    This document describes the PCU overview, installation, operation and maintenance to users.

    Intended Audience

    This user manual is mainly applicable to the following engineers:

    Technical support engineer

    Maintenance engineer

    Changes History

    06 (2013-10-23)It is the sixth official release. Compared with the fourth release, the following contents in this

    document are modified:

    Topic Description

    Routine Maintenance Add the disconnection description after finishing control operationof RCU.

    05 (2013-08-13)

    It is the fifth official release. Compared with the fourth release, the following contents in thisdocument are modified:

    Topic Description

    Logo Change to huawei logo

    Product specification Modify the product weight

    04 (2013-06-08)

  • 7/22/2019 PCU User Manual(06)

    4/33

    PCU

    User Guide About This Document

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    iii

    It is the fourth official release. Compared with the third release, the following contents in this

    document are modified:

    Topic Description

    Scenarios Add the operation description after the PCU is used as aUSB/AISG adapter.

    Routine Maintenance Add the operation description when the battery is self-protective.

    03 (2013-01-06)

    It is the third official release. Compared with the second release, the following contents in this

    document are modified:

    Topic Description

    Product SpecificationSpecification of power supply and rechargeable battery in Table 1-1 has been updated.

    AppearanceFigure 1-1 has been updated, and silk-screen of indicator lightshas been specified.

    Packing List Specification of AC/DC adapter in Table 2-1 has been updated.

    InstallationThe installation steps have been updated when PCU is used as aUSB/AISG adapter.

    Mode SwitchThe operation of switch PCU as a USB/AISG adapter has beenspecified.

    02 (2012-05-15)

    It is the second official release. Compared with the initial release, the following contents in

    this document are modified:

    Topic Description

    Storage temperature It has been updated to be -30 to +65.

    Installation Some details have been updated.

    01 (2011-11-26)

    It is the initial release.

  • 7/22/2019 PCU User Manual(06)

    5/33

    PCU

    User Guide Contents

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    iv

    Contents

    1 Product Introduce .......................................................................................................................... 11.1 Overview ................................................................. .................................................................. ....................... 11.2 Product Specification ................................................................................................................ ....................... 11.3 Appearance .............................................................. .................................................................. ....................... 2

    1.3.1 PCU ................................................................ .................................................................. ....................... 21.3.2 Accessory ................................................................... ................................................................. ............ 4

    2 Installation...................................................................................................................................... 62.1 Preparations ............................................................. .................................................................. ....................... 62.2 Scenarios ................................................................. .................................................................. ....................... 6

    2.2.1 PCU is used as a RCU controller ................................................................ ............................................ 62.2.2 PCU is used as a USB/AISG adapter .......................................................... ............................................ 7

    2.3 Installation ............................................................... .................................................................. ....................... 92.3.1 PCU is used as a RCU controller ................................................................ ............................................ 92.3.2 PCU is used as a USB/AISG adapter .......................................................... ............................................ 92.3.3 COM port confirmation ............................................................................. ........................................... 11

    3 Operation ...................................................................................................................................... 123.1 System Setup ........................................................... .................................................................. ..................... 12

    3.1.1 Language Setup .......................................................... ................................................................. .......... 123.1.2 Battery Save ............................................................... ................................................................. .......... 133.1.3 Mode Switch ......................................................................................................... ................................ 13

    3.2 Scan .............................................................. .................................................................. ................................ 133.3 Calibrate .................................................................. .................................................................. ..................... 143.4 Tilt Control .............................................................. .................................................................. ..................... 15

    3.4.1 Get Tilt ........................................................... .................................................................. ..................... 163.4.2 Set Tilt ............................................................ .................................................................. ..................... 163.4.3 Self Test ......................................................... .................................................................. ..................... 17

    3.5 Information acquire ............................................................. ................................................................. .......... 173.5.1 Get Info ................................................................................................................. ................................ 183.5.2 Get DevData ......................................................................................................................................... 183.5.3 Reset Software ...................................................................................................... ................................ 20

    3.6 Alarm Manage ......................................................... .................................................................. ..................... 203.6.1 Get Status ................................................................... ................................................................. .......... 21

  • 7/22/2019 PCU User Manual(06)

    6/33

    PCU

    User Guide Contents

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    v

    3.6.2 Clear Alarms .............................................................. ................................................................. .......... 213.7 Battery Indicator .................................................................. ................................................................. .......... 21

    4 Maintenance ................................................................................................................................. 234.1 Routine Maintenance...................................................................................................................................... 234.2 RCU Troubleshooting .................................................................................................... ................................ 244.3 PCU Troubleshooting .......................................................... ................................................................. .......... 24

    A Appendix ..................................................................................................................................... 26A.1 Abbreviations ......................................................... .................................................................. ..................... 26A.2 Return Codes and Alarm Codes .................................................... ................................................................ 26A.3 Suitable RCU Models .................................................................... ................................................................ 27

  • 7/22/2019 PCU User Manual(06)

    7/33

    PCU

    User Guide 1 Product Introduce

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    1

    1 Product Introduce1.1 Overview

    PCU is a portable control unit for RET (Remote Electrical Tilt) antennas. It supports AISG 1.1and AISG 2.0 protocol. It can be used to power and control the RCU (Remote Control Unit)

    of tilt adjustable antennas. This product is an easy-to-carry controller with a built-inrechargeable battery. It can also be used as a PCA (Portable Control Adapter) for USB/AISG.

    It is suitable for in-site installation, tilting and maintenance of tilt adjustable antennas.

    Only some specified RCU models of Huawei are supported by PCU. Those RCUs are listed inthe appendix.

    1.2 Product SpecificationThe product specification of PCU is listed in Table 1-1.

    Table 1-1PCU product Specification

    Electric specification

    Power supplyInput: 100~240V AC, 0.7A~1.0A, 50-60HzOutput: 20V DC 1.5A(AC/DC adapter)/16V DC 1.5A (rechargeable

    battery)

    Rechargeable

    batteryLi-Polymer (16V 2000mAh), > 300 cycles

    AISG connectorAISG Female (8pin) x 2, comply

    with IEC 60130-9

    Pin 1, Pin 6 DC(+20V)(AC/DC adapter)DC(+16V)(rechargeable battery)

    Pin 3 RS485 B

    Pin 5 RS485 A

    Pin 7 DC return

    Environment specification

    Operating

    temperature10to +55

    Storagetemperature

    30to +65

  • 7/22/2019 PCU User Manual(06)

    8/33

    PCU

    User Guide 1 Product Introduce

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    2

    Storage humidity 5% ~ 95%

    Life 3 years

    Mechanism specification

    Weight 0.45 kg(with rechargeable battery)

    Dimensions 168mm x 90mm x 44mm

    Material ABS

    1.3 Appearance

    1.3.1 PCU

    Figure 1-1 shows the front, side and bottom views of PCU.

    Figure 1-1 PCU appearance

  • 7/22/2019 PCU User Manual(06)

    9/33

    PCU

    User Guide 1 Product Introduce

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    3

    (1) AISG connector (2) Strap hole (3) Power switch

    (4) USB connector (5) LCD display (6) Indicator light

    (7) Keyboard (8) AC/DC adapter input

    AISG Connector

    It connects RCU if PCU is used to directly control RCU to realize the tilt adjustable function

    of antenna. It also can connect RCU if PCU is used as USB/AISG control adapter, and PCsoftware is running to realize the configuration file and the RCU software updating or AISGprotocol version switching function of RCU.

    This connector is AISG Female, conforming to IEC 60130-9, its specification in0.

    Strap Hole

    This is used to fix the shoulder strap to facilitate being carried.

    Power Switch

    This is for power PCU on/off.

    USB Connector

    It connects PC with USB cable if PCU is used as USB/AISG control adapter. USB connector

    is a USB A type plug.

    LCD Display

    LCD Display shows menus and operating results while using PCU to control RCU.

    It is a 128 x 64 dot-matrix LCD display with yellow-green backlight, which supports 4 rows x

    8 Chinese characters or 16 characters at one page at most.

    Indicator Light

    There are 3 lights indicating the power, connection and communication status if PCU is used

    as a USB/AISG adapter. Their function is listed as Table 1-2.

    Table 1-2 Indicator lights

    SNO. Light Color Function Description

    1 Red(Power) If power on, the red light keeps on. It indicates the power state.

    2 Green(RUN)If USB/AISG module works well during communication between

    PC and RCU, the Green light twinkles. It indicates PCU is in agood communication working state.

    3 Yellow(USB)If USB connector connects to PC with USB cable, the Yellow light

    keeps on. It indicates PCU is successfully identified as a

    USB/AISG adapter by PC and is available.

  • 7/22/2019 PCU User Manual(06)

    10/33

    PCU

    User Guide 1 Product Introduce

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    4

    Keyboard

    Keyboard is for input during operation.

    There are 5 keys in the keyboard of PCU, and their function is listed as Table 1-3.

    Table 1-3 Keys

    SNO. Key Name Function Description

    1 UPTo move the cursor up in a menu or increase the tilt value if setting

    tilt.

    2 DOWNTo move the cursor down in a menu or decrease the tilt value ifsetting tilt.

    3 SYS To jump to the system menu.

    4 ENTERTo initiate the selected operation in a menu or start to set theappointed tilt value if setting tilt.

    5 ESC To escape the current menu or page, and return the previous.

    AC/DC Adapter Input Port

    It is for the input of AC/DC Adapter.

    Once PCU is charged by AC/DC Adapter, it will automatically switch to use the outsidepower supply as power source and charge the built-in battery if not full of power.

    1.3.2 Accessory

    The accessory of PCU is consisted of the AC/DC adapter, the AISG cable, the USB cable and

    the User Guide.

    AC/DC Adapter

    Figure 1-2 shows the appearance of AC/DC adapter, for more detail in Table 2-1.

    Figure 1-2AC/DC adapter appearance

    AISG Cable

    Figure 1-3 shows the appearance of AISG cable, for more detail in Table 2-1.

  • 7/22/2019 PCU User Manual(06)

    11/33

    PCU

    User Guide 1 Product Introduce

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    5

    Figure 1-3AISG cable appearance

    USB Cable

    Figure 1-4 shows the appearance USB cable, for more detail in Table 2-1, the connector is

    USB standard A type plug.

    Figure 1-4 USB cable appearance

  • 7/22/2019 PCU User Manual(06)

    12/33

    PCU

    User Guide 2 Installation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    6

    2 Installation2.1 Preparations

    Before using the PCU, users need to check about packing list and prepare tools.

    PCU and its accessory are listed in Table 2-1.

    Table 2-1PCU packing list

    Product Name Qty Description

    PCU 1 PCS More detail in0 PCU product Specification

    AC/DC Adapter 1 PCSInput: 100~240V,AC,0.7A~1.0A,50-60HzOutput: 20V DC,1.5A

    AISG Cable 1 PCS AISG(male)-AISG(female), 2m

    USB Cable 1 PCS USB(A type plug)-USB(A type plug), 1.5m

    User Guide 1 PCS User Manual

    Generally, PCU is used together with RCU. If RCU does not finish installing at site, pleaseprepare for tools according to RCU installment manual.

    The battery of PCU is provided only by manufacturer appointed by Huawei, if any

    requirement of replacing a battery, please contact our technical support for help.

    If a PC software named as PCU PC-Tool is necessary, which supports some function thatPCU cannot support, such as send configuration files to RCU, download a new firmware to

    RCU or switch the protocol version of RCU, please make sure PCU PC-Tool has beeninstalled on your PC.

    PCU PC-Tool can be obtained athttp://support.huawei.com/support/.

    2.2 Scenarios

    2.2.1 PCU is used as a RCU controller

    PCU can be used as a simple controller under condition of site installation or maintenance. Insuch scenarios, PCU control RCU directly as Figure 2-1.

    http://support.huawei.com/support/http://support.huawei.com/support/http://support.huawei.com/support/http://support.huawei.com/support/
  • 7/22/2019 PCU User Manual(06)

    13/33

    PCU

    User Guide 2 Installation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    7

    Figure 2-1 Scenario of PCU as a RCU controller

    (1) RET Antenna (2) RCU (3) RF Feeder Cable

    (4) AISG Cable (5) Site (6) PCU

    (7) AC/DC Adapter

    With the AISG connector connecting to RCU, PCU is used as a RCU controller to scan RCU,

    and do operations such as calibrate, get/set tilt, get information or device data (hardware andsoftware version, antenna model type, antenna bands, beamwidth, gain, adjustable tilt range,and bearing), get/clear alarm, and the results of those operations is available by LCD display.

    1. The maximum number of RCUs controlled by PCU and the amount of AISG cable length depend on

    losses suffered along the cables. A maximum of 6 RCUs and 50m of AISG cable is acceptable.

    2. Following device information can be available after user setup: antenna model number, antenna bands,beamwidth, gain, and bearing.

    2.2.2 PCU is used as a USB/AISG adapter

    PCU can be used as a USB/AISG adapter under condition of site maintenance or special test.

    In such scenarios, PC software control RCU though PCU as Figure 2-2.

  • 7/22/2019 PCU User Manual(06)

    14/33

    PCU

    User Guide 2 Installation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    8

    Figure 2-2Scenario of PCU as a USB/AISG adapter

    (1) RET Antenna (2) RCU (3) RF Feeder Cable

    (4) AISG Cable (5) Site (6) PCU

    (7) AC/DC Adapter (8) USB Cable (9) PC

    With the AISG connector connecting to RCU while USB connector to PC, PCU is used as a

    USB/AISG adapter if switching mode. PC software (PCU PC-Tool) can be run to scan RCU,and do operations such as calibrate, get/set tilt, send or update configuration files and RCU

    softwares, switch AISG protocol version of RCU, etc. More detail of PC software is supported

    by technical support engineers of Huawei.

    1. The maximum number of RCUs controlled by PCU and the amount of AISG cable length dependon losses suffered along the cables. A maximum of 6 RCUs with 50m of AISG cable is acceptable.

    2. After is used as a USB/AISG adapter, the PCU must be restarted and then it can do other works.

  • 7/22/2019 PCU User Manual(06)

    15/33

    PCU

    User Guide 2 Installation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    9

    2.3 Installation

    2.3.1 PCU is used as a RCU controller

    Step 1 Connect AISG connector of PCU to RCU with AISG cable as Figure 2-3.

    Figure 2-3AISG cable connection if PCU as a RCU controller

    Step 2 Switch on PCU and the red light (Power) will be on, it indicates that PCU has been power-on.If Low Batterydisplays on LCD screen or the battery indicator at top-right of LCD screen

    is at low level, charge the battery by AC/DC adapter provided.

    Step 3 Press ENTERto scan RCU, and validate the connection of AISG cable between PCU andRCU, and connection of AISG cable between RCUs if in daisy chain.

    2.3.2 PCU is used as a USB/AISG adapter

    Step 1 Connect AISG connector of PCU to RCU with AISG cable as Figure 2-4.

  • 7/22/2019 PCU User Manual(06)

    16/33

    PCU

    User Guide 2 Installation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    10

    Figure 2-4 AISG and USB cable connection if PCU as a USB/RS458 adapter

    Step 2 Turn on the switch and the red light (Power) will be on, it indicates that PCU has been power-on.

    Step 3 Connect USB connector to PC with USB cable as Figure 2-4. If the yellow light (USB) on, itindicates PCU is successfully identified as a USB/AISG adapter by PC.

    There is a protective lid covered on the USB connector, please push it aside carefully to avoid being

    broken.

    Step 4 Switch to USB/AISG mode to enable the USB/AISG adapter function of PCU, more detailrefers to 3.1.3 Mode Switch.

    Step 5 Run PC software to scan RCU, and validate the connection of AISG cable between PCU andRCU, and connection of AISG cable between RCUs if in daisy chain. If the green light (RUN)

    twinkles, it indicates the USB/AISG module of PCU works well during communicationbetween PC and RCU.

  • 7/22/2019 PCU User Manual(06)

    17/33

    PCU

    User Guide 2 Installation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    11

    2.3.3 COM port confirmation

    A suitable COM port needs to choose before running PC software which uses the PCU as a

    USB/AISG adapter. The mapped COM port of PCU is confirmed as following in WindowsXP/Windows 7.

    Step 1 Open Device Managerby Windows Start menu > My Computer (right-click) > Properties >Hardware > Device Manage in Windows XP, or by Windows Start menu > My Computer(right-click) > Properties > Device Manage in Windows 7.

    Step 2 Click of Ports (COM &LPT)to confirm CP210x USB to UART Bridge Controller(COM*)is displayed as Figure 2-5 in Windows XP or Figure 2-6 in Windows 7. *is the

    COM port number that is used for the communication setting with the utility software.

    Figure 2-5COM port confirmation in Windows XP if PCU as a USB/RS458 adapter

    Figure 2-6 COM port confirmation in Windows 7 if PCU as a USB/RS458 adapter

  • 7/22/2019 PCU User Manual(06)

    18/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    12

    3 OperationWith switching on and the AISG connector connecting to RCU, PCU is used as a RCUcontroller to scan RCU, and do operations such as calibrate, get/set tilt, get information or

    device data (hardware and software version, antenna model type, antenna bands, beamwidth,gain, adjustable tilt range, and bearing), get/clear alarm, and the results of those operations isavailable by LCD display.

    3.1 System Setup

    If switching on and full of battery power, the start page of PCU shows as following.

    It is recommended to setup the system of PCU before its first operation.

    If press SYS under start page or other menu/page, LCD screen will display the system setup

    menu as following.

    OR

    3.1.1 Language Setup

    If press UP/DOWNto select 2.Languageor under system setup menu and press

    ENTER, it will turn into language menu as following.

    OR

  • 7/22/2019 PCU User Manual(06)

    19/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    13

    Press UP/DOWNto select 1.Englishand press ENTER, it will return to system setup menu

    as following.

    3.1.2 Battery Save

    If press UP/DOWNto select 3.Battery Saveunder system setup menu and press ENTER, itwill turn into battery save setup menu as following.

    Press UP/DOWNto select 1.Onand press ENTER, it will return to system setup menu as

    following.

    If ON, the backlight of LCD screen will automatically turn off to save battery power if there is no key-press more than 10s; if OFF, the backlight will always turn on.

    3.1.3 Mode Switch

    If press UP/DOWNto select 4.Data Operateunder system setup menu and press ENTER,it will enable USB/AISG adapter function and turn into page as following.

    Press ESCto return to start page if under such page and the USB/AISG adapter function has

    been disable.

    3.2 Scan

    If press ENTERunder start page, or select 1.Scan Deviceand press ENTERunder system

    setup menu, it will initiate a scanning process to find out all connected RCUs. LCD screen

    displays as following.

  • 7/22/2019 PCU User Manual(06)

    20/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    14

    It will cease if keep pressing ESCfor several seconds during scanning.

    If there is no scanned RCU, it will display below.

    Press ESCto return start page, or press ENTERto scan again.

    If more than 1 RCUs have been scanned, it will turn to device list menu. Take 2 RCUs for

    example, the page shows below.

    Press UP/DOWNto select a RCU for further operation, and press ENTERto turn to maincontrol menu as following.

    3.3 Calibrate

    If press UP/DOWNto select 1.Calibrateunder main control menu, it displays as following:

    Press ENTER, it will initiate a calibration and the LCD screen displays as following.

    Counter of scanned RCUs

    Supported AISG version of selected RCU(AISG1.1/2.0)

    Sequence No. and Unique ID of selected RCU

  • 7/22/2019 PCU User Manual(06)

    21/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    15

    If successfully, it displays as following.

    If unsuccessfully, it displays as following.

    Press UP/DOWNto see the return code about the reason of failure as following.

    Press ENTERto view the explanation of selected return code as following.

    More information about return code and alarm code are available in appendix.

    3.4 Tilt Control

    If press UP/DOWNto select 2.Tilt Controlunder main control menu, it displays as

    following:

    Press ENTER, it will turn to tilt control menu.

  • 7/22/2019 PCU User Manual(06)

    22/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    16

    Press UP/DOWNto select a control operation, and press ENTERto initiate.

    Please confirm the RCU has been calibrated or not, if not please do the calibration again.

    3.4.1 Get Tilt

    If press UP/DOWNto select 1.Get Tiltunder tilt control menu and press ENTER, it will

    initiate an operation of tilt acquirement.

    If successfully, it displays as following.

    If unsuccessfully, it displays as following.

    Please do a calibration to clear this fault or find out the reason of this fault if in such case.

    3.4.2 Set Tilt

    If press UP/DOWNto select 2.Set Tiltunder tilt control menu and press ENTER, it will

    turn to set tilt page as following.

    Press UP/DOWNto increase or decrease the target tilt value by 0.5, and press ENTERtoinitiate an operation of tilting, it displays as following.

  • 7/22/2019 PCU User Manual(06)

    23/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    17

    If successfully, it displays as following.

    If unsuccessfully, it displays as following.

    Please do a calibration to clear this fault or find out the reason of this fault if in such case.

    3.4.3 Self Test

    If press UP/DOWNto select 3.Self Testunder tilt control menu and press ENTER, it willinitiate an operation of self testing and displays as following.

    If successfully, it displays as following.

    If unsuccessfully, it displays as following.

    Refer to Section 3.3 about how to view the return code. More information about return codeand alarm code are available in the appendix.

    3.5 Information acquire

    If press UP/DOWNto select 3.Get Infounder main control menu, it displays as following:

  • 7/22/2019 PCU User Manual(06)

    24/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    18

    Press ENTER, it will turn to info acquire menu as following.

    3.5.1 Get Info

    If press UP/DOWNto select 1.Get Infounder info acquire menu and press ENTER, it will

    initiate an operation of information acquirement, then the software and hardware version of

    RCU shows as following.

    3.5.2 Get DevData

    If press UP/DOWNto select 2.Get DevDataunder info acquire menu and press ENTER, it

    will turn to device data menu as following.

    This menu will be self-roll, and it will diplay as following if press DOWNto select 6.Ant

    Bearing.

    Press UP/DOWNto select an expected device data, and press ENTERto initiate an acquiringoperation.

    Antenna Model

    If select 1.Antenna Modeland press ENTER, it will initiate an acquirement of antenna

    model number, and the result shows below.

    Software version of selected RCU

    Hardware version of selected RCU

  • 7/22/2019 PCU User Manual(06)

    25/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    19

    Operating Band

    If select 2.Operating Bandand press ENTER, it will initiate an acquirement of antenna

    operating bands, and the result shows below.

    If 4 bands returns, it only display frequency bands as following:

    The operating band displayed is defined in 3GPP, refer to the actual band by the specification of antenna.

    Beamwidth

    If select 3.Beamwidthand press ENTER, it will initiate an acquirement of beamwidth ofeach operating bands, and the result shows below.

    If 4 bands returns, it only display frequency bands and beamwidth of each band as following:

    Gain

    If select 4.Gainand press ENTER, it will initiate an acquirement of gain of each operating

    bands, and the result shows below.

  • 7/22/2019 PCU User Manual(06)

    26/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    20

    If 4 bands returns, it only display frequency bands and gain of each band as following:

    Adjust Scope

    If select5.Adjust Scopeand press ENTER, it will initiate an acquirement of the minimum

    and maximal tilt value supported by the antenna and the result shows below.

    Ant Bearing

    If select 6.Ant Bearingand press ENTER, it will initiate an acquirement of antenna bearing,

    and the result shows below.

    3.5.3 Reset SoftwareIf press UP/DOWNto select 3.Reset Softwareunder info acquire menu and press ENTER,it will initiate an operation of reset software, and the result shows below if successfully.

    If any RCU alarm is found, please try to reset by this operation to affirm it is a permanent fault or not.

    3.6 Alarm Manage

    If press UP/DOWNto select 4.Alarmunder main control menu, it displays as following:

    Press ENTER, it will turn to alarm manage menu as following.

  • 7/22/2019 PCU User Manual(06)

    27/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    21

    3.6.1 Get Status

    If press UP/DOWNto select 1.Get Statusunder alarm manage menu and press ENTER, it

    will initiate an acquirement of active alarms.

    If there is no active alarm it display as following.

    If there is some active alarms it display as following.

    Refer to Section 3.3 about how to view the return code. More information about return code

    and alarm code are available in the appendix.

    3.6.2 Clear Alarms

    If press UP/DOWNto select 2.Clear Alarmsunder alarm manage menu and press ENTER,it will initiate an operation to clear all active alarms, and the result shows below.

    If any RCU alarm is found, please try to clear by this operation to affirm it is a permanent fault or not.

    3.7 Battery Indicator

    If PCU is used as a RCU controller in the case of no external power source, please make sure

    there is enough battery power.

    Battery indicator at top-right of LCD screen indicates the current battery power lever as inTable 3-1.

    Table 3-1Battery indicator

    SNO. Battery indicator Description

  • 7/22/2019 PCU User Manual(06)

    28/33

    PCU

    User Guide 3 Operation

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    22

    1 >80%

    2 50%-80%

    3 20%-50%

    4

  • 7/22/2019 PCU User Manual(06)

    29/33

    PCU

    User Guide 4 Maintenance

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    23

    4 Maintenance4.1 Routine Maintenance

    During the operation and maintenance of PCU, please pay attention to the battery, LCDdisplay and appearance of the shell.

    Battery

    The rechargeable battery is Li-polymer within the electrolyte. Improper use may shorten its

    life, even a security risk.

    1. Do not over-charge or over-discharge the battery, it may shorten its life.

    2. Please charge and discharge at least every 1~2 month even if no use for a long time.

    3. Please preserve the AC/DC adapter packed together with PCU carefully, and charge PCU

    only by this specifically adapter.

    4. Please check the battery power and charge it if PCU will be used in a condition withoutexternal power supply.

    5. Do not use or leave PCU near the hot heat source such as fire or heaters, it is easy tocause the battery to overheat, be short or loss its function, and shorten its life.

    6. Do not use PCU in a location where static electricity or magnetic field is great, otherwisethe safety devices of battery may be damaged to bring security risks.

    7. If the battery gives off an odor, overheat, becomes discolored or deformed, or in any wayappears abnormal during use, recharging or storage, immediately remove it from PCUand stop use it.

    Be aware of that discharged batteries may cause fire, tape the terminals to insulate them.

    8. If it is less than 1 hours to charge full, or less than 0.5 hours to warn low power, pleaseremove this battery as it may loss its function.

    9. The PCU battery can be self-protective, when the PCU is blank screen and can t berestarted, please reconnect the adapter.

    LCD Display

    The LCD display of PCU may be abnormal if improper use.

    1. Do not exposure the LCD display to direct sunlight or ultraviolet light for a long time.

  • 7/22/2019 PCU User Manual(06)

    30/33

    PCU

    User Guide 4 Maintenance

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    24

    2. Avoid being extruded, stricken, hit or scratched by sharp objects.

    3. Do not use PCU in a location of high temperature or great static magnetic field.

    Appearance Shell

    The shell is made of ABS, easy to be damaged or scratched if improper use.

    1. Do not drop, throw or hit during carrying or operating.

    2. Do not use PCU outdoor during a light storm.

    3. Please pack PCU well if need to use it at the top of a tower or site, such as fix PCU by itsstrap hole or carry it by bag.

    4. Cover the AISG connector and USB connector with their protective lids to preventexternal objects into the PCU.

    5. Please remove the AISG cable between PCU and RCU after finish operation, and avoididle connection status without operation.

    4.2 RCU Troubleshooting

    If PCU is used as a RCU controller, RCU alarm status is available by alarm acquirement

    function of PCU. More information about return code is available in appendix A.2 return

    code and alarm code.

    If PCU is used as a USB/AISG adapter, more information about RCU alarm status is available

    by manual of PC software (PCU PC-Tool). Please contact Huawei technical support for more

    detail.

    Once find RCU alarms or fault, please refer to Huawei RCU Troubleshooting, which can be

    obtained athttp://support.huawei.com/support/.

    4.3 PCU Troubleshooting

    Battery

    1. If it is less than 1 hours to charge full, or less than 0.5 hours to warn low power, thisbattery may loss its function, please remove it and use a new one.

    2. If the battery indicator is static during charging, the battery may fail to charge, pleaseremove it and use a new one.

    3. Switch on and charge PCU, but red light (Power) is still off and no display on LCD, nooutput power at AISG connector, the battery or power supply module is fault. Pleaseinspect inside after teardown and change a new battery if need.

    LCD Display

    1. If no display on LCD even after power-on PCU again and again, the LCD display may befault, please change a new PCU to use.

    2. Switch on and charge PCU, no display on LCD but output power at AISG connector isnormal, the LCD display may be fault, please change a new PCU to use.

    http://support.huawei.com/support/http://support.huawei.com/support/http://support.huawei.com/support/http://support.huawei.com/support/
  • 7/22/2019 PCU User Manual(06)

    31/33

    PCU

    User Guide 4 Maintenance

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    25

    USB/AISG Module

    1. If used as a USB/AISG adapter, yellow light (USB) is still off after connecting PCU toPC with USB cable; or green light (RUN) does not wink during communication, theUSB/AISG module may be fault, please inspect inside after teardown and change a new

    PCU to use if need.2. If used as a USB/AISG adapter, PC fail to find out the COM port of CP3210x after

    connecting PCU to PC with USB cable, the USB/AISG module may be fault, or theCP210x driver has not been installed well. Please install driver first, and if this fault

    remains, the USB/AISG module may be fault, please inspect inside after teardown andchange a new PCU to use if need.

    Keyboard

    If one or more keys fail to respond operation again and again, there may a fault for thekeyboard, please change a new PCU to use.

  • 7/22/2019 PCU User Manual(06)

    32/33

    PCU

    User Guide A Appendix

    Issue 06 (2013-10-23) Huawei Proprietary and Confidential

    Copyright @ Huawei Technologies Co., Ltd.

    26

    A AppendixA.1 Abbreviations

    For the purposes of the present document, the following abbreviations apply:

    Abbr.

    AC Alternating Current

    AISG Antenna Interface Standards Group

    DC Direct Current

    HWV Hardware Version

    PC Personal Computer

    PCU Portable Control Unit

    RCU Remote Control Unit

    SWV Software Version

    USB Universal Serial Bus

    A.2 Return Codes and Alarm Codes

    The return codes and alarm codes PCU may displays as following:

    Code Type Display in PCU Comments

    0x02 Alarm Code Motor Jam Motor cannot move

    0x03 Alarm Code Actuator Jam Actuator jam has been detected

    0x05 Return Code BusyThe device is busy and cannot execute theprocedure until an ongoing activity is

    completed

    0x0B Return Code FAILAbnormal response. Indicates that aprocedure has not been executed

    successfully

    0x0E Alarm Code Not Calibrated The device has not completed a calibration

  • 7/22/2019 PCU User Manual(06)

    33/33

    PCU

    User Guide A Appendix

    operation, or calibration has been lost

    0x0F Alarm Code Not Configured Actuator configuration data is missing

    0x11 Alarm Code Hardware ErrorAny hardware error which cannot be

    classified.

    0x13 Return Code Out of RangeA parameter given by an operator (e.g. tilt

    value) is out of range

    0x19 Return CodeUnknownProcedure

    Received procedure code is not defined

    0x21 Return Code Working Software The unit is in DownloadMode state.

    0x24 Return Code Format Error

    Procedure message is inconsistent or thedata parameter field length is inconsistent

    with the corresponding field lengthparameter

    0x27 Alarm CodeActuatorInterference

    An actuator movement outside has beendetected. Probable cause is manual

    interference

    A.3 Suitable RCU Models

    PCU can be used as a RCU controller for following RCU models:

    ARCU01104, ARCU01109, ARCU01100, ARCU01101, ARCU01102, ARCU01103,

    ARCU01105, ARCU01106, ARCU01107, ARCU02001, ARCU02004. ARCU02000.