Paper Pres1
-
Upload
inderpreet-kaur -
Category
Documents
-
view
222 -
download
0
Transcript of Paper Pres1
-
8/2/2019 Paper Pres1
1/16
AUTHOR : CO - AUTHOR:
INDERPREET KOUR ER .NAVDEEP KAUR BRAR
-
8/2/2019 Paper Pres1
2/16
CONTENT
INTRODUCTION
MAXIMUM CURRENT THROUGH INDUCTOR OF BUCK CONVERTER
OPERATING REGION OF BUCK CONVERTER
OUTPUT VOLTAGE RIPPLE (OVR) OF BUCK CONVERTER
OUTPUT SHORT CIRCUIT DISCHARGED ENERGY (OSDE)
CONCLUSION
REFERENCES
-
8/2/2019 Paper Pres1
3/16
PAPER DEALS WITHMAXIMUM CURRENT THROUGH INDUCTOR OF
BUCK CONVERTER
OPERATING REGION OF BUCK CONVERTER
OUTPUT VOLTAGE RIPPLE (OVR)
OUTPUT SHORT CIRCUIT DISCHARGED ENERGY
-
8/2/2019 Paper Pres1
4/16
BUCK CONVERTER
It is a Step Down DC DC Converter.
It converts an input voltage into lower output
voltage.
A device termed intrinsically safe is designed to notcontain any components that produce sparks .
INTRODUCTION
-
8/2/2019 Paper Pres1
5/16
CIRCUIT DIAGRAM OF BUCK CONVERTER
-
8/2/2019 Paper Pres1
6/16
MAXIMUM CURRENT THROUGH
INDUCTOR OF BUCK CONVERTERANALYSED IN :
Continuous Conduction Mode (CCM)
Discontinuous Conduction Mode (DCM)
-
8/2/2019 Paper Pres1
7/16
1. CONTINUOUS CONDUCTION MODE
-
8/2/2019 Paper Pres1
8/16
2 . DISCONTINUOUS CONDUCTION MODE
-
8/2/2019 Paper Pres1
9/16
OPERATING REGION OF BUCK CONVERTER
-
8/2/2019 Paper Pres1
10/16
OVR OF BUCK CONVERTER
For L >L cc
For L< LCA
For LCA
< L
-
8/2/2019 Paper Pres1
11/16
LCA
< L< LCB
LCB
< L< L cc
-
8/2/2019 Paper Pres1
12/16
OUTPUT SHORT CIRCUIT DISCHARGED ENERGY
Summation Of Maximum Energy Stored in Capacitor
and Inductor
In CCM , it increases with inductor
In DCM , it is independent of the value of inductor
-
8/2/2019 Paper Pres1
13/16
If the maximum current of the inductor is less than the
minimum ignition current within the whole operating
region then converter meets the requirement of inner
intrinsic safety.
If MOSCDE is less than the corresponding minimum
ignition discharged energy then converter meets the
requirement of outer intrinsic safety.
-
8/2/2019 Paper Pres1
14/16
REFERENCES[1] Liu Shulin, Liu Jian. Intrinsically Safe switching Converters. Science press,
Beijing, 2008 (in Chinese).
[2] Shu-lin Liu, Yi - bo Ma, Yun-wu Zhang Optimal Design of Inductance and
Capacitance of Output Intrinsically Safe Buck DC-DC Converters . School of
Electrical and Control Engineering, Xi'an University of Science &
Technology,2010
[3] Liu Shulin, Liu Jian, Kou Lei, Zhong Jiuming. Analysis of Output Ripple
Voltage of Buck DC/DC Converter & Its Application. Transactions of China
Electro technical Society, 2009
[4] ZHOU Zheng hai, DENG Xian can, LOU Xiang xiong .The Design ofLow voltage High frequency PWM DC/DC Converter . Research & Progress
of SSE, 2004(4): 462-465,Apr.
-
8/2/2019 Paper Pres1
15/16
[7] Zhansong Zhang, Xuansan Cai, Theory and Design of Switching powersupply, Publishing house of electronics industry, Beijing,1998.
[8] Liu Xiaoqiang, On intrinsically safe DC switching power supply and its reserve
power supply Doctoral Dissertation of China University of Mining & Technology,
2001.
[9] Jianfei Li, Zhixin Xu, Heqing Zhong, Constant voltage restricted current and
constant current restricted voltage DC-DC converter. Power Electronic, 1999(1):42-
44, Feb.
[10] Shulin Liu, Jian Liu, Yinling Yang, Jiuming Zhong ChinaDesign of
Intrinsically Safe Buck DC/DC Converters . School of Electrical and ControlEngineering, Xi'an University of Science & Technology, Xi'an, 1996.
REFERENCES
-
8/2/2019 Paper Pres1
16/16
ANY ?...