Low Voltage Transformers - USESI Careers...TRANSFORMERS | Low Voltage 138 KICHLER® IN-GROUNDSERIES...
Transcript of Low Voltage Transformers - USESI Careers...TRANSFORMERS | Low Voltage 138 KICHLER® IN-GROUNDSERIES...
134 KICHLER®
TransformersLow Voltage
Power to perform: Why KichlerTransforms?
Kichler transformers are among the industry’s very best in features, quality and conformity to UL 1838 low voltagelandscape lighting standards and recommended practices according to the National Electric Code. This selection guide can help you choose the perfect custom solution for the job. Every product detail is engineered with one thing in mind; to provide real solutions for real pros.
135WWW.LANDSCAPELIGHTING.COM
SAFE
Runs feature one common transformerper circuit. UL requirements limit eachcircuit to 300-W and 15V.
Secondary circuit breakers offer short-circuit protection as a standard feature.
Magnetic circuit breakers provide afaster response to a fault in the system.
An in-line primary thermostat protectsagainst thermal over-load. Thesebuilt-in thermostats are auto-resetting,eliminating the need for replacement ormaintenance.
Because compliance is importantlong after the installation is complete –Kichler follows all applicable UL safetystandards, including UL 1838 and alltransformers carry a UL Listing marksuitable for the U.S. and Canadianmarketplace.
Internal wiring is rated for 150°C(302°F), which exceeds safetystandard requirements andprovides longer life.
POWERFUL
Various wattage options are availableincluding: 60, 75, 100, 200, 300, 600,900, and 1200 in many timer and plug-in options.
Available in premium or economyoptions – convenient for larger, morecomplicated jobs or where smallerprofile, lower-wattage units canbe used.
DURABLE
Full enclosure of the housing protectscomponents from weather, sprinklingsystems and debris.
Professional Series housings are madeof stainless steel grade 304 designedto run cooler and resist corrosion, andlast longer in outdoor environments.
Multi-tap transformers allow greaterflexibility in managing multiple wireruns by moving cables up and downthe multi-range. This assures that thecorrect voltage is applied to a lamp –creating a consistent light outputand maximizing lamp life.
DEPENDABLE
Every tap is tested on the assembly lineto ensure that output is consistentlyaccurate.
Installation is simplified, thanks to30°-tilted taps mounted on the125-Amp terminal board. This givesyou more space and greater visibilitywhile inserting cables into taps.
Units can be loaded up to the fullmaximum watts, including cablelength, fixtures and cable loss. Forease in calculating runs, Kichler providesa Voltage Drop Tool that features pull-down menus and professional printoutsfor recordkeeping.
WARRANTY
Limited lifetime warranty offered onStainless Steel (SS) transformer models.
A limited 10-Year Warranty on powder-coated Textured Architectural Bronze(AZT) transformer models.
CORE AND COIL CONSTRUCTION
All core and coil-types used in Kichlertransformers, except economy series,feature epoxy encapsulation. This providescommercial-grade benefits such as:
PROTECTION: Core, copper windings,wire leads and inner parts are set insideepoxy to prevent exposure to moistureto resist corrosion and maintain apermanent seal.
QUIET: Humming noises are eliminated,as well as vibration, keeping connectionsfrom loosening.
COOL: Epoxy also keeps unit runningcooler. Running cooler at full load issafer and conserves energy.
OTHER IMPORTANT INSTALLATIONCONSIDERATIONS:
Submersible rated transformers aredesigned and rated to provide powerfor fixtures placed in a pond, fountain orother landscape water feature. Fixturesused in water features must also be ratedfor submersible use. Transformers ratedfor use with submersible fixtures feature3' of #12-3 SJTW cord. They are NOTrated for use with fixtures in pools, spasor bodies of water intended for immersionof humans. The submersible rating featurevaries by model.
National Electric Code and UnderwritersLaboratories (UL) require that wiring,where concealed or extended through abuilding wall, must be enclosed in conduit.
TIP ON PRIMARY POWER:
Since 120-Volts can vary dependingon time of day and local utility fluctuations,always measure the voltage on the primaryside before and during job installation.Transformers reduce primary input in a ratioof 10:1 – Ex: 120 Volts:12 Volts.
Toroid coreand coilconfigurationis standard onProfessional Seriestransformers (except 15PR75SS)
EI core and coilconfiguration isstandard on all
other models
TRANSFORMERS | Low Voltage
136 KICHLER®
PROFESSIONAL SERIESKichler’s Professional Series provides thebest options and flexibility needed for mostinstallations. Output voltage range will suitmost jobs. Features include a commercialgrade toroid core and coil submersiblerating, pluggable timer and photocelloutlets, plus a lifetime warranty.
Not Shown: 15PR100 SS, 15PR200 SS,15PR300 SS,15PR600SS, 15PR1200 SS.
For details see chart on page 140-141.
FEATURES
Output voltage taps 12/13/14/15 Volts
Installation is made easy with 30° tiltedtaps mounted on a 125-Amp terminalboard because there is more space andgreater visibility while inserting cablesinto taps
Easy-access flip top door with magneticfastener requires no tools to open and islockable
Tilted terminal board and largecapacity lugs inside the taps hold upto 8, #10-gauge wires or up to 10,#12-gauge wires per tap
Submersible rating to be used in accor-dance with submersible standards wherefixtures are in water. The 3', #12-3 SJTWcord establishes the safe, distance tominimize shock hazards whensubmersible fixtures are being used
In-line secondary magnetic breakerprotects against short circuit
PROFESSIONAL SERIESSpecialty 75-W transformer has built-in ground connection for submersiblefixture that require grounding.Timer and photocell included.
FEATURES
Submersible rating to be used inaccordance with submersiblestandards where fixtures are in water.The 3', #12-3 SJTW cord establishesthe safe, distance to minimize shockhazards when submersible fixtures arebeing used
In-line secondary magnetic breakerprotects against short circuit
Fully enclosed housing constructedof #304 grade stainless steel
Mounting brackets are welded andriveted in place for extra strength.Mounting plate for indoor use isincluded. Transformers used indoorsrequire cable to be routed throughconduit. Check local governmentordinances and codes to ensureproper standards are met.
Limited lifetime warranty
Fully enclosed housing constructed of#304 grade stainless steel
Drop down bottom panel with fourpre-punched field knockouts sized for1⁄2" or 3⁄4" conduit (trade sizes) and onelarge center 13⁄4" inlet
All Professional Series units (except the15PR75 SS) feature toroid core and coiland dedicated wire loop for quickaccess testing of primary load. Thisprovides the best reliability andmaintains improved regulation fromno load to full load. Toroid core savesenergy and offers approximately 10%greater efficiency than EI-type core andcoil transformers. Toroid core and coilsrun cooler because heat dissipates, runquieter since there’s no hum, and runsmoother due to less vibration
900-W and 1200-W ProfessionalSeries units feature relay (contactor),which reduces amp draw through thetimer, photocell, and receptacle –extending the life of these components
Mounting brackets are welded andriveted in place for extra strength.Mounting plate for indoor use isincluded. Transformers used indoorsrequire cable to be routed throughconduit. Check local governmentordinances and codes to ensureproper standards are met
X10® compatible
Limited lifetime warranty
TRANSFORMERS | Low Voltage
137WWW.LANDSCAPELIGHTING.COM
PROFESSIONAL SERIES2-IN-1The Professional Series 2-In-1 Trans-former provides one distinct modeldesigned for unique applications wheretwo separate 300-W circuits (zones)and control options are located withinthe same housing.
For details see chart on page 140-141
FEATURES
2 separate sets of multi-tap output –12V, 13V, 14V, 15V on each circuit
600-W total power and (2)independently controlled 300-Wtransformers for 2 separate scenes
(2) independent receptacles forpluggable photocells for multiple on/offoptions
(2) independent receptacles forpluggable timers
Limited lifetime warranty
PLUS SERIESKichler’s Plus Series Transformers featurea 6' cord, pluggable options with a powdercoated steel case.
IMPORTANT: This unit is not approvedfor use with fixtures placed in ponds orlandscape water features.
Not Shown: 15PL100 AZT, 15PL300 AZT,15PL300 BE, 15PL600 AZT, 15PL600 BE,15PL900 AZT, 15PL900 BE
For details see chart on page 140-141
FEATURES
Output voltage taps are 12V, 13V, 14V,15V, 80 Amp. Max. per board
Powder-coated housing is paintedsteel with AZT or BE finish
Auto-resettable in-line primaryoverload protection
An in-line secondary magnetic breakerprotects against short circuiting
Epoxy encapsulated for greaterprotection and performance
X10® compatible
Mounting template included
10-year limited warranty
TIMER/PHOTOCELLSERIESKichler’s Timer/Photocell Series Trans-formers are an economical choice. Thebuilt-in timer can be removed but is notpluggable. The photocell plugs in and outfor easy replacement.
IMPORTANT: This unit is not approvedfor use with fixtures placed in ponds orlandscape water features.
Not Shown: 15TP200 AZT, 15TP600 AZT
For details see chart on page 140-141
FEATURES
Output voltage taps are 12V, 13V,15V, except 15TP200 AZT which isa single tap
Powder-coated housing is paintedsteel with AZT finish
Epoxy encapsulated for greaterprotection and performance
An in-line secondary magnetic breakerprotects against short circuiting
Auto-resettable in-line primaryoverload protection
X10® compatible
Mounting template included
10-year limited warranty
TRANSFORMERS | Low Voltage
TRANSFORMERS | Low Voltage
138 KICHLER®
IN-GROUND SERIESChoose Kichler’s In-Ground SeriesTransformers when direct burial isdesired. Units are hardwired with flyingleads so terminal lug taps are notprovided.
IMPORTANT: This unit is not approvedfor use with fixtures placed in ponds orlandscape water features.
Not Shown: 15IG600 SS
For details see chart on page 140-141
FEATURES
Output voltage taps are 12V, 13V,14V, 15V
Epoxy encapsulated for greaterprotection and performance
Auto-resettable in-line primaryoverload protection
10-year limited warranty
TIMER SERIESKichler’s Timer Series Transformers arean economical choice when conditionsrequire timer settings only and light willnot be available for photocell on/offsettings.
IMPORTANT: This unit is not approvedfor use with fixtures placed in ponds orlandscape water features.
Not Shown: 15T200 AZT, 15T600 AZT,15T900 AZT
For details see chart on page 140-141
FEATURES
Output voltage taps are 12V, 13V, 15V,except 15T200 AZT which is a singletap
Epoxy encapsulated for greaterprotection and performance
An in-line secondary magnetic breakerprotects against short circuiting
Auto-resettable in-line primaryoverload protection
10-year limited warranty
MANUAL SERIESKichler’s Manual Series Transformersare the ideal solution when on/offswitching is desired at the transformerand nowhere else. Timers and photocellsare not offered as options for this unit.
IMPORTANT: This unit is not approvedfor use with fixtures placed in ponds orlandscape water features.
Not Shown: 15M100 AZT, 15M200 AZT,15M600 AZT
For details see chart on page 140-141
FEATURES
Output voltage taps are 12V, 13V, 15Vonly on 15M300 AZT an 15M600 AZT.15M100 AZT and 15M200 AZT aresingle tap
Epoxy encapsulated for greaterprotection and performance
An in-line secondary magnetic breakerprotects against short circuiting
Auto-resettable in-line primaryoverload protection
10-year limited warranty
TRANSFORMERS | Low Voltage
TRANSFORMERS | Low Voltage
139WWW.LANDSCAPELIGHTING.COM
TRANSFORMERACCESSORIESAlong with a wide variety of transformers,Kichler offers a full complement of controlaccessories. Used separately or intandem, light may be controlled asdesired.
Photocells allow the intensity of daylight todefine transformer operation. Timers canbe used for more exacting requirements.Regardless of which is chosen, each willassist the transformer in providing thedesired result.
LED Backlight Outdoor EnclosedTransformer Timer
Digital Astronomical Timer
Synchronizer Device
Digital Transformer Timer Plug-In Transformer Timer
Plug-In TransformerRemote Photocell
Plug-In Transformer Photocell
15557 BK
15511 BK
15558 WH 15552 WH
15565 BK15534 BK
Battery not included
See Page 150
DIGITAL MANUAL
15559 WH
Photocells should befaced out (not up) for
optimum life
See Page 150
See Page 150 See Page 149
See Page 150
Photocells shouldbe faced out (not up)
for optimum life.
See Page 150
See Page 149
ECONOMY SERIESKichler’s Economy Series Transformersfor small jobs or single specialty pieceapplications. Built in photocell, timerand HI-LOW switch.
IMPORTANT: Model 15E120 is notapproved for use with fixtures placedin ponds or landscape water features.
Not Shown: 15E120 BK
For details see chart on page 140-141
FEATURES
High and Low output settings
Integral timer and photocell
Rated for use with submersible fixtures(15E60 BK only).
Durable black polymeric enclosureresists corrosion
An in-line push button thermal breakeron the secondary protects againstshort circuiting.
Auto-resettable in-line primary overload protection
10-year limited warranty
TRANSFORMERS | Low Voltage
140 KICHLER®
TRANSFORMERS | Low Voltage
Wattage (VA)
Automatic Timer
Photo Electric Eye
Compatible w/Plug-In Timers or X-10 Remote Systems
Hi-Low-Off Switch
On-Off-Auto Switch
Multi-Tap Connection 12V, 13V, 15V
Multi-Tap Connection 12V, 13V, 14V, 15V
Thermal Cut-Off on Primary Side
Thermal Reset Breaker on Secondary Side
Magnetic Breaker on Secondary Side
Easy Connect Terminal Blocks
6', 3-Wire #16-3 SJTW Cord
6', 3-Wire #18-3 SJTW Cord
3', 3-Wire #12-3 SJTW Cord
6', 2-Wire #18-2 SJTW Cord
Includes Mounting Plate for Indoor Use
Suitable for use w/Submersible Fixtures*
Ground Terminal
Direct Burial
Textured Architectural Bronze Powder Coat
Stainless Steel
Composite Housing
10-Year Limited Warranty
Lifetime Warranty
Toroid Core and Coil Configuration
EI Core and Coil Configuration
PREMIUM ECONOMY PLUS
PLU
S S
ER
IES
Text
ured
Arc
hite
ctur
al B
onz
e (A
ZT
) & B
each
(BE
)
73 /4"
x 33 /
4"x
41 /4"
19"x
51 /
2"x
53 /4"
19"x
51 /
2"x
53 /4"
211 /
4"x
63 /4"
x 53 /
4"
19"x
63 /
4"x
53 /4"
21"x
63 /
4"x
6"
171 /
2"x
8"x
7"
19"x
51 /
2"x
53 /4"
19"x
51 /
2"x
53 /4"
19"x
63 /
4"x
53 /4"
21"x
63 /
4"x
6"
15P
R75
SS
15P
R20
0 S
S
15P
R30
0 S
S
15P
RD
600
SS
2-in
-1
15P
R60
0 S
S
15P
R90
0 S
S
15P
R12
00 S
S
15P
L200
AZ
T/B
E
15P
L300
AZ
T/B
E
15P
L600
AZ
T/B
E
15P
L900
AZ
T/B
E
75 100
200
300
600
600
900
1200
100
200
300
600
900
PR
OF
ES
SIO
NA
L S
ER
IES
Sta
inle
ss S
teel
(SS
)
15P
R10
0 S
S
15P
L100
AZ
T
19"x
51 /
2"x
53 /4"
19"x
51 /
2"x
53 /4"
141WWW.LANDSCAPELIGHTING.COM
TRANSFORMERS | Low Voltage
ECONOMYT
IME
R/P
HO
TO
CE
LLTe
xtur
ed A
rchi
tect
ural
Bo
nze
(AZ
T)
TIM
ER
UN
ITS
Text
ured
Arc
hite
ctur
al B
onz
e (A
ZT
)
MA
NU
AL
UN
ITS
Text
ured
Arc
hite
ctur
al B
onz
e (A
ZT
)
EC
ON
OM
YB
lack
(BK
)
131 /
4"x
31 /2"
x 4"
131 /
4"x
41 /2"
x 4"
141 /
4"x
51 /2"
x 5"
131 /
4"x
31 /2"
x 4"
131 /
2"x
41 /2"
x 4"
141 /
4"x
51 /2"
x 5"
19"x
61 /
2"x
6"
8"x
31 /4"
x 3"
131 /
4"x
31 /2"
x 4"
131 /
2"x
41 /2"
x 4"
141 /
4"x
51 /2"
x 5"
63 /4"
x 33 /
4"x
33 /4"
103 /
4"x
41 /2"
x 43 /
4"
103 /
4"x
41 /2"
x 43 /
4"
15T
P20
0 A
ZT
15T
P30
0 A
ZT
15T
P60
0 A
ZT
15T
200
AZ
T
15T
300
AZ
T
15T
600
AZ
T
15T
900
AZ
T
15M
100
AZ
T
15M
200
AZ
T
15M
300
AZ
T
15M
600
AZ
T
15E
60 B
K
15IG
300
SS
15IG
600
SS
SPECIALTY
200
300
600
200
300
600
900
100
200
300
600
60 300
600
600-W, 900-W and 1200-WTransformer models aremanufactured in intervalsof 300-W (VA) circuits.
National Electric Code andUnderwriters Laboratories requirethat wiring, where concealed orextended through a building wall,must be enclosed in conduit.
All transformers are for outdooruse only unless otherwise noted.
All Transformers carry aUL 1838 Listing mark suitablefor the U.S. and Canadianmarketplace.
IMPORTANT: These units are notapproved for use with fixturesplaced within 10' of swimmingpools or spas.
15E
120
BK
120
= INCLUDED
= OPTIONAL
Plug-in KichlerAccessories - ReferenceAccessories Descriptions,page 113: Plug-InTransformer Timer15552 WH or 15557 BKDigital Timer 15558 WH15559 BK, Plug-InTransformer RemotePhotocell 15534 BK,Plug-In TransformerPhotocell 15565 BK
* = Not for use with swimmingpool or spa fixtures.
67 /8"
x 3"
x 3"
IN G
RO
UN
DS
tain
less
Ste
el (S